Models: 2500-F2
2500-DF2
2500-AF2
9
6
ENTER
ZERO
UNITS
ZER O
MENU
MENU
PRIN T
2
0
TER
ENTE
EN
UNI TS
50190
Issue #7 11/03
Table of Contents
50190
5
9
10
11
13
14
15
16
17
Section 4: Programming
A. General Programming Instructions . . . . . . . . . . . . . . . . . . . .
B. Recommended keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Instructions apply to all menus . . . . . . . . . . . . . . . . . . . . . . .
D. Operation Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E. Modem Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F. Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G. Reports
......................................
H. 4 to 20mA SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I. Communication Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J. Devices
......................................
K. Remote Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
19
19
20
22
24
26
28
30
32
34
11/03
Issue #7
50190
Section 5: Features
A. Report Field Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B. Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Search Field Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
36
37
Section 6: Diagnostics
A. Load Cell Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
41
42
44
46
47
49
50
52
56
11/03
Issue #7
Amendment Record
Created: 9/98
Issue #1
Issue #2
Issue #3
Issue #4
9/98
Issue #5
05/02
Issue #6
07/03
Issue #7
11/03
Disclaimer
Every effort has been made to provide complete and accurate information in this manual. However, although this
manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no
representations or warranties with respect to the contents of this manual, and reserves the right to make changes to
this manual without notice when and as improvements are made.
50190
11/03
Issue #7
11/03
Issue #7
11/03
Issue #7
50190
11/03
Issue #7
11/03
Issue #7
11/03
Issue #7
50190
10
11/03
Issue #7
50190
a. If the correct password has been entered, the display will show the
appropriate menu.
11
11/03
Issue #7
50190
12
11/03
Issue #7
MENU
ENTER
ZERO
UNITS
3067
Front Panel
MENU
MENU
"
PRINT
UNITS
50190
Arrow Keys - When pressed, these keys move the cursor in the display in the
direction indicated.
Menu Key - When pressed, this key changes the display to the Operation Menu.
This key can also be used to return the display to the last menu screen
that was shown.
Zero Key - This key sets the display to the Center-of-Zero.
Print Key - When pressed, a ticket will be printed. If a tare weight is entered, a
Gross, Tare, Net ticket will be printed. If no tare weight is entered a
Gross Weight ticket will be printed.
Units Key - Changes the units of weight displayed, depending on the selection
made in the Calibration Menu.
13
11/03
Issue #7
0 through 9 Keys - Used to enter numeric data, such as tares and IDs.
Enter Key - Used to enter selections into memory during programming.
ENTER
The scale can be setup to operate in one of two modes: WEIGH ONLY, commonly
called GROSS, TARE, NET weighing and IN/OUT weighing. The operating mode is
set in the Service Menu. When the system is powered up, the display for the
Operating Mode will be shown.
B. WEIGH ONLY, Main Menu
When the operating mode is set up for WEIGH ONLY mode, the display will show:
4000 lb
GROSS
TARE
AUTO TARE
WEDNESDAY 1:18PM 1-18-95
897
14
11/03
Issue #7
12340
lb
GROSS
INBOUND
OUTBOUND
723
SCALE 2
WEDNESDAY 12:45PM 12-29-96
1. IN/OUT
a. 12340 lb GROSS
This display is the weight on the platform and the weigh mode that is active.
b. The tilde, ~,
represented to the right of the displayed Gross weight, indicates there
is motion on the platform.
c. INBOUND
This option is selected to do INBOUND weighing.
d. OUTBOUND
This option is selected to do OUTBOUND weighing.
e. 723
This number represents the number of transactions that can be stored
before the memory buffer begins to over-write itself. The maximum
number of stored transactions is 1648. If a report is printed before the
1648 number is reached, the count will reset to zero. To prevent overwriting records, print a report summary and clear the memory before
this number reaches zero.
f. SCALE 2
If more than one scale is selected, this legend will appear to show
which scale the displayed values are from.
g. Wednesday 12:45PM
This is the current day and time with the appropriate AM or PM legend.
The time is in the hour, minute format.
h. 12-29-96
This is the current date in a month, day, and year format.
Use the UP or DOWN arrow keys on the keypad to place the arrow next to
the option to be selected. Press the ENTER key on the keypad to select the
option.Press the MENU key to display the Operation Menu.
50190
15
11/03
Issue #7
The display
will show:
XXXXX
YYYYY
ZZZZZ
lb
GROSS
TARE
NET
TARE
AJUTO TARE
WEDNESDAY 1:18PM 1-18-95
50190
16
897
11/03
Issue #7
17
11/03
Issue #7
50190
18
11/03
Issue #7
Section 4: Programming
General Programming Instructions
A. The programming menus that contain all of the parameters for the system are
listed below.
1. Operation Menu - Accessible without a password by pressing the MENU
key. This menu is used for general weighing operations and accessing
further programming menus.
2. Configuration Menu - May be protected with a password. This menu is
used to set up the parameters for the Field Names, products, IDs, Titles,
display contrast, audible alarms, and outputs.
3. Service Menu - May be protected with a password. This menu is used to
set up the technical parameters of the system, such as scale capacity,
span, and load cell data.
4. Modem Service Menu - Will be protected with the same password as the
Configuration Menu. This menu is used to program and operate the modem
service feature.
B. It is recommended that a keyboard be part of the system so that data may be
entered in both alpha and numeric formats.
C. The following instructions apply to all of the menus.
1. In all menus, the UP or DOWN arrows move the cursor in the indicated
direction.
2. To make an entry, place the cursor beside the item to be selected and
press the ENTER key. Either the operator will be prompted for the data to
be entered or press ENTER to scroll through displayed choices.
3. A "key" symbol beside a menu item means the item is "locked" and can
only be accessed with a password.
4. Data may be entered through the keypad.
5. When the appropriate data has been entered, press the ENTER key to
record the data into memory.
50190
19
11/03
Issue #7
D. Operation Menu
The items in the OPERATION MENU may be set or re-set at any time through the
keypad, except those items that are "locked" by a password.
OPERATION MENU
MENU
TIME and TICKET
KEYBOARD TARE
AUTOTARE
AUDIT TRAIL
MODEM SERVICE
CONFIGURATION MENU
SERVICE MENU
Description
Enter the time in any format.
If the time was entered in the standard format,, select am or
pm, whichever is appropriate.
Enter the date in the proper numeric format.
The options are hh:mm, am/pm, or hh:mm (24 hour time).
The options are Month-dd, dd:mm, dd-Month, mm:dd.
The options are yy or yyyy.
The time and date that were entered will be converted to the format selected, The revision
number and date at the bottom of the screen are the program version number and date.
This should be noted on the test sheet for future reference.
2. Ticket Number
Enter the number to appear on the next ticket to be printed out.
NOTE: The KEYBOARD TARE and AUTOTARE operate the same in both
the OPERATION and CONFIGURATION MENUS. Data can be
entered from either one.
50190
20
11/03
Issue #7
3. Keyboard Tare
Enter the LOOP ID and then the TARE WEIGHT for the container. Once
an entry is made, it cannot be changed by the operator in the Operation
Menu.Changes can be made through the Configuration Menu.
4. Autotare
Enter the LOOP ID and the TARE WEIGHT will be entered automatically
when the container is placed on the scale.
NOTE: Stored tare data can only be retrieved in Data Terminal
(Inbound/Outbound) mode.
5. Audit Trail
To select, press the ENTER key.The display will show the Audit Trail for
calibration and configuration.
CAIBRATION
TIME
DATE
COUNT
1
2
3
4
CONFIGURATION
TIME
DATE
COUNT
1
2
3
4
This display shows the time and date when the calibration or configuration
programs were changed. The first column is the number of the platform,
followed by the time and date the change was made. The count column
shows the number of times the platform has been calibrated or configured.
This display is updated automatically with each calibration or configuration
change. It cannot be changed manually.
50190
21
11/03
Issue #7
6. Modem Service
To select, press the ENTER key. If locked, enter the CONFIGURATION
PASSWORD to enter Modem Service.
7. Configuration Menu
To select, press the ENTER key. If locked, enter the CONFIGURATION
PASSWORD to enter the Configuration Menu.
8. Service Menu
To select, press the ENTER key. If locked, enter the SERVICE
PASSWORD to enter the Service Menu.
E. Modem Service
This selection is used to operate the Modem Service link. This option requires that
Modem Accessory ACC-2020 be installed. See Bulletin 50167/SJ4642 for more
information on the Modem Operation. When this option is selected, the display will
show:
MODEM CONTROL PANEL
OPERATION MENU
INITIALIZE MODEM
BAUD SELECT (COM 2)
TELEPHONE TONE
DIAL
REDIAL
HANGUP
COM PORT ENABLED
MODEM COMMAND
NO
CARRIER OFF
1. OPERATION MENU - This selection returns the display to the
OPERATION Menu.
2. INITIALIZE MODEM - This selection sets the transmission parameters for
COM 2 to the default settings.These settings will match the parameters of
the receiving modem.
3. BAUD SELECT - This selection will display the parameters selected for
COM2 Port.For example:
50190
22
11/03
Issue #7
9600
BAUD
19200
9600
4800
2400
1200
600
300
COM PORT 2
NONE
8
PARITY
DATA
NONE
ODD
EVEN
MARK
SPACE
7
8
1
STOP
1
2
MENU
50190
23
11/03
Issue #7
F. CONFIGURATION MENU
To enter the CONFIGURATION MENU, place the cursor beside the legend and press
the ENTER key. The operator will be prompted for a PASSWORD if one has been
installed. Enter the password and press the ENTER key. The display will show:
CONFIGURATION MENU
OPERATION MENU
KEYBOARD TARE
AUTOTARE
SELECT SCALE
TITLE
FIELD NAMES
PRODUCT ID
MAIL ID
PROMPTS
REPORTS
DISPLAY CONTRAST
AUDIBLE ALARM (ON or OFF)
LOAD CELL DIAGNOSTICS
4 TO 20mA SETUP
COMMUNICATION PORTS
1. OPERATION MENU
Select this option to return to the OPERATION MENU.
2. KEYBOARD TARE
Enter the LOOP ID and then the TARE WEIGHT to be used with the entered
LOOP ID.
3. AUTOTARE
Place the container on the scale and press the ENTER key. Enter the
LOOP ID.
4. SELECT SCALE
If there are two platforms connected to the indicator, this selects the platform
that will be used as the "INBOUND SCALE" and the "OUTBOUND SCALE".
A third option can be used, "SELECT SCALE YES or NO"."YES" allows the
operator to select the scale to be used while in the Main Menu.
50190
24
11/03
Issue #7
5. TITLE
This selection is used to enter information, such as customer name and
address. There are 5 lines available with 31 characters per line.
6. FIELD NAME
This selection is used to describe the information to be put into a field. 15
characters per line, with 7 available lines, and prompt for each line. The
prompts are "GTN", "IN", "and "OUT".Each prompt can be toggled ON or
OFF. Only Field Name #1 is stored and available for reporting.
7. PRODUCT ID
Enter the code that will identify the product, letters or digits, up to 15
characters.
8. MAIL ID
Select to enter the Customer's name and address. Four lines of 31 characters
each are available for each customer.
9. PROMPTS
Enables or disables Product, Mail and Tare prompts in the GTN, Inbound or
Outbound menus. Also enables or disables prompting of LOOP ID or Inbound
or a GO message.
10. REPORTS
Select to print, review, and delete reports. See Subsection 4G, REPORTS.
11. DISPLAY CONTRAST
Select to change the contrast between the displayed letter and the
background. Use the UP and DOWN arrows to make the change.
12. AUDIBLE ALARM
With the alarm ON, the indicator will "BEEP" when a key is pressed on the
keypad.Press the ENTER key to toggle the alarm ON or OFF.
13. LOAD CELL DIAGNOSTICS
Displays a condition, "GOOD" or "BAD" for each load cell in the system.
14. 4-20 mA SETUP
Used to configure the 4 to 20 mA output. See Subsection 4 H for more
information.
50190
25
11/03
Issue #7
1. CONFIGURATION MENU This option will return the display to the CONFIGURATION MENU.
A report with fields has been included in the program. The report format can
be customized by assigning priorities to the various fields. Priorities are the
columns or locations where the data will be printed.Two different reports can
be stored and printed. The fields that can be prioritized are IN TIME, TIME
OUT, DATE, INBOUND WEIGHT, OUTBOUND WEIGHT, NET WEIGHT, AUX
TARE, AUX NET, PRODUCT ID, CONVERSION 1, CONVERSION 2, LOOP
ID, FIELD NAME 1-7, MAIL ID, TICKET NUMBER, ALT GROSS, ALT TARE,
ALT NET.
The Priority Feature and the Search Field feature are explained in detail in the
section, FEATURES.
50190
26
11/03
Issue #7
2. REPORT GENERATOR 1 When this option is selected, the display will show:
IN TIME
REPORT PRIORITY
1
>
PAGE WIDTH = 122 17 CPI
NOTE: When in the REPORT GENERATOR option, pressing the END
key on the keyboard will return the display to the Configuration Menu.
With the keypad, the operator will need to scroll through all of the
REPORT GENERATOR steps to return to the Configuration Menu.
This display shows the "IN TIME" as the field being considered. The "1" indicates
this will be the first field printed on the report. To change the priority, enter another
number at the cursor. If a "0" is entered, the field will not be printed. When the
ENTER key is pressed, the display will move to the next field. Do each field in the
same way. The page width, 122 (characters), and the 17 CPI (characters per inch)
are automatically set when the report fields are prioritized. To prevent "Wrap-ARound" in the printed report, the printer must be able to accept the page width and
CPI parameters.
3. TRANSACTION REPORT 1 - When this option is selected, the printer will
print a copy of report format 1.
4. REPORT GENERATOR 2 - This allows a second report format to be stored
in memory. Priorities are assigned the same way as in Report Generator 1.
5. TRANSACTION REPORT 2 - The option prints a report using the REPORT
2 format.
6. DELETE TRANSACTIONS - Select this option to delete all transaction
files. This is usually done after a report has been printed.
7. TARE REPORT - This option prints a report listing all of the loop ID's and
the tare weights stored in memory.
50190
27
11/03
Issue #7
50190
28
XXXX
XX.X%
XXXX
XX.X%
GROSS
1
11/03
Issue #7
50190
29
11/03
Issue #7
I. COMMUNICATION PORTS
This selection is used to configure communication ports 2, 3, 4 and 5. When this
option is selected, the display will show:
COM PORT 2
CONFIGURATION MENU
COM PORT
LOOP BACK TEST
DEVICES
DEFAULT FORMAT
INBOUND FORMAT
OUTBOUND FORMAT
GROSS*TARE*NET FORMAT
BAUD SELECTION
INVERSE PRINT
ENLARGED CHARACTERS
FORM SIZE
REMOTE DISPLAY
1.COM PORT 2 - This displays the communications port that is being
configured.
2.CONFIGURATION MENU - When this item is selected, the display returns
to the CONFIGURATION MENU.
3.COM PORT - This is used to select the communications port to be
configured, 2, 3, 4 or 5.
4. LOOPBACK TEST - When this item is selected, it will perform an internal
loopback on the selected Com Port. It will then prompt for a communications
test between any two Com Ports.
5. DEVICES - This selection is used to turn the communications port,
designated in Step 3, OFF or to select the device to be used, such as a
printer or computer. See Subsection 4 J
6. DEFAULT FORMAT - This selection sets the default print parameters and
baud selection for the device selected.
50190
30
11/03
Issue #7
NOTE: In the service program, update rates of less than .4 seconds will
cause erroneous remote display (lamp bank) performance.
50190
31
11/03
Issue #7
J. Devices
When Devices is selected from the Communications Port Menu, the screen will
show:
COM PORT 2 OFF
COMMUNICATIONS MENU
COM PORT 2 OFF
CTS RTS CONTROL
TICKET PRINTER 50-3925
TICKET PRINTER 50-3960
TICKET PRINTER 50-3950
TICKET PRINTER SP 2000
TICKET PRINTER PTR 610
TICKET PRINTER SP 2200
TAPE PRINTER 50-3715
FORM PRINTER 50-3921
FORM PRINTER OKI 320/520
CUSTOM DRIVER
COMPUTER (PC)
1. To select the device, place the cursor beside the appropriate choice and
press the ENTER key. If "COM PORT 2 OFF" is selected, the communications
port will be turned OFF. Any other choice will automatically turn the port ON.
2. If "CTS RTS CONTROL" is selected, pressing the ENTER key will toggle
the selection between YES and NO.
3. If a printer is to be selected, place the cursor beside the appropriate choice
and press the ENTER key. Configuration for the selected printer will be
automatic and the printer legend will appear at the top of the menu.
CUSTOM DRIVER
MENU
TICKET ITITIALIZATION
CHARACTER SIZE
DOUBLE WIDTH
LINE FEED
FORM FEED
REPORT INITIALIZATION
50190
32
11/03
Issue #7
Control Codes
27, 64
27, 49
27,67,35
27, 80
27, 69
27, 87, 1
10
12
27, 64
27, 50
27, 67, 66
27, 120, 1
15
Character Size
Double Width
Line Feed
Form Feed
Report Init.
Description
Reset
7/72" Line Spacing
Form Len = 35 Lines
10 CPI
Emphasized Print
Double Width Print
Line Feed
Form Feed
Reset
6 Lines per Inch
66 Lines per Page
Near Letter Quality
Compressed Print
<SETUP MENU>
CONTINUOUS
DEMAND
AUTO
COMPLETED RECORDS
CHECKSUM
POLL CHARACTER
START MESSAGE
BLOCK SEPARATOR
END OF MESSAGE
(COM2)
OFF(ON)
Cr
CrLf
EOT
33
11/03
Issue #7
K. Remote Display
If REMOTE DISPLAY is selected, the display will show:
50190
34
11/03
Issue #7
Section 5: Features
Introduction
Several features are available in the Intalogix Technology. This section explains
these features in detail.
A. REPORT FIELD PRIORITY
When a transaction record is created, there are 24 data fields created within the
record. These data fields are used when reports are printed. The operator can
select which data fields will appear in the report and the order in which they will be
printed. This is done by assigning PRIORITIES to the fields. The priority is the
number of the column in which the data will appear in the report.
The data fields created are:
1. IN TIME
2. TIME OUT
3. DATE
4. INBOUND WEIGHT
5. OUTBOUND WEIGHT
6. NET WEIGHT
7. AUX TARE WEIGHT
8. AUX NET WEIGHT
9. PRODUCT ID
10. CONVERSION 1
11. CONVERSION 2
12. LOOP ID
13. FIELD NAME 1
14. FIELD NAME 2
15. FIELD NAME 3
16. FIELD NAME 4
17. FIELD NAME 5
18. FIELD NAME 6
19. FIELD NAME 7
20. MAIL ID
21. TICKET #
22. ALT GROSS
23. ALT TARE
24. ALT NET
50190
35
11/03
Issue #7
REPORT PRIORITY
1
>
PAGE WIDTH = 122 17 CPI
The "1" is the column number that has been assigned to the data in the IN
TIME field.
The page width will vary from 0 to 131, depending on the number of fields that
have been selected to be printed in the report. This number can not be
changed manually, but will change automatically as the number of prioritized
field changes. The CPI (characters per inch) number will also change
automatically as the number of prioritized fields is changed.
3. At the cursor, enter the number of the column where this item is to appear
in the report. If a "1" is entered, this will be printed in the first column of the
report. If a "0" is entered as the column number, the data in this field WILL
NOT BE PRINTED in the report.
4. Press the ENTER key and the choice will be assigned to the field and the
display will advance to the next field. Repeat this process for each of the field
that can be placed in the report.
B. Conditions
1. If a field has a priority of "0", it will not be printed in the report.
2. If two fields are assigned the same priority, the one that occurs first in the
field list will be printed first in the report.
3. If fields 3 through 11 are assigned a priority other than "0", the operator will
be asked if the filed is to be used as a SEARCH FIELD. The SEARCH FIELD
feature is explained in the following section.
50190
36
11/03
Issue #7
REPORT PRIORITY
1
>
PAGE WIDTH = 122 17 CPI
50190
37
11/03
Issue #7
b. Advance the display to the DATE field. This is the first field that can
be used as a search field. All of the remaining fields can be used as
search fields.
NOTE: If the report priority is "0", it CAN NOT be used as a search field.
If the priority is other than "0", it can be used as the search field.
c. With a report priority other than "0" selected, press the ENTER key.
REPORT PRIORITY
The display
will show:
1
SEARCH FIELD
>
PAGE WIDTH = 122 17 CPI
38
11/03
Issue #7
c. At the end of each report generated from a search field, the "totals"
for all of the listed transactions will be printed. For example, if the
search field selected is "OUTBOUND WEIGHT" , the total outbound
weight for all entered transaction will be printed at the end of the report.
d. IN TIME and TIME OUT can not be used as search fields.
e. When a new search filed is selected, all existing search fields should
be deleted. Deleting search fields is done by placing the cursor beside
the search field and repeatedly pressing the right arrow on the key pad
or pressing the "delete" key on the keyboard.
4. SUMMARY OF SEARCH FIELDS
SEARCH FIELD
=(+ or >)
-(= or <)
Date
yes
yes
Inbound weight
yes
yes
Outbound Weight
yes
yes
Net Weight
yes
yes
* (all)
yes
CONVERSION 1
CONVERSION 2
LOOP ID
yes
FIELD NAME 1
FIELD NAME 2
FIELD NAME 3
FIELD NAME 4
FIELD NAME 5
FIELD NAME 6
FIELD NAME 7
MAIL ID
yes
Ticket Number
yes
yes
Alt GROSS
yes
yes
Alt TARE
yes
yes
Alt NET
yes
yes
50190
39
11/03
Issue #7
Section 6: Diagnostics
A. Load Cell Failure
One of the following messages may appear in the display.
LOAD CELL
FAILURES(S)
This message is triggered by one of several conditions. If it appears, call your local
Service Center.
When the ZERO key is pressed, the following message may appear:
LOAD CELL(S) BAD
CHECK THAT SCALE IS EMPTY
IF SCALE IS EMPTY
CALL for SERVICE
Operate the ZERO key
TO CONTINUE.
This message indicates that something has happened to the scale and the weight
being seen by the indicator is outside the allowed zero reference. If it appears, call
your local Service Center.
B. High water in scale X:
X = Scale number
This message indicates water is in scale X pit. The pit needs to be cleaned
out.
C. Please wait, communicating with computer
This message will appear on the main weigh screen if the indicator is being
accessed via a remote computer to upload a transaction file or a configuration
file, etc. This does not indicate any sort of error. This message will remain
until the upload of data is complete. The indicator will then return to the
normal weighing mode.
50190
40
11/03
Issue #7
Printer
50-3925
50-3960
50-3950
SP 2000
PTR 610
SP 2200
50-3715
50-3921
OKI 320/520
IDS 152
590
295
50190
IND-R2500-F1
13464
14807
13464
14807
13464
14807
14809
14807
14807
13464
14807
14807
41
IND-HR2500-F1
16084
16157
16084
16157
16084
16157
12654
16157
16157
16084
16157
16157
11/03
Issue #7
5
9
6
2450a
Pin 1 - TX (-20mA)
Pin 1 - NC
Pin 2 - NC
Pin 2 - RX ( INPUT)
Pin 2 - RX (INPUT)
Pin 3 - NC
Pin 3 - TX (OUTPUT)
Pin 3 - TX (OUTPUT)
Pin 4 - NC
Pin 4 - NC
Pin 5 - FRAME/GND
Pin 5 - FRAME/GND
Pin 5 - FRAME/GND
Pin 6 - NC
Pin 6 - NC
Pin 7 - NC
Pin 8 - NC
Pin 9 - TX (+20mA)
Pin 9 - RI (INPUT)
Pin 9 - NC
COM 2 or 3
IDS 152
590 / 295
Pin 2 - RX
Pin 2
Pin 3 TX
Pin 3
Pin 3
Pin 3
Pin 5 Ground
Pin 7
Pin 7
Pin 7
Pin 8 - CTS
Pin 20
Pin 4
Cable #1254
Part # 14809
Part # 13464
Part # 14807
50190
42
11/03
Issue #7
Remote Display
1405 Terminal
1
2
At the remote display terminal connect black to terminal 2 and connect red to terminal 1.
Depending on the weight display required refer to 1405 Manual to set S1 switches.
2. Fairbanks Model 1415 Remote Display
Order Accessory Kit No.334 - Part No. 13486
Instrument, DIS
DBP Connector
Tx - Pin 1
Tx + Pin 9
Remote Display
1415 Terminal
2
3
Remote Display
Display Terminal
(+15VDC) Pin 1
(C Loop) Pin 5
(C Loop) Pin 6
(GND) Pin 2
50190
43
11/03
Issue #7
9-Pin Connector
P3 on the
Mother Board
2433
COM2
COM3
and COM4
and COM5
Pin 1 - (+)
Pin 1 - NC
Pin 2 - (-)
Pin 2 - NC
Pin 3 - GND
Pin 3 - GND
Pin 4 - NC
Pin 4 - TX (OUTPUT)
Pin 4 - TX (OUTPUT)
Pin 5 - NC
Pin 5 - RX (INPUT)
Pin 5 - RX (INPUT)
Pin 6 - NC
Pin 7 - NC
Pin 8 - NC
Pin 8 - FRAME/GND
Pin 9 - NC
Pin 9 - RI (INPUT)
Pin 9 - NC
Pin 5 - RX
Pin 2
Pin 4 - TX
Pin 3
Pin 3
Pin 3
Pin 8 - Ground
Pin 7
Pin 7
Pin 7
Pin 7 - CTS
Pin 20
Pin 4
Cable #1265
Part # 12654
Part # 16084
Part # 16157
50190
44
11/03
Issue #7
Remote Display
1405 Terminal
1
2
At the remote display terminal connect black to terminal 2 and connect red to terminal 1.
Depending on the weight display required refer to 1405 Manual to set S1 switches.
2. Fairbanks Model 1415 Remote Display
Order Accessory Kit No. 1266 - Part No. 15885
Instrument, DIS
Round 9-Pin Connector
Tx - Pin 2
Tx + Pin 1
Remote Display
1415 Terminal
2
3
Remote Display
Display Terminal
(+15VDC) Pin 1
(C Loop) Pin 5
(C Loop) Pin 6
(GND) Pin 2
50190
45
11/03
Issue #7
OFF(ON)
Cr
CrLf
EOT
<SETUP>
This selection will return to the DEVICES MENU subsection 4J
CONTINUOUS
Selects continuous computer output mode. The demand output is transmitted when
the 2500 series instrument receives the proper Poll Character ion ASCII format from
the receiving computer. The default Poll Character is a carriage return (decimal 13).
DEMAND
Selects Demand Output mode. The Demand output is transmitted when the 2500
Series instrument receives the proper Poll Character in ASCII format from receiving
computer. The default Poll Character is a Carriage Return (Decimal 13).
Selecting Computer Demand will enable the indicator to receive either a
remote Print command or a remote Zero command from the computer. If the
indicator receives a P from the computer it will initiate a print cycle. Likewise
a Z will perform a Zero function.
AUTO
Selects Auto computer output mode. The Auto output is transmitted when an
Inbound, Outbound or GTN ticket is printed.
CHECKSUM
This selection toggles on and off by pressing ENTER when selected. It will determine
whether a Checksum character is sent at the end of the computer output.
POLL CHARACTER
The Poll Character is the character that will, when received, cause the 2500 series
indicator to transmit the output string when in the demand mode. If changed from a
Cr (carriage return) use the decimal equivalent of the ASCII character required.
50190
46
11/03
Issue #7
START MESSAGE
This is the first character transmitted in the output string. Enter the decimal
equivalent of the ASCII character desired. This is for demand or auto modes.
BLOCK SEPARATOR
This is the character(s) that separates each string of data formatted to send in the
demand or auto modes. Enter the decimal equivalent of the ASCII character.
END OF MESSAGE
This is the character that will signal that the transmitted data is complete. The default
is EOT (decimal 04). The decimal equivalent of the ASCII character should be
entered.
NOTE: The second line of the highlighted area at the top pf the display
shows the current Output mode selected; CONTINUOUS, DEMAND OR
AUTO.
A. Continuous Output Mode
The Continuous Computer Output is uniniated, unrequested output that gets
transmitted at a fixed time interval.
Character String
STX
A
B
C
xxxxxx
xxxxxx
CR
CS
50190
Description
Start of text character : (02 Hex)
Status Word A
Status Word B
Status Word C
Displayed Weight : x = Weight
(6 characters if the graduation size does not have a decimal point.)
(5 characters if the graduation size does have a decimal point.)
The decimal point is not sent as part of the character string.
Tare Value : x = Tare
(6 characters if the graduation size does not have a decimal point.)
(5 characters if the graduation size does have a decimal point.)
The decimal point is not sent as part of the character string
Carriage Return Character : (OD hex)
CheckSum Character : If enabled, this character consists of the last
eight bits of the binary sum of all characters transmitted up to this
checksum character.
47
11/03
Issue #7
Status Word A
Decimal Point or Zero Location
Bit #
x00
0
0
0
0
1
2
Count by 1
1
0
3
4
5
6
7
50190
x0
1
0
0
x
0
1
0
x.x
1
1
0
Increment Size
Count by 2
0
1
Always Logic 1
Always Logic 0
Parity Bit
Bit #
0
1
2
3
4
5
6
7
Status Word B
Description
Gross = 0
Positive = 0
In Range = 0
No Motion = 0
lb = 0
Always Logic1
Normal = 0
Parity Bit
Bit #
0
1
2
3
4
5
6
7
Status Word C
Description
Always Logic 0
Always Logic 0
Always Logic 0
Normal = 0
Always Logic 0
Always Logic 1
Normal = 0
Parity Bit
48
x.xx
0
0
1
x.xxx
1
0
1
x.xxxx
0
1
1
x.xxxxx
1
1
1
Count by 5
1
1
Net = 1
Negative = 1
Overcapacity = 1
Motion =1
kg = 1
Power Up = 1
Keyboard Tare = 1
11/03
Issue #7
B. Demand Output : When the Poll character is received on Com 2 through Com 5 of the IND-R2500, it will
output information based on the FROM TOP and FROM RIGHT coordinates in the GROSS*TARE*NET Ticket
Formats menu selections. All character strings that have a non-zero value in either of the coordinates will be
transmitted. The order that the character strings appear in the data transmission follows the numbering
sequence of the FROM TOP and FROM RIGHT coordinates. An example follows this output description.
Menu
Character String
Description
xxxxxxx_yy_GR<~>CR<~>LF
:Gross Weight (with legend)
(x =<~>Weight, y = Units :fixed length, 10 characters)
(_GR = Legend :fixed length, 3 characters)
or
xxxxxxx_yy CR LF
:Gross Weight (no legend)
(x = Weight, y = Units : fixed length, 10 characters)
xxxxxxx_yy_TA CR L
: Tare Weight (with legend)
(x = Weight, y = Units :fixed length, 10 characters)
(The space between Weight and Units will be a * if keyboard Tare)
(_TA = Legend : fixed length, 3 characters)
or
xxxxxxx_yy CR LF
:Tare Weight (no legend)
(x = Weight y = Units : fixed length 10 characters)
(The space between Weight and Units will be a * if keyboard Tare)
xxxxxxx_yy_NT CR LF
:Net Weight (with legend)
(x = Weight, y = Units :fixed length, 10 characters)
(_NT = Legend : fixed length, 3 characters)
or
xxxxxxx_yy CR LF
:Net Weight (no legend)
(x = Weight, y = Units :fixed length 10 characters)
xx:xxyy CR LF
:Time
(x = Time y = am pm:fixed length, 7 characters)
xx-xx-xx CR LF
: Date
(x = Date : fixed length, 8 characters)
TICKET_NUMBER_xxxxxxxx CR LF
: Ticket Number
(TICKET_NUMBER_ = Legend : fixed length, 14 characters)
(x = Ticket Number Value : variable length, 8 characters max)
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CR LF
: Title Line 1
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CR LF
: Title Line 2
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CR LF
: Title Line 3
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CR LF
: Title Line 4
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx CR LF
: Title Line 5
(x = Title Line Text : variable length, 30 characters max)
Prompt
:GROSS
:GROSS
:TARE
:TARE
:NET
:NET
:TIME
: DATE
:CON#
: TITLE1
: TITLE2
: TITLE3
: TITLE4
: TITLE5
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 1
: fNAME1
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 2
: fNAME2
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 3
: fNAME3
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 4
: fNAME4
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 5
: fNAME5
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 6
: fNAME6
xxxxxxxxxxxxxxx_yyyyyyyyyyyyyyy CR LF
: Field Name 7
: fNAME7
(x = Field Name Title<~>:<~>variable length 15 characters max)
(_ = Space Character)
(y = Field Name Entry : variable length 15 characters max)
SCALE_ID_xx CR LF
(SCALE_ID_ = Legend : fixed length, 9 characters)
(x = Scale Identifier : fixed length, 2 characters)
:Scale ID
:SC ID
EOT
End of Transmission Character : (04 hex)
CS
CheckSum Character : If enabled this character consists of the last eight bits of the binary sum of all
characters transmitted up to this checksum character
50190
49
11/03
Issue #7
C. Auto Output : When a Gross Tare Net print is done, or an Inbound Weighment is completed, or an Outbound
Weighment is completed, the IND-R2500 will output information based on the FROM TOP and FROM RIGHT
coordinates in the GROSS*TARE*NET, INBOUND, and OUTBOUND Ticket Formats respectively. All character
strings that have a non-zero value in either of the coordinates will be transmitted. The order that the character
strings appear in the data transmission follows the numbering sequence of the FROM TOP and FROM RIGHT
coordinates. An example follows this output description. The details and options on the Gross Tare Net print are
the same as the IND-R2500 Format - Demand Output. See Subsection B. Demand Output for details.
INBOUND and OUTBOUND Formats
Character String
xxxxxxx_yy_GR CR LF
(x = Weight y = Units : fixed length 10 characters)
(_GR = Legend : fixed length 3 characters)
or
xxxxxxx_yy CR LF
(x = Weight y = Units : fixed length 10 characters)
xxxxxxx_yy_TA CR LF
(x = Weight y = Units : fixed length 10 characters)
(_TA = Legend : fixed length 3 characters)
or
xxxxxxx_yy CR LF
(x = Weight y = Units : fixed length 10 characters)
xxxxxxx_yy_NT CR LF
(x = Weight y = Units : fixed length 10 characters)
(_NT = Legend : fixed length 3 characters)
or,
xxxxxxx_yy CR LF
(x = Weight y = Units : fixed length 10 characters)
INBOUND_xxxxxxx_yy CR LF
(INBOUND_ = Legend : fixed length 8 characters)
(x = Weight y = Units : fixed length 10 characters)
or
xxxxxxx_yy CR LF
(x = Weight y = Units : fixed length 10 characters)
LOOP_ID_xxxxxxxxxxxxxxx CR LF
(LOOP_ID_ = Legend : fixed length 9 characters)
(x = Tare ID Value : variable length 15 characters max)
xx:xxyy CR LF
(x = Time y = am pm : fixed length 7 characters)
xx-xx-xx CR LF
(x = Date fixed length 8 characters)
TIME_IN_xx:xxyy CR LF
(TIME_IN_ = Legend : fixed length 8 characters)
(x = Time,, y = am pm : fixed length 7 characters)
TICKET_NUMBER_xxxxxxxx CR LF
(TICKET_NUMBER_ = Legend : fixed length 14 characters)
(x = Ticket Number Value : variable length 8 characters max)
xxxxxxxxxxxxxxx__yyyyyyyyyyyyyyy CR LF
(x = Header Title : variable length 15 characters max)
(__ = 2 Space Characters)
(y = Header Value : variable length15 characters max)
xxxxxxxxxxxxxxx_TOTAL_yyyyyyy_zz CR LF
50190
50
Description
: Gross Weight (with legend)
Menu
Prompt
: GROSS
: GROSS
: TARE
: TARE
: NET
:NET
: WT. IN
: Loop ID
: LOOP ID
: Time
:TIME
: Date
: DATE
: Inbound Time
:TM IN
: Ticket Number
: CON#
HEADER
: Header Total
:TOTAL
11/03
Issue #7
Each of the above character strings can be disabled from transmission. To disable a character string
(or strings), place 0.0 in both the FROM TOP and FROM RIGHT coordinates in the INBOUND and /
or OUTBOUND Ticket Formats menu selections.
50190
51
11/03
Issue #7
D. COMPLETED RECORD (COM 2) - This Output is available only on Com 2 The completed Record output is transmitted upon completion of an incomplete or
stored tare transaction. Data is in ASCII, comma delimited format. Data is sent in the
following order:
1. Product ID
2. Customer ID
3. Loop ID4. Time IN
5. Time Out
6. Date
7. Net Weight
8. Units
9. Inbound Weight
10. Units
11. Outbound Weight
12. Units
13. Aux Net
14. Units
15. Aux Tare
16. Units
17. Fieldname 1
18. Fieldname 2
19. Fieldname 3
20. Fieldname 4
21. Fieldname 5
22. Fieldname 6
23. Fieldname 7
24. Ticket #
Example of actual data:
Y"","","57"," 7:35AM"," 7:36AM","3/18/98",
00,"lb",
00,"lb",
00,"lb", 00,"lb",
00,"lb", "COMPLETE REPORT","COM2 OUTPUT","OUTPUT NOW!","","", "","",0,,,,,
50190
52
11/03
Issue #7
0.0
0.2,
0.3,
0.8,
0.7,
0.6,
0.5,
0.9,
0.4,
1.0,
0.0,
0.8,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
53
LEGEND = YES
LEGEND = YES
LEGEND = YES
(GROSS)
(TARE)
(NET)
(CON#)
(DATE)
(TIME)
(LOOP ID)
(WT. IN)
(TM IN)
(HEADER)
11/03
Issue #7
INBOUND
The following is an updated list of fields available available for output in the Inbound
ticket format.
Menu Prompt
GROSS
TARE
NET
WT. IN
LOOP ID
TIME
DATE
TM IN
CON#
HEADER
TOTAL
TITLE1
TITLE2
TITLE3
TITLE4
TITLE5
fNAME1
fNAME2
fNAME3
fNAME4
fNAME5
fNAME6
fNAME7
SC ID
Description
Gross Wt
Tare Wt
Net Wt
Inbound Wt
Tare ID
Time
Date
Time In
Ticket Nbr
Header
Total for Header
Title Line 1
Title Line 2
Title Line 3
Title Line 4
Title Line 5
field Name 1
field Name 2
field Name 3
field Name 4
field Name 5
field Name 6
field Name 7
Scale ID
The <MORE> menu selection is no longer used to display more output selections.
Use the Up and Down arrow keys to move around and the display will adjust
automatically.
50190
54
11/03
Issue #7
OUTBOUND
The following is an updated list of fields available available for output in the
Outbound ticket format.
Menu Prompt
GROSS
TARE
NET
WT. IN
LOOP ID
TIME
DATE
TM IN
CON#
HEADER
TOTAL
TITLE1
TITLE2
TITLE3
TITLE4
TITLE5
fNAME1
fNAME2
fNAME3
fNAME4
fNAME5
fNAME6
fNAME7
SC ID
50190
Description
Gross Wt
Tare Wt
Net Wt
Inbound Wt
Tare ID
Time
Date
Time In
Ticket Nbr
Header
Total for Header
Title Line 1
Title Line 2
Title Line 3
Title Line 4
Title Line 5
field Name 1
field Name 2
field Name 3
field Name 4
field Name 5
field Name 6
field Name 7
Scale ID
55
11/03
Issue #7
COM PORT X
<CONFIGURATION MENU>
COM PORT
LOOP BACK TEST
PRINTERS
OTHER DEVICES
DEFAULT FORMAT
INBOUND FORMAT
OUTBOUND FORMAT
GROSS * TARE * NET FORMAT
BAUD SELECTION
INVERSE PRINT
ENLARGED CHARACTERS
FORM SIZE
REMOTE DISPLAY
OTHER DEVICES
Selects the COMPUTER (PC) menu as seen below.
COMPUTER (PC)
<COMMUNICATION MENU>
COM PORT X OFF
NO
CTS RTS CONTROL
NO
CUSTOM DRIVER
COMPUTER (PC)
<COMMUNICATIONS MENU>
This selection will return to the COM PORT X menu.
COM PORT X OFF
This selection turns com port off
50190
56
11/03
Issue #7
(COM 3)
(COM 4)
<SETUP MENU>
This selection will return to the COMPUTER (PC) menu.
COMPLETED RECORDS
(Available only from com port 2) This selection will cause the completed
record to be transmitted upon completion of an incomplete or stored tare
transaction. Data is in ASCII, comma delimited format. Data is sent as
shown in subsection D of this appendix.
PC OUTPUT FORMAT (COM 3)
This selection allows entry into the STREAM FORMATS menu as shown
below.
50190
57
07/03
Issue #6
STREAM FORMATS
PC SETUP MENU
MODE
CONTINUOUS
CARDINAL 738
CONDEC
FAIRBANKS / TOLEDO
WEIGH-TRONIX WI-120
EDIT/CUSTOM FORMAT
COM 3
CHECKSUM
NO
WEIGHT FORMAT
TOKENS
POLL CHARACTER
BLOCK SEPERATOR
STATUS BYTE A
STATUS BYTE B
STATUS BYTE C
PC SETUP MENU
This selection will return you to the COMPUTER OUTPUT menu.
MODE
Pressing the enter key will toggle through the following selections:
1. CONTINUOUS - Data is transmitted all the time, see section A
of this appendix for details.
2. AUTO - Data is transmitted when an Inbound, Outbound, or
GTN ticket is printed, see section C of this appendix for details.
3. DEMAND - Data is transmitted when the 2500 instrument
receives the proper Poll Character in ASCII format from the
receiving computer. The default Poll Character is a carriage return
50190
58
11/03
Issue #7
(decimal 13). Selecting the DEMAND mode will also enable the
indicator to receive either a remote Print or Zero command from
the computer. If the indicator receives a capital P it will initiate a
PRINT cycle, like wise if the indicator receives a capital Z it will
perform a ZERO function. See section B of this appendix for
details.
CARDINAL 738
This selection will cause the indicator to output the standard data string
of the Cardinal 738 instrument.
CONDEC
This selection will cause the indicator to output the standard data string
of the Condec instrument.
FAIRBANKS / TOLEDO
This selection will cause the indicator to output the standard data string
for the Fairbanks or Toledo instruments.
WEIGH-TRONIX W1-120
This selection will cause the indicator to output the standard data string
of the Weigh-tronix WI-120 instrument.
EDIT/CUSTOM FORMAT
COM X
This selection will allow access to the EDIT/CUSTOM FORMAT menu as
detailed in section E of this appendix. See example in section H of this
appendix
CHECKSUM
Pressing enter at this item will cause a toggle from ON to OFF. It
controls whether a checksum character is sent at the end of the
computer output.
50190
59
07/03
Issue #6
WEIGHT FORMAT
This selection will allow access to the WEIGHT TOKENS menu as
detailed in section F of this appendix.
TOKENS
This selection will allow access to the STREAM TOKENS menu as
detailed in section G of this appendix.
POLL CHARACTER
Pressing the enter key at this item will allow you to toggle through
several default values for the polling character, or you may also type in
the decimal equivalent.
1.
2.
3.
4.
5.
CR
^@
SPACE
STX
ENQ
BLOCK SEPARATOR
Pressing the enter key at this item will allow you to toggle through
several default values for the data block separator , or you may also type
in the decimal equivalent.
1. SPACE
2. CR
3. LF
4. CRLF
5. Blank
6. NONE
WARNING!
Modification of Status Byte A, B, or C should only be done at the
direction of Technical Services or Engineering.
50190
60
11/03
Issue #7
STATUS BYTE A
Selecting this item will allow entry into the BIT FIELDS menu for status
byte A.
STATUS BYTE B
Selecting this item will allow entry into the BIT FIELDS menu for status
byte B.
STATUS BYTE C
Selecting this item will allow entry into the BIT FIELDS menu for status
byte C.
Section E
EDIT/CUSTOM FORMAT
RETURN
UNITS TOKEN
MODE TOKEN Gr/Nt
SCALE STATUS
STATUS BYTE A
STATUE BYTE B
STATUS BYTE C
GROSS WEIGHT
TARE WEIGHT
NET WEIGHT
DISPLAYED WEIGHT
ASCII STRING
START CHARACTER
END CHARACTER
(U)
(M)
(S)
(A)
(B)
(C)
(G)
(T)
(N)
(W)
[ ]
NONE
NONE
(A)(B)(C)(W)(T)
^
50190
61
07/03
Issue #6
RETURN
This selection will return you to the STREAM FORMATS menu.
NOTE: The selections below will be reflected as an entry in the data
string as seen at the bottom of the instrument display. The highlighted
section with the ^ under the leading digit is the place where the selected
data bit will be inserted. By use of the < and > arrow keys the highlighted
area can be moved to the needed location in the data string.
UNITS TOKEN
Allows the entry of a units token such as lb or kg in the data string. Note
this only works for lb, kg, or lb/kg.
MODE TOKEN Gr/Nt
Allows the entry of a mode token such as GR or NT in the data string.
Note this only works for GR or NT.
SCALE STATUS
Allows the entry of a motion bit as shown by a capital M in the data
string at the point of insertion.
WARNING!
Modification of Status Byte A, B, or C should only be done at the
direction of Technical Services or Engineering.
STATUS BYTE'S A, B, C
Allows for the entry of grouped conditional states. These status bytes
should only be changed or modified with the assistance of Technical
Services.
GROSS WEIGHT
Allows the selection of just the gross weight. Note that lbGR will be
transmitted after the weight regardless of that weight unit or legend is
displayed at the instrument.
50190
62
11/03
Issue #7
TARE WEIGHT
Allows the selection of just the tare weight. Note that lbGR will be
transmitted after the weight regardless of that weight unit or legend is
displayed at the instrument.
NET WEIGHT
Allows the selection of just the net weight. Note that lbGR will be
transmitted after the weight regardless of that weight unit or legend is
displayed at the instrument.
DISPLAYED WEIGHT
Allows the transmission of the gross or net weight depending on which is
displayed at the instrument. Note that no units or weight legends are
transmitted.
ASCII STRING
Allows the entry of an ASCII text string into the data stream.
START CHARACTER
Inserts the start character if required, or can be removed by selecting
none.
END CHARACTER
Inserts the end character if required, or can be removed by selecting
none.
50190
63
07/03
Issue #6
Section F
WEIGHT FORMAT
WEIGHT TOKENS
RETURN
WEIGHT DIGITS
LEADING ZEROS
POLARITY INCLUSION
DECIMAL POINT
FIXED DECIMAL PLACES
JUSTIFICATION
TEST WEIGHTS
+000000
6
YES
YES
NONE
0
RIGHT
RETURN
This selection will return you to the STREAM FORMATS menu.
WEIGHT DIGITS
Allows the selection of either 5, 6, or 7 characters of displayed weight in
the data string/
LEADING ZEROS
Pressing the enter key at this selection item will cause a YES or NO
toggle to allow for leading zero's in the data string to be included or
excluded in the data string.
POLARITY INCLUSION
Pressing the enter key at this selection item will cause a YES or NO
toggle to allow for inclusion of a polarity bit at the beginning of the data
string.
50190
64
11/03
Issue #7
DECIMAL POINT
This selection allows for the placement of a decimal point. Pressing
enter will toggle throughout the following selections:
1. NONE
2. Floating
3. Fixed
4. Trailing
FIXED DECIMAL PLACES
This selection allows for the placement of a fixed decimal places.
Pressing enter will allow the keyed entry of the required number of
places.
JUSTIFICATION
Pressing the enter key at this selection will toggle from the weight data
justification from RIGHT to LEFT as seen in the transmitted data string
with reference to any leading or trailing zero's.
TEST WEIGHTS
Allows the keyed in entry of a weight value as seen at the bottom of the
instrument display for comparison purposes.
+000000
The weight as entered from the above menu item, used for comparison
purposes.
50190
65
07/03
Issue #6
Section G
TOKENS
STREAM TOKENS
RETURN
POS. POLARITY
NEG. POLARITY
PRIMARY UNITS
SECONDARY UNITS
MOTION
OUT OF RANGE
GROSS
TARE
NET
OK
INVALID
+
lb
kg
M
O
GR
TA
NT
I
RETURN
This selection will return you to the STREAM FORMATS menu.
NOTE: The following below items allow for the customization of a
selected stream item.
POS. POLARITY
Pressing the enter key here will cause a toggle between the following
selections:
1. +
2. None
3. Space
50190
66
11/03
Issue #7
NEG. POLARITY
Pressing the enter key here will cause a toggle between the following
selections:
1. 2. None
3. Space
PRIMARY UNITS
This selection allows for the ability to have a keyed entry for this field.
SECONDARY UNITS
This selection allows for the ability to have a keyed entry for this field.
MOTION
This selection allows for the ability to have a keyed entry for this field.
OUT OF RANGE
This selection allows for the ability to have a keyed entry for this field.
GROSS
This selection allows for the ability to have a keyed entry for this field.
TARE
This selection allows for the ability to have a keyed entry for this field.
NET
This selection allows for the ability to have a keyed entry for this field.
OK
This selection allows for the ability to have a keyed entry for this field.
50190
67
07/03
Issue #6
INVALID
This selection allows for the ability to have a keyed entry for this field.
Section H
EXAMPLE
To create a simple data string that consists <start of text><displayed
weight><end of text>, you would perform the following steps.
1. From the weigh screen press the MENU key.
2. Move the arrow to CONFIGURATION MENU and press the enter key.
3. Move the arrow to COMMUNICATION PORT and press the enter key.
4. Move the arrow to OTHER DEVICES and press the enter key.
5. Move the arrow to COMPUTER (PC) and press the enter key.
6. Move the arrow to PC OUTPUT FORMAT (COM 3 or 4) and press
the enter key.
7. Move the arrow to EDIT/CUSTOM FORMAT (COM 3 or 4) and press
the enter key.
8. Move the arrow to START CHARACTER and by repeatedly pressing
the enter key toggle
selections to STX.
9. Move the arrow to END CHARACTER and by repeatedly pressing the
enter key toggle selections to ETX.
10. Move the arrow to DISPLAYED WEIGHT and press the enter key.
50190
68
11/03
Issue #7
Note that the data string seen at the bottom of the instrument display
now looks like this (W)^ .
11. Exit to the weigh screen by pressing the MENU key several times.
Note that when the scale output is viewed from hypertrm in windows it
now looks like this +030280
50190
69
07/03
Issue #6