DOOR
CONTRO
PRESTART
LAMP
L CKT
SOV
TG control in remote.
GV Fully Open
GV Fully Closed
MIV Open
MIV Close
MIV Piston Creep
1
1
1
1
1
1
1
1
1
ANNUNCIATOR
TRIP
MASTER TRIP
ALARM
86B
86C
1
1
1
1
1
1
1
1
1
1
1
MULTIPLICATI
ON
REQUIRED
Timer
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
OTHERS
86E
PLC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
DI
GEN LOS OIL FLOW3 LOW-DE GUIDE BRNG
GEN LOS OIL FLOW3 TRIP-DE GUIDE BRNG
GEN LOS OIL FLOW4 LOW-NDE GUIDE BRNG
GEN LOS OIL FLOW4 TRIP-NDE GUIDE BRNG
GEN BEARING TEMP HIGH(DE)
GEN BEARING TEMP HIGH(NDE)
CW FLOW FOR STATOR ALARM
CW FLOW FOR STATOR TRIP
CW FLOW PRESSURE HIGH AFTER COOLER
CW FLOW PRESSURE ALARM
CW FLOW PRESSURE TRIP
CW PRESSURE FOR STAND STILL SEAL
CW PRESSURE LINE FILTER CLOGGED
Unit speed 10%(0 approx)
Unit speed 90%
Unit speed 110%
Gen brkr opn
gen brkr closed
nis open
nis closed
Gen prot relay optd(Urgent)
Gen prot rly faulty
24 V DC supply healthy
TSR-1 Hlty
TSR-2 Hlty
Trip relay 86C optd
Trip relay 86E optd
Sync in Auto
SPMD ON
Sync speed raise
Sync Speed lower
Sync Permit
AVR ON(Excitation ON)
AVR Alarm
AVR Tripped
EMG PB Operated
GEN Brkr Sprng Charged
Gen Brkr Remote Selected
Unit AUX Remote Closed
SOV
ANNUNCIATOR
DOOR
CONTRO
PRESTART
LAMP
L CKT TRIP
ALARM
86B
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MASTER TRIP
86E
86C
1
1
PLC
Timer
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MULTIPLICATI
24/110
ON
VDC
REQUIRED
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
DI
Charger Faulty
Battery in Boost Mode
DG SET ON/OFF
T OPU MM REMOTE
T OPU MM MPCB ON/OFF
T OPU MM TRIP
T OPU MAIN MOTOR ON/OFF
T OPU SBMPCB ON/OFF
T OPU SB TRIP
T OPU SB ON/OFF
GEN LOS AC MOTOR MPCB ON/OFF
GEN LOS AC MPCB TRIP
GEN LOS AC MOTOR ON/OFF
GEN LOS SB MOTOR MPCB ON/OFF
GEN LOS SB MOTOR TRIP
GEN LOS SB MOTOR ON/OFF
GEN LOS DC MOTOR MPCB ON/OFF
GEN LOS DC MPCB TRIP
GEN LOS DC MOTOR ON/OFF
LINE ISOLATOR OPN
LINE ISOLATOR CLOSE
Gen prot relay optd(non-Urgent)
HT BREAKER OPEN/CLOSE
LINE BREAKER 86T OPTD
TRAFO HT BREAKER 86T OPTD
DO
GV OPEN
GV CLOSE
BYPASS VALVE OPEN/CLOSE
MIV OPEN
MIV CLOSE
BRAKE APPLY
BRAKE RELEASE
De-Energize to Shutdown
PC Selection
OPU MM ON
OPU MM OFF
Facia
DOOR
CONTRO
PRESTART
LAMP
L CKT
ANNUNCIATOR
MASTER TRIP
OTHERS
TRIP
ALARM
1
86B
PLC
86C
MULTIPLICATI
OTHERS
ON
REQUIRED
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
TIMER
DO
SOV
OPU SB ON
OPU SB OFF
GEN LOS AC MM ON
GEN LOS AC MM OFF
GEN LOS AC SB ON
GEN LOS AC SB ON
GEN LOS DC MOTOR ON
GEN LOS DC MOTOR OFF
AUTO SYNC ON
AUTO SYNC OFF
SYN VOLTAGE CONNECT ON
SYN VOLTAGE CONNECT OFF
PROTECTION RLYS TRIP CMD
PROTECTION RELAY RESET
PROTECTION RLYS RESET(TO BRKR AND LAVT)
GCB OPN
GCB CLOSE
AVR ON
AVR OFF
AVR RESET
AVR AUTO
AVR MANUAL
GEN SPACE HEATER ON
GEN SPACE HEATER OFF
86B TRIP RELAY RESET
LINE BREAKER OPEN
LINE BREAKER CLOSE
TRAFO HT BREAKER OPEN
TRAFO HT BREAKER CLOSE
AI
GV POSITION
TOPU OIL PRESSURE
GENERATOR SPEED
Bypass pressure balance.
KW INPUT SR-489
Pressure transducer before BFV
DOWN STREAM
FACIA
ANNUNCIATOR
DOOR
CONTRO
PRESTART
LAMP
L CKT TRIP
ALARM
86B
MASTER TRIP
86C
86E
PLC
OTHERS
MULTIPLICATI
ON
REQUIRED
TIMER
RTD
WINDING R1 PHASE
WINDING R2 PHASE
WINDING R3 PHASE
WINDING Y1 PHASE
WINDING Y2 PHASE
WINDING Y3 PHASE
WINDING B1 PHASE
WINDING B2 PHASE
WINDING B3 PHASE
GEN DE GUIDE BEARING
GEN NDE GUIDE BEARING
DE BEARING OIL
NDE BEARING OIL
MAIN THRUST PAD
REVERSE THRUST PAD
AIR INLET
AIR OUTLET
OPU OIL TEMP
Set Values
6o bar
55 bar
60 deg
65 deg
0 TO 120 DEG
0 TO 120 DEG
0 TO 120 DEG
0 TO 120 DEG
FB VTG
SET VALUES
FB VTG