Anda di halaman 1dari 139

ANTENNA &

SUBSYSTEM
Product Catalogue 2016

Legal Disclaimer
Comba Telecom Ltd retains copyright on all the text, graphics and trademarks displayed on this paper. All the text,
graphics and trademarks displayed on this paper are owned by Comba Telecom Ltd and used under licence by
Comba affiliates.
You may print copies of the information on this paper and store the files on your computer for your personal use. You
may not distribute text or graphics to others without the express written consent of Comba Telecom Ltd and Comba
affiliates. Also, you may not, without our permission, copy and distribute this information on any other server, or modify
or reuse text or graphics on this or any other system.
No reproduction of any part of the paper may be sold or distributed for commercial gain, nor shall it be modified or
incorporated in any other work, publication or site, whether in hardcopy or electronic format, including postings to any
other site. Comba Telecom Ltd reserves all other rights.
The information on this paper had been included in good faith and is for general purposes only. It should not be
realised upon for any specific purpose and no representation or warranty is given as regards to its accuracy or
completeness.
No Information on this paper shall constitute an invitation to invest in Comba Telecom Ltd or any of its affiliates.
Neither Comba Telecom Ltd and Comba affiliates, nor their or their affiliates' officers, employees or agents shall be
liable for any loss, damages or expenses arising out of any access to or use of this paper or any site linked to it,
including, without limitation, any loss of profit, indirect, incidental or consequential loss.

About Us
Comba Telecom is a leading supplier of infrastructure and wireless enhancement solutions to mobile operators and
enterprises to enhance and extend their wireless communications networks. Established in 1997, and listed on the
Hong Kong Stock Exchange in 2003, it has grown to become a global supplier with its extensive distribution network
and 60+ offices globally.

With seasoned team of research and development engineers and its state-of-the-art design tools and testing
equipment, Comba is able to provide its innovative patented designs and yet cost-effective products to the customers.
It has a largest far field microwave anechoic chamber in the region. With the complimentary of SATIMO 128 probes of
near field testing range, it can provide fast and accurate testing results to verify and ensure the product design.
Comba test ranges have been used by many customers around the world as accredited testing facilities for antenna
performance benchmarking.
Comba Antenna & Subsystem Business Unit offers full range of wireless antenna and RF conditioning products for
cellular systems, which include:
Base Station Antenna
Indoor Antenna
Remote Electrical Tilt System
RF Conditioning Products
Comba is committed to quality consistency and environmental protection and is ISO9001 and ISO14001 certified. With
its highly efficiency production lines in China and strict process control system, Combas manufacturing facility is able
to deliver high volume products with consistent quality.

Comba Manufacturing Facility in Guangzhou, China

Comba R&D Centre in Guangzhou, China

Antenna Naming Convention

ODV2 - 065R18Jxx-G
Radome Material
Pre-configured Tilt ()
Frequency Band
Gain (dBi)
Polarization
Horizontal Beamwidth ()
Categories
Antenna type
Environment Class

Antenna type

Variable Electrical Downtilt

Radome Material

OA

Omni-directional

FET Antenna

Fiberglass

DP

Directional panel FET antenna

VET Antenna

UV Resistant PVC

DV

Directional panel VET antenna

DI

RCU built-in VET antenna

DS

Directional smart antenna

Two Same Frequency Band

Cross polarization

DR

Smart bias tee built-in VET antenna

Three Same Frequency Band

Vertical polarization

Categories

Polarization

VH

Environment Class

Frequency Band Abbreviation


A

820~896 MHz

Indoor

B
C
D

806~960 MHz
1710~1880 MHz
2490-2700 MHz

Outdoor

790-960 MHz

1920~2170 MHz

880~960 MHz

1710~2690 MHz

1710~2170 MHz

2300~2690 MHz

698-960 MHz
806~960, 1710~2500 MHz(Indoor)
698-862 MHz(Base Station Antenna)
1850~1990 MHz

790~960, 1710~2700 MHz

600-960, 1710-4000 MHz

Vertical and Horizontal


polarization

Page 3 of 139

Combiner Naming Convention

CM FDWY4D-ODx
DC By-pass Type
Connector Type
Environmental Class
Double Units
Input Ports No. of Combiner
Frequency Band
Product Type

A
B
C
D
E
F
G
H
I
K

Frequency Band
L
698-894
P
806~960
R
824~894
1710~1880
T
880~960
380-960
U
890~960
W
698-3800
Y
806-1880
Z
1710~2170

2400-2500
1850-1990
698-2700
1880-1920
2010-2025
2300-2400
>3000
1920-2170
2300-2700
47-2700

x
S

DC By-pass Type
1: No DC Path
2,3,,8: DC path at Low Band/High Band
DC Autosense

Environmental Class
O
Outdoor
I
Indoor

Product Type
CM

Combiner

D
N
S

Connector Type
DIN Connector
N Connector
SMA Connector

Page 4 of 139

Passive Component Naming Convention

DC R06 OD500C(H)
PIM Level
Design Technique
Power Handling
Connector Type
Environmental Class
Coupling Value / Splitting Way
Frequency Band
Product Type

A
B
C
D
E
F
G
H
I
K

Frequency Band
L
698-894
P
806~960
R
824~894
1710~1880
T
880~960
380-960
U
890~960
W
698-3800
Y
806-1880
Z
1710~2170

2400-2500
1850-1990
698-2700
1880-1920
2010-2025
2300-2400
>3000
1920-2170
2300-2690
47-2700

DC
CO
PS
HC
FP

Product Type
Direction Coupler
Coupler
Power Splitter
Hybrid Coupler
Filter

M
C
L

Design Technique
Microstrip
Coaxial Cavity
Stripline

Environmental Class
O
Outdoor
I
Indoor
Connector Type
D
DIN Connector
N
N Connector

(H)
(XH)

PIM Level
-150dBc
-153dBc

Page 5 of 139

Base Station Antenna ........................................................ 7


Indoor Antenna................................................................. 76
RET System ...................................................................... 84
RF Product ........................................................................ 90

Page 6 of 139

Base Station Antenna

Page 7 of 139

Base Station Antenna


Multiple-beam Antenna .................................................................................................................................................................................. 11
XX-Pol
ODDV-032R20K-G............................................................................................................................................................................... 12

XXX-Pol
ODTP-024R20K06-G ........................................................................................................................................................................... 13

V-Pol & X-Pol Antenna ................................................................................................................................................................................... 14


V-Pol
ODP-065V11N ..................................................................................................................................................................................... 15

698-960MHz
ODV-065R15M-G................................................................................................................................................................................. 16
ODV-065R16M-G................................................................................................................................................................................. 17

790-960MHz
ODV-032R18E-G ................................................................................................................................................................................. 18
ODV-032R20E-G V1 ............................................................................................................................................................................ 19
ODV-065R15E-G ................................................................................................................................................................................. 20
ODV-065R17E-G ................................................................................................................................................................................. 21
ODV-065R18E ..................................................................................................................................................................................... 22
ODV-090R17E-G ................................................................................................................................................................................. 23

1710-2170MHz
ODV-032R21K-G ................................................................................................................................................................................. 24
ODV-032R23K-G V1 ............................................................................................................................................................................ 25
ODV-065R15K-G ................................................................................................................................................................................. 26
ODV-065R18K-G V1 ............................................................................................................................................................................ 27
ODV-065R21K-G ................................................................................................................................................................................. 28
ODV-090R17K-G ................................................................................................................................................................................. 29

1710-2690MHz
ODV-065R18J-G .................................................................................................................................................................................. 30

Page 8 of 139

XX-Pol Antenna .............................................................................................................................................................................................. 31


698-960MHz/1710-2690MHz
ODP-065R12M14J-G ........................................................................................................................................................................... 32
ODV-065R14M17J-G ........................................................................................................................................................................... 33
ODV-065R15M18J-G ........................................................................................................................................................................... 34
ODV-065R16M18J-G ........................................................................................................................................................................... 35

806-960MHz/1710-2690MHz
ODP-065R09BJ-G ............................................................................................................................................................................... 36
ODP-065R09BJ-G(2J) ......................................................................................................................................................................... 37

790-960MHz/1710-2170MHz
ODV-065R15E18K-G V2...................................................................................................................................................................... 38
ODV-065R17E18K-G V1...................................................................................................................................................................... 39
ODV-065R18EK-G ............................................................................................................................................................................... 40

790-960MHz/1710-2690MHz
ODV-065R17E18J-G............................................................................................................................................................................ 41
ODV-065R18EJ-G ............................................................................................................................................................................... 42

790-960MHz/790-960MHz
ODV2-065R17E-G ............................................................................................................................................................................... 43

1710-2170MHz/1710-2170MHz
ODV2-065R18K-G V2 .......................................................................................................................................................................... 44
ODV2-065R21K-G V1 .......................................................................................................................................................................... 45

1710-2690MHz/1710-2690MHz
ODV2-065R16J-G ................................................................................................................................................................................ 46
ODV2-065R18J-G V1........................................................................................................................................................................... 47

XXX-Pol Antenna ............................................................................................................................................................................................ 48


698-960MHz/1710-2690MHz/1710-2690MHz
ODP-065R12M14JJ-G ......................................................................................................................................................................... 49
ODV-065R14M17JJ-G ......................................................................................................................................................................... 50
ODV-065R15M18JJ-G ......................................................................................................................................................................... 51
ODV-065R16M18JJ-G ......................................................................................................................................................................... 52
ODV-065R17M18JJ-G ......................................................................................................................................................................... 53

790-960MHz/1710-2170MHz/1710-2170MHz
ODV-065R15EKK ................................................................................................................................................................................ 54
ODV-065R15E18KK-G V2 ................................................................................................................................................................... 55
ODV-065R17E18KK-G V1 ................................................................................................................................................................... 56
ODV-065R18EKK-G ............................................................................................................................................................................ 57

790-960MHz/1710-2690MHz/1710-2690MHz
ODV-065R15EJJ.................................................................................................................................................................................. 58
ODV-065R17EJJ-G.............................................................................................................................................................................. 59
ODV-065R18EJJ-G.............................................................................................................................................................................. 60

Page 9 of 139

1710-2170MHz/1710-2170MHz/1710-2170MHz
ODV3-065R18K-G V1 .......................................................................................................................................................................... 61

1710-2690MHz/1710-2690MHz/1710-2690MHz
ODI3-065R15J-G ................................................................................................................................................................................. 62
ODV3-065R18J-G V1........................................................................................................................................................................... 63

XXXX-Pol Antenna .......................................................................................................................................................................................... 64

698-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz
ODV-065R17M18JJJ-G ....................................................................................................................................................................... 65

698-862MHz/880-960MHz/1710-2690MHz/1710-2690MHz
ODI-065R15NG18JJ-G ........................................................................................................................................................................ 66

790-960MHz/1710-2170MHz/1710-2690MHz/1710-2690MHz
ODI-065R12E15KJJ-G ......................................................................................................................................................................... 67
ODI-065R15E18KJJ-G ......................................................................................................................................................................... 68
ODV-065R17EKJJ-G ........................................................................................................................................................................... 69

790-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz
ODV-065R17E18JJJ-G ........................................................................................................................................................................ 70

790-960MHz/790-960MHz/1710-2690MHz/1710-2690MHz
ODV2-065R17E18J-G.......................................................................................................................................................................... 71

XXXXX-Pol Antenna ........................................................................................................................................................................................ 72


698-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz
ODV-065R17M18JJJJ-G...................................................................................................................................................................... 73

698-806MHz/824-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz
ODI-065R16NB17JJJ-G ....................................................................................................................................................................... 74

790-960MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz/1710-2690MHz
ODV-065R17E18JJJJ-G ...................................................................................................................................................................... 75

Page 10 of 139

Multiple-beam Antenna
Model

Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Length
(mm)

ODDV-032R20K-G

XX-Pol

1710-2170 / 1710-2170

19.9 / 19.9

32

0-10 / 0-10

1340

ODTP-024R20K06-G

XXX-Pol

1710-2170 / 1710-2170 / 1710-2170

20.1 / 20.1 /
20.1

24

6/6/6

840

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0216

Page 11 of 139

Outdoor Directional Twin-beam Antenna


ODDV-032R20K-G
XX Pol, 32
1710-2170/1710-2170MHz
19.9/19.9dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beam Centers ()
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

1850-1990
45
19.5
-28,+28
33
6.9
0-10 / 0-10
19(0)
17(5)
15(10)
25
15
1.5:1
16
28
<-150
300
50

19.2
-32,+32
36
7.2

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @boresight (dB)
VSWR
Beam Isolation (dB)
Cross-polar Isolation (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
19.9
-27,+27
31
6.3

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1340x320x110 / 52.8x12.6x4.3
15.3 / 33.7
20.9 / 46.1
Fiberglass, Light Grey
00-ZJ10(16)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

582 / 89 / 676
1640x430x215 / 64.6x16.9x8.5
26.0 / 57.3
Direct Ground

* TIA-222-G

Connector Position

1710-2170
+45

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0216

Page 12 of 139

Outdoor Directional Tri-beam Antenna


ODTP-024R20K06-G
XXX Pol, 24
1710-2170/1710-2170/1710-2170MHz
20.1/20.1/20.1dBi, FET: 6/6/6

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beam Centers ()
Horizontal Beamwidth ()
Vertical Beamwidth ()
Fixed Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @boresight (dB)
VSWR
Beam Isolation (dB)
Cross-polar Isolation (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2170
1850-1990
45
19.4
-30,0,+30
24
11.5
6/6/6
16
26
15
1.5:1
16
25
<-150
300
50

18.8
-33,0,+33
26
12.0

1710-2170
1920-2170
20.1
-28,0,+28
24
11.0

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
840x380x138 / 33.1x15.0x5.4
11.9 / 26.2
14.7 / 32.4
Fiberglass, Light Grey
00-ZJ15A(25)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200
345 / 67 / 411
19.8 / 43.7
1110x490x260 / 43.7x19.3x10.2
Direct Ground

* TIA-222-G

Connector Position

1710-2170
+45

1710-2170
-45
1710-2170
+45

1710-2170
-45

DIN 7/16 F

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-0 / 0116

Page 13 of 139

V-Pol & X-Pol Antenna


Model

Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Length
(mm)

ODP-065V11N

V-Pol

698-960 / 1710-2700

10.6 / 11.0

65

610

ODV-065R15M-G

X-Pol

698-960

14.8

65

VET 0-14

1450

ODV-065R16M-G

X-Pol

698-960

15.8

65

VET 0-10

2000

ODV-032R18E-G

X-Pol

790-960

17.6

32

VET 0-20

1415

ODV-032R20E-G V1

X-Pol

790-960

19.2

32

VET 0-11

1970

ODV-065R15E-G

X-Pol

790-960

15.0

65

VET 0-16

1315

ODV-065R17E-G

X-Pol

790-960

16.6

65

VET 0-10

1975

ODV-065R18E

X-Pol

790-960

17.5

65

VET 0-12

2615

ODV-090R17E-G

X-Pol

790-960

16.5

90

VET 0-12

2615

ODV-032R21K-G

X-Pol

1710-2170

20.5

32

VET 0-10

1310

ODV-032R23K-G-V1

X-Pol

1710-2170

22.0

32

VET 0-8

1960

ODV-065R15K-G

X-Pol

1710-2170

15.0

65

VET 0-20

680

ODV-065R18K-G V1

X-Pol

1710-2170

17.8

65

VET 0-10

1335

ODV-065R21K-G

X-Pol

1710-2170

19.5

65

VET 0-8

1960

ODV-090R17K-G

X-Pol

1710-2170

16.3

90

VET 0-10

1310

ODV-065R18J-G

X-Pol

1710-2690

17.8

65

VET 0-12

1365

Page 14 of 139

Outdoor Directional Panel Antenna


ODP-065V11N
V Pol, 65
698-960/1710-2700MHz
10.6/11.0dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-800

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Front-To-Back Ratio 18030(dB)
VSWR
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2700
800-960

1710-2200

2200-2700

10.5
67
33

11.0
66
33

Vertical
10.5
70
30

10.6
67
28
20
1.5:1
<-153
100
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)

Specifications

Weight, w/o Mounting Kit (kg) / (lb)

6.4 / 14.1

Weight, with Mounting Kit (kg) / (Ib)

9.3 / 20.5

Radome Material and Color


Mounting Kit
Connector Type and Location

Fiberglass, White
00-ZJ15A(32)
1 x 7/16 DIN-Female, Bottom

Operational Temperature (C)

-50 to +70

Operational Humidity (%)


Operational/Max Wind Speed (mi/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)

Product Picture

610x320x145 / 24.0x12.6x5.7

95
93.2 / 124.3
180 / 50 / 225
890x430x260 / 28.5x16.9x10.2

Shipping Weight (kg) / (Ib)


Lightning Protection

11.4 / 25.1
Direct Ground

* TIA-222-G

Connector Position

698-2700

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-1 / 0116

Page 15 of 139

Outdoor Directional Single-band Antenna


ODV-065R15M-G
X Pol, 65
698-960MHz
14.8dBi, E-Tilt: 0-14

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-824

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

790-896
45
14.4
65
13.8
0-14
16(0)
15(7)
14(14)
25
17
1
1.5:1
30
<-150
500
50

14.0
69
15.4

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

880-960
14.8
61
12.6

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (lb)
Lightning Protection

Specifications
1450x320x145 / 57.1x12.6x5.7
13.7 / 30.2
18.7 / 41.2
Fiberglass, Light Grey
SJA-B-12R(17)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

506 / 126 / 641


1770x430x270 / 69.7x16.9x10.6
25.0 / 55.1
Direct Ground

* TIA-222-G

Connector Position

698-960
-45

698-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-4 / 0116

Page 16 of 139

Outdoor Directional Single-band Antenna


ODV-065R16M-G
X Pol, 65
698-960MHz
15.8dBi, E-Tilt: 0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-824

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

790-896
45
15.7
64
9.6
0-10
17(0)
16(5)
15(10)
25
17
1
1.5:1
30
<-150
500
50

15.2
68
10.8

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

880-960
15.8
61
8.9

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2000x320x145 / 78.7x12.6x5.7
17.0 / 37.5
23.3 / 51.4
Fiberglass, Light Grey
00-ZJ11(08)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

751 / 173 / 960


2340x430x270 / 92.1x16.9x10.6
31.0 / 68.4
Direct Ground

* TIA-222-G

Connector Position

698-960
-45

DIN 7/16 F

698-960
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0815

Page 17 of 139

Outdoor Directional Single-band Antenna


ODV-032R18E-G
X Pol, 32
790-960MHz
17.6dBi, E-Tilt: 0-20

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

17.0
34
15.0

17.6
32
13.9
0-20
17(0)
16(10)
16(20)
25
17
1
2
1.5:1
30
<-150
500
50

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
Squint ()
VSWR
Isolation between Ports(dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1415x500x140 / 55.7x19.7x5.5
28.0 / 61.7
34.3 / 75.6
Fiberglass, Light Grey
00-ZJ11(16)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

925 / 113 / 1118


1765x635x305 / 69.5x25.0x12.0
38.0 / 83.8
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-4 / 0116

Page 18 of 139

Outdoor Directional Single-band Antenna


ODV-032R20E-G V1
X Pol, 32
790-960MHz
19.2dBi, E-Tilt: 0-11

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

18.5
34
10.4
0-11
18(0)
17(6)
16(11)
15

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
Squint ()
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

19.2
32
9.5

25

28
17
1
2
1.5:1
30
<-150
500
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1970x500x140 / 77.6x19.7x5.5
30.6 / 67.5
40.9 / 90.2
Fiberglass, Light Grey
00-ZJ11(12) (three mounting points)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1397 / 162 / 1735


2330x635x305 / 91.7x25.0x12.0
52.6 / 116.0
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

DIN 7/16 F

790-960
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0116

Page 19 of 139

Outdoor Directional Single-band Antenna


ODV-065R15E-G
X Pol, 65
790-960MHz
15.0dBi, E-Tilt: 0-16

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

14.5
67
16.0

15.0
63
14.5
0-16
18(0)
16(8)
16(16)
25
17
3
1.5:1
30
<-150
500
50

st

1 Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination@0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Connector Type and Location
Mounting Kit
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1315x265x120 / 51.8x10.4x4.7
11.3 / 24.9
16.3 / 35.9
Fiberglass, Light Grey
2 x 7/16 DIN-Female, Bottom
SJA-B-12R(16)
-50 to +70
95
150 / 200

Product Picture

376 / 96 / 444
1625x375x250 / 64.0x14.8x9.8
20.8 / 45.9
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-5 / 0116

Page 20 of 139

Outdoor Directional Single-band Antenna


ODV-065R17E-G
X Pol, 65
790-960MHz
16.6dBi, E-Tilt: 0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

16.0
66
10.2

16.6
63
9.3
0-10
17(0)
16(5)
16(10)
15(typ.)
25
20
2
1.5:1
30
<-150
500
50

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1975x265x120 / 77.8x10.4x4.7
17.0 / 37.5
22.6 / 49.8
Fiberglass, Light Grey
00-ZJ10(12)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

597 / 150 / 716


2285x375x250 / 90.0x14.8x9.8
26.0 / 57.3
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

DIN 7/16 F

790-960
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-3 / 0116

Page 21 of 139

Outdoor Directional Single-band Antenna


ODV-065R18E
X Pol, 65
790-960MHz
17.5dBi, E-Tilt: 0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

17.0
67
7.7

17.5
64
7.2
0-12
18(0)
17(6)
16(12)
25
17
2
1.5:1
30
<-150
500
50

st

1 Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2615x265x120 / 103.0x10.4x4.7
20.5 / 45.1
26.1 / 57.4
UV Resistant PVC, Light Grey
00-ZJ10(08)
2 x 7/16 DIN-Female, Bottom
-40 to +60
95
150 / 200

Product Picture

814 / 201 / 972


2915x375x250 / 114.8x14.8x9.8
34.0 / 75.0
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0116

Page 22 of 139

Outdoor Directional Single-band Antenna


ODV-090R17E-G
X Pol, 90
790-960MHz
16.5dBi, E-Tilt: 0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960
790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

16.0
85
7.8

16.5
84
7.0
0-12
18(0)
16(6)
16(12)
14
25
17
1
1.5:1
30
<-150
500
50

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2615x265x145 / 103.0x10.4x5.7
24.3 / 53.6
29.9 / 65.9
Fiberglass, Light Grey
00-ZJ10(08)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

837 / 289 / 829


2915x375x275 / 114.8x14.8x10.8
37.2 / 82.0
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-3 / 0116

Page 23 of 139

Outdoor Directional Single-band Antenna


ODV-032R21K-G
X Pol, 32
1710-2170MHz
20.5dBi, E-Tilt: 0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1850-1990
45
20.2
30
6.6
0-10
18(0)
17(5)
16(10)
27(typ.)
18
1
2
1.5:1
30
<-150
300
50

19.6
32
7.1

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
Squint ()
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
20.5
28
6.2

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1310x265x90 / 51.6x10.4x3.5
13.5 / 29.8
18.5 / 41.0
Fiberglass, Light Grey
SJA-B-12R(16)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

397 / 67 / 537
1595x375x215 / 62.8x14.8x8.5
23.5 / 51.8
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0116

Page 24 of 139

Outdoor Directional Single-band Antenna


ODV-032R23K-G V1
X Pol, 32
1710-2170MHz
22.0dBi, E-Tilt: 0-8

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1850-1990
45
21.6
31
4.6
0-8
17(0)
16(4)
15(8)
28(typ.)
17
2
1.5
1.5:1
30
<-150
300
50

21.2
33
5.0

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
Squint ()
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
22.0
30
4.4

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1960x265x90 / 77.2x10.4x3.5
15.1 / 33.3
20.7 / 45.6
Fiberglass, Light Grey
00-ZJ10(12)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

641 / 103 / 866


2245x375x215 / 88.4x14.8x8.5
25.5 / 56.2
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0116

Page 25 of 139

Outdoor Directional Single-band Antenna


ODV-065R15K-G
X Pol, 65
1710-2170MHz
15.0dBi, E-Tilt: 0-20

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

14.7
68
14.5

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1850-1990
45
14.7
65
13.9
0-20
17(0)
16(10)
15(20)
25(0-15o), 23(15-20o )(typ.)
17
1.5:1
28
<-150
300
50

1920-2170
15.0
63
13.0

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
680x145x86 / 26.8x5.7x3.4
4.5 / 9.9
6.5 / 14.3
Fiberglass, Light Grey
SJA-B-14E(20)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

118 / 46 / 119
875x225x180 / 34.5x8.9x7.1
8.0 / 17.6
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-3 / 0116

Page 26 of 139

Outdoor Directional Single-band Antenna


ODV-065R18K-G V1
X Pol, 65
1710-2170MHz
17.8dBi, E-Tilt: 0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1850-1990
45
17.5
68
6.8
0-10
18(0)
17(5)
16(10)
25
17
2
1.5:1
30
<-150
300
50

17.1
69
7.2

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @ 0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
17.8
65
6.3

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1335x120x60 / 52.6x4.7x2.4
5.8 / 12.8
7.5 / 16.5
Fiberglass, Light Grey
SJA-B-14F(12)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

223 / 67 / 229
1565x190x130 / 61.6x7.5x5.1
8.5 / 18.7
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0116

Page 27 of 139

Outdoor Directional Single-band Antenna


ODV-065R21K-G
X Pol, 65
1710-2170MHz
19.5dBi, E-Tilt: 0-8

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1850-1990
45
19.2
65
4.5
0-8
17(0)
16(4)
15(8)
25
18
3
3
1.5:1
30
<-150
300
50

19.0
67
4.6

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @ 0(dB)
Beam Tracking Avg. (dB)
Squint ()
VSWR
Isolation between Ports (dB)
IM3 (2x43dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
19.5
63
4.2

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1960x145x86 / 77.2x5.7x3.4
10.6 / 23.4
13.4 / 29.5
Fiberglass, Light Grey
00-ZJ15(12)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

394 / 164 / 401


2350x225x185 / 92.5x8.9x7.3
17.2 / 37.9
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-4 / 0116

Page 28 of 139

Outdoor Directional Single-band Antenna


ODV-090R17K-G
X Pol, 90
1710-2170MHz
16.3dBi, E-Tilt: 0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1850-1990
45
16.3
88
6.8
0-10
18(0)
17(5)
16(10)
25(typ.)
17
2
1.5:1
30
<-150
300
50

16.2
86
7.2

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
16.3
90
6.3

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1310x145x86 / 51.6x5.7x3.4
6.5 / 14.3
8.2 / 18.1
Fiberglass, Light Grey
SJA-B-14D(10)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

250 / 103 / 258


1490x225x170 / 58.7x8.9x6.7
10.8 / 23.8
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0116

Page 29 of 139

Outdoor Directional Single-band Antenna


ODV-065R18J-G
X Pol, 65
1710-2690MHz
17.8dBi, E-Tilt: 0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications
Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2690
1710-1880

1850-1990

17.0
65
7.4

17.3
63
7.0

1920-2170
45
17.6
62
6.6
0-12

18(0)
16(6)
15(12)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

2300-2500

2490-2690

17.6
64
5.6

17.8
62
5.2
17(0)
16(6)
15(12)

25(typ.)
18(typ.)
2
1.5:1
28
<-150
250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (oC)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1365x160x83 / 53.7x6.3x3.3
9.2 / 20.3
11.2 / 24.7
Fiberglass, Light Grey
SJA-B-14E(10)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

305 / 111 / 310


1560x230x170 / 61.4x9.1x6.7
14.0 / 30.9
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-4 / 0116

Page 30 of 139

XX-Pol Antenna
Model

Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Length
(mm)

ODP-065R12M14J-G

XX-Pol

698-960 / 1710-2690

12.0 / 15.6

65

FET 0 / FET 0

650

ODV-065R14M17J-G

XX-Pol

698-960 / 1710-2690

13.9 / 16.8

65

VET 0-14 /
VET 0-10

1280

ODV-065R15M18J-G

XX-Pol

698-960 / 1710-2690

14.6 / 17.5

65

VET 0-14 /
VET 0-10

1610

ODV-065R16M18J-G

XX-Pol

698-960 / 1710-2690

15.4 / 17.5

65

VET 0-10 /
VET 0-10

1975

ODP-065R09BJ-G

XX-Pol

806-960 / 1710-2690

7.8 / 8.4

65

FET 0 / FET 0

340

ODP-065R09BJ-G(2J)

XX-Pol

806-960 / 1710-2690

7.8 / 8.4

65

FET 0 / FET 0

340

ODV-065R15E18K-G V2

XX-Pol

790-960 / 1710-2170

14.8 / 17.2

65

VET 0-14 /
VET 0-10

1480

ODV-065R17E18K-G V1

XX-Pol

790-960 / 1710-2170

16.5 / 17.3

65

VET 0-10 /
VET 0-10

1940

ODV-065R18EK-G

XX-Pol

790-960 / 1710-2170

17.0 / 17.5

65

VET 0-10 /
VET 0-10

2515

ODV-065R17E18J-G

XX-Pol

790-960 / 1710-2690

16.1 / 18.0

65

VET 0-10 /
VET 0-10

2000

ODV-065R18EJ-G

XX-Pol

790-960 / 1710-2690

17.0 / 18.0

65

VET 0-10 /
VET 0-10

2765

ODV2-065R17E-G

XX-Pol

790-960 / 790-960

16.5 / 16.5

65

VET 0-10 /
VET 0-10

1970

ODV2-065R18K-G V2

XX-Pol

1710-2170 / 1710-2170

17.8 / 17.8

65

VET 0-10 /
VET 0-10

1310

ODV2-065R21K-G V1

XX-Pol

1710-2170 / 1710-2170

19.0 / 19.0

65

VET 0-8 /
VET 0-8

1960

ODV2-065R16J-G

XX-Pol

1710-2690 / 1710-2690

15.6 / 15.6

65

VET 0-12 /
VET 0-12

810

ODV2-065R18J-G V1

XX-Pol

1710-2690 / 1710-2690

17.9 / 17.9

65

VET 0-10 /
VET 0-10

1400

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-1 / 1214

Page 31 of 139

Outdoor Directional Dual-band Antenna


ODP-065R12M14J-G
XX Pol, 65
698-960/1710-2690MHz
12.0/15.6dBi, FET: 0/0

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Fixed Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

698-824

790-894

880-960

11.4
74
28.8

11.8
74
26.4
0
/

12.0
73
24.1

1710-1990
45
14.9
65
13.6

1920-2170

2490- 2690

15.2
61
12.3
0
14

15.6
65
9.8

25(typ.)
17
1.5:1
25
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (oC)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
650x320x145 / 25.6x12.6x5.7
8.8 / 19.4
10.8 / 23.8
Fiberglass, Light Grey
SJA-B-14E(20)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

192 / 53 / 240
850x430x260 / 33.5x16.9x10.2
13.0 / 28.7
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

698-960
-45

698-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 32 of 139

Outdoor Directional Dual-band Antenna


ODV-065R14M17J-G
XX Pol, 65
698-960/1710-2690MHz
13.9/16.8dBi, E-Tilt: 0-14/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690

698-824

790-894

880-960

13.1
72
17.7

13.5
72
16.0
0-14
17(0)
16(7)
14(14)

13.9
68
14.3

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
16.0
65
10.4

1920-2170

2490-2690

16.5
62
9.4
0-10
16(0)
15(5)
14(10)

16.8
61
7.4

25
17
2
1.5:1
26

26
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1280x320x145 / 50.4x12.6x5.7
13.5 / 29.8
19.1 / 42.1
Fiberglass, Light Grey
00-ZJ10(16)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

434 / 109 / 550


1585x430x270 / 62.4x16.9x10.6
23.0 / 50.7
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

698-960
-45

698-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Page 33 of 139

Outdoor Directional Dual-band Antenna


ODV-065R15M18J-G
XX Pol, 65
698-960/1710-2690MHz
14.6/17.5dBi, E-Tilt: 0-14/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690

698-824

790-894

880-960

14.2
68
15.0

14.5
68
13.6
0-14
16(0)
15(7)
14(14)

14.6
67
12.2

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
16.5
64
7.3

1920-2170

2490-2690

17.1
63
6.6
0-10
16(0)
15(5)
14(10)

17.5
65
5.0

25(typ.)
17(typ.)
1.5:1
25

28
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1610x320x145 / 63.4x12.6x5.7
17.5/ 38.6
23.1/ 50.7
Fiberglass, Light Grey
00-ZJ10(12)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

574 / 140 / 729


1915x430x270 / 75.4x16.9x10.6
29.0 / 63.9
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

698-960
-45

698-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:1-0-4 / 1215

Page 34 of 139

Outdoor Directional Dual-band Antenna


ODV-065R16M18J-G
XX Pol, 65
698-960/1710-2690MHz
15.4/17.5dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690

698-824

790-894

880-960

14.9
67
11.0

15.3
65
10.1
0-10
17(0)
15(5)
14(10)

15.4
62
9.5

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
16.7
63
6.5

1920-2170

2490-2690

17.2
61
5.9
0-10
16(0)
16(5)
14(10)

17.5
63
4.8

25(typ.)
17
2
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (Kg) / (lb)
Lightning Protection

Specifications
1975x320x145 / 77.8x12.6x5.7
21.5 / 47.4
27.1 / 59.5
Fiberglass, Light Grey
00-ZJ10(12)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

740 / 172 / 945


2280x430x270 / 89.8x16.9x10.6
35.0 / 77.2
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

698-960
-45

698-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:1-0-3 / 1215

Page 35 of 139

Outdoor Directional Dual-band Antenna


ODP-065R09BJ-G
XX Pol, 65
806-960/1710-2690MHz
7.8/8.4dBi, FET: 0/0

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

806-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Fixed Electrical Downtilt ()
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

806-894

880-960

7.6
69
70

7.8
65
64

1710-1990
45
8.2
60
56

1920-2170

2490- 2690

8.3
59
61
0

8.4
68
65

20
15
1.5:1
25
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (oC)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
340x265x120 / 13.4x10.4x4.7
4.0 / 8.8
4.6 / 10.1
Fiberglass, Light Grey
00-ZJ16(20)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

80 / 24 / 94
455x340x230 / 17.9x13.4x9.1
5.6 / 12.3
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

806-960
-45

806-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-1 / 1215

Page 36 of 139

Outdoor Directional Dual-band Antenna


ODP-065R09BJ-G(2J)
XX Pol, 65
806-960/1710-2690MHz
7.8/8.4dBi, FET: 0/0

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

806-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Fixed Electrical Downtilt ()
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

806-894

880-960

7.6
69
70

7.8
65
64

1710-1990
45
8.2
60
56

1920-2170

2490- 2690

8.3
59
61
0

8.4
68
65

20
15
1.5:1
25
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (oC)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
340x265x120 / 13.4x10.4x4.7
4.5 / 9.9
5.1 / 11.2
Fiberglass, Light Grey
00-ZJ16(20)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

80 / 24 / 94
455x340x230 / 17.9x13.4x9.1
6.1 / 13.4
Direct Ground

* TIA-222-G

Connector Position

806-960
1710-2690
-45

DIN 7/16 F

806-960
1710-2690
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-0 / 1215

Page 37 of 139

Outdoor Directional Dual-band Antenna


ODV-065R15E18K-G V2
XX Pol, 65
790-960/1710-2170MHz
14.8/17.2dBi, E-Tilt: 0-14/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

14.3
68
14.4

14.8
66
13.5

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880
45
16.9
65
7.1

0-14
18(0)
17(7)
17(14)
17(0)
16(7)
15(14)

1st Upper Sidelobe Suppression (dB)

0-30Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1850-1990

1920-2170

17.0
65
6.5
0-10
17(0)
16(5)
16(10)
16(0)
15(5)
15(10)

17.2
62
6.2

25
18
2
1.5:1
28
30
<-150
500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1480x265x120 / 58.3x10.4 x4.7
14.5/ 32.0
20.1 / 44.1
Fiberglass, Light Grey
00-ZJ10(13)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

430 / 110 / 515


1785x375x250 / 70.3x14.8x9.9
23.5 / 51.8
Direct Ground

*TIA-222-G

Connector Position

DIN 7/16 F

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:1-0-1 / 1215

Page 38 of 139

Outdoor Directional Dual-band Antenna


ODV-065R17E18K-G V1
XX Pol, 65
790-960/1710-2170MHz
16.5/17.3dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

16.0
68
10.5

16.5
65
9.8

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880
45
17.1
65
7.2

0-10
18(0)
17(5)
17(10)
15

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1850-1990

1920-2170

17.0
64
6.7
0-10
17(0)
16(5)
16(10)
15

17.3
62
6.4

25
18
2
1.5:1
29
30
<-150
500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1940x265x120 / 76.4x10.4x4.7
19.5 / 43.0
25.8 / 56.9
Fiberglass, Light Grey
00-ZJ10(14)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

584 / 147 / 701


2285x375x250 / 90.0x14.8x9.8
33.5 / 73.9
Direct Ground

* TIA-222-G

Connector Position

DIN 7/16 F

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-1 / 1215

Page 39 of 139

Outdoor Directional Dual-band Antenna


ODV-065R18EK-G
XX Pol, 65
790-960/1710-2170MHz
17.0/17.5dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

16.5
68
8.0

17.0
65
7.5

Polarization
Gain (dBi)
Horizontal Beamwidth()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880
45
17.2
67
6.6

0-10
17(0)
16(5)
15(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1850-1990

1920-2170

17.5
64
6.2
0-10
18(0)
17(5)
16(10)

17.5
63
5.8

25
17
2
1.5:1
28
30
<-150
500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2515x265x145/ 99.0x10.4x5.7
29.0 / 63.9
34.6 / 79.5
Fiberglass, Light Grey
00-ZJ10(08)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 /200

Product Picture

799 / 277 / 793


2830x375x275 / 111.4x14.8x10.8
41.0 / 90.4
Direct Ground

*TIA-222-G

Connector Position

DIN 7/16 F

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-5 / 1215

Page 40 of 139

Outdoor Directional Dual-band Antenna


ODV-065R17E18J-G
XX Pol, 65
790-960/1710-2690MHz
16.1/18.0dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

15.8
68
9.5

16.1
66
8.9

Polarization
Gain (dBi)
Horizontal Beamwidth()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1990
45
17.2
68
6.1

0-10
18(0)
17(5)
16(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
IsolationIntra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
17.6
63
5.6
0-10
17(0)
16(5)
15(10)

2490-2690
18.0
59
4.5

25(typ.)
18(typ.)
2

1
1.5:1
28
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2000x320x145 / 78.7x12.6x5.7
25.2 / 55.6
31.5 / 69.4
Fiberglass, Light Grey
00-ZJ11(08)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

751 / 173 / 960


2340x430x270 / 92.1x16.9x10.6
38.5 / 84.9
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-2 / 1215

Page 41 of 139

Outdoor Directional Dual-band Antenna


ODV-065R18EJ-G
XX Pol, 65
790-960/1710-2690MHz
17.0/18.0dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

16.6
64
6.8

17.0
62
6.0

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1990
45
16.8
68
6.1

0-10
18(0)
17(5)
16(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
17.3
64
5.6
0-10
17(0)
16(5)
15(10)

2490-2690
18.0
60
4.5

25(typ.)
18(typ.)
3
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2765x320x145 / 108.9x12.6x5.7
31.0 / 68.4
41.3 / 91.1
Fiberglass, Light Grey
00-ZJ11(08) (three mounting points)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1124 / 245 / 1401


3100x430x270 / 122.0x16.9x10.6
50.0 / 110.3
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-4 / 1215

Page 42 of 139

Outdoor Directional Dual-band Antenna


ODV2-065R17E-G
XX Pol, 65
790-960/790-960MHz
16.5/16.5dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

790-960

790-896

880-960
45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

16.0
68
10.0

16.5
63
9.2
0-10 / 0-10
18(0)
17(5)
16(10)
25
18
2
1.5:1
30
<-150
500
50

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports(dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port(W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1970x500x140 / 77.6x19.7x5.5
35.0 / 77.2
45.3 / 99.9
Fiberglass, Light Grey
00-ZJ11(12) (three mounting points)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1397 / 162 / 1735


2330x635x305 / 91.7x25.0x12.0
53.0 / 116.8
Direct Ground

*TIA-222-G

Connector Position

790-960
-45

790-960
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-2 / 1215

Page 43 of 139

Outdoor Directional Dual-band Antenna


ODV2-065R18K-G V2
XX Pol, 65
1710-2170/1710-2170MHz
17.8/17.8dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

1850-1990
45
17.5
65
7.0
0-10 / 0-10
18(0)
17(5)
16(10)
15
25
17
2
1.5:1
30
<-150
300
50

16.9
66
7.6

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
17.8
64
6.6

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1310x249x60 / 51.6x9.8x2.4
10.0 / 22.0
12.8 / 28.2
Fiberglass, Light Grey
00-ZJ15A(16)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

440 / 50 / 490
1613x367x312 / 63.5x14.4x12.3(3 in 1 Package)
43.0 / 94.8(3 in 1 Package)
Direct Ground

* TIA-222-G

Connector Position

1710-2170
+45

1710-2170
-45
1710-2170
+45

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 1215

Page 44 of 139

Outdoor Directional Dual-band Antenna


ODV2-065R21K-G V1
XXPol, 65
1710-2170/1710-2170MHz
19.0/19.0dBi, E-Tilt: 0-8/0-8

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

1850-1990
45
18.8
65
4.6
0-8 / 0-8
17(0)
16(4)
15(8)
25
18
2
1.5:1
30
<-150
300
50

18.7
67
4.9

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170
19.0
65
4.4

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1960x249x60 / 77.2x9.8x2.4
14.0 / 30.9
19.6 / 43.2
Fiberglass, Light Grey
00-ZJ10(12)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

733 / 77 / 802
2295x360x175 / 90.4x14.2x6.9
22.0 / 48.5
Direct Ground

* TIA-222-G

Connector Position

1710-2170
+45

1710-2170
-45
1710-2170
+45

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0116

Page 45 of 139

Outdoor Directional Dual-band Antenna


ODV2-065R16J-G
XX Pol, 65
1710-2690/1710-2690MHz
15.6/15.6dBi, E-Tilt: 0-12/0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2690

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880

1850-1990

14.8
69
13.6

15.0
67
12.7

1710-2690

1920-2170
45
15.0
69
12.1
0-12 / 0-12

16(0)
15(6)
14(12)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

2300-2500

2490-2690

15.3
63
9.9

15.6
65
9.5
15(0)
14(6)
13(12)

25
18(typ.)
1.5:1
26
<-150
250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
810x300x86 / 31.9x11.8x3.4
11.0 / 24.3
16.2 / 35.7
Fiberglass, Light Grey
SJA-B-12R(28)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

322 / 55 / 335
1095x415x215 / 43.1x16.3x8.5
20.0 / 44.1
Direct Ground

* TIA-222-G

Connector Position

1710-2690
+45

1710-2690
-45
1710-2690
+45

1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 46 of 139

Outdoor Directional Dual-band Antenna


ODV2-065R18J-G V1
XX Pol, 65
1710-2690/1710-2690MHz
17.9/17.9dBi, E-Tilt: 0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2690
1710-1880

1850-1990

17.0
68
7.3

17.2
69
6.8

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1920-2170
45
17.4
67
6.4
0-10 / 0-10
17(0)
16(5)
14(10)
14
25
18(typ.)
3
1.5:1
28
<-150
250
50

2300-2500

2490-2690

17.7
65
5.5

17.9
64
5.1

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1400x320x110 / 55.1x12.6x4.3
17.5 / 38.6
23.1 / 50.9
Fiberglass, Light Grey
00-ZJ10(16)
4 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

614 / 93 / 714
1700x435x215 / 66.9x17.1x8.5
27.0 / 59.5
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

DIN 7/16 F

1710-2690
+45

1710-2690
-45

DIN 7/16 F

DIN 7/16 F

1710-2690
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-2 / 0116

Page 47 of 139

XXX-Pol Antenna
Model

Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Length
(mm)

ODP-065R12M14JJ-G

XXX-Pol

698-960 / 1710-2690 / 1710-2690

12.0 / 15.2 / 15.2

65

FET 0 /
FET 0 /
FET 0

650

ODV-065R14M17JJ-G

XXX-Pol

698-960 / 1710-2690 / 1710-2690

14.2 / 17.0 / 17.0

65

VET 0-14 /
VET 0-10 /
VET 0-10

1270

ODV-065R15M18JJ-G

XXX-Pol

698-960 / 1710-2690 / 1710-2690

14.7 / 18.0 / 18.0

65

VET 0-14 /
VET 0-10 /
VET 0-10

1500

ODV-065R16M18JJ-G

XXX-Pol

698-960 / 1710-2690 / 1710-2690

15.6 / 17.6 / 17.6

65

VET 0-10 /
VET 0-10 /
VET 0-10

2000

ODV-065R17M18JJ-G

XXX-Pol

698-960 / 1710-2690 / 1710-2690

16.8 / 17.5 / 18.0

65

VET 0-10 /
VET 0-10 /
VET 0-10

2680

ODV-065R15EKK

XXX-Pol

790-960 / 1710-2170 / 1710-2170

15.0 / 14.9 / 15.0

65

VET 0-14 /
VET 0-14 /
VET 0-14

1510

ODV-065R15E18KK-G V2

XXX-Pol

790-960 / 1710-2170 / 1710-2170

15.0 / 17.2 / 17.2

65

VET 0-14 /
VET 0-10 /
VET 0-10

1510

ODV-065R17E18KK-G V1

XXX-Pol

790-960 / 1710-2170 / 1710-2170

16.5 / 17.2 / 17.2

65

VET 0-10 /
VET 0-10 /
VET 0-10

1970

ODV-065R18EKK-G

XXX-Pol

790-960 / 1710-2170 / 1710-2170

16.9 / 17.1 / 17.2

65

VET 0-10 /
VET 0-10 /
VET 0-10

2715

ODV-065R15EJJ

XXX-Pol

790-960 / 1710-2690 / 1710-2690

14.8 / 15.0 / 15.0

65

VET 0-14 /
VET 0-12 /
VET 0-12

1415

ODV-065R17EJJ-G

XXX-Pol

790-960 / 1710-2690 / 1710-2690

16.0 / 17.1 / 17.4

65

VET 0-10 /
VET 0-12 /
VET 0-12

2000

ODV-065R18EJJ-G

XXX-Pol

790-960 / 1710-2690 / 1710-2690

17.0 / 17.2 / 17.8

65

VET 0-10 /
VET 0-12 /
VET 0-12

2765

ODV3-065R18K-G V1

XXX-Pol

1710-2170 / 1710-2170 / 17102170

17.7 / 17.7 / 17.7

65

VET 0-10 /
VET 0-10 /
VET 0-10

1350

ODI3-065R15J-G

XXX-Pol

1710-2690 / 1710-2690 / 17102690

15.5 / 15.5 / 15.5

65

VET 0-12 /
VET 0-12 /
VET 0-12

800

ODV3-065R18J-G V1

XXX-Pol

1710-2690 / 1710-2690 / 17102690

18.0 / 18.0 / 18.0

65

VET 0-10 /
VET 0-10 /
VET 0-10

1460

Page 48 of 139

Outdoor Directional Tri-band Antenna


ODP-065R12M14JJ-G
XXX Pol, 65
698-960/1710-2690/1710-2690MHz
12.0/15.2/15.2dBi, FET: 0/0/0

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Fixed Electrical Downtilt ()
1st Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power Per Port (W)
Impedance ()

1710-2690

698-824

790-894

880-960

11.8
68
28.5

12.0
69
26.5
0
/

12.0
71
23.5

1710-1990
45
14.5
64
13.3

1710-2690

1920-2170

2490-2690

15.0
62
12.2
0/0
15

15.2
62
9.5

25(typ.)
17
1.5:1
25
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
650x380x138 / 25.6x15.0x5.4
10.4 / 22.9
13.2 / 29.1
Fiberglass, Light Grey
00-ZJ15A(32)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

258 / 51 / 306
905x490x270 / 35.6x19.3x10.6
17.0 / 37.5
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

DIN 7/16 F

1710-2690
+45

DIN 7/16 F

698-960
-45

DIN 7/16 F

698-960
+45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

1710-2690
-45

DIN 7/16 F

1710-2690
+45

DIN 7/16 F

Page 49 of 139

Outdoor Directional Tri-band Antenna


ODV-065R14M17JJ-G
XXX Pol, 65
698-960/1710-2690/1710-2690MHz
14.2/17.0/17.0dBi, E-Tilt: 0-14/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2690

698-824

790-894

880-960

13.6
68
17.4

14.0
66
16.2
0-14
17(0)
15(7)
14(14)

14.2
66
14.8

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
15.9
65
9.5

1710-2690

1920-2170

2490-2690

16.6
61
8.6
0-10 / 0-10
16(0)
15(5)
14(10)

17.0
63
6.6

25(typ.)
17
1.5:1
26

27
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (lb)
Lightning Protection

Specifications
1270x380x138 / 50.0x15.0x5.4
18.5 / 40.8
24.1 / 53.1
Fiberglass, Light Grey
00-ZJ10(16)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

563 / 105 / 673


1585x490x270 / 62.4x19.3x10.6
30.0 / 66.1
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

698-960
-45

698-960
+45

1710-2690
+45

DIN 7/16 F DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-0 / 0116

Page 50 of 139

Outdoor Directional Tri-band Antenna


ODV-065R15M18JJ-G
XXX Pol, 65
698-960/1710-2690/1710-2690MHz
14.7/18.0/18.0dBi, E-Tilt: 0-14/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-824

790-894

1710-2690
880-960

1710-2690

1710-1990

1920-2170

2490-2690

17.0
65
6.4

17.4
63
5.9
0-10 / 0-10
16(0)
15(5)
14(10)

18.0
64
4.6

45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

14.0
69
15.0

14.5
71
13.7
0-14
16(0)
15(7)
14(14)

1st Upper Sidelobe Suppression (dB)

14.7
67
12.4

14
25(typ.)
17
1.5:1

0-30Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

25

28
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1500x380x138 / 59.1x15.0x5.4
24.5 / 54.0
30.8 / 67.9
Fiberglass, Light Grey
00-ZJ11(12)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

694 / 126 / 824


1815x490x270 / 71.5x19.3x10.6
37.5 / 82.7
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

698-960
-45

698-960
+45

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Page 51 of 139

Outdoor Directional Tri-band Antenna


ODV-065R16M18JJ-G
XXX Pol, 65
698-960/1710-2690/1710-2690MHz
15.6/17.6/17.6dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-824

790-894

1710-2690
880-960

1710-2690

1710-1990

1920-2170

2490-2690

16.8
66
6.5

17.2
65
5.9
0-10 / 0-10
16(0)
15(5)
14(10)

17.6
64
4.6

45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

15.3
69
10.6

15.4
70
9.6
0-10
16(0)
15(7)
14(14)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

15.6
69
8.9

25(typ.)
17
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2000x380x138 / 78.7x15.0x5.4
26.0 / 57.3
31.6 / 69.7
Fiberglass, Light Grey
00-ZJ10(08)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

999 / 171 / 1189


2340x490x270 / 92.1x19.3x10.6
38.6 / 85.1
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

698-960
-45

698-960
+45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

DIN 7/16 F

DIN 7/16 F

Page 52 of 139

Outdoor Directional Tri-band Antenna


ODV-065R17M18JJ-G
XXX Pol, 65
698-960/1710-2690/1710-2690MHz
16.8/17.5/18.0dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690

698-824

790-894

880-960

16.0

16.5

16.8

69
8.7

68
7.9
0-10
17(0)
16(5)
14(10)

68
7.4

Polarization
Top
Bottom

Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination@0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
16.3
16.8
63
7.2

1920-2170

1710-2690
2300-2500

16.9
16.9
17.5
17.6
61
64
6.5
5.5
0-10 / 0-10
16(0)
15(5)
14(10)

2490-2690
17.5
18.0
65
5.0

25(typ.)
15
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2680x320x145 / 105.5x12.6x5.7
34.0 / 75.0
43.8 / 97.7
Fiberglass, Light Grey
00-ZJ10(08) (three mounting points)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1081 / 238 / 1350


2995x430x270 / 117.9x16.9x10.6
52.5 / 115.7
Direct Ground

*TIA-222-G

Connector Position

1710-2690
+45

1710-2690
+45

1710-2690
-45

1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

698-960
+45

698-960
-45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:0-0-2 / 0116

Page 53 of 139

Outdoor Directional Tri-band Antenna


ODV-065R15EKK
XXX Pol, 65
790-960/1710-2170/1710-2170MHz
15.0/14.9/15.0dBi, E-Tilt: 0-14/0-14/0-14

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

14.5

15.0

68

65

14.5

13.2

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

1710-1880
45
14.6
14.6
65
67
13.2
13.2

0-14
17(0)
16(7)
16(14)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2170

1850-1990

1920- 2170

14.8
14.9
64
64
12.6
12.6
0-14 / 0-14
16(0)
15(7)
15(14)

14.9
15.0
63
63
11.7
12.0

25(typ.)
17
2
1.5:1
28
30
<-150
500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1510x265x145 / 59.4x10.4x5.7
19.2 / 42.3
24.8 / 54.7
UV Resistant PVC, Light Grey
00-ZJ10(12)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150/200

Product Picture

432 / 160 / 432


1825x375x275 / 71.9x14.8x10.8
29.0 / 63.9
Direct Ground

*TIA-222-G

Connector Position
1710-2170
+45

1710-2170
-45
790-960
+45

790-960
-45

1710-2170
+45

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-1 / 0116

DIN 7/16 F

Page 54 of 139

Outdoor Directional Tri-band Antenna


ODV-065R15E18KK-G V2
XXX Pol, 65
790-960/1710-2170/1710-2170MHz
15.0/17.2/17.2dBi, E-Tilt: 0-14/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

790-896

880-960

14.5
64
14.6

15.0
61
13.4

1710-1880
45
16.8
64
7.2

0-14
18(0)
17(7)
16(14)

1st Upper Sidelobe Suppression (dB)

1710-2170

1850-1990

1920-2170

17.0
63
6.7
0-10 / 0-10
17(0)
16(5)
16(10)

17.2
62
6.3

15
25(typ.)
18
1.5:1
28
30
<-150

0-30Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1510x320x145 / 59.4x12.6x5.7
20.0 / 44.1
25.6 / 56.4
Fiberglass, Light Grey
00-ZJ10(13)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

531 / 131 / 674


1845x430x270 / 72.6x16.9x10.6
31.7 / 69.9
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

DIN 7/16 F

1710-2170
+45

DIN 7/16 F

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

1710-2170
-45

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-1 / 0116

1710-2170
+45

DIN 7/16 F

Page 55 of 139

Outdoor Directional Dual-band Antenna


ODV-065R17E18KK-G V1
XXX Pol, 65
790-960/1710-2170/1710-2170MHz
16.5/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

790-896

880-960

16.0
62
10.5

16.5
59
9.7

1710-1880
45
16.8
64
7.3

0-10
18(0)
17(5)
17(10)

1st Upper Sidelobe Suppression (dB)

1710-2170

1850-1990

1920-2170

17.0
61
6.7
0-10
17(0)
16(5)
16(10)

17.2
60
6.4

15
25
18
1.5:1
28
30
<-150

0-30Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1970x320x145 / 77.6x12.6x5.7
24.5 / 54
30.1 / 66.4
Fiberglass, Light Grey
00-ZJ10(12)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

738 / 171 / 942


2280x430x270 / 89.8x16.9x10.6
37.5 / 82.7
Direct Ground

* TIA-222-G

Connector Position

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+45

1710-2170
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 56 of 139

Outdoor Directional Tri-band Antenna


ODV-065R18EKK-G
XXX Pol, 65
790-960/1710-2170/1710-2170MHz
16.9/17.1/17.2dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

16.5

16.9

68

65

8.0

7.0

Polarization
Gain (dBi)
Horizontal Beamwidth()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

1710-1880
45
16.7
16.9
66
65
6.7
7.3

0-10
17(0)
16(5)
15(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2170

1850-1990

1920- 2170

17.0
17.1
63
64
6.3
6.9
0-10 / 0-10

17.1
17.2
62
63
6.0
6.6

Top: 18(0); 16(5); 15(10)


Bottom: 17(0); 15(5); 13(10)
25
18
2
1.5:1
28
30
<-150

500

300
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2715x265x145 / 106.9x10.4x5.7
33.0 / 72.8
42.0 / 92.6
Fiberglass, Light Grey
SJA-B-12R(08) (three mounting points)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

875 / 300 / 866


3055x375x275 / 120.3x14.8x10.8
48.0 / 105.8
Direct Ground

*TIA-222-G

Connector Position
1710-2170
+45

1710-2170
-45
790-960
+45

790-960
-45

1710-2170
+45

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-3 / 0116

DIN 7/16 F

Page 57 of 139

Outdoor Directional Tri-band Antenna


ODV-065R15EJJ
XXX Pol, 65
790-960/1710-2690/1710-2690MHz
14.8/15.0/15.0dBi, E-Tilt: 0-14/0-12/0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

Polarization
Gain (dBi)
Horizontal Beamwidth()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2690

790-896

880-960

1710-1880

14.5
68
14.5

14.8
66
13.2

13.7
69
16.3

1850-1990
45
14.0
67
15.2

0-14
17(0)
16(7)
15(14)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1920-2170

2300-2500

2490-2690

14.5
64
14.1
0-12/0-12
16(0)
15(6)
14(12)

15.0
57
12.1

15.0
55
11.0

25(typ.)
17
1.5:1
28

25
28
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1415x335x145 / 55.7x13.2x5.7
19.5 / 43.0
25.1 /55.3
UV Resistant PVC, Light Grey
00-ZJ10(16)
6x7/16 DIN-Female, Bottom
-40 to +60
95
150 / 200

Product Picture

514 / 122 / 651


1740x450x270 / 68.5x17.7x10.6
30.5 / 67.2
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-3 / 0116

Page 58 of 139

Outdoor Directional Tri-band Antenna


ODV-065R17EJJ-G
XXX Pol, 65
790-960/1710-2690/1710-2690MHz
16.0/17.1/17.4dBi, E-Tilt: 0-10/0-12/0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

15.4

16.0

68

66

9.6

9.0

2490-2690

15.6
16.0
67
68
9.3
9.5

17.1
17.4
57
57
6.5
6.5

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
18(0)
17(5)
16(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 ( 2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1710-1880

500

1850-1990
1920-2170
45
15.9
16.0
16.3
16.5
65
64
66
64
8.7
8.3
8.7
8.2
0-12 / 0-12
18(0)
17(6)
16(12)
25(typ.)
18
2
1.5:1
28
28
<-150
250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2000x320x145 / 78.7x12.6x5.7
28.7 / 63.3
35.0 / 77.2
Fiberglass, Light Grey
00-ZJ11(08)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150/200

Product Picture

751 / 173 / 960


2340x430x270 / 92.1x16.9x10.6
42.0 / 92.6
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-2 / 0116

Page 59 of 139

Outdoor Directional Tri-band Antenna


ODV-065R18EJJ-G
XXX Pol, 65
790-960/1710-2690/1710-2690MHz
17.0/17.2/17.8dBi, E-Tilt: 0-10/0-12/0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

16.7

17.0

68

65

6.7

6.0

1710-1990
45
16.3
16.6
68
68
7.0
7.0

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
18(0)
16(5)
15(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1920-2170

2490- 2690

16.9
17.2
65
65
6.5
6.5
0-12/0-12
17(0)
16(6)
15(12)

17.2
17.8
58
57
5.2
5.2

25(typ.)
18(typ.)
3
1.5:1
28
28
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2765x320x145 / 108.9x12.6x5.7
36.0 / 79.4
46.3 / 102.1
Fiberglass, Light Grey
00-ZJ11(08) (three mounting points)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1124 / 245 / 1401


3100x430x270 / 122.0x16.9x10.6
56.0 / 123.5
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-5 / 0116

Page 60 of 139

Outdoor Directional Tri-band Antenna


ODV3-065R18K-G V1
XXX Pol, 65
1710-2170/1710-2170/1710-2170MHz
17.7/17.7/17.7dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2170
1710-1880

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170
1850-1990
45
17.4
64
7.0
0-10 / 0-10 / 0-10
18(0)
17(5)
16(10)
15
25(typ.)
17
3
1.5:1
28
<-150
300
50

17.0
64
7.5

1st Upper Sidelobe Suppression (dB)


0-30Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation between Ports(dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2170
1920-2170
17.7
64
6.5

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1350x380x65 / 53.1x15.0x2.6
16.2 / 35.7
21.8 / 48.1
Fiberglass, Light Grey
00-ZJ10(16)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

760 / 53 / 827
1700x490x180 / 66.9x19.3x7.1
26.2 / 57.8
Direct Ground

*TIA-222-G

Connector Position

1710-2170
+45

1710-2170
-45
1710-2170
+45

1710-2170
-45

DIN 7/16 F

1710-2170
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:2-0-0 / 0116

Page 61 of 139

Outdoor Directional Tri-band Antenna


ODI3-065R15J-G
XXX Pol, 65
1710-2690/1710-2690/1710-2690MHz
15.5/15.5/15.5dBi, E-Tilt: 0-12/0-12/0-12
Integrated RCU

Electrical Specifications
Frequency Range (MHz)
1710-2690

Parameters / Specifications
Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880

1850-1990

14.8
67
12.4

14.8
71
11.5

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio @180(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation between Ports(dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690
1920-2170
45
14.9
70
10.9
0-12 / 0-12 / 0-12
17(0)
16(6)
15(12)
25(typ.)
17
1.5:1
28
<-150
250
50

1710-2690
2300-2500

2490-2690

15.3
64
9.4

15.5
67
8.7

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
800x500x140/ 31.5x19.7x5.5
18.0 / 39.7
23.6 / 52.0
Fiberglass, Light Grey
00-ZJ10(30)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

467 / 61 / 547
1100x635x305 / 43.3x25.0x12.0
29.0 / 63.9
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
-45

1710-2690
+45

1710-2690
+45

DIN 7/16 F DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

AISG IN AISG OUT

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:0-0-1 / 0116

Page 62 of 139

Outdoor Directional Tri-band Antenna


ODV3-065R18J-G V1
XXX Pol, 65
1710-2690/1710-2690/1710-2690MHz
18.0/18.0/18.0dBi, E-Tilt: 0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

1710-2690

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-1880

1850-1990

17.3
66
7.2

17.3
68
6.8

1710-2690
1920-2170
45
17.4
67
6.5
0-10 / 0-10 / 0-10

16(0)
16(5)
16(10)

1st Upper Sidelobe Suppression (dB)

1710-2690
2300-2500

2490-2690

17.8
64
5.5

18.0
68
5.1
17(0)
16(5)
15(10)

14
25(typ.)
17
1.5:1
28
<-150
250
50

0-30Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation between Ports(dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Front / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1460x500x140 / 57.5x19.7x5.5
30.5 / 67.2
36.8 / 81.1
Fiberglass, Light Grey
00-ZJ11(16)
6 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

962 / 117 / 1165


1815x635x305 / 71.5x25.0x12.0
43.5 / 95.9
Direct Ground

*TIA-222-G

Connector Position

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-0 / 0116

Page 63 of 139

XXXX-Pol Antenna
Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Length
(mm)

ODV-065R17M18JJJ-G

XXXX-Pol

698-960 / 1710-2690 /
1710-2690 / 1710-2690

16.6 / 16.8 / 17.6


/ 17.6

65

VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

2680

ODI-065R15NG18JJ-G

XXXX-Pol

698-862 / 880-960 /
1710-2690 / 1710-2690

14.3 / 14.4 / 17.9


/ 17.9

65

VET 2-16 /
VET 2-16 /
VET 2-12 /
VET 2-12

1500

XXXX-Pol

790-960 / 1710-2170 /
1710-2690 / 1710-2690

13.5 / 14.9 / 16.3


/ 16.3

65

VET 0-14 /
VET 0-10 /
VET 0-10 /
VET 0-10

800

ODI-065R15E18KJJ-G

XXXX-Pol

790-960 / 1710-2170 /
1710-2690 / 1710-2690

15.1 / 17.2 / 17.7


/ 17.7

65

VET 0-14 /
VET 0-10 /
VET 0-10 /
VET 0-10

1500

ODV-065R17EKJJ-G

XXXX-Pol

790-960 / 1710-2170 /
1710-2690 / 1710-2690

16.2 / 16.2 / 16.4


/ 16.8

65

VET 0-10 /
VET 0-10 /
VET 0-12 /
VET 0-12

2000

ODV-065R17E18JJJ-G

XXXX-Pol

790-960 / 1710-2690 /
1710-2690 / 1710-2690

17.1 / 17.1 / 17.2


/ 17.2

65

VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

2680

ODV2-065R17E18J-G

XXXX-Pol

790-960 / 790-960 /
1710-2690 / 1710-2690

16.6 / 16.6 / 16.8


/ 17.0

65

VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

2250

Model

ODI-065R12E15KJJ-G

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0514

Page 64 of 139

Outdoor Directional Quad-band Antenna


ODV-065R17M18JJJ-G
XXXX Pol, 65
698-960/1710-2690/1710-2690/1710-2690MHz
16.6/16.8/17.6/17.6dBi, E-Tilt: 0-10/0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690

698-824

790-894

880-960

16.0

16.3

16.6

70
8.0

67
7.5
0-10
17(0)
16(5)
14(10)

68
7.0

Polarization
Top
Bottom

Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-1990
45
16.0
16.5
65
7.0

1710-2690

1710-2690

1920-2170

2490-2690

16.4
17.1
62
6.5
0-10 / 0-10 / 0-10
16(0)
15(5)
14(10)

16.8
17.6
64
5.0

25(typ.)
15
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2680x380x138 / 105.5x15.0x5.4
36.5 / 80.5
46.8 / 103.2
Fiberglass, Light Grey
00-ZJ11(08) (three mounting points)
10 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200
1452 / 233 / 1744
2995x490x270 / 117.9x19.3x10.6
55.7 / 122.8
Direct Ground

* TIA-222-G

Connector Position

1710-2690
+45

1710-2690
+45

1710-2690
-45

1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

698-960
+45

698-960
-45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-1 / 0116

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

Page 65 of 139

Outdoor Directional Quad-band Antenna


ODI-065R15NG18JJ-G
XXXX Pol, 65
698-862/880-960/1710-2690/1710-2690MHz
14.3/14.4/17.9/17.9dBi, E-Tilt: 2-16/2-16/2-12/2-12
Integrated RCU

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-862
698-824

880-960
790-862

1710-2690

880-960

1710-2690

1710-1990

1920-2170

2490-2690

16.9
64
7.4

17.4
62
6.6
2-12 / 2-12
17(2)
16(7)
14(12)

17.9
64
4.9

45

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

14.0
68
14.9

14.3
65
13.9

14.4
65
12.6
2-16

2-16
16(2)
14(9)
14(16)

st

1 Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

25(typ.)
18(typ.)

20(typ.)
1.5:1
28
30
<-150

500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1500x380x138 / 59.1x15.0x5.4
30.5 / 67.2
36.1 / 79.5
Fiberglass, Light Grey
00-ZJ10(12)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

694 / 126 / 824


1965x490x270 / 77.4x19.3x10.6
43.5 / 95.9
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

880-960
-45

880-960
+45

698-862
-45

1710-2690
+45

DIN 7/16 F

DIN 7/16 F DIN 7/16 F

698-862
+45

1710-2690
+45

1710-2690
-45

AISG IN AISG OUT


DIN 7/16 F
DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-4 / 0116

DIN 7/16 F DIN 7/16 F DIN 7/16 F

Page 66 of 139

Outdoor Directional Quad-band Antenna


ODI-065R12E15KJJ-G
XXXX Pol, 65
790-960/1710-2170/1710-2690/1710-2690MHz
13.5/14.9/16.3/16.3dBi, E-Tilt: 0-14/0-10/0-10/0-10
Integrated RCU

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

12.9
61
24.5

13.5
60
23.0

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

0-14
15(0)
15(7)
14(14)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

500

1710-1990

1710-2690

1920-2170
45
14.7
14.9
62
59
12.3
11.1
0-10
13(0)
12(5)
11(10)
25(typ.)
17
1.5:1
25
30
<-150
300
50

1710-2690

1710-1990

1920-2170

2490-2690

14.7
71
12.0

15.2
69
11.0
0-10 / 0-10
15(0)
14(5)
13(10)

16.3
58
8.7

250

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
800x380x138 / 31.5x15.0x5.4
15.5 / 34.2
18.3 / 40.3
Fiberglass, Light Grey
00-ZJ15A(25)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

326 / 63 / 388
1090x490x260 / 42.9x19.3x10.2
21.6 / 47.6
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+45

1710-2690
+45

DIN 7/16 F DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F
AISG IN AISG OUT

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Page 67 of 139

Outdoor Directional Quad-band Antenna


ODI-065R15E18KJJ-G
XXXX Pol, 65
790-960/1710-2170/1710-2690/1710-2690MHz
15.1/17.2/17.7/17.7dBi, E-Tilt: 0-14/0-10/0-10/0-10
Integrated RCU

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
Electrical Downtilt ()

1710-2170

790-896

880-960

14.6
61
14.8

15.1
58
13.6
0-14
17(0)
16(7)
15(14)

st

1 Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

500

1710-1990

1920-2170
45
16.9
17.2
65
60
6.4
5.8
0-10
17(0)
16(5)
14(10)
25(typ.)
17
2
1.5:1
28
30
<-150
300
50

1710-2690

1710-2690

1710-1990

1920-2170

2490-2690

17.2
70
6.2

17.6
67
5.7
0-10 / 0-10
16(0)
15(5)
14(10)

17.7
59
4.6

250

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
1500x380x138 / 59.1x15.0x5.4
24.5 / 54.0
30.1 / 66.3
Fiberglass, Light Grey
00-ZJ10(16)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

694 / 126 / 824


1815x490x270 / 71.5x19.3x10.6
37.5 / 82.7
Direct Ground

* TIA-222-G

Connector Position

1710-2690
-45

1710-2170
-45

1710-2170
+45

790-960
-45

790-960
+45

1710-2690
+45

DIN 7/16 F DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F DIN 7/16 F

AISG IN AISG OUT

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Page 68 of 139

Outdoor Directional Quad-band Antenna


ODV-065R17EKJJ-G
XXXX Pol, 65
790-960/1710-2170/1710-2690/1710-2690MHz
16.2/16.2/16.4/16.8dBi, E-Tilt: 0-10/0-10/0-12/0-12

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2170

790-896

880-960

1710-1990

1920-2170
45

15.8

16.2

16.0

16.2

64

62

66

62

10.2

9.2

7.8

7.2

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
17(0)
16(5)
15(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
Beam Tracking Avg. (dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

0-10
17(0)
16(5)
15(10)
25(typ.)
18(typ.)
2
1.5:1
28
30
<-150
300
50

500

1710-2690

1710-2690

1710-1990

1920-2170

2490-2690

15.8
16.2
66
68
9.2
9.1

16.1
16.5
64
65
8.3
8.2
0-12 / 0-12
17(0)
16(6)
15(12)

16.4
16.8
61
60
6.5
6.4

250

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (lb)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2000x380x138 / 78.7x15.0x5.4
32.0 / 70.5
37.6 / 82.9
Fiberglass, Light Grey
00-ZJ10(08)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

999 / 171 / 1189


2340x490x270 / 92.1x19.3x10.6
45.0 / 99.2
Direct Ground

* TIA-222-G

Connector Position

1710-2690
+45

1710-2170
-45

1710-2690
-45

1710-2690
-45

DIN 7/16 F

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

790-960
-45

1710-2170
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-2 / 0116

790-960
+45

DIN 7/16 F

DIN 7/16 F

Page 69 of 139

Outdoor Directional Quad-band Antenna


ODV-065R17E18JJJ-G
XXXX Pol, 65
790-960/1710-2690/1710-2690/1710-2690MHz
17.1/17.1/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

16.6

17.1

61

58

7.9

7.2

1710-1990
45
16.3
16.7
69
69
7.2
7.2

Polarization
Gain (dBi)
Horizontal Beamwidth
()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
17(0)
16(5)
14(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1710-2690

1920-2170

2490-2690

16.6
16.9
66
65
6.5
6.5
0-10 / 0-10 / 0-10
16(0)
15(5)
14(10)

17.1
17.2
61
60
5.1
5.3

25(typ.)
17(typ.)
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2680x380x138 / 105.5x15.0x5.4
39.0 / 85.9
49.3 / 108.6
Fiberglass, Light Grey
00-ZJ11(08) (three mounting points)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1453 / 234 / 1745


2995x490x270 / 117.9x19.3x10.6
59.5 / 131.2
Direct Ground

* TIA-222-G

Connector Position

1710-2690
+45

1710-2690
+45

1710-2690
-45

1710-2690
-45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

790-960
+45

790-960
-45

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-3 / 0116

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

Page 70 of 139

Outdoor Directional Quad-band Antenna


ODV2-065R17E18J-G
XXXX Pol, 65
790-960/790-960/1710-2690/1710-2690MHz
16.6/16.6/16.8/17.0dBi, E-Tilt: 0-10/0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
790-960
Parameters / Specifications

1710-2690

1710-2690

790-960
790-896

880-960

16.1

16.6

68

66

9.0

8.3

1710-1990

2490-2690

15.9
16.2
60
60
7.9
7.5

16.8
17.0
64
65
6.0
5.3

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10 / 0-10
15(0)
13(5)
13(10)
11
11

st

1 Upper Sidelobe Suppression (dB)


0-30 Upper Sidelobe Suppression (dB)
0-180 Upper Sidelobe Suppression (dB)
Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IMD3 ( 2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

500

1920-2170
2300-2500
45
16.1
16.4
16.3
16.6
59
65
60
66
7.6
7.1
7.1
5.8
0-10 / 0-10
16(0)
15(5)
15(10)
12
7
25
18
1.5:1
27
28
<-150
250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2250x500x140 / 88.6x19.7x5.5
39.8 / 87.7
49.6 / 109.3
Fiberglass, Light Grey
00-ZJ10(12) (three mounting points)
8 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1658/ 185 / 2085


2630x635x305 / 103.5x25.0x12.0
59.8 / 131.8
Direct Ground

* TIA-222-G

Connector Position

790-960
-45

790-960
+45

1710-2690
-45

1710-2690
+45

1710-2690
-45

1710-2690
+45

790-960
-45

790-960
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 1215

Page 71 of 139

XXXXX-Pol Antenna
Model

Pol

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

ODV-065R17M18JJJJ-G

XXXXX-Pol

698-960 / 1710-2690 /
1710-2690 / 1710-2690 /
1710-2690

16.7 / 17.2 / 17.2


/ 17.9 / 17.9

65

XXXXX-Pol

698-806 / 824-960 /
1710-2690 / 1710-2690 /
1710-2690

15.0 / 15.7 / 16.0


/ 16.7 / 16.7

XXXXX-Pol

790-960 / 1710-2690 /
1710-2690 / 1710-2690 /
1710-2690

17.1 / 17.2 / 17.2


/ 17.2 / 17.2

ODI-065R16NB17JJJ-G

ODV-065R17E18JJJJ-G

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0514

Tilt
(deg)
VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

Length
(mm)

2680

65

VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

2400

65

VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10 /
VET 0-10

2680

Page 72 of 139

Outdoor Directional Penta-band Antenna


ODV-065R17M18JJJJ-G
XXXXX Pol, 65
698-960/1710-2690/1710-2690/1710-2690/1710-2690MHz
16.7/17.2/17.2/17.9/17.9dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960

1710-2690 1710-2690 1710-2690 1710-2690

698-824

790-896

880-960

16.0

16.6

16.7

68

66

68

8.7

7.7

7.1

1710-1990
45
16.2
16.8
65
63
7.4
7.3

Polarization
Gain (dBi)
Horizontal Beamwidth
()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
17(0)
16(5)
14(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1920-2170

2300-2500

16.6
16.6
17.3
17.2
64
62
64
62
6.7
5.5
6.6
5.5
0-10 / 0-10 / 0-10 / 0-10
16(0)
15(5)
14(10)

2490-2690
17.2
17.9
64
63
5.1
5.1

25(typ.)
17(typ.)
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2680x380x138 / 105.5x15.0x5.4
43.0 / 94.8
52.8 / 116.4
Fiberglass, Light Grey
00-ZJ10(08) (three mounting points)
10 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1453 / 234 / 1745


2995x490x270 / 117.9x19.3x10.6
63.5 / 140.0
Direct Ground

* TIA-222-G

Connector Position
698-960
+45

698-960
-45
1710-2690
+45

1710-2690
+45
1710-2690
-45

DIN 7/16
FDIN

1710-2690
-45

1710-2690
-45

DIN 7/16 F DIN 7/16 F

DIN 7/16 F DIN 7/16 F DIN 7/16 F

1710-2690
-45
1710-2690
+45

DIN 7/16 F

DIN 7/16 F DIN 7/16 F

1710-2690
+45

DIN 7/16 F

7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-2 / 0216

Page 73 of 139

Outdoor Directional Penta-band Antenna


ODI-065R16NB17JJJ-G
XXXXX Pol, 65
698-806/824-960/1710-2690/1710-2690/1710-2690MHz
15.0/15.7/16.0/16.7/16.7dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10
Integrated RCU

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

824-960

698-806

1710-2690

698-806

824-894

880-960

15.0

15.5

15.7

67

65

66

10.3

9.1

8.6

1710-1990
45
15.4
15.9
66
8.7
7.9

Polarization
Top
Bottom
Horizontal Beamwidth ()
Top
Vertical Beamwidth
()
Bottom
Electrical Downtilt ()
Gain (dBi)

0-10

0-10
14(0)
13(5)
13(10)

st

1 Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1710-2690

1920-2170

2490-2690

15.9
16.7
65
7.8
7.1
0-10 / 0-10 / 0-10
16(0)
15(5)
14(10)

16.0
16.7
65
6.1
5.5

25(typ.)
18(typ.)
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2400x380x138 / 94.5x15.0x5.4
42.0 / 92.6
51.8 / 114.2
Fiberglass, Light Grey
00-ZJ10(12)(three mounting points)
10 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1259 / 208 / 1507


2715x490x270 / 106.9x19.3x10.6
62.0 / 136.7
Direct Ground

* TIA-222-G

Connector Position

1710-2690
+45
1710-2690
-45

DIN 7/16 F

824-960
+45

698-806
-45

824-960
-45

DIN 7/16 F DIN 7/16 F

1710-2690
-45

698-806
+45

DIN 7/16 F

DIN 7/16 F

DIN 7/16 F

1710-2690
+45

DIN 7/16 F

DIN 7/16 F

1710-2690
+45
1710-2690
-45

DIN 7/16 F

DIN 7/16 F

AISG IN AISG OUT

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-3 / 0116

Page 74 of 139

Outdoor Directional Penta-band Antenna


ODV-065R17E18JJJJ-G
XXXXX Pol, 65
790-960/1710-2690/1710-2690/1710-2690/1710-2690MHz
17.1/17.2/17.2/17.2/17.2dBi, E-Tilt: 0-10/0-10/0-10/0-10/0-10

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

790-960

1710-2690

790-896

880-960

16.6

17.1

61

58

7.9

7.2

1710-1990
45
16.3
16.7
69
69
7.2
7.2

Polarization
Gain (dBi)
Horizontal Beamwidth
()
Vertical Beamwidth ()

Top
Bottom
Top
Bottom
Top
Bottom

Electrical Downtilt ()

0-10
17(0)
16(5)
14(10)

1st Upper Sidelobe Suppression (dB)


Front-To-Back Ratio 18030(dB)
Cross-polar Discrimination @0(dB)
VSWR
Isolation Intra-system (dB)
Isolation Inter-system (dB)
IM3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

1710-2690

1710-2690

1710-2690

1920-2170

2490-2690

16.6
16.9
66
65
6.5
6.5
0-10 / 0-10 / 0-10 / 0-10
16(0)
15(5)
14(10)

17.2
17.2
61
60
5.1
5.3

25(typ.)
17(typ.)
1.5:1
28
30
<-150
500

250
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Weight, with Mounting Kit (kg) / (Ib)
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature (C)
Operational Humidity (%)
Operational/Max Wind Speed (km/h)
Wind Load* @ 150km/h
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
2680x380x138 / 105.5x15.0x5.4
43.0 / 94.8
54.3 / 117.5
Fiberglass, Light Grey
00-ZJ11(08) (three mounting points)
10 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 / 200

Product Picture

1453 / 234 / 1745


2995x490x270 / 117.9x19.3x10.6
66.0 / 145.5
Direct Ground

* TIA-222-G

Connector Position
790-960
+45

790-960
-45
1710-2690
+45

1710-2690
+45
1710-2690
-45

DIN 7/16
FDIN

1710-2690
-45

1710-2690
-45

DIN 7/16 F DIN 7/16 F

DIN 7/16 F DIN 7/16 F DIN 7/16 F

1710-2690
-45
1710-2690
+45

DIN 7/16 F

DIN 7/16 F DIN 7/16 F

1710-2690
+45

DIN 7/16 F

7/16 F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-3 / 0116

Page 75 of 139

Indoor Antenna

Page 76 of 139

Indoor Antenna
Indoor Antenna ............................................................................................................................................................................................... 78
IWH-090V08N0-D ................................................................................................................................................................................ 79
IXD-360V03NN(05) .............................................................................................................................................................................. 80
IXD-360V03NU(05) .............................................................................................................................................................................. 81
IXD-360VH03NN .................................................................................................................................................................................. 82
IWH-090VR08NT ................................................................................................................................................................................. 83

Page 77 of 139

Indoor Antenna
Model

POL

Frequency
(MHz)

Gain
(dBi)

HPBW
(deg)

Tilt
(deg)

Dimension
(mm)

IWH-090V08N0-D

V-Pol

698-960/1710-2700

5.5/7.5

90

210x180x44

IXD-360V03NN(05)

V-Pol

670-960/1710-2700

2.0/4.0

360

208x112

IXD-360V03NU(05)

V-Pol

600-960/1710-4000

2.0/4.0

360

208x112

IXD-360VH03NN

VH Pol

698-960 / 1710-2700

4.0 / 4.8

360

210 x 41

IWH-090VR08NT

VX-Pol

790-960/1710-2700MHz

7.0 / 8.2

90

278x176x62

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0814

Page 78 of 139

Indoor Directional Wall Mounted Antenna


IWH-090V08N0-D
V Pol, 90
698-960/1710-2700MHz
5.5/7.5dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-960
698-800

Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
VSWR
IMD3 (2x33 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

3.5
120
81
1.8:1

1710-2700
800-960
Vertical
5.5
93
77

1710-2700
7.5
56
35
1.5:1

-140
50
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Radome Material and Color
Connector Type and Location
Operational Temperature (C)
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
210x180x44 / 8.3x7.1x1.7
0.6 / 1.3
ABS, White
1 x N-Female, Bottom
-30 to +45
Wall Mounted
255x190x60 / 10.0x7.5x2.4
0.8 / 1.8
Indoor

Product Picture

Connector Position & Installation Guide

698-960
1710-2700

N-FDIN 7/16 F

Installation Steps
1)
2)
3)
4)

Drill four holes in wall per pattern of holes in plate (item 2) shown above
Attach flat side of plate (item 2) to wall using wall anchors (item 4) and screws (item 3)
Mount antenna (item 1), to plate (item 2)
Connect RF cable

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0415

Page 79 of 139

Indoor Omni-directional Ceiling Mounted Antenna


IXD-360V03NN(05)
V Pol, 360
670-960/1710-2700MHz
2.0/4.0dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

670-960
670-696

Polarization
Gain (dBi)
Horizontal Beamwidth ()
VSWR
IMD3 (2x33 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

696-806

1710-2700
806-960
Vertical

1710-2500

2.0

2500-2700
4.0

360
2.5:1

2.0:1

1.5:1
<-140
100
50

Mechanical Specifications
Parameters
Dimensions, Diameter x Length (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Radome Material and Color
Connector Type and Location
Operational Temperature (C)
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
208x112 / 8.2x4.4
0.4 / 0.9
ABS, White
1 x N-Female, Bottom
-30 to +45
Ceiling Mounted
175x175x180 / 6.9x6.9x7.1
0.5 / 1.1
Indoor

Product Picture

Connector Position & Installation Drawing

670-960
1710-2700

N- F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-4 / 1214

Page 80 of 139

Indoor Omni-directional Ceiling Mounted Antenna


IXD-360V03NU(05)
V Pol, 360
600-960/1710-4000MHz
2.0/4.0dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

600-960
600-698

Polarization
Gain (dBi)
Horizontal Beamwidth ()
VSWR
IMD3 (2x43 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

698-790

1710-4000
790-960

1710-2700

2700-4000

Vertical
2.0

4.0
360

3.5:1

2.0:1

1.5:1

1.5:1

2.0:1

<-153
100
50

Mechanical Specifications
Parameters
Dimensions, Diameter x Length (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Radome Material and Color
Connector Type and Location
Operational Temperature (C)
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
208x112 / 8.2x4.4
0.45 / 1.0
ABS, White
1 x N-Female, Bottom
-30 to +45
Ceiling Mounted
175x175x180 / 6.9x6.9x7.1
0.55 / 1.2
Indoor

Product Picture

Connector Position

600-960
1710-4000

N- F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:1-0-2 / 0615

Page 81 of 139

Indoor Omni-directional Ceiling Mounted Antenna


IXD-360VH03NN
VH Pol, 360
698-960/1710-2700MHz
4.0/4.8dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications
Polarization
Gain (dBi)
Horizontal Beamwidth ()
VSWR
Isolation between Ports (dB)
IMD3 (2x33 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

698-960

1710-2700

698-790

790-960

3.5

4.0

1710-2170
Dual linear V&H
4.5
360
2.0:1

18

2170-2700
4.8

20
-140
50
50

Mechanical Specifications
Parameters
Dimensions, Diameter x Length (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Radome Material and Color
Connector Type and Location
Operational Temperature (C)
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
210x41 / 8.3x1.6
0.4 / 0.9
ABS, White
2 x N-Female, Bottom
-30 to +45
Ceiling Mounted
205x205x210 / 8.1x8.1x8.3
0.6 / 1.3
Indoor

Product Picture

Connector Position & Installation Guide

698-960
1710-2700

698-960
1710-2700

N- F

N- F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0/ 0414

Page 82 of 139

Indoor Directional Wall Mounted Antenna


IWH-090VR08NT
VX Pol, 90
790-960/1710-2700MHz
7.0/8.2dBi

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications
Polarization
Gain (dBi)
Horizontal Beamwidth ()
Vertical Beamwidth ()
VSWR
Isolation between Ports (dB)
IMD3 (2x33 dBm Carrier) (dBc)
Maximum Power per Port (W)
Impedance ()

790-960
790-960
Vertical
7.0
88
55

1710-2700
1710-2170

2300-2700
45

8.0
75
44
1.5:1

8.2
65
52
25

/
-140
50
50

Mechanical Specifications
Parameters
Dimensions, HxWxD (mm) / (in)
Weight, w/o Mounting Kit (kg) / (lb)
Radome Material and Color
Connector Type and Location
Operational Temperature (C)
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
278x176x62 / 10.9x6.9x2.4
0.7 / 1.5
PVC, Light Grey
2 x N-Female, Bottom
-30 to +45
Wall Mounted
338x221x80 / 13.3x8.7x3.1
0.8 / 1.8
Indoor

Product Picture

Connector Position & Installation Guide

790-960
1710-2700

1710-2700

N-F

N-F

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-0 / 1214

Page 83 of 139

RET System

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-2 / 0414

Page 84 of 139

RET System & Accessories


00-KX02A(xx)(xx=cable length in meter) .............................................................................................................................................. 86
CCU-003AG ......................................................................................................................................................................................... 87
RCU-003(IV) ........................................................................................................................................................................................ 88
BT-R4S2, BT-R5S2.............................................................................................................................................................................. 89

AISG Control Cable


00-KX02A(xx)(xx=cable length in meter)

5-core cable use for connection between AISG antenna line devices
Compliance with AISG1.1 and AISG2.0
8-pin Circular connector type
Weather resistance
Supply in various length

Electrical Specifications
Parameters

Specifications

Operating Voltage (V)

250

Operating Current @40C (A)

Pulsating Voltage (V)

1200

Insulation Resistance ()

>3x109

Contact Resistance (m)

<5

Mechanical Specifications
Parameters

Specifications

Cable Specification

2Cx0.32 + 3Cx0.75

Connector Type

2 x 8 pin circular connector, 1 Male + 1 Female

Operating Temperature

-40 to +85

Operating Humidity

95

Environmental Class

IP67

Ordering Information

AISG Cable Connector

Model Number

Length

00-KX02A(0.5) (m) / (in)

0.5 / 19.7

00-KX02A(1) (m) / (in)

1 / 39.4

00-KX02A(2) (m) / (in)

2 / 78.7

00-KX02A(3) (m) / (in)

3 / 118.1

00-KX02A(7) (m) / (in)

7 / 275.6

00-KX02A(5) (m) / (in)

5 / 196.9

00-KX02A(10) (m) / (in)

10 / 393.7

00-KX02A(15) (m) / (in)

15 / 590.6

00-KX02A(20) (m) / (in)

20 / 787.4

00-KX02A(25) (m) / (in)

15 / 984.3

00-KX02A(30) (m) / (in)

30 / 1,181.1

00-KX02A(40 ) (m) / (in)

40 / 1,574.8

00-KX02A(50 ) (m) / (in)

50 / 1,968.5

00-KX02A(60 ) (m) / (in)

60 / 2,362.2

00-KX02A(70 ) (m) / (in)

70 / 2,755.9

00-KX02A(80 ) (m) / (in)

80 / 3,149.6

00-KX02A(90) (m) / (in)

90 / 3,543.3

00-KX02A(100) (m) / (in)

100 / 3937

00-KX02A(110) (m) / (in)

110 / 4331

00-KX02A(120) (m) / (in)

120 / 4724

00-KX02A(130) (m) / (in)

130 / 5118

00-KX02A(140) (m) / (in)

140 / 5512

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0715

Male Connector

Female Connector

PIN assignment according AISG:


1 +13 V DC (+12 V DC nominal)
2 not connected
3 RS485 B
4 not connected
5 RS485 A
6 +29 V DC (+24 V DC nominal)
7 DC Return
8 not connected

Page 86 of 139

RET Central Control Unit Ver. 2.0


CCU-003AG

AISG v1.0 & v2.0 Compliance.


Web-based application with built-in watchdog timer and supports USB 2.0
Self-diagnosable
With overload, lightning surge, and short circuit protection
Available in single or three AISG port model
Compliant with CE, FCC and RoHS Standards
Wall/Rack mountable

Electrical Specifications
Parameters
AISG Connectors
Power Supply to AISG Devices

Specifications
3 x 8 pin connector, Female, conform to AISG Layer 1
28VDC / 1.7A, or 13VDC / 3.3A (Selectable using software)

Power Supply Input

-48 DC / 1.5A

Total Output Power

50W

LED Indicators

Alarm, Run, Power

Interface to RCU/TMA

RS-485 / Power Supply

Protocol to RCU/TMA

HDLC hex-code command set, conform to AISG Layer 2

Max. Number of RET*

Up to 24 RCUs (depending on cable configuration)

Max. Number of TMA*

Up to 6 TMAs (depending on cable configuration)

Interface for Remote Control


Communication Ports
Protocols to BTS
Protection

Ethernet 10/100M adaptable


RS-232, USB 2.0
TCP/IP, HTTP/HTML, SNMP, FTP, Telnet
Built-in LPD, Over Load, Surge, Short Circuit

Mechanical Specifications
Parameters
Mounting
Dimensions, HxWxD (mm) / (in)
Weight Kit (kg) / (Ib)
RS232 Connector

Specifications
1U, 19 inch rack-mount or Wall Mounted
44x220x185 / 1.7x8.6x7.3
1.5 / 3.3
9-PIN Mini-DIN PS/2

Housing Material and Color

Aluminium, Light Grey

Operating Temperature (C)

0 to +55

Operating Humidity (%)


Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)

<95
83x280x253 / 3.3x11.0x10.0
1.9 / 4.2

CCU System Structure

Note: Comba COMETS is a software tool that provides comprehensive features for OMC. For more information, please kindly refer to the COMETS
datasheet

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-1-2 / 0815

Page 87 of 139

Remote Control Unit


RCU-003(IV)
3GPP / AISG 2.0 Compliance
Compact size and IP65 protection class

Electrical Specifications
Parameters

Specifications

Connectors to CCU

8 pin connector, Male, conform to AISG 2.0

Connectors to RCU

8 pin connector, Female, conform to AISG 2.0

Power Supply (V)

+15 to +30 DC

Power Consumption (W)

<1(stand by); <10(operating)

Protocol to CCU/TMA

3GPP / AISG 2.0

Adjustment Time (s) (full range)

<60(typically, depending on antenna type)

Adjustment Cycles

>50,000

Mechanical Specifications
Parameters

Specifications

Dimensions, HxWxD (mm) / (in)

124.5x44x41 / 4.9x1.7x1.6

Weight (kg) / (Ib)

0.25 / 0.6

Housing Material and Color

Aluminum, Light Grey

Operating Temperature (oC)

-40 to +60

Environment Class

IP65

Shipping Dimensions, HxWxD (mm) / (in)

145x52x48 / 5.7x2.0x1.9

Shipping Weight (kg) / (Ib)

0.3 / 0.7

Product View

Top View of RCU

Bottom View of RCU

PIN assignment according AISG:


1 not connected
2 not connected
3 RS485 B
4 not connected
5 RS485 A
6 +15 V ~ +30 V DC (+24 V DC nominal)
7 DC Return
8 not connected

Connector

Male Connector

Overview of RCU

Female Connector

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-3 / 0815

Page 88 of 139

Wide-band Smart Bias Tee


BT-R4S2, BT-R5S2

Wide-band design covers 698-2700MHz range


Provides DC voltage and remote control signals via RF feeder cable to TMA
or to ALDs
Complies with AISG 2.0 standard
Low insertion loss and VSWR
Provides lightning protection for BTS/Node B
BT-R4S2 is commonly installed close to BTS/Node B and BT-R5S2 is
installed on the tower close to VET antenna when no AISG TMA is in use
BT-R5S2 photo shown for reference

Electrical Specifications
Parameters

Specifications
BT-R4S2

BT-R5S2
698-2700

Frequency Range (MHz)


Insertion Losses (dB)
VSWR
Modem Carrier Frequency (MHz)
Intermodulation Products (dBc)
Power Handling (W)
Current Capacitance (A)
Operational Voltage (V)
Model
Impedance ()

0.2
1.2
2.176
-153@2x43dBm
120
2.3
10-30
+24V(AISG port in, ANT port out)
+24V(BTS/Node B port in, AISG port out)
50

Mechanical Specifications
Parameters
Dimensions,LxWxH (including connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and
mounting bracket) (kg) / (Ib)
BTS/Node B Port
Connector Type
ANT Port
DC/AISG Port
Operational Temperature (C)
Operational Humidity (%)
Environmental Class
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Lightning Protection

Specifications
BT-R4S2

BT-R5S2
119x73x46 / 4.7x2.9x1.8
0.5 / 1.0

7/16 DIN-Female
7/16 DIN-Male
8-PIN Male Connector

7/16 DIN-Male
7/16 DIN-Female
8-PIN Female Connector

-40 to +65
95
IP66
170x80x100 / 6.7x3.1x3.9
0.6 / 1.3
Comply with IEC 61000-4-5; 8kA, 8/20s

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 /0614

Page 89 of 139

RF Product

Page 90 of 139

RF Product
Combiner......................................................................................................................................................................................................... 92
CM-AC2D-ODxA .................................................................................................................................................................................. 94
CM-AC2-ODx,CM-AC2D-ODx .............................................................................................................................................................. 95
CM-ACG3-ODx, CM-ACG3D-ODx ....................................................................................................................................................... 96
CM-ACKP4-OD1A................................................................................................................................................................................ 97
CM-ADWTY5-OD6 ............................................................................................................................................................................... 98
CM-AE2-ODx, CM-AE2D-ODx ............................................................................................................................................................. 99
CM-AG2-ODx, CM-AG2D-ODx .......................................................................................................................................................... 100
CM-DW2-ODxG, CM-DW2D-ODxG ................................................................................................................................................... 101
CM-DWY3-ODxA, CM-DWY3D-ODxA ............................................................................................................................................... 102
CM-FDW3-ODx, CM-FDW3D-ODx..................................................................................................................................................... 103
CM-FDWY4-ODx, CM-FDWY4D-ODx ................................................................................................................................................ 104
CM-FK2-ODx, CM-FK2D-ODx ........................................................................................................................................................... 105
CM-FKY3-ODx, CM-FKY3D-ODx ....................................................................................................................................................... 106
CM-KTY3-OD4 ................................................................................................................................................................................... 107
CM-KY2-ODxB, CM-KY2D-ODxB ...................................................................................................................................................... 108
CM-MY2-ODx, CM-MY2D-ODx .......................................................................................................................................................... 109
CM-PK2-ODx,CM-PK2D-ODx ............................................................................................................................................................ 110
CM-PPK3-ODx, CM-PPK3D-ODx ...................................................................................................................................................... 111
CM-W2D-ODx .................................................................................................................................................................................... 112

Hybrid Combiner........................................................................................................................................................................................... 113


COM-BD21ODN4............................................................................................................................................................................... 114
COM-BD21ODN8............................................................................................................................................................................... 115
COM-BD21ONN5............................................................................................................................................................................... 116

Directional Coupler....................................................................................................................................................................................... 117


DC-Rxx-OD500C(H)........................................................................................................................................................................... 118
DC-Rxx-ON300C(H)........................................................................................................................................................................... 120
Hybrid Coupler.............................................................................................................................................................................................. 122
HC-R4-OD200L, HC-R4-ON200L ....................................................................................................................................................... 123
HC-R-OD500L(XH) ............................................................................................................................................................................ 124
HC-R-ON300L(H)............................................................................................................................................................................... 125
Power Splitter ............................................................................................................................................................................................... 126
PS-R2-OD500C(XH), PS-R3-OD500C(XH), PS-R4-OD500C(XH) ..................................................................................................... 127
PS-R2-ON500C(H), PS-R3-ON500C(H), PS-R4-ON500C(H)............................................................................................................. 128
Filter .............................................................................................................................................................................................................. 129
FP-G70-OD01 .................................................................................................................................................................................... 130
Multiple Operator Combiner......................................................................................................................................................................... 131
POI-BD92ONY5 ................................................................................................................................................................................. 132
POI-CDG4IDN1.................................................................................................................................................................................. 134

Page 91 of 139

Combiner
Model

Frequency
(MHz)

Connector
Type

Mounting

Dimension
Single Unit
(mm)

Dimension
Dual Unit
(mm)

CM-AC2D-ODxA

Band 1: 698-803
Band 2: 824-894

DIN-Female

Pole or Wall
Mount

246x178x112

CM-AC2-ODx,
CM-AC2D-ODx

Band 1: 698-798
Band 2: 817-894

DIN-Female

Pole or Wall
Mount

246x178x56

246x178x114

CM-ACG3-ODx,
CM-ACG3D-OD6x

Band 1: 703-803
Band 2: 825-880
Band 3: 898.4-960

DIN-Female

Pole or Wall
Mount

249x200x58

249x200x118

CM-ACKP4-OD1A

Band 1: 698-787
Band 2: 806-894
Band 3: 1710-1755/2110-2155
Band 4: 1850-1995

DIN-Female

Pole or Wall
Mount

216x183x56

CM-ADWTY5-OD6

Band 1: 678-960
Band 2: 1710-1880
Band 3: 1920-2170
Band 4: 2300-2390
Band 5: 2500-2690

DIN-Female

Pole or Wall
Mount

260x240x50

CM-AE2-ODx,
CM-AE2D-ODx

Band 1:790-862
Band 2:880-960

DIN-Female

Pole or Wall
Mount

188x176x68

188x176x138

CM-AG2-ODx,
CM-AG2D-ODx

Band 1:698-806
Band 2:880-960

DIN-Female

Pole or Wall
Mount

201.5x151x58

201.5x151x118

CM-DW2-ODxG,
CM-DW2D-ODxG

Band 1: 1710-1880
Band 2: 1920-2170

DIN-Female

Pole or Wall
Mount

278x124x49

278x124x124

CM-DWY3-ODAx,
CM-DWY3D-ODAx

Band 1: 1710-1880
Band 2: 1920-2170
Band 3: 2500-2690

DIN-Female

Pole or Wall
Mount

240x210x50

240x210x103

CM-FDW3-ODx,
CM-FDW3D-ODx

Band 1: 380-960
Band 2: 1710-1880
Band 3: 1920-2170

DIN-Female

Pole or Wall
Mount

220x180x50.5

220x180x103

Page 92 of 139

Model

Frequency
(MHz)

Connector
Type

Mounting

Dimension
Single Unit
(mm)

Dimension
Dual Unit
(mm)

CM-FDWY4-ODx,
CM-FDWY4D-ODx

Band 1: 380-960
Band 2: 1710-1880
Band 3: 1920-2170
Band 4: 2500-2690

DIN-Female

Pole or Wall
Mount

240x210x50

240x210x103

CM-FK2-ODx,
CM-FK2D-ODx

Band 1: 380-960
Band 2: 1710-2700

DIN-Female

Pole or Wall
Mount

180x110x50

180x110x103

CM-FKY3-ODx,
CM-FKY3D-ODx

Band 1: 380-960
Band 2: 1710-2170
Band 3: 2300-2690

DIN-Female

Pole or Wall
Mount

187x158x50

187x158x102

CM-KTY3-OD4

Band 1: 1710-2170
Band 2: 2300-2390
Band 3: 2500-2690

DIN-Female

Pole or Wall
Mount

146x138x44.5

CM-KY2-ODxB,
CM-KY2D-ODxB

Band 1: 1710-2170
Band 2: 2300-2700

DIN-Female

Pole or Wall
Mount

142x121x69

142x121x140

CM-MY2-ODx,
CM-MY2D-ODx

Band 1: 806-960/1710-2170
Band 2: 2300-2700MHz

DIN-Female

Pole or Wall
Mount

156x142x58

156x142x118

CM-PK2-ODx,
CM-PK2D-ODx

Band 1: 1850-1910/1930-1990
Band 2: 1710-1755/2110-2155

DIN-Female

Pole or Wall
Mount

167x143x45

167x143x97

CM-PPK3-ODx,
CM-PPK3D-ODx

Band 1: 1850-1875/1930-1955
Band 2: 1885-1910/1965-1990
Band 3: 1710-1755/2110-2155

DIN-Female

Pole or Wall
Mount

213x196x92

213x196x194

CM-W2D-ODx

Band 1: 2110-2130&1920-1940
Band 2: 2160-2170&1970-1980

DIN-Female

Pole or Wall
Mount

230x150x90

Page 93 of 139

Outdoor Dual-Band Combiner


CM-AC2D-ODxA
Band 1:698-803MHz Band 2:824-894MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Double units

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

698-803

824-894

Insertion Loss (dB)

0.4

Isolation between Ports (dB)

60

Return Loss (dB)

20

Maximum Input Power per Port (W)

250
-153@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
RF Connectors

Specifications
246x178x112 / 9.7x7.0x4.4
6.6 / 14.6
7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)

465x365x250 / 18.3x14.4x9.8

Shipping Weight (kg) / (lb)

8.1 / 17.9

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

DC Bypass Optional
No DC Bypass
DC Bypass @698-803
DC Bypass @824-894
Full DC Pass

Port 3

Port 1
698-803

DC/AISG Bypass

Double units Model


Number
CM-AC2D-OD1A
CM-AC2D-OD2A
CM-AC2D-OD3A
CM-AC2D-OD4A

Block Diagram

DC/AISG Bypass

Ordering Information

Port 2
824-894

Example: View of Single Unit CM-AC2-OD4A

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Page 94 of 139

Outdoor Dual-Band Combiner


CM-AC2-ODx,CM-AC2D-ODx (x=1, 2, 3 or 4, Preconfigured DC-pass)
Band 1:698-798MHz Band 2:817-894MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units
Single unit for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

698-798

817-894

Insertion Loss (dB)

0.4

Isolation between Ports (dB)

60
20

Return Loss (dB)


Coupling Value at Com Port (dB)

43.52

Maximum Input Power per Port (W)

250
-153@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

246x178x56 / 9.7x7.0x2.2

Double Units

246x178x114 / 9.7x7.0x4.5

Single Unit

3.2 / 7.1

Double Units

6.6 / 14.6

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (lb)

Single Unit

400x300x220 / 15.7x11.8x8.56

Double Units

465x365x250 / 18.3x14.4x9.8

Single Unit

4.9 / 10.8

Double Units

8.1 / 17.9

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Double units Model


Number
CM-AC2D-OD1
CM-AC2D-OD2
CM-AC2D-OD3
CM-AC2D-OD4

DC Bypass Optional
No DC Bypass
DC Bypass @698-798
DC Bypass @817-894
Full DC Pass

Port 3

Port 1
698-798

Couple port

DC/AISG Bypass

Single Unit Model


Number
CM-AC2-OD1
CM-AC2-OD2
CM-AC2-OD3
CM-AC2-OD4

Block Diagram

DC/AISG Bypass

Ordering Information

Port 2
817-894

Example: View of Single Unit CM-AC2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Page 95 of 139

Outdoor Tri-band Combiner


CM-ACG3-ODx, CM-ACG3D-ODx
Band 1:703-803MHz Band 2:825-880MHz
Band 3:898.4-960MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications
Insertion Loss (dB)

703-803

825-880

898.4-960

0.4

0.5

0.6

50

Isolation between Ports (dB)


Out of Band Rejection (dB)

30@880-890MHz

/
20

Return Loss (dB)


Maximum Input Power per Port (W)

200
-153@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

249x200x58 / 9.8x7.9x2.3

Double Units

249x200x118 / 9.8x7.9x4.6

Single Unit

4.0 / 8.8

Double Units

7.8 / 17.2

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65
95

Operational Humidity (%)


Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

495x340x205 / 19.5x13.4x8.1

Double Units

520x355x235 / 20.5x14.0x9.3

Single Unit

5.7 / 12.6

Double Units

Lightning Protection

Ordering Information

Block Diagram
Port 4

No DC Bypass
DC Bypass @703-803
DC Bypass @825-880
DC Bypass @898.4-960
Full DC Pass

DC/AISG Bypass

DC Bypass Optional

DC/AISG Bypass

Double units Model


Number
CM-ACG3D-OD1
CM-ACG3D-OD2
CM-ACG3D-OD3
CM-ACG3D-OD4
CM-ACG3D-OD6

DC/AISG Bypass

Single Unit Model


Number
CM-ACG3-OD1
CM-ACG3-OD2
CM-ACG3-OD3
CM-ACG3-OD4
CM-ACG3-OD6

9.7 / 21.4
Comply with IEC 61000-4-5; 8kA, 8/20s

Port1
703-803
-

Port2
825-880

Port3
898.4-960

Example: View of Single Unit CM-ACG3-OD6

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Page 96 of 139

Outdoor Quad-band Combiner


CM-ACKP4-OD1A
Band 1: 698-787MHz Band 2: 806-894MHz
Band 3: 1710-1755/2110-2155MHz Band 4: 1850-1995MHz

Designed for feeder sharing and co-siting purpose


No DC bypass
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Single unit

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

698-787

806-894

1710-1755/2110-2155

Insertion Loss (dB)

1.0

Pass Band Ripple (dB)

0.5

Coupling Value at COM Port (dB)

43.52

1850-1995

362
60@698-787/806-894
80@698-787/1710-2155
80@806-894/1710-2155
60@1710-1755&2110-2155/1850-1995

Isolation between Ports (dB)

18, typical 20

Return Loss (dB)


Maximum Input Power per Port (W)

60

120
-153@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
Color

Specifications
216x183x56 / 8.5x7.2x2.2
3.6 / 7.9
RAL9002, Grey White

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)(Including 1pc 2m
grounded cable)
Lightning Protection

464x364x184 / 18.3x14.3x7.2
5.9 / 13.0
Comply with IEC 61000-4-5; 8kA, 8/20s

Block Diagram
Port 5
COM

Port 1
698-787

Coupling Port

Port 4
Port 2
Port 3
806-894 1710-1755 / 2110-2155 1850-1995

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 97 of 139

Outdoor Multi-band Combiner


CM-ADWTY5-OD6
Band 1: 678-960MHz Band 2:1710-1880MHz
Band 3:1920-2170MHz Band 4: 2300-2390MHz
Band 5: 2500-2690MHz

Co-siting purpose for feeder sharing


DC bypass@2600MHz system, to be used with Tower Mounted Amplifiers and AISG devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

678-960

1710-1880

1920-2170

0.2

Insertion Loss (dB)

2300-2390

2500-2690

0.4

Isolation between Ports(dB)

50

Return Loss (dB)

20

Maximum Input Power per Port (W)

250

Intermodulation Products

<-155 @2x43dBm

Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) ( mm) / (in)

260x240x50 / 9.4x8.3x2.0

Weight (including connectors and mounting


bracket) (kg) / (lb)

4.0 / 8.8

Colors

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall mounted

Mounting
Operating Temperature Range (C)

-40 to +65
95

Operational Humidity (%)


Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)

464x364x184 / 18.3x14.3x7.2

Shipping Weight (kg) / (lb)

5.3 / 11.7

Lightning Protection

IEC 61000-4-5; 8kA, 8/20s

Block Diagram

DC/AISG Bypass

Port 6

Port 1
678-960

Port 2
Port 3
Port 4
Port 5
1710-1880 1920-2170 2300-2390 2500-2690

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-3 / 0116

Page 98 of 139

Outdoor Dual-band Combiner


CM-AE2-ODx, CM-AE2D-ODx (x= 1, 2, 3 or 4, Preconfigured DC-pass)
Band 1:790-862MHz Band 2:880-960MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units
Single unit photo for reference

Electrical Specifications

Pass Band Frequency Range (MHz)


Parameters / Specifications

790-862

880-960

Insertion Loss (dB)

0.4

Isolation between Ports (dB)

50

Return Loss (dB)

18

Maximum Input Power per Port (W)

200
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors)


(mm) / (in)
Weight (including connectors) (kg) / (lb)

Single Unit

188x176x68 / 7.4x6.9x2.7

Double Units

188x176x138 / 7.4x6.9x5.4

Single Unit

2.4 / 5.3

Double Units

5.0 / 11.0

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

350x250x130 / 13.8x9.8x5.1

Double Units

350x250x200 / 13.8x9.8x7.9

Single Unit

2.9 / 6.4

Double Units

6.0 / 13.2

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single unit Model


Number
CM-AE2-OD1

Double units
Model Number
CM-AE2D-OD1

CM-AE2-OD2

CM-AE2D-OD2

DC Bypass @790-862

CM-AE2-OD3

CM-AE2D-OD3

DC Bypass @880-960

CM-AE2-OD4

CM-AE2D-OD4

Full DC Bypass

DC Bypass Optional

Port 3

Port 1
790-862

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 2
880-960

Example: View of Single Unit CM-AE2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0116

Page 99 of 139

Outdoor Dual Band Combiner


CM-AG2-ODx, CM-AG2D-ODx(x=1, 2, 3 or 4, Preconfigured DC-pass)
Band 1:698-806MHz Band 2:880-960MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

698-806

880-960

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

60

Return Loss (dB)

20

Maximum Input Power per Port (W)

250
-153@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

201.5x151x58 / 7.9x5.9x2.3

Double Units

201.5x151x118 / 7.9x5.9x4.6

Single Unit

2.5 / 5.5

Double Units

5.2 / 11.5

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

400x250x200 / 15.7x9.8x7.9

Double Units

410x275x245 / 16.1x10.8x9.6

Single Unit

3.8 / 8.4

Double Units

6.3 / 13.9

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single Unit Model


Number
CM-AG2-OD1

Double Unit Model


Number
CM-AG2D-OD1

CM-AG2-OD2

CM-AG2D-OD2

DC Bypass @698-806

CM-AG2-OD3

CM-AG2D-OD3

DC Bypass @880-960

CM-AG2-OD4

CM-AG2D-OD4

Full DC Bypass

DC Bypass Optional
Port 3

Port 1
698-806

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 2
880-960

Example: View of Single Unit CM-AG2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 100 of 139

Outdoor Dual Band Combiner


CM-DW2-ODxG, CM-DW2D-ODxG (x=1, 2, 3 or 4, Preconfigured DC-pass)
Band 1:1710-1880MHz Band 2:1920-2170MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1710-1880

1920-2170

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

50

Return Loss (dB)

20

Maximum Input Power per Port (W)

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors)


(mm) / (in)
Weight (including connectors) (kg) / (lb)

Single Unit

210x124x49 / 7.6x4.9x1.9

Double Units

210x124x124 / 7.6x4.9x4.9

Single Unit

1.9 / 4.2

Double Units

3.9 / 8.6

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (lb)

Single Unit

415x200x130 / 16.3x7.9x5.1

Double Units

415x200x195 / 16.3x7.9x7.7

Single Unit

2.9 / 6.3

Double Units

5.4 / 11.9

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single Unit
Model Number
CM-DW2-OD1G

Double Unit
Model Number
CM-DW2D-OD1G

CM-DW2-OD2G

CM-DW2D-OD2G

DC Bypass @1710-1880

CM-DW2-OD3G

CM-DW2D-OD3G

DC Bypass @1920-2170

CM-DW2-OD4G

CM-DW2D-OD4G

Full DC Bypass

Port 3

DC Bypass Optional

Port1
1710-1880

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 2
1920-2170

Example: View of Single Unit CM-DW2-OD4G

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-0 / 0116

Page 101 of 139

Outdoor Tri-band Combiner


CM-DWY3-ODxA, CM-DWY3D-ODxA(x=1, 2or 6, Preconfigured DC-pass)
Band 1:1710-1880MHz Band 2:1920-2170MHz
Band 3:2500-2690MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1710-1880

1920-2170

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

50

Return Loss (dB)

20

Maximum Input Power per Port (W)

2500-2690

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

240x210x50 / 9.4x8.3x2.0

Double Units

240x210x103 / 9.4x8.3x4.1

Single Unit

3.7 / 8.2

Double Units

7.0 / 15.4

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65
95

Operational Humidity (%)


Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

440x280x250 / 17.3x11.0x9.8

Double Units

505x340x225 / 19.8x13.4x8.8

Single Unit

5.4 / 11.9

Double Units

Lightning Protection

8.9 / 19.6
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram
Port 4

Single Unit Model


Number
CM-DWY3-OD1A

Double Units
Model Number
CM-DWY3D-OD1A

CM-DWY3-OD2A

CM-DWY3D-OD2A

DC Bypass @1710-1880

CM-DWY3-OD3A

CM-DWY3D-OD3A

DC Bypass @1920-2170

CM-DWY3-OD4A

CM-DWY3D-OD4A

CM-DWY3-OD5A

CM-DWY3D-OD5A

CM-DWY3-OD6A

CM-DWY3D-OD6A

DC Bypass @2500-2690
DC Bypass @1710-1880 and
@1920-2170
Full DC Bypass

DC Bypass Optional

DC/AISG Bypass

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 1
1710-1880

Port2
1920-2170

Port3
2500-2690

Example: View of Single Unit CM-DWY3-OD6A

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-0 / 0116

Page 102 of 139

Outdoor Tri-band Combiner


CM-FDW3-ODx, CM-FDW3D-ODx (x=1, 2or 6, Preconfigured DC-pass)
Band 1:380-960MHz Band 2:1710-1880MHz
Band 3:1920-2170MHz
Ultra wideband design for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

380-960

1710-1880

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

50

Return Loss (dB)

20

Maximum Input Power per Port (W)

250

1920-2170

-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

220x180x50.5 / 8.7x7.1x2.0

Double Units

220x180x103 / 8.7x7.1x4.1

Single Unit

3.0 / 6.6

Double Units

5.8 / 12.8

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

464x364x184 / 18.3x14.3x7.2

Double Units

465x365x250 / 18.3x14.4x9.8

Single Unit

4.6 / 10.1

Double Units

Lightning Protection

7.4 / 16.3
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single Unit Model


Number
CM-FDW3-OD1

Double Units
Model Number
CM-FDW3D-OD1

CM-FDW3-OD2

CM-FDW3D-OD2

DC Bypass @380-960

CM-FDW3-OD3

CM-FDW3D-OD3

DC Bypass @1710-1880

CM-FDW3-OD4

CM-FDW3D-OD4

DC Bypass @1920-2170

CM-FDW3-OD6

CM-FDW3D-OD6

Full DC Bypass

Port 4

DC Bypass Optional

Port 1
380-960

Port2
1710-1880

DC/AISG Bypass

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port3
1920-2170

Example: View of Single Unit CM-FDW3-OD6

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-1 / 0116

Page 103 of 139

Outdoor Quad-Band Combiner


CM-FDWY4-ODx, CM-FDWY4D-ODx(x=1, 2or 8, Preconfigured DC-pass)
Band 1:380-960MHz Band 2:1710-1880MHz
Band 3:1920-2170MHz Band 4:2500-2690MHz

Ultra wideband design for feeder sharing


Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units
Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

380-960

1710-1880

1920-2170

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

50

Return Loss(dB)

20

Maximum Input Power per Port (W)

250

2500-2690

-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)

Single Unit

240x210x50 / 9.4x8.3x2.0

Double Units

240x210x103 / 9.4x8.3x4.1

Weight (including connectors and mounting


bracket) (kg) / (lb)

Single Unit

3.9 / 8.6

Double Units

7.8 / 17.2

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range(C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

440x290x250 / 17.3x11.4x9.8

Double Units

520x355x250 / 20.5x14.0x9.8

Single Unit

5.2 / 11.5

Double Units

Lightning Protection

9.6 / 21.2
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram
Port 5

Single Unit Model


Number
CM-FDWY4-OD1

Double Units
Model Number
CM-FDWY4D-OD1

CM-FDWY4-OD2

CM-FDWY4D-OD2

DC Bypass @380-960

CM-FDWY4-OD3

CM-FDWY4D-OD3

DC Bypass @1710-1880

CM-FDWY4-OD4

CM-FDWY4D-OD4

DC Bypass @1920-2170

CM-FDWY4-OD5

CM-FDWY4D-OD5

DC Bypass @2500-2690

CM-FDWY4-OD8

CM-FDWY4D-OD8

Full DC Bypass

DC Bypass Optional

Port 1
380-960

Port2
1710-1880

Port3
1920-2170

DC/AISG Bypass

DC/AISG Bypass

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 4
2500-2690

Example: View of Single Unit CM-FDWY4-OD8

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-3 / 0116

Page 104 of 139

Outdoor Dual-band Combiner


CM-FK2-ODx, CM-FK2D-ODx (x=1, 2, 3 or 4, Preconfigured DC-pass)
Band 1:380-960MHz Band 2:1710-2700MHz
Ultra wideband design for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units
Single unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)

Parameters / Specifications

380-960

1710-2700

Insertion Loss (dB)

0.2

Isolation Between Ports (dB)

60

Return Loss (dB)

20

Maximum Input Power Per Port (W)

300
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

180x110x50 / 7.1x4.3x2.0

Double Units

180x110x103 / 7.1x4.3x4.1

Single Unit

2.0 / 4.4

Double Units

3.9 / 8.6

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environment Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (lb)

Single Unit

405x226x210 / 15.9x8.9x8.3

Double Units

405x225x275 / 15.9x8.9x10.8

Single Unit

3.0 / 6.6

Double Units

Lightning Protection

4.9 / 10.8
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram
Port 3

Single Unit Model


Number
CM-FK2-OD1

Double Units
Model Number
CM-FK2D-OD1

CM-FK2-OD2

CM-FK2D-OD2

DC Bypass @380-960

CM-FK2-OD3

CM-FK2D-OD3

DC Bypass @1710-2700

CM-FK2-OD4

CM-FK2D-OD4

Full DC Bypass

DC Bypass Optional

Port 1
380-960

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 2
1710-2700

Example: View of Single Unit CM-FK2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-5 / 0116

Page 105 of 139

Outdoor Tri-band Combiner


CM-FKY3-ODx, CM-FKY3D-ODx (x=1, 2or 6, Preconfigured DC-pass)
Band 1:380-960MHz Band 2:1710-2170MHz
Band 3:2300-2690MHz
Ultra wideband design for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Single Unit photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

380-960

1710-2170

2300-2690

0.3
60@380-960 / 1710-2170MHz
60@380-960 / 2300-2690MHz
55@1710-2170 / 2300-2690MHz
20

Insertion Loss (dB)


Isolation between Ports (dB)
Return Loss (dB)
Maximum Input Power per Port (W)

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

187x158x50 / 7.4x6.2x2.0

Double Units

187x158x102 / 7.4x6.2x4.0

Single Unit

2.6 / 5.7

Double Units

5.2 / 11.5

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (lb)

Single Unit

392x247x185 / 15.4x9.7x7.3

Double Units

400x300x220 / 15.7x11.8x8.7

Single Unit

3.5 / 7.7

Double Units

Lightning Protection

6.1 / 13.4
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single Unit
Model Number
CM-FKY3-OD1

Double Units
Model Number
CM-FKY3D-OD1

CM-FKY3-OD2

CM-FKY3D-OD2

DC Bypass @380-960

CM-FKY3-OD3

CM-FKY3D-OD3

DC Bypass @1710-2170

CM-FKY3-OD4

CM-FKY3D-OD4

DC Bypass @2300-2690

CM-FKY3-OD6

CM-FKY3D-OD6

Full DC Bypass

Port 4

DC Bypass Optional

Port 1
380-960
-

Port2
1710-2170

DC/AISG Bypass

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 3
2300-2690

Example: View of Single Unit CM-FKY3-OD6

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0116

Page 106 of 139

Outdoor Tri-band Combiner


CM-KTY3-OD4
Band 1:1710-2170MHz Band 2:2300-2390MHz
Band 3:2500-2690MHz
Co-siting purpose for feeder sharing
DC bypass@2500-2690MHz, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1710-2170

2300-2390

Insertion Loss (dB)

0.4

Isolation between Ports (dB)

70

Return Loss (dB)

20

Maximum Input Power per Port (W)

2500-2690

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
Color

Specifications
146x138x44.5 / 5.7x5.4x1.8
1.9 / 4.2
Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)

345x215x220 / 13.6x8.5x8.7

Shipping Weight (kg) / (lb)

2.8 / 6.2

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Block Diagram

DC/AISG Bypass

Port 4

Port1
1710-2170

Port2
2300-2390

Port3
2500-2690

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-4 / 0116

Page 107 of 139

Outdoor Dual-band Combiner


CM-KY2-ODxB, CM-KY2D-ODxB (x=1, 2or 4, Preconfigured DC-pass)
Band 1:1710-2170MHz Band 2:2300-2700MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers
and AISG devices
High isolation-minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1710-2170

2300-2700

Insertion Loss (dB)

0.3

Isolation between Ports (dB)

70

Return Loss (dB)

20

Maximum Input Power per Port (W)

300
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors)


(mm) / (in)
Weight (including connectors and mounting
bracke) (kg) / (lb)

Single Unit

142x121x69 / 5.6x4.8x2.7

Double Units

142x121x140 / 5.6x4.8x5.5

Single Unit

1.7 / 3.7

Double Units

3.4 / 7.5

Color

Light Grey

RF Connectors
Mounting
Operating Temperature Range (C)

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted
-40 to +65

Operational Humidity (%)

95

Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

350x195x140 / 13.8x7.7x5.5

Double Units

350x195x210 / 13.8x7.7x8.3

Single Unit

2.8 / 6.2

Double Units

4.6 / 10.1

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram

Single Unit Model


Number
CM-KY2-OD1B

Double Units
Model Number
CM-KY2D-OD1B

CM-KY2-OD2B

CM-KY2D-OD2B

DC Bypass @1710-2170

CM-KY2-OD3B

CM-KY2D-OD3B

DC Bypass @2300-2700

CM-KY2-OD4B

CM-KY2D-OD4B

Full DC Bypass

DC Bypass Optional

Port 3

Port 1
1710-2170

DC/AISG Bypass

DC/AISG Bypass

No DC Bypass

Port 2
2300-2700

Example: View of Single CM-KY2-OD4B

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-9 / 0116

Page 108 of 139

Outdoor Dual-band Combiner


CM-MY2-ODx, CM-MY2D-ODx (x=2 or 4, Preconfigured DC-pass)
Band 1:806-960/1710-2170MHz Band 2:2300-2700MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units
Photo for reference

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

806-960/1710-2170

2300-2700

Insertion Loss (dB)

0.3

Isolation Between Ports (dB)

70

Return Loss (dB)

20

Maximum Input Power Per Port (W)

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)

Single Unit

156x142x58 / 6.1x5.6x2.3

Double Units

156x142x118 / 6.1x5.6x4.6

Weight (including connectors and mounting


bracket) (kg) / (lb)

Single Unit

2.4 / 5.3

Double Units

4.7 / 10.4

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environment Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

365x265x230 / 14.4x10.4x9.1

Double Units

405x225x275 / 16.0x8.9x10.8

Single Unit

3.4 / 7.5

Double Units

Lightning Protection

5.7 / 12.7
Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram
Port 3

DC Bypass Optional
DC Bypass @806-960/1710-2170
Full DC Bypass

Port 1
806-960/1710-2170

DC/AISG Bypass

Double units Model


Number
CM-MY2D-OD2
CM-MY2D-OD4

DC/AISG Bypass

Single unit Model


Number
CM-MY2-OD2
CM-MY2-OD4

Port 2
2300-2700

Example: View of Single Unit CM-MY2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control:3-0-5 / 0116

Page 109 of 139

Outdoor Dual-band Combiner


CM-PK2-ODx, CM-PK2D-ODx(x=1, 2, 3 or 4, Preconfigured DC-pass)
Band 1: 1850-1910/1930-1990MHz
Band 2: 1710-1755/2110-2155MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1710-1755/2110-2155

1850-1910/1930-1990
0.3

Insertion Loss (dB)

0.2

Isolation between Bands (dB)

50

Return Loss (dB)

20

Maximum Input Power per Port (W)

250
-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)

Single Unit

167x143x45 / 6.6x5.6x1.8

Double Units

167x143x97 / 6.6x5.6x3.8

Weight (including connectors and mounting


bracket) (kg) / (lb)

Single Unit

2.1 / 4.6

Double Units

4.3 / 9.5

Color

Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65
95

Operational Humidity (%)


Environmental Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)

Single Unit

395x300x215 / 15.6x11.8x8.5

Double Units

395x300x265 / 15.6x11.8x10.4

Single Unit

4.5 / 9.9

Double Units

6.9 / 15.2

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

CM-PK2-OD2

CM-PK2D-OD2

CM-PK2-OD3

CM-PK2D-OD3

CM-PK2-OD4

CM-PK2D-OD4

Block Diagram
Port 3

DC Bypass Optional
No DC Bypass
DC Bypass @18501910/1930-1990
DC Bypass @17101755/2110-2155
Full DC Pass

DC/AISG Bypass

Double units
Model Number
CM-PK2D-OD1

DC/AISG Bypass

Single Unit
Model Number
CM-PK2-OD1

Port 1
Port 2
1850-1910/1930-1990 1710-1755/2110-2155

Example: View of Single Unit CM-PK2-OD4


Comba Telecom. All rights reserved
Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-1 / 0116

Page 110 of 139

Outdoor Tri-band Combiner


CM-PPK3-ODx, CM-PPK3D-ODx (x=1, 2or 6, Preconfigured DC-pass)
Band 1: 1850-1875/1930-1955MHz Band 2: 1885-1910/1965-1990MHz
Band 3: 1710-1755/2110-2155MHz
Co-siting purpose for feeder sharing
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
Devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Available as a single unit or double units

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications
Insertion Loss (dB)
Rejection (dB)

1850-1875/1930-1955

1885-1910/1965-1990

1710-1755/2110-2155

0.7
30@1885-1910/1965-1990
50@1710-1755/2110-2155

0.7
30@1850-1875/1930-1955
50@1710-1755/2110-2155
20

0.3
50@1850-1875/1930-1955
50@1885-1910/1965-1990

100

200

Return Loss (dB)


Maximum Input Power per Port (W)

100

-155@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (excluding connectors


and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)

Single Unit

213x196x92 / 8.4x7.7x3.6

Double Units

213x196x194 / 8.4x7.7x7.6

Single Unit

5.0 / 11.0

Double Units

10.5 / 23.1

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range(C)

-40 to +65
95

Operational Humidity (%)


Environmental Class
Shipping Dimensions, LxWxH (mm) / (in)
Shipping Weight (kg) / (Ib)

IP67
Single Unit

385x325x150 / 15.2x12.8x5.9

Double Units

505x335x375 / 19.9x13.2x14.8

Single Unit

5.6 / 12.3

Double Units

11.5 / 25.4

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information

Block Diagram
Port 4

No DC Bypass
DC Bypass @1850-1875/1930-1955
DC Bypass @1885-1910/1965-1990
DC Bypass @1710-1755/2110-2155
Full DC Bypass

DC/AISG Bypass

DC Bypass Optional

DC/AISG Bypass

Double Units
Model Number
CM-PPK3D-OD1
CM-PPK3D-OD2
CM-PPK3D-OD3
CM-PPK3D-OD4
CM-PPK3D-OD6

DC/AISG Bypass

Single Unit
Model Number
CM-PPK3-OD1
CM-PPK3-OD2
CM-PPK3-OD3
CM-PPK3-OD4
CM-PPK3-OD6

Port1
1850-1875/1930-1955

Port2
1885-1910/1965-1990

Port3
1710-1755/2110-2155

Example: View of Single Unit CM-PPK3-OD6


Comba Telecom. All rights reserved
Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Page 111 of 139

Outdoor Dual-band Combiner


CM-W2D-ODx (x=1, 2or 4, Preconfigured DC-pass)
Band 1:2110-2130&1920-1940MHz
Band 2:2160-2170&1970-1980MHz

Co-siting purpose for feeder sharing


Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG devices
High isolation minimizes interference
High power handling and low loss maximizes system performance
Built-in lightning protection
Double units

Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications

1920-1940/2110-2130

1970-1980/2160-2170

Insertion Loss (dB)

0.4

Isolation between Ports (dB)

40

Return Loss (dB)

18

Maximum Input Power per Port (W)

300
-160@2x43dBm

Intermodulation Products (in RX band)(dBc)


Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors)
(mm) / (in)
Weight (including connectors) (kg) / (lb)
Color

Specifications
230x150x90 / 9.1x5.9x3.5
3.6 / 7.9
Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole)

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environment Class

IP67

Shipping Dimensions, LxWxH (mm) / (in)

335x299x203 / 13.2x11.8x8.0

Shipping Weight (kg) / (Ib)

4.6 / 10.1

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information
DC Bypass Optional

Port 3

DC Pass @1920-1940/2110-2130

CM-W2D-OD3

DC Pass @1970-1980/2160-2170

CM-W2D-OD4

Full DC Pass

DC/AISG Bypass

No DC Pass

CM-W2D-OD2

DC/AISG Bypass

Double units
Model Number
CM-W2D-OD1

Block Diagram

Port 1
Port 2
1920-1940/2110-2130 1970-1980/2160-2170

Example: View of Single Unit CM-W2-OD4

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Page 112 of 139

Hybrid Combiner
Model

Frequency
(MHz)

Connector
Type

Mounting

Power
Handling (W)

Dimension
(mm)

COM-BD21ODN4

698-2700

DIN-Female

Pole or Wall
Mount

100

270x190x87

COM-BD21ODN8

698-2700

DIN-Female

Pole or Wall
Mount

50

150x172x46

COM-BD21ONN5

698-2700

N-Female

Pole or Wall
Mount

50

150x172x46

Page 113 of 139

2:1 Hybrid Combiner


COM-BD21ODN4

Wideband covering 698-2700MHz


High input power handling capability
Low insertion loss and VSWR, high isolation
Integrating two operators services into an existing in-building antenna distribution system
Terminated two low PIM performance cable load

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

698-2700
3.10.6@698-806MHz
3.10.5@806-2700MHz
30*@806-960MHz
23*@2170-2700MHz
25*@ Others
18

Coupling Attenuation (dB)


Isolation between Ports (dB)
Return Loss (dB)

-155@2x43dBm

Intermodulation Products (dBc)


Maximum Input Power per Port (W)

100

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
Color

Specifications
270x190x87 / 10.6x7.5x3.4
6.4 / 14.1
Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP66

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (lb)
* Valid if all ports are terminated with 50 load

440x290x250 / 17.3x11.4x9.8
8.0 / 17.6

Block Diagram
1 Output
Load
HC

* 2 Input
DC/AISG Bypass

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-4 / 0116

Page 114 of 139

2:1 Hybrid Combiner


COM-BD21ODN8

Wideband covering 698-2700MHz


Low insertion loss and VSWR, high isolation
Integrating two operators services into an existing in-building antenna distribution system.
Terminated with low PIM performance cable load

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications
698-2700
3.10.6@698-806 MHz
3.10.5@806-2700 MHz
25*

Coupling Attenuation (dB)


Isolation between Ports (dB)

18,typical 20

Return Loss (dB)

-153@2x43dBm

Intermodulation Products (dBc)


Maximum Input Power per Port (W)

50

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
Color

Specifications
150x172x46 / 6.0x6.8x1.8
2.5 / 5.5
Light Grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class

IP66

Shipping Dimensions, LxWxH (mm) / (in)


Shipping Weight (kg) / (Ib)
* Valid if all ports are terminated with 50 load

405x226x220 / 16.0x8.9x8.7
3.6 / 7.9

Block Diagram
1 Output
Load
HC

* 2 Input
DC/AISG Bypass

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 115 of 139

2:1 Hybrid Combiner


COM-BD21ONN5

Wideband covering 698-2700MHz


Low insertion loss and VSWR, high isolation
Integrating two operators services into an existing in-building antenna distribution system
Terminated with low PIM performance cable load

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications
698-2700
3.10.6@698-806 MHz
3.10.5@806-2700 MHz
25*

Coupling Attenuation (dB)


Isolation between Ports (dB)

18,typical 20

Return Loss (dB)

-153@2x43dBm

Intermodulation Products (dBc)


Maximum Input Power per Port (W)

50

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (including connectors and mounting
bracket) (kg) / (lb)
Color

Specifications
150x172x46 / 6.0x6.8x1.8
2.3 / 5.1
Light Grey

RF Connectors

N-Female
Pole (clamps included for 35-125mm pole) or Wall Mounted

Mounting
Operating Temperature Range (C)

-40 to +65

Operational Humidity (%)

95

Environmental Class
Shipping Dimensions, LxWxH (mm) / (in)

IP66

Shipping Weight (kg) / (Ib)

405x226x220 / 16.0x8.9x8.7
3.4 / 7.5

* Valid if all ports are terminated with 50 load

Block Diagram
1 Output
Load
HC

* 2 Input
DC/AISG Bypass

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 2-0-0 / 0116

Page 116 of 139

Directional Coupler
Model

Frequency
(MHz)

Connector
Type

Coupling Factor
(dB)

Power
Handling
(W)

PIM (dBc)
@2x43dbm

Dimension
(mm)

DC-Rxx-OD500C(H)

698-2700

DIN-Female

5, 6, 7, 8, 10, 13, 15, 20, 30, 40

500

-150

164x43x35

DC-Rxx-ON300C(H)

698-2700

N-Female

5, 6, 7, 8, 10, 13, 15, 20, 30, 40

300

-150

158x61x21.5

Page 117 of 139

Wide-band Directional Coupler


DC-Rxx-OD500C(H) (xx=05, 06or 40, Preconfigured Coupling Value)
5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, D-Female, 500W

Wide-band design covers 698-2700MHz range


Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.

Electrical Specifications
Parameters

DC-R05OD500C(H)

DC-R06OD500C(H)

Frequency Range (MHz)


Coupling Value (dB)

Specifications
DC-R07OD500C(H)

DC-R08OD500C(H)

DC-R10OD500C(H)

698-2700
5

10

Coupling Tolerance (dB)

0.8

0.8

0.8

0.8

0.8

Main Line Loss (dB)

2.1

1.6

1.4

1.2

0.7

Isolation (dB)

25

26

27

28

30

Input Port VSWR


Intermodulation Products (dBc)

1.25
-150@2x43dBm

Input Average Power, Maximum (W)

500

Peak Power, Maximum (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions,
LxWxH
(including
connectors) (mm) / (in)
Weight (including connectors) (kg) / (Ib)
Connector Type
Operational Temperature (C)
Operational Humidity (%)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
164x64x35 / 6.5x2.5x1.4
0.75 / 1.65
DIN-Female
-40 to +60
95
180x80x45 / 7.1x3.1x1.8
0.8 / 1.8
IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0715

Page 118 of 139

Wide-band Directional Coupler


DC-Rxx-OD500C(H) (xx=05, 06or 40, Preconfigured Coupling Value)
5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, D-Female, 500W

Wide-band design covers 698-2700MHz range


Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.

Electrical Specifications
Specifications
Parameters

DC-R13OD500C(H)

DC-R15OD500C(H)

Frequency Range (MHz)

DC-R20OD500C(H)

DC-R30OD500C(H)

DC-R40OD500C(H)

698-2700

Coupling Value (dB)

13

15

20

30

40

Coupling Tolerance (dB)

1.2

1.5

1.5

Main Line Loss (dB)

0.5

0.4

0.3

0.2

0.2

Isolation (dB)

33

35

35

45

55

Input Port VSWR


Intermodulation Products (dBc)

1.25
-150@2x43dBm

Input Average Power, Maximum (W)

500

Peak Power, Maximum (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions,
LxWxH
(including
connectors) (mm) / (in)
Weight (including connectors) (kg) / (Ib)
Connector Type
Operational Temperature (C)
Operational Humidity (%)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
164x64x35 / 6.5x2.5x1.4
0.75 / 1.65
DIN-Female
-40 to +60
95
180x80x45 / 7.1x3.1x1.8
0.8 / 1.8
IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0715

Page 119 of 139

Wide-band Directional Coupler


DC-Rxx-ON300C(H) (xx=05, 06or 40, Preconfigured Coupling Value)
5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, N-Female, 300W

Wide-band design covers 698-2700MHz range


Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.

Electrical Specifications
Parameters

DC-R05ON300C(H)

DC-R06ON300C(H)

Frequency Range (MHz)


Coupling Value (dB)

Specifications
DC-R07ON300C(H)

DC-R08ON300C(H)

DC-R10ON300C(H)

698-2700
5

10

Coupling Tolerance (dB)

0.8

0.8

0.8

0.8

0.8

Main Line Loss (dB)

2.1

1.6

1.4

1.2

0.7

Isolation (dB)

25

26

27

28

30

Input Port VSWR


Intermodulation Products (dBc)

1.25
-150@2x43dBm

Input Average Power, Maximum (W)

300

Peak Power , Maximum (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (including
connectors) (mm) / (in)
Weight (including connectors) (kg) / (Ib)
Connector Type
Operational Temperature (C)
Operational Humidity (%)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
158x61x21.5 / 6.2x2.4x0.8
0.3 / 0.7
N-Female
-40 to +60
95
180x75x30 / 7.1x3.0x1.2
0.4 / 0.9
IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-5 / 0715

Page 120 of 139

Wide-band Directional Coupler


DC-Rxx-ON300C(H) (xx=05, 06or 40, Preconfigured Coupling Value)
5, 6, 7, 8, 10, 13, 15, 20, 30, 40dB, 698-2700MHz, N-Female, 300W

Wide-band design covers 698-2700MHz range


Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.

Electrical Specifications
Parameters

DC-R13ON300C(H)

DC-R15ON300C(H)

Frequency Range (MHz)

Specifications
DC-R20ON300C(H)

DC-R30ON300C(H)

DC-R40ON300C(H)

698-2700

Coupling Value (dB)

13

15

20

30

40

Coupling Tolerance (dB)

1.2

1.5

1.5

Main Line Loss (dB)

0.5

0.4

0.3

0.2

0.2

Isolation (dB)

33

35

40

45

55

Input Port VSWR


Intermodulation Products (dBc)

1.25
-150@2x43dBm

Input Average Power, Maximum (W)

300

Peak Power (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH
(including connectors) (mm) / (in)
Weight (including connectors) (kg) / (Ib)
Connector Type
Operational Temperature (C)
Operational Humidity (%)
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class

Specifications
158x61x21.5 / 6.2x2.4x0.8
0.3 / 0.7
N-Female
-40 to +60
95
180x75x30 / 7.1x3.0x1.2
0.4 / 0.9
IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-5 / 0715

Page 121 of 139

Hybrid Coupler
Model

Frequency
(MHz)

Connector
Type

Power
Handling
(W)

Dimension
(mm)

HC-R4-OD200L,
HC-R4-ON200L

698-2700

DIN-Female
N-Female

200

250x100x60
250x100x54

HC-R-OD500L(XH)

698-2700

DIN-Female

500

127x86x37

HC-R-ON300L(H)

698-2700

N-Female

300

127x80x24.2

Page 122 of 139

4 IN 4 OUT Wideband Hybrid Coupler


HC-R4-OD200L, HC-R4-ON200L
698-2700MHz, Din-Female / N-Female, 200W

Compact and cost effective design for same band combining of 698-2700MHz signals
High inter-band isolation and input power handling
Low insertion loss
The use of fewer than 4 inputs or outputs is possible. Any unused input&output ports have
to be terminated with low-power 50 loads
Suitable for indoor or outdoor applications
Din type photo for reference

Electrical Specifications
Specifications

Parameters

HC-R4-OD200L

HC-R4-ON200L

Frequency Range (MHz)

698-2700

Input Average Power, Maximum (W)

200

Peak Power (W)

800

Insertion Loss (dB)

0.5

Coupling Value (dB)

6.00.6
23*
1.22@698-2500MHz
1.30@2500-2700MHz
-150@2x43dBm

Isolation between Ports (dB)


VSWR
Intermodulation Products (dBc)
Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH
(excluding connectors) (mm) / (in)
Weight (including connectors) (kg) / (lb)
Connector Type

Specifications
250x100x60 / 9.8x3.9x2.4
2.2 / 4.9

1.6 / 3.5

8xDIN-Female

8xN-Female

Operating Temperature Range (C)

-40 to +60
95

Operational Humidity (%)


Environmental Class
Shipping
Dimensions
LxWxH (mm) / (in)
Shipping Weight (kg) / (lb)

250x100x54 / 9.8x3.9x2.1

IP65
One unit

285x225x105 / 11.2x8.9x4.1

Ten units

580x480x330 / 22.8x18.9x13.0

One unit

Ten units
* Valid if all ports are terminated with 50 load

2.6 / 5.7

2.6 / 5.7

24.8 / 54.7

24.8 / 54.7

Outline Drawing

Din type connector


Comba Telecom. All rights reserved
Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-3 / 0116

N type connector

Page 123 of 139

2 IN 2 OUT Wideband Hybrid Coupler


HC-R-OD500L(XH)
698-2700MHz, Din-Female, 500W

Wideband covering 698-2700MHz


High input power handling capability
Low insertion loss and VSWR, high isolation
Integrating two operators services into an existing in-building antenna
distribution system

Electrical Specifications
Parameters
Frequency Range (MHz)

Specifications
698-2700

Input Average Power, Maximum (W)

500

Peak Power (W)

1000

Insertion Loss (dB)

0.1

Coupling Value (dB)

3.1

Coupling Tolerance (dB)

0.5

Isolation Between Ports (dB)

25*

VSWR
Intermodulation Products(dBc)
Impedance ()

1.25*
-153@2x43dBm
50

Mechanical Specifications
Parameters
Dimensions, LxWxH
(including connectors) (mm) / (in)
Weight (including connectors) (kg) / (lb)
Connector Type
Operating Temperature Range (C)
Operational Humidity (%)
Shipping Dimensions, LxWxH (mm) / (in)
Shipping Weight (kg) / (Ib)
Environmental Class
* Valid if all ports are terminated with 50 load

Specifications
127x86x37 / 5.0x3.4x1.5
0.9 / 2.0
7/16 DIN-Female
-40 to +60
95
170x100x40 / 6.7x3.9x1.6
1.1 / 2.4
IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0715

Page 124 of 139

2 IN 2 OUT Wideband Hybrid Coupler


HC-R-ON300L(H)
698-2700MHz, N-Female, 300W

Wideband covering 698-2700MHz


High input power handling capability
Low insertion loss and VSWR, high isolation
Integrating two operators services into an existing in-building antenna
distribution system

Electrical Specifications
Parameters

Specifications
698-2700

Frequency Range (MHz)


Input Average Power, Maximum (W)

300

Peak Power (W)

1000

Insertion Loss (dB)

0.1

Coupling Value (dB)

3.1

Coupling Tolerance (dB)

0.5
25*

Isolation Between Ports (dB)

1.25*

VSWR

-150@2x43dBm

Intermodulation Products (dBc)


Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH
(including connectors) (mm) / (in)
Weight (including connectors) (kg) / (lb)

Specifications
127x80x24.2 / 5.0x3.1x1.0
0.4 / 0.9

Connector Type

N-Female

Operating Temperature Range (C)

-40 to +60
95

Operational Humidity (%)


Shipping Dimensions, LxWxH (mm) / (in)

163x87x35 / 6.4x3.4x1.4

Shipping Weight (kg) / (Ib)

0.42 / 0.9

Environmental Class
* Valid if all ports are terminated with 50 load

IP65

Outline Drawing

IN

IN

OUT

OUT

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0715

Page 125 of 139

Power Splitter
Model

Frequency
(MHz)

Type

Connector
Type

Power
Handling
(W)

2 way
PS-R2-OD500C(XH), PS-R3-OD500C(XH),
PS-R4-OD500C(XH)

PS-R2-ON500C(H), PS-R3-ON500C(H),
PS-R4-ON500C(H)

698-2700

698-2700

3 way

Dimension
(mm)
229.9x81.4x38.0

DIN-Female

500

248.1x81.4x38.0

4 way

270.6x80.2x38.0

2 way

214.8x60.6x25.0

3 way
4 way

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-2 / 0414

N-Female

500

269.4x60.6x25.0
270.6x60.6x42.8

Page 126 of 139

Wideband Reactive Power Splitter


PS-R2-OD500C(XH), PS-R3-OD500C(XH), PS-R4-OD500C(XH)
2/3/4way, 698-2700MHz, Din-Female, 500W

Wide-band design covers 698-2700MHz range


High input power handling capability
Low loss, flat response and even output
High reliability

Electrical Specifications
Specifications
Parameters

PS-R2-OD500C(XH)
2 Ways

Frequency (MHz)
Splitting Loss (dB)

PS-R3-OD500C(XH)

PS-R4-OD500C(XH)

3 Ways

4 Ways

698-2700
3.0

Insertion Loss (dB)

4.8

6.0

0.3

Input Port VSWR

1.22

Intermodulation Products (dBc)

-153@2x43dBm

Input Average Power, Maximum (W)

500

Peak Power, Maximum (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions LxWxH (mm) / (in)
Weight (kg) / (lb)

Specifications
2 Ways

3 Ways

4 Ways

229.9x81.4x38.0 / 9.1x3.2x1.5

248.1x81.4x38.0 / 9.8x3.2x1.5

270.6x80.2x38.0 / 10.7x3.2x1.5

1.1 / 2.4

1.2 / 2.6

1.3 / 2.9

Connector Type

7/16 DIN-Female

Operational Temperature (C)

-40 to +60
95

Operational Humidity (%)


Shipping Dimensions LxWxH (mm) / (in)
Shipping Weight (kg) / (lb)

239.9x86.4x43.0 / 9.4x3.4x1.7

258.1x86.4x43 / 10.2x3.4x1.7

280.6x85.2x43 / 11.0x3.4x1.7

1.2 / 2.6

1.3 / 2.9

1.4 / 3.1

Environmental Class

IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-3 / 0414

Page 127 of 139

Wideband Reactive Power Splitter


PS-R2-ON500C(H), PS-R3-ON500C(H), PS-R4-ON500C(H)
2/3/4way, 698-2700MHz, N-Female, 500W

Wide-band design covers 698-2700MHz range


High input power handling capability
Low loss, flat response and even output
High reliability

Electrical Specifications
Specifications
Parameters

PS-R2-ON500C(H)
2 Ways

Frequency Range (MHz)


Splitting Loss (dB)

PS-R3-ON500C(H)

PS-R4-ON500C(H)

3 Ways

4 Ways

698-2700
3.1

5.0

6.3

0.1

Insertion Loss (dB)

1.20

Input Port VSWR

-150@2x43dBm

Intermodulation Products (dBc)


Input Average Power, Maximum (W)

500

Peak Power, Maximum (W)

1000

Impedance ()

50

Mechanical Specifications
Parameters
Dimensions, LxWxH (mm) / (in)
Weight (including connectors) (kg) / (lb)

Specifications
2 Ways

3 Ways

4 Ways

214.8x60.6x25.0 / 8.5x2.4x1.0

269.4x60.6x25.0 / 10.6x2.4x1.0

270.6x60.6x42.8 / 10.7x2.4x1.7

0.35 / 0.77

0.41 / 0.90

0.47 / 1.05

Connector Type

N-Female

Operational Temperature (C)

-40 to +60
95

Operational Humidity (%)


Shipping Dimensions LxWxH (mm) / (in)
Shipping Weight (kg) / (lb)

240x80x35 / 9.4x3.1x1.4

280x80x35 / 11.0x3.1x1.4

280x80x50 / 11.0x3.1x2.0

0.37 / 0.82

0.43 / 0.95

0.51 / 1.12

Environmental Class

IP65

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-2 / 0414

Page 128 of 139

Filter
Model

FP-G70-OD01

Frequency
(MHz)

Isolation (dB)

Insertion loss (dB)

Connector
Type

Power
Handling
(W)

890-960

35@885-886.8MHz
50@790-885MHz

2.1@890-890.4MHz
1.6@890.4-892MHz
1.2@892-898MHz
0.7@898-915MHz
0.3@935-960MHz

DIN-Female

200

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Dimension
(mm)

31012458

Page 129 of 139

Band Pass Filter


FP-G70-OD01
Pass Band: 890-960MHz

200W High power handling


Low Return Loss maximizes system performance
Low Intermodulation
Compact minimizes space requirements

Electrical Specifications
Frequency Range (MHz)
Parameters / Specifications

890-960
2.1@890-890.4MHz
1.6@890.4-892MHz
1.2@892-898MHz
0.7@898-915MHz
0.3@935-960MHz
2.0
35@885-886.8MHz
50@790-885MHz
20 (Normal)
18 (Extreme)
200

Insertion Loss(dB)

Passband Ripple (dB)


Out of Band Rejection (dB)
Return Loss
Power Handling Continuous(W)
Intermodulation products in Rx band
(2x43 dBm Carrier) (dBc)
Impedance ()

-150
50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm) / (in)
Weight (kg) / (lb) (Estimated)

Specifications
31012458 / 12.2x4.9x2.3
2.7 / 6.0

Color

Light grey

RF Connectors

7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mounted

Mounting
Operating Temperature Range (C)

-20 to +65

Operational Humidity (%)

<95

Environment Class

IP66

Shipping Dimensions, LxWxH (mm) / (in)

500220220 / 19.78.78.7

Shipping Weight (kg) / (Ib)

4.2 / 9.3

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

GND

PORT2

PORT1

Outline Drawing

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 1-0-0 / 0116

Page 130 of 139

Multiple Operator Combiner


Model

Frequency
(MHz)

Connector
Type

Dimension (mm)

POI-BD92ONY5

2xTetra Band, 1x800MHz, 4x900MHz,


4x1800MHz, 4x2100MHz, 1x2300MHz

N-Female

280x240x178

POI-CDG4IDN1

1x CDMA800, 1x GSM900, 1x DCS1800,


2x FDD-LTE1.8, 1x WCDMA, 1x FDD-LTE2.1,
1x TD-LTE(F), 1x TD-LTE(E)

Din-Female

482x430x577

@ Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 0-0-3 / 1214

Page 131 of 1

Multi Operator Combiner


POI-BD92ONY5
1x CDMA800, 1x GSM900, 1x DCS1800, 2x FDD-LTE1.8, 1x WCDMA,
1x FDD-LTE2.1, 1x TD-LTE(F), 1x TD-LTE(E)
High input power of 1000W
Low insertion loss and passive intermodulation.
High isolation.
Including monitor, supporting local/remote monitor

Electrical Specifications
Parameters

Specifications

Frequency (MHz) / Input Ports

CT CDMA800

820-835/865-880

CMCC GSM900

889-915/934-960

CMCC DCS1800

1710-1735/1805-1830

UNICOM FDD-LTE1.8

1735-1765/1830-1860

CT FDD-LTE1.8

1765-1785/1860-1880

CT FDD-LTE2.1

1920-1940/2110-2130

UNICOM WCDMA

1940-1980/2130-2170

CMCC TD-LTE(F)

1885-1915

CMCC TD-LTE(E)

2320-2370
5.5

Insertion Loss(dB)
Pass-Band Ripple(dB)

Isolation (dB)

Return Loss(dB)
IM3 ( 2x43 dBm Carrier, in RX band)(dBc)
Input Power per Port-BTS
Output Power per Port-ANT
Impedance ()

1.5
25 @ UNICOM LTE1.8 / CT LTE1.8
25 @ CMCC DCS / UNICOM LTE1.8
25 @ CT LTE2.1 / WCDMA
50 @ CMCC DCS / CT LTE1.8
50 @ CT LTE1.8 / TD-F
50 @ CT LTE2.1 / TD-F
80 @ Other Ports
>18
-150@2x43dBm
200(Avg.)
1000(Peak)
500(Avg.)
2500(Peak)
50

Mechanical Specifications
Parameters

Specifications

Dimensions, LxWxH (mm) / (in)


Weight (kg) / (Ib)

13.4 / 29.5

Number of Input Ports - Duplex


Number of Output Ports - Duplex
RF Connectors

280x240x178 / 11.0x9.5x7.0

Input ports
Output ports

Operating Temperature Range (C)


Operational Humidity (%)
Environment Class
Mounting
Shipping Dimensions, HxWxD (mm) / (in)
Shipping Weight (kg) / (Ib)

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 1015

9
2
N-Female
7/16 DIN-Female
-44 to +55
5 to 98
IP65
Wall Mounting
450x400x250 / 17.7x15.7x9.8
15.0 / 33.1

Page 132 of 139

Monitor Specifications
Parameters

Specifications

Support (Y/N)

Alarm (Y/N)

Input Power Detect ThresholddB

Output Power Detect ThresholddB

Load / Open

Interrupted Power Alarm (Power Supply by Backup Battery)

LED

Return Loss Detect Threshold


Temperature Monitoring (oC)
Power Alarm
Power Supply Indicators
Alarm Indicators

LED

RS-232

RS-485 and RJ-45

Remote Communication Transmission

Optional

Local Monitoring Port


RMON Port
Wireless Modem

Block Diagram

CDMA800

820-835
865-880

GSM900

889-915
934-960

FDD-LTE1.8

TD-LTE(F)

WCDMA

1735-1765
1830-1860
1885-1915

1940-1980
2130-2170
2320-2370

30

ANT1

TD-LTE(E)

30
DCS1800

1710-1735
1805-1830

FDD-LTE1.8

1765-1785
1860-1880

FDD-LTE2.1

1920-1940
2110-2130

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 1015

ANT2

Page 133 of 139

Modular Multi Operator Combiner


POI-CDG4IDN1
2xTetra Band, 1x800MHz, 4x900MHz, 4x1800MHz, 4x2100MHz,
1x2300MHz
Permits combining of Tetra/800/900/1800/2100/2300 technologies
Scalable design for easily upgrading to support 2600MHz (Optional via
external unit to be purchased separately)
Excellent passive inter-modulation performance

Electrical Specifications
Parameters / Specifications
Input Port

-Input Port Information (MHz)

Frequency Range

-TETRA 1

TX/RX

806-824/851-869

-TETRA 2

TX/RX

806-824/851-869

- 800

TX/RX

825-840/870-885

- 900-A

TX/RX

890-915/935-960

- 900-B

TX/RX

890-915/935-960

- 900-C

TX/RX

890-915/935-960

- 900-D

TX/RX

890-915/935-960

- 1800-A

TX/RX

1710-1785/1805-1880

- 1800-B

TX/RX

1710-1785/1805-1880

- 1800-C

TX/RX

1710-1785/1805-1880

- 1800-D

TX/RX

1710-1785/1805-1880

- 2100-A

TX/RX

1920-1980/2110-2170

- 2100-B

TX/RX

1920-1980/2110-2170

- 2100-C

TX/RX

1920-1980/2110-2170

- 2100-D

TX/RX

1920-1980/2110-2170

- 2300

TX/RX

Insertion Loss(dB)
Isolation (dB)
Return Loss(dB)
Monitor Port Coupling value (dB)
Maximum Input Power per Port (W)
-TX
Inter-modulation in Rx band (dBc)
Impedance ()

2300-2400
<8.0
25 @same band
25@Tetra / 800
80 @cross band
>18
302
200(Avg.)
1000(Peak)
-155 @2x43dBm(Reverse)
50

Mechanical Specifications
Parameters
Dimensions, LxWxH (excluding connectors
and mounting bracket) (mm)/ (in)
Weight (including connectors and mounting
bracket)( kg)/ (lb)
Input-Duplex
Connector Number and
Output-Duplex
Type
Monitor ports
Mounting
Operating Temperature Range(C)
Operational Humidity (%)
Environment Class
Shipping Dimensions, LxWxH (mm)/ (in)
Shipping Weight (kg)/ (lb)

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Specifications
482x430x577 / 19.0x16.9x22.7
58.0 / 127.9
16 x 7/16 Din-Female
4 x 7/16 Din-Female
4 x N-Female
Floor Standing
-10 to +60
95
Indoor
83.0 / 183.0
830x680x760 / 32.7x26.8x29.9

Page 134 of 139

Block Diagram
800
900-C
1800-C
2100-C
2300

825-840/870-885

Module 1
Common
Module

890-915/935-960
1710-1785/1805-1880
1920-1980/2110-2170
2300-2400

Module 1

TETRA-1
900 - B
1800-B
2100-B

806-824/851-869
890-915/935-960
1710-1785/1805-1880
1920-1980/2110-2170

ANT1

Module 1

TETRA-2
900- A
1800-A
2100-A

ANT2

806-824/851-869
890-915/935-960
ANT3

1710-1785/1805-1880

ANT4

1920-1980/2110-2170

Module 1

Load
890-915/935-960
900-D
1800-D
2100-D

1710-1785/1805-1880
1920-1980/2110-2170

TX/RX Unit

Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers requirements.
DS-Control: 3-0-0 / 0116

Page 135 of 139

This page intentionally left blank

Page 136 of 139

General Enquiries
comba@comba-telecom.com
Tel: + 852 2636 6861
Fax: + 852 2637 0966

Sales Enquiries
sales@comba-telecom.com

Support & Technical Services


support@comba-telecom.com

Marketing
marketing@comba-telecom.com

Investor Relations
investorrelations@comba-telecom.com

HR
hr.hk@comba-telecom.com
Website
http://www.comba-telecom.com/
Website Feedback
webmaster@comba-telecom.com

China Headquarters
Comba Telecom Systems China Ltd
Add: No.10 Shenzhou Road,
Guangzhou Science City, China
Tel: +8620 2839 0000
Fax: +8620 2839 0136
Corporate & APAC Headquarters
Comba Telecom Systems Holdings Ltd
Add: 611 East Wing, No.8 Science Park West Avenue,
Hong Kong Science Park, Hong Kong
Tel:

+852 2636 6861

Fax: +852 2637 0966 / +852 2116 6055


Middle East Headquarters
Comba Telecom Limited
Add: Unit 112, Building 5, Gold and Diamond Park,
Al Qouz, Dubai, UAE
Tel: +971 0 4 346 7277
Fax: +971 0 4 346 7288
Europe Headquarters
Comba Telecom Systems AB
Add: Gustavslundsvagen 147,
SE-167 51 Bromma, Stockholm,
Sweden
Tel: +46 8 253 870
Fax: +46 8 253 871
Caribbean and Latin America Headquarters
Comba Telecom Ltda
Add: Av. Doutor Chucri Zaidan n29 29andar Conj. 2910/2911,
Vila Cordeiro, Edificio Capital Corporate,
04583-110, Sao Paulo, Brazil
Tel: +55 11 3509 4800
Fax: +55 11 3509 4833
North America Headquarters
Comba Telecom Inc.
Add: 235 Charcot Ave, San Jose, CA 95131, USA
Tel: +1 408 526 0180
Fax: +1 408 526 0181
India Office (Operations Office)
Comba Telecom India P Ltd
Add: G-4 Sector 63, Noida 201301 U.P, India
Tel: +91 120-4599000
Fax: +91 120-4599001

For more local offices information,


Please visit our website
www.comba-telecom.com

Anda mungkin juga menyukai