Slimpak

In-Line Twin Duct Fans

In-Line Twin Duct Fans

Wiring Diagrams 230V 1PH 50Hz Supply

Wiring Diagrams 230V 1PH 50Hz Supply

1 Phase Supply
(220-240V 50 Hz).

FUSE

L
N
5
4
3
L
N
5
4
3

REMOTE VISUAL
CONTROLLER
CONNECTIONS

240V
INPUT

24V AC

N
L1
L2
L3
TK
TK

240V
INPUT
FAN 2
OUTPUT

ITC (Stk Ref 103 14 200)


ITC-DS (Stk Ref 103 14 210)

A
K
A
K
FS
FG
S1
SG

N L1 L2 L3

E N L

INSERT LINK FOR


24HR CHANGE OVER
(ITC-DS ONLY)

LED 1

L
N

E
N
L1
L2
L3
TK
TK

LED 2
FAN 1
OUTPUT

LK1

LINK

Fan No 2
Terminals.

L
N
5
4
3

FAN 2 FAN 1
FAIL FAIL

Select the required Sensor.

Ambient Response
Ecotronic
Visionex PIR
Humidity Sensor Humidity Sensor
(45 07 26)
(56 35 50)
(56 35 32)

E D C B A

SENSOR
CONNECTIONS

L
N

240 Volt D.O.L. Starter


A suitable sized overload
relay must be fitted to
provide motor protection.

~N

Relay (by others) to


have a 240V A.C.
Coil and a 2.5A
inductive contact.

Switched Fused Spur


L

FUSE

103 14 103

N.B. Links between terminals


1 to A1, 3 to 6, 5 to 95 and
24 to 96 must be FITTED.

95

23

96

24

1 Phase Auto
Transformer
Speed Controller.

A2

PLEASE NOTE: IF EXTENAL


SENSOR/SENSORS ARE USED TO CONTROL
THE FAN REMOVE THE LINK FROM S1 TO SG.

A1

SLPT 200
SLPT 250
SLPT 315

Fan No 1
Terminals.

N L1

Fan No 2
Terminals.

N1 L2

Fan No 1
Terminals.

Fan No 2
Terminals.

SLPT 200
SLPT 250
SLPT 315

SLPT 200
SLPT 250
SLPT 315

OPTIONAL EXTERNAL SENSORS.


PLEASE NOTE: NO TESTS HAVE BEEN CARRIED OUT
REGARDING THE SUITABILITY OF MULTI SENSOR
CONTROL. VENT-AXIA RECOMMEND A MAXIMUM OF
FIVE EXTERNAL SENSORS.

111

Dimensions (mm)
THREE PHASE FAN CONNECTED TO
ANPHASE
ITC CONTROLLER
& OPTIONAL EXTERNAL
THREE
FAN
CONNECTED
TO ANWIRING
ITC CONTROLLER
AN AUTO
SENSOR
DIAGRAM
CONTROLLER & OPTIONAL EXTERNAL SENSOR
1 Phase Auto
Transformer
Speed Controller.

Fuse

N L1

AIRFLOW

N1 L2

Duct

Stock

Dia.

Ref. No.

Weight
Kg

200

SLPT200

760

490

235

200

205

20

250

SLPT250

865

590

285

250

233

32

315

SLPT315

955

650

350

315

240

39

X
FUSE

Visionex PIR
(45 07 26)
7 Day Time
Switch
(56 35 15)

L
N
5
4
3
OPTIONAL
EXTERNAL
SENSOR

OPTIONAL EXTERNAL SENSOR


PLEASE NOTE:
IF AN EXTERNAL SENSOR IS USED TO
CONTROL THE FAN REMOVE THE LINK
FROM S1 TO SG.

FAN 2 FAN 1
FAIL FAIL

REMOTE VISUAL
CONTROLLER
CONNECTIONS

E N L

240V
INPUT

24V AC
240V
INPUT

ITC (Stk Ref 103 14 200)


ITC-DS (Stk Ref 103 14 210)

A
INSERT LINK FOR
LED 1
24HR CHANGE OVER
K
(ITC-DS ONLY)
A
LED 2
K
FS
LK1
FG LINK
S1
SENSOR
CONNECTIONS
SG

Plan

N L1 L2 L3

FAN 2
OUTPUT

N
L1
L2
L3
TK
TK

FAN 1
OUTPUT

N
L1
L2
L3
TK
TK

8 holes 8mm
E
L
N

Fan No 2
Terminals.

Ecotronic
Humidity Sensor
(56 35 32)

E DC B A

Elevation

E
L
N

Fan No 1
Terminals.

Ambient Response
Humidity Sensor
56 35 50)

from Vent-Axia

Switched Fused Spur


L

103 14 103
103 14 105
E

1 Phase Supply
(220-240V 50Hz).

110

SINGLE PHASE FAN CONNECTED


TO AN AUTO TRANSFORMER
SPEED, WIRED
SINGLE PHASE FAN
CONNECTED
TO AN AUTO TRANSFORMER
FOR SIMULTANEOUS
RUNNING SPEED
CONTROLLER, WIRED FOR SIMULTANEOUS RUNNING
1 Phase Supply
(220-240V 50Hz).

Fan No 1
Terminals.

1 Phase Supply
(220-240V 50Hz).

Switched Fused Spur

SINGLE PHASE FAN CONNECTED


TO A D.O.L.
STARTER,
WIRED FOR
SINGLE
PHASE FAN
CONNECTED
TO A D.O.L. STARTER,
WIRED
SIMULTANEOUS
RUNNING
FOR SIMULTANEOUS RUNNING

Fuse

SINGLE PHASE FAN CONNECTED TO AN ITC CONTROLLER & OPTIONAL EXTERNAL


SENSOR/SENSORS WIRING DIAGRAM

SLPT 200
SLPT 250
SLPT 315

from Vent-Axia