Anda di halaman 1dari 1

PipelineCapacityAndHydraulicReview

No
1
2
3
4
5
6
7
8
9
10
11
12

Pipesegment
3"FlowlinefromASDJ93toSTLK
3"FlowlinefromASDJ97toSTLL
3"FlowlinefromASDJ98toSTLL
3"FlowlinefromASDJ100toSTLJ
3"FlowlinefromASDJ01TtoSTLB
3"FlowlinefromASD02STtoSTLC
3"FlowlinefromASD06STtoSTLC
3"FlowlinefromASD24toSTLC
3"FlowlinefromASD25toSTLC
4"FlowlinefromASDJ94toMDLMANIFOLD
6"FlowlinefromBSTNtoJumpASDJ57
6"FlowlinefromSTLJtoSatK

ActualLiquidFlow, ActualGasFlow,
BPD
MSCFD
1,429
321
683
680
375
570
701
285
835
824
11,272
4,212

1,942
527
504
945
215
321
320
3,809
2,876
3,549
7,576
3,964

Length,ft

di,Inches

Pupstream,
Psia

R,Ft3/Barrels

T,R

Sg

Sl

3,886.80
3,099.60
3,122.56
3,801.52
1,328.40
7,383.28
3,247.20
8,905.20
9,144.64
8,819.92
18,794.40
5,677.68

3.068
3.068
3.068
3.068
3.068
3.068
3.068
3.068
3.068
4.03
6.07
6.07

250
250
270
260
170
90
120
150
210
500
130
280

1.36
1.64
0.74
1.39
0.57
0.56
0.46
13.36
3.44
4.31
0.67
0.94

0.903
0.903
0.903
0.903
0.903
0.903
0.903
0.903
0.903
0.903
0.903
0.903

628
628
616
624
624
618
618
618
624
616
618
628

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85

m,
Lbs/ft3

W,Lbs/Hr

52 17,737.90
52 3,984.70
53 8,477.07
52 8,440.75
53 4,654.19
52 7,074.36
53 8,700.07
43 3,544.72
51 10,368.29
52 10,233.18
52 139,901.18
53 52,279.11

P,
Psi/100ft

P,Psi

0.11
0.01
0.03
0.03
0.01
0.02
0.03
0.01
0.04
0.01
0.23
0.03

4.30
0.17
0.78
0.95
0.10
1.30
0.86
0.48
3.56
0.84
42.65
1.79

Average
Liquidplus
LiquidFlow
vaporFlow
Velocity
rate(BPD)
(ft/s)
1,450.21 1.85
326.80 0.42
687.77 0.88
689.85 0.88
378.34 0.48
579.63 0.74
708.02 0.90
356.08 0.45
873.26 1.11
843.31 0.62
11,428.13 3.72
4,249.60 1.38

Ve,ft/s

A,Sq
Inches

NPS,
Inches

13.83
13.85
13.78
13.83
13.79
13.84
13.80
15.33
14.04
13.88
13.82
13.79

0.69
0.69
0.68
0.69
0.68
0.69
0.68
0.76
0.70
0.69
0.69
0.68

0.935205
0.935958
0.933365
0.935124
0.933801
0.935648
0.934055
0.985604
0.942343
0.937294
0.934949
0.933822

3
3
3
3
3
3
3
3
3
4
6
6

Note:
CalculationbasedonAPI14E(RP14E)FifthEdition,October1,1991

Equation:
DP=PressureDrop,Psi/100ft
P=OperatingPressure,Psia
R=GasLiquidRatio,ft3/BarrelsatStandardcondition
T=OperatingTemperature,R
Z=CompressibilityFactor
di=Insidediameter,inches
m=Gas/LiquidDensityatflowingpressureandtemperature,Lbs/ft3
W=TotalLiquidplusvaporrate,Lbs/Hr
Sg=GasSpecificgravity
Sl=LiquidSpecificGravity
Ql=LiquidFlowRate,BPD
Qg=GasFlowRate,MSCFD
A=Minimumpipecrosssectionalflowarearequired,Sqinches
Ve=Fluiderosionalvelocity,Ft/s
D=PipeDiameterrequired,Inches

Note:

1 Productiondatausedincalculationaboveisbasedonwellproductiontest
2 Compressibilityfactor,Fluiddensity,andgasdensityaredataassumptionforsimplifyingcalculation

Final
Pressure
atpipe
end(Psig)
245.70
249.83
269.22
259.05
169.90
88.70
119.14
149.52
206.44
499.16
87.35
278.21

Upstream
Pressure
(Psig)

Conclusion

230.00
230.00
250.00
240.00
90.00
85.00
85.00
85.00
85.00
450.00
70.00
250.00

OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure
OK,NoBackpressure

Anda mungkin juga menyukai