I.
General
To design adequate glass of a spider pin supported curtain wall meeting required criteria.
All units is in metric system.
II.
Design Calculation
1
Design Code
BS 8118 Part 1:1991:Structural Use of Aluminium. Code of Practice for design
ASCE 7-05 Min. Design Loads for Buildings and other Structures
Material used
16 mm thick glass
(8+1.5+8)
33.00
N/mm2
49.00
N/mm2
138.00
N/mm2
Modulus of Elasticity, E
72000.00
N/mm2
0.4238
kN/m2
:
:
:
:
:
45.00
75.00
75.00
122.00
9.10
m/s
m
m
m
m
1.250
kN/m2
Loading
Dead Load (DL)
Wind Load
Load Combination
Glass weight
Basic Wind Speed, v
Length of Building, L
Width of Building, W
Height of Bldg., H
Top of spider wall
3-sec gust
3522
1262
mm
mm
glass
= M*6/(t^2*B) =
5.83
Note:
B=
1000 mm
t=
16 mm
(8+1.5+8)
Check the deflection of glass panel
Deflection due to horizontal loading
Note: (consider 1000mm width)
q=
1.25 x
L=
1262 mm
ExI=
2.4576E+10
deflection =
1.68 mm
N/mm
248,851 Nmm
Mpa <
49
1=
1.25
N/mm
<
1262
60 =
138 )
glass
Mpa ok
21.0
mm ok