Anda di halaman 1dari 9

Module - Advanced Structured Gridding

Areal Grid Special Controls


Advanced Fault Handling
IJK faults
Reverse Faults
Fault Review

Advanced FloGrid

Advanced

Special Options - Areal & Vertical Grid Tabs


Gridding Controls, Areal & Vertical Grid
All aspects of the grid (I, J & K) can
be altered by combinations of these two
folders!

Advanced FloGrid

Advanced

Areal Grid Special Controls


Isotropic & Anisotropic
Isotropic smoothens out dog-legs
Smoothness factor
Controls the spacing and distribution of grid lines
Orthogonality factor
Produces I-J line intersections as orthogonal as possible
Honour fault end
Attempts to put a grid corner at the fault end
Tolerance setting (distance) collapses grid lines within the
vicinity of the fault end

Advanced FloGrid

Advanced

Fault Handling Overview

Vertical Coordinate Lines


Transmissibility across I & J faces only
Sloping Coordinate Lines
Cells in a column are in the same fault block
Transmissibility across I & J faces only
IJK Zigzag Stair Step
Cells in a column can be in different fault blocks
Transmissibility is across I, J & K faces

Advanced FloGrid

Advanced

Vertical Zigzag - IJK Faults


Rescue only
Faults are zigzag in cross-section (k)
Each cell in column may have different Block ID
Uses fault surface not the traces
Transmissibility across I, J and K faces
Transmissibility control via MULTNUM and MULTREGT keywords

Advanced FloGrid

Advanced

How to Set-up IJK Gridding

Y-faults, Reverse faults:

View Fault Framework to identify

Y-faults and/or Reverse faults


Set Gridding Controls to Zig-Zag
In the Vertical Gridding tab, set
Faults to IJK
FloGrid will automatically grid
complex system
Advanced FloGrid

Advanced

Reverse Fault Gridding Rescue only


To allow FloGrid to use extra k-layers to model repeat section in a reverse fault:
Gridding Control tab: reverse fault must be selected as zig-zag and set to
ignore slope
Vertical Gridding tab:
Set Fault as I, J & K faces
Set up layering as proportional with user-selected number of layers,
then click on Set Layering & note the total number of layers
Click on the Advanced Layering

Select the bottommost unit


Use Refine Selected Block Units to put in Y extra layers with 0 weight,
where: Y = #layers noted before * number of reverse faults

You will see in the log window a message about the total number of

reverse faults FloGrid has detected as well as the number it is allowed


to create

Advanced FloGrid

Advanced

Final Review: Guidelines for Modeling Faults


Sealing faults should be gridded using I or J control

lines/polygons
Truncated cell option available (snap-to-fault)
Non-sealing faults can be zigzag
Use IJK zig-zag option for Y faults, intersecting faults
Slope grid along reverse faults or use special IJK-Reverse
Consider HC zone while choosing slope
Noisy fault surface can affect IJK fault gridding

Advanced FloGrid

Advanced

End of Module

Master Presenta
tion

Advanced FloGrid

Advanced

Anda mungkin juga menyukai