Anda di halaman 1dari 16
2500/2520 Automatic Tank Gauge ~ Simple and reliable liquid level measurement for bulk storage applications Highlights “+ Low cost, continuous measurement - up 0.2” (€ mr) accuracy ‘+ No power required for continuous operation ‘+ Meets API Chapter 3.18 regulations for inventory control applications ‘+ Easy 10.224 display - metric or imperial in decimals o fractions “+ Wide variety of installation kits and materials available ‘+ Mounting for optional transmitters or limit switehes +2520 ATG High pressure version available - 150, 220 or 300 PSI ‘gauge ‘+ Floats available for standard, interface, or stiling well applications ‘+ ATEX approved fo use in potentially explosive atmospheres ‘+ Optional Negator Cassette for reduced maintenance and Increased safety Application ‘The 2500 series of Automatic Tank Gauges (ATG) are mechanically ‘operated, float anc tape instruments designed to provide continuous liquid leve! measurement in bulk storage applications. “The measured levlis displayed using 2 dial and counter bult into the {gaugehead. The 2500 ATG has many product options that allow itto be installed on the tank roof or atthe tank side (at grade}, which would facilitate ground level reading by the operator. electronic transmission of level data or temperature measurement integration is requited in the control room, then the gauge can be fitted with an ‘optional tank gauging transmitter, Example Tank Gauging System 2500 ATG (foreground) 2520 ATG (background) Operation The 2500/2520 Automatic Tank Gauges (ATG) are designed to provide continuous liquid level measurement for bulk storage ‘applications. ‘The 2520 High Pressure Automatic Tank Gauge is designed to provide continuous liquid level measurement of products stored in Pressurized vessels. The 2520 provides the speciiconsiderations or ‘options for installation on high pressure vessels ‘The level measurement i displayed using a dial and counter built into the augehead. The gaugehead can be installed on the tankroof ‘or at the tank side (at grade), which would facilitate ground level reading by the operator If electronic transmission of level data or ‘temperature measurement integration is required inthe contral room, then the gauge can be fited with an optional tank gauging ‘ransmiter ‘As standard, the 2500 ATG utes a large stainless stee! float thats attached tothe stainless steel perforated tape to detect the liquid level. The float follows the liquid evel a it rises an falls due tothe constant pullback tension provided by a powerful negator spring oF ‘cartridge motor. The precisely perforated tape engages pins on 2 sprocket whee! that in turn drive the counter assembly. Ths simple ‘design ané operation allows the gauge to perform with negligible ‘maintenance throughout its working life. Due to high pressure conditions, the 2520 ATG utilizes a magnetic ‘drive that operates the dal reading mechanism. This drive provides ‘2 postive seal-off ofthe counter compartment and the transmitter housing eliminating danger of glass breakage, loss of product and the escape of vapors, makingit an important safety feature for both personnel and plant facilities. For more Information visit www-tankgauging.com 2500/2520 ATS Installation Guidelines ‘rious installation options and accessories are available to sult user installation requirements. The following information should be used ‘as aguide only please refer to the operation and maintenance ‘manual for complete instalation instructions. All pats of the gaugehead, tape and float should move freely to reduce wear and maintenance. Ths section recommends general considerations when insaling afloat and tape operated tank gauge. In-service vs. Out-of-service Installations For in-service and out-o-servce installations, how a guidewire is anchored at the tank bottom and welding parts to on the tank are ‘major considerations Floating Roof Tank Installations In floating roof tank installations ts recommended that gauges be installed ina floatwel, rather than attaching the tape directly to the tank root. The floatwell should contain abatfl ta prevent the float {rom escaping, but also allow sufficient product movement to ‘equalize the liquid level. No tape should be exposed, outside of the roof or pipework. if any section ofthe tape is currently exposed it should be replaced with a stainiess steel, flexible cable. This will reduce measurement error due to winddrift. The connector between ‘the tape and cable should not un aver a conduit elbow (or pulley) Note! An internal floating rootis often referredtoas "Pan e.g.3 ‘one roof tank with 2 pan and floatwell Guidewires VVarec recommends guidewire installations for the 2500 and 2520, [ATGs with standaré guidewire centers of 17" (432 mrn) when a ‘standard 14.5" (368 mm) diameter Type 316 stainless steel hollow shell float is used. Guidewires provide stablity forthe float during turbulent conditions and provide increased accuracy by reducing the horizontal movement ofthe float across the surface of the product, ‘The guidewires should be installed centered and free of twists or inks, Check the movement of the float for friction or impended ‘movement before final operation. Note! Varec recommends guidewire installations or stiling well, installations where possible, Guidewire Anchors \Varec provides two options for tank bottom, guidewire anchors, in- service and out-of service anchors, The in-service anchor (weight) hangs from the rof to level just above the tank bottom. The out ‘of service anchor can be welded tothe tank bottom. See the ‘accessories below for further details. Varec top guidewire anchors ‘an be screwed or welded into the tank roof, maintenance hatch or manhole cover. ‘Support Brackets "A" frame brackets suppor the conduit (pipework that caries the tape. These brackets can be welded or bolted tothe tankand should be placed at regular intervals (approx. 10ft or 3 meters) to provide uniform support. The pipework should be held rigidly in place and correctly aligned so thatthe tane does not touch or rub the internal pipework Tank Roof Entry Varec can provide manhole or inspection covers for ease of, installation and maintenance ofthe float, tape and guidewires. Tape conduit and guidewire anchor entries into the tank roof should be ‘eat an existing manhole cover or be made through a manhole cover, See accessories below for further details, Float Grounding Cable Varee provides a grounding cable forthe float to prevent the bud up of static electricity. ‘ares ne. Automatic Tank Gauge Tas2mai === =6 Recommended 24.00" (610mm) Maximum 36.00" (914) Winimans 18.00" {406mm 8.00" {203mm Layout for conduit supports (pipework) Spaced at ‘approximately 401 (2m) intervals | 5.00" 152mm] Convenient eye level Grade ‘ample deals ofa cone rool tank alain, Note tal measurements may ary depending onthe specific tank type and instalation. Technical information 2500/2520 ATG Installation Options Various accessories are provided, depending onthe installation type selected, inthe product order codes. Cone Roof Tank Order Code TO1, 1,721, 722,723, 124,734,733, 734 TAD, 742 Installation parts supplied include 1 + Gauge U bottt + Guidewire batiom anchor ow assem (2) 1+ Support beacket (6) + oat + Guidewire top anchors 2) Bolted Tank Order Code Tos, 125 Installation parts supplied include + 90° elbow assembly (2) + Guisewires + suppor bracket assembly 4+ Suppor bracket (x7) + Gaugehead and ape + Float + Guidewire top anchors 2) + Tape connector: + 1a/2beck lange Cone Roof Tank with Pan and Floatwell Order Code 102, 112 Installation parts supplied include: 1+ 90" elbow assembly 2) + Gouge U'bottkt + support bracket (6) + Gougehead and tape/eable + Float + Tape/eabie connectors Varee, Ine ‘Automatic Tank Gauge Cone Roof Tank and Pan: No Floatwell Order Code 107,117 Installation parts supplied include: 190" Etbow assembly 2) + Gauge’ botekit + suppor bracket 6) + Gaugenead ané ape/eabe + Tape/eable connectors ‘Tank Top Mounting Order Code TOs, 114,724, 732 Installation parts supplied include: + Gauge’ botekt + Guidewie bottom anchor + Gaugeheadané tape + oat 4+ Guidewiretop anchors 2} + Tape connectors Stilling Well Service Cone Roof Tank 6" Diameter Float. Order Code 755, 756 Installation parts supplied include, 190" Etbow assembly 2) + Gauge’ botekt + Guidewie anchor weight + Guidewies + Suppor bracket 6) + Gaugeheadané tape + Float 1+ Guidewietop anchors (2) + Tape connectors Floating Roof Tank and Floatwell Order Code 103,113, Installation parts supplied include: + 0° Ftbow assembly 2) + suppor bracket assem 1 Suppor bracket 6) ‘+ Gaugened ans tape/cabe + Float + Tapefeable connectors Technical information 2500/2520 ATG Floating Roof Tank: No Floatwell Order Code TO6, 726 Installation parts supplied include 1+ 90° Elvow assembly 2) + Gauge U bottt + Suppor bracket assembly 1+ Suppor bracket (6) + Gaugenead and tape/eable + Tapeleable connectors Interface Service Order Code T51, 152,753, 754 Installation parts supplied include ow aesemby (2) + Guidewir botiom anchor + Guisewires + Suppor bracket (6) + Gaugenead and ape + nertace at + Guidewire top anchors 2) + Tape conn Sphere Tank to 16ft (4.9 m) or Horizontal Cylinder Tanks 2520 ATG Order Code T01, TO Installation parts supplied include +90 elbow assembly 2) + Guidewirebatiom anchor + Suppor bracket (2) + Gougehead and tape + Guidewire top anchors 2) + Mrcbraciet Sphere Tank to 48ft (14.6 m) or Horizontal Cylinder Tanks 2520 ATG Order Code T02, 706 - Installation parts supplied include: + 90° elbow assembly st) +45" elbow assembly (2) + Guldewire batom anchor + Support bracket (2) + Gougehead and ape + Float + Guldewire top anchors 2) + wrcbracket CF Varee, Ine ‘Automatic Tank Gauge ‘Top Mounting for Sphere or Horizontal Cylinder Tanks 2520 ATG Order Code T03, 107 Installation parts supplied include: + Guidewie bottom anchor + Guidewies ‘+ Gaugenead ans ape + Float + Guidewie top anchors (2) ‘Sphere Tank to 60ft (18.3 m) or Horizontal Cylinder Tanks 2520 ATG Order Code TO4, TO8 Installation parts supplied include: 1+ So Etbow assembly et) + 30° Fbow assembly 5) + Guidewies + suppor bracket (2) ‘+ Gaugenead ans ape + Float + Guidewie top anchors 62) + MTG bracket Technical information 2500/2520 ATS Model Options English and Metr \Varec provides the following three measurement an¢ display confguratios: Configurations + English fraction feet/inches/ 6th English decimal -feet/inches/1oths + Metric configurations - meters/10ths/100ths English reading gauges are manufactured with 3 reversible {ractional/decimal dal. For example, ifthe customer desires a decimal level display, the dal can be removed, reversed and reinstalled to show decimal units Al diaeounters reflect product innage. For outage reading requirements, Varec offers 2 conversion kit (Part #13-08774) for English units of measure only Check Knob [An operation checker, provided as a standard feature on both the 2500 and 2520,ATG, permits your technician to check the instrument for correct operation. Negator Cassette ‘The negator cassette improves the performance of your mechanical tank gauge by selFaligning the tape and motor ast provides the ‘constant pullback tension requited for the float to folow the liquid level. The cassette increases reliability and reduces maintenance by protecting internal moving parts from pipe debris that could cause stretching or corrosion It also allows for safer, easier and quicker service as there sno tape to pullout or negator hubs to unwind in your hands. Float Crank ‘The float crank allows your operators to manually aise and lower ‘the loa. This can be useful during turbulent mixing conditions so ‘thatthe float or tape is not damages. Plug Valve VVarec recommends the use ofthe 275 Rubber Plug Gate Valve when installing the 2520 ATG on high pressure vessels. This permits the user to seal off tank working pressure from the gaugehead and tape piping system for routine inspection and maintenance. The plug valves have 14" (38 mm) ANSI RF flanges, Viton-A plug and are rated. {or either 150 PSI (1034 kPa) or 300 PI (2068 kPa) gauge pressure. Transmitter Adapters ‘When directly mounting a transmitter or SPDT cam-operate limit snitch tothe 2520 ATG, Varec recommends the use of a2581 (Oil Tight) Transmitter Adapter. Floats ‘The 2500 ATG provided with standard 17° (432mm) lameter Type 316 stainless steel hollow shell float. Depending onthe type of service kit selected, moderate, severe or extreme, one ofthe floats ‘may be supplied shown in the table below. ‘The 2520 ATG is provided witha standard 8” (203 mm) diameter ‘mult-sphere 36 stainless steel lot, To ensure the highest possible ‘measurement accuracy, the specifi gravity ofthe product being ‘measured is required to properly adjust the weight ofthe float. Standard 2500 TG fat hollow shel oat (lf), Standard 2520 ATG Mult sphere lat (idle, 6 interface loa ght) 10 Varee ne Automatic Tank Gauge 2500 ATG Service Kit Materials Description ‘Standard Moderate Severe Extreme (N20) xtreme (1,50) Gauehesd ‘Nuinumy ‘inom ‘astron aston castron how assembly ‘Aina HOSS, canton Gattiron aston Top anchors ‘See! HBSS, Stee Stel ‘Sw/Corp. 20 Guidewie weight Steel n1685. 68S. Monel cn.20 Asandardfost 2520 ATG Service Kit Materials Deserstion Matera Caugehend Cast cabon eel ASTIN A216, WEB (Countar housing cover Ga Auminum Sprocket, Motor Storage and Tape storage sheaves Goat Aorinom ‘Negaar spring, Perforated tape and Sprocket Pine Type 301,303 or BIB aailess eel Bearnae Sales 8 Floats art Material Net Weight size ‘8074-000 BESS. 5b aka) 1 (632 me at 122339.000 carp. 20 107 B69 ¥@) 17° (432 mm Fat 1Mi2338-000 ‘Monel 10516 (484g) 1 (422 mm) Fat, pwizeat 36 ne 203 mm Mult sphere 8237777006 HOSS Depends on specie gravtyet | 8° (208 mm) Sphere interface) product contact varee B2a7782 008 es 1 (53 mm Sphere terface} 1737783.006 3655 10" (254 mm Sphere interface) rae Fibre gas ob 27" (32 mm Flat, Conduit Elbows Pare ‘angle | Description Pressure Rating Conduit Materia Wheel Material eva66 o Ew 1350 PI 2034 a) eae castiron| 3655 evano2 0 Elbow 300 P2068 xP} gage | Castcon ness v480 = ow 300 P2068 Po) ea Casteon 36s evaa89 0 ow 300 PS (2068) age | Castron 695 osonsee [90° bow ‘Amosphene ‘Aluminum ebin osorrs (30° how ‘Atmospheric Alumina 31655 Baers 90" how ‘mosphere Gastron 31658 Bwso7e 3 ow ‘tmospheve 36 Staines tee 3165 eas nas | ebow ‘Nmospherie ‘Alun Delrin 346 180°‘ ebow ‘Amosphene ‘Aluminum Delrin e623 NA Tope cater ‘Atmospheric ‘Aluinom Debin Technical information u 2500/2520 ATS Accessories Gauge Calibrator Assembly The Gouge Calibrator allows level A transmitters with absolute encoders tobe » > s calibrated without disassembling the bess “a ‘transmitter from the gaugehead. The Os calibrators accessed by removing the g counter assembly cover. By turning the calibrator, the counter and the transmitter can both be set to the proper level. The dual calibrator can be retrofitted to existing 2500, [ATG installations (Part #13-08948), Condensate Reservoir ‘The condensate reservoirs designed to collect condensate that would otherwise Fi accumulate inthe gaugenead. suse is recommended where an excessive amount ‘of condensate could develop or ino filed sauge applications (Part #0A8051). Shock Absorber a ‘The Shock Absorber reduces wear and maintenance on a 2500 ATG by minimizing A the transfer of wave energy fom the lotto 4 the perforated tape and gaugehead ‘components. It prevents the float from becoming detached from the tape by wave action and should always be used in tanks ‘with turbulent conditions near inlet or outlet Diping and near a mixer (Part HOAG38). Manhole Cover — Guidewire Anchor Varec can supply two sifferent guidewire anchors (also referred to as bottom anchors or weights), depending on the installation type. An anchor that can be welded to the tank bottom is see when the tank out-of service (Stee! Part #AA1025) (Stainless Steel Part #05-08208) or (Monel Part #05-08203).A cast iron weight can be used as an alternative when the installation is performed While the tanks in-serviee (Part #BA8482), Conduit Elbows Conduit elbows reduce wear on the tape and provide various installation options, depending on the tank type. Varec can arovide various angles, materials and low/bigh pressure options. Conduit Oil Seals Oil seals designed into the conduit pipework during Installation can help reduce wear andmaintenance on the tape, conduit and gaugehead pats. The seals also prevent SJ theloss of damaging fumes or q corrosive vapors. Depending 5 ‘on the installation, the We following ol seals are available: ‘This manhole cover (Model 226) allows for In-service installation of the 2500 ATG ‘through a tank's existing manway. each or the three port entries i threaded fr simple installation of pipework or guidewire ‘anchors. (Part HBM3443 for 20°, Part {#93607 for 24"), Inspection Cover This inspection cover (Model 228) can be installed onto an existing manhole cover, to provide an easily removable inspection plate (Pare #6746}. Float Grounding Kit ‘The Float Grounding Kit positively grounds the float to the tape or able (Part # 13 10974), Roof Weight Kit ‘The roof weight is used in floating roof apalications to reduce the likely hood thatthe tape/cable is damaged by a sudden roof drop. It sits on top of the float (Part # 844580-003), 1 oof and is connected ta the tape/cable x0.0189¢AaA | Auminum | 8.5 (216mm) Water column ope pressure sootsse-aaa | castion | 85" (216mm) Water column operating pressure 10.02851-AKA | Auminam | 27 (686mm) Water column operating pressure Teflon Tape Wipe Generally used with the conduit vent, the Tape Wipe (Model 25465) can also be used alone. The Tape Wipe mounts in the conduit between the top of the tank ané the ist elbow and removes excess residue from the tape. It minimizes vapor loss from the tank into the conduit and helps prevent vapors and liquids from contaminating the gaugehead (Part #8A13924), 2 ‘ares ne. Plug Gate Valve \Varec recommends the use of the 275 Rubber Plug Gate Valve when instaling the 2520 ATG on high pressure vessels. Tis permits the user to seal off tank working pressure rom the gaugehead ‘and tape piping system for routine inspection and maintenance. The plug valves have 1-" (38 mr) ANSI RF flanges and are ated for 150 PSI (2034 kPa) (Part #2752V) or 300 PSI (2068 kPa} (Part #2752V) gage pressure Guidewire Top Anchors Guldewire top anchors provide a point on the tank roof to connect the guidewire during installation, The internal spring provides a constant tension on the Buidewire, which reduces horizontal movement ofthe float due to turbulent conditions. Guidewire top anchors can be screwed or welded directly onto the tank roof or into an existing manhole cover. Automatic Tank Gauge Negator Cassette The negatoreasset Improves the performance of your mechanical tank gouge by selfaligning the tape and ‘motor ast provides the constant pullback tension requited for the float to follow the liquid level. The cassette increases reliability and reduces maintenance by protecting internal moving pats from pipe debris that could cause stretching or corrosion It also allows for safer, easier and quicker service as there is no tape to pull out or negator hubs to unwind in your hands. ‘The negator cassette ft all alumninum Varee 2500 (mode! 8} ‘Automatic Tank Gauge and can be ordered as an option, a Cassette Kit for negator motor to cassette conversion kit (shown) (Part #13. 110652) ora Cassette Assembly only (Part #06-10368), Maintenance Kits ‘regular schedule of maintenance is recommended, The frequency lof such inspections depends on the specific environmental conditions and operation, Due tothe various conditions, even from tank to tank on the same site, installations shouldbe studied and a routine of inspection and maintenance should be planned thats best sulted to individual needs, arte Materia Pressure rating 5200 Steel ‘maspherie serision 13-08766 2500 Base Maintenance Ki Engih emsoas B16 Stainess Stee! | Atmosphere amae4s steel 250 511034 ka) gage - — 13.08768 2300 Extended Maintenance Kt Ealish aaea7 Steel 300 512068 ka) ange 5.08769 2500 Extended Malntanance Kt- Matic ‘Support Brackets 13.0870 2500 OverhaulfReturbishing KR Enash frame brackets support (>)? 3308771 2300 OverhaulRefurbishingKt- Metric ‘the condult (pipework) that ‘artes the tape. The steel Le 3.097900 __| Shoulder Bushing Kk pipe support brackets used canded fone Wodlcaion Fafa eee rinerank aee L, 33.0877 Extended Range Modification Kt Ergish #835643.003) and the upper 33.0877 Extended Range Modification Kt- Metric support bracket assembly is Side tised at the tank top (Part {bracket 1308778 (Outage Reading Conversion Kit Engish wem7s7, 33-08785 2520 ATG Base Maintenance Kt- Metric 13.08787 2520 ATG Overhaul/Refrbishing Kt- Metre 3.07824 English Courter emnesea English to Metric Conversion Kit ‘awesco Metco English Conversion Kt 13.1087 Fst Grounding Kit Technical information B 2500/2520 ATS System Integration Tank Gauge Loop comminentons| Fusobarager more ‘Sofware LJ LJ «LJ Low Conmuncetion a. Meds LS. Communeatens Control Room ele at 5 J SORTS ToOO FT System Da ‘Arange of analog and digital tank gauge transmitters is available that ‘mounts rectly to mechanical tank gauges. Level measurement data is encoded by the transmitter and output va industry standard ‘communications to the contr room. Some transmitters also offer spot temperature measurement integration that can be used for inventory control apolications. When a tank gauge transmitter is used, communications and power are required atthe gaugehead \Varec transmitters do nat require an adapted flange. When connecting third party equipment, a specific adaptor flange, ‘depending on the transmitter, is often required 2557 Alarm Limit Switch The 2587 Alarm Limit Switch (ALS) i designed to mount directly to the 2500 Automatic Tank Gauge (ATG) or ata conduit elbow. It provides 2 contact closure or opening ata pre:set cam position to allow for alarm indications. The 2557 ALS is available with 2,4 or 6 switches that can be used to activate alarms or relays at any lev! selected by the user. For further information, refer to product documentation, itis commended to use 2 2581 (Oil Tight) Transmitter Adapter (Part #8M19900-200) when directly mounting a transmitter or SPOT cam-operated limit switch to 22520 ATG, 4 ‘ares ne. Automatic Tank Gauge 2910 Float & Tape Transmitter The 2900 Float & Tape ‘Transmitter (FTT) provides data from the tankside tothe ‘ontral room for use in inventory management volumetric aleuations. The 2910 FTT utilizes an absolute ‘apace encoder to ‘accurately convert the mechanical level Technical Specifications 2500 ATG Product gravity [07191 9/700 9900 kal) ‘lominum — Atmosphere 2.5 PS [72x] {Cast ton — Atmospheric to 10 51 (6595 kPa} measurement from the ‘connected tank gauge. The 2910 FTT is als able to integrate a single temperature sensor and provide cam-operated switches for the indication of alarms o relays. Level and temperature information is ‘transmitted vi one of the following field communications protocols: + Mark space + EIA485 MODBUS/GSI Type MODBUS + Tankway (L24) 2920 Float & Tape Transmitter The 2920 Float & Tape trans side to the control room for use in inventory management ‘applications. It converts mechanical level measurement from the tank gauge, integrates temperature and HART devices, and provides ligtal inputs and digital outputs for the indication of alarms or drive relays. Level and temperature information is transmitted via one of the folowing field communications protocols: + Biphase Mark + 14.485 MODBUS/GSI Type MODBUS £8200 Current Output Transmitter The 8200 Current Outout Transmitter (COT) is 3 precision analog transmitter designed to relay evel Information via field ‘communications to the ‘ontrl room. The 8200COTIs designed to provide an witharisinglevel usinga 420 ‘mor 10-50 ma signal, which varies in direct proportion tothe liquid evel Gaugingrange | 0-60 RUB) ‘extended ange | 090K (27m) ined roof anks ony requires “ambient oF te sse0 TF Faa Cte TTS ranges ‘Materials Dependent on instalation type and pars selected ‘Shipping weight | 7OTbs (33) (nominal weight increases with vious) ‘approvals wee Cerca Number: FOBATExO009 (FT) provides data from the tank es tentona) 2520 ATG Product gravity | O45 to 069 glee (450-650 kal) ange specie gravity Service ating | Atmospheric to 150 PSI 034 KPa) or S00 P51 (20684) ge pressure ‘Gaugingrange | 0- eR GBR) “Ambient WF io 60 F(a Ce TO temperature ‘Matera Dependent on installation type and pars selected ‘Shipping weight | 1801bs (62a) t0 250 004) ‘approvals 5 All Medel (optional 150 and 220 Psi (15 Bar) Gauge version conforms To ATEK class, Zone 2x11 2675) on Technical information 2500/2520 ATS 2500 ATG Order Codes Notel_ For utagereading, pease spciy "OUT" forexamle N260001-155 (OUT. For outage versions wth metic unit, please contact he factory. Notel_ For asphalt applications, pease specify "AP, fr example N2S00D- Note! Foran IP cortfed gouge speify"PES, such as N2S00% TSS IPS. Notel_Allpaserignate in US. and confor to ATEX; Ex112G,Ta= 40°C 085°C Note! Foran iron Gaugehesd for usein pressurized apaleavons uote 20 English Configuration ‘Aluminum Gaugehead with Negator Motor 30 Tank Type }T02 | standars service cone roof tank with pan & ste roa | standard service foatng rot tank laste roa | standard service tank top mounting 708. |standar service floating rot tank; no featwell Tor | standar service cone raoftank wth pan no awe frax |Moderate service cone rat tank 51 _|eeertace service cone rot tank 15-min. 5. erential 152 imertace service cone rf tank 25 mins rentis ‘Aluminum Gaugeead with loa rank Tank Type Hor | standard serve cone oof tank 70s | standard service bates take 30 [Rascoar- | [connie roa cert tron Gaugehead (ATEX Approved) 30 [tank Type j122 | Severe service cone rot tank S325, 1123. | extreme service cone root tank carp 20 }r24_ | sovere servic tank top mounting (Rasoms=—| [eon rome cegiato ‘Aluminum Gaugehead with Negator Cassette 30 [tank Type frox | Standard service cane rot tank Hro2 | standard service cone roof tank with pan & }703 | standard service eating root tank vet roa | Standard service tank top mounting Hros | standard service bolted tank th loa 1705. |stansard service eating roo! tank; no fatwel }ro7 | standard service cone roof tank & pa; no feat vet raz | Moderate service cone roof tak 755. | suing wetlservic cone root tank Metric Configuration ‘Aluminum Gaugehead with Negator Motor 10 Tank Type frit | tondard serve cone roof tank fri2 standard service cone oof ank with pan & lst we 113 | standard service Roting oof tank wth flatwall ria | standard service tank top mounting ris | standard service bolted tank ris. standard service fating roof tank no leatwall Hru7 | tandara service cone oof tank wth pan; na awa fra2 | moderate service cone rot tank rsa |inertace service cone roof tank; 25min. dt. ret 1755. |stting wall serve cone oof tank "da. feat ae ‘Aluminum Gaugehead with Float Crank Tank Type fan. [Standard seve cone root ane a i 3 lon Gaugehead (ATEX Approved) 0 Tank Type 31 |evere servic cone root tank 132 | severe service ane top mounting 133. Jestreme sence cone roof tank: morel 134 |estreme service cone rof tank car.20 ‘Aluminum Gaugehead with Negator Cassette 0 Tonk Type rir [standard serviee cone root tank 112 | standard service cone roo tank with pan oaswe 113 | standard service Noting oof tank & oatwll ria | standard service tank top mounting H116 standard service floating roof tank: no toate [117 _| standard service cone rf tank & panne ea wel jr42 [Moderate service cone rot tank 156 siting wel service cone roo tank 16 ‘ares ne. Automatic Tank Gauge 2520 ATG Order Codes 150 PSI (10.3 Bar) Gage Steel Gaugehead 30 30 220 PSI (15 Bar) Gage Stee! Gaugehead Measurement Unit ot [Enasn Jo2 | verre Tank Type fo | 26% ameter or sphere or cylinger Tanks 02 | 48 fe Damere or sphere or cylinder Tanks 03 |Top Mounting on sphere o ender Tanks 08 | 60% Oameser or sphere or cylinder Tanks Plug vate 0 Pug vaivenotusea 1 |" (38m) 150 5: (20:3 Bar) Gage Plug ave (itn A pl) Transmitter Adapter et denraton Measurement Units Tank ¥ 05 | 161. Oameter or sphere or cylinder Tanks 06 | 481 oameter or sphere or eyinger Tans 107 | Top Mounting on sphere or einer Tanks 708 | 601 ameter or phere or eyinger Tas Plug Vale Jo. Pug ave not usee | 2 a8 mm) 220° (2583 Gage Pug valve (ton =A lg) Transmiter Adapter Note! 150(10.3 Bar) and 220 I (15 Bar) Gage version conforms to [ATEX, Class Zone 2 (Ex 1126 15) 300 PSI (20.6 Bar) Gage Steel Gaugehead » Measurement Units or Foetsh Tank Type Fos | 16. Diameter or sphere or elinderTerks 70s | 48 Diameter orsahere orclinderTenks 707 J Toe Mounting on sphere or cinder Tanks Tos | 0. Diameter or sphere or cylinder Tenks Plug Valve Jo [Plug vate not used 1 | 29 38.) 3000S (20.8837 Gage Pug valve (Viton Ape) Transiter Adapter Jo | ransmitte Adapter Not Use Technical information v 2500/2520 Automatic Tank Gauge 2500 ATG Product Dimensions te ] re ATG Product Dimensions

Anda mungkin juga menyukai