Anda di halaman 1dari 3

BCF Technology small animal exposure chart for Direct Digital

Radiography systems (DR) Thorax and Abdomen


Suggested exposures are for a Focal Spot/Film Distance (FFD) of 100cm
without a grid

Thorax VD/DV view

Thorax lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

60

1.5

60

1.5

60

1.5

60

12

70

12

70

2.5

15

70

15

70

2.5

18

75

18

75

2.5

21

80

21

80

2.5

23

80

23

80

4.5

80

25

Abdomen lateral view


Suggested
kV

Suggested
mAs

Cat/Small Dog (<15kg)

80

6.5

Abdomen VD/DV view


Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

Cat/Small Dog (<15kg)

50

2.5

50

50

50

3.5

10

55

3.5

10

55

12

60

12

60

4.5

14

65

14

65

5.5

16

70

16

70

6.5

Medium Dog (15-25kg)

Medium Dog (15-25kg)

18

75

18

70

7.5

20

80

20

80

7.5

22

80

22

80

8.5

Large Dog (>25kg)


80

Adjusted
mAs

Large Dog (>25kg)

Large Dog (>25kg)

24

Adjusted
kV

Medium Dog (15-25kg)

Medium Dog (15-25kg)

Thickness
(cm)

Adjusted
mAs

Cat/Small Dog (<15kg)

Cat/Small Dog (<15kg)

25

Adjusted
kV

Large Dog (>25kg)


10-15

24

80

10-15

Your ultrasound and X-ray people


+44 (0)1506 460 023 | training@bcftechnology.com | facebook.com/bcftechnology | www.bcftechnology.com

BCF Technology small animal exposure chart for Direct Digital


Radiography systems (DR) Pelvis/Hips, Extremities and Skull
Suggested exposures are for a Focal Spot/Film Distance (FFD) of 100cm
without a grid

Pelvis/Hips VD view

Pelvis/Hips lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

55

55

2.5

10

55

2.5

10

55

12

55

12

55

3.5

14

60

14

60

4.5

16

60

16

60

4.5

Medium Dog (15-25kg)

Medium Dog (15-25kg)


18

60

18

60

5.5

20

70

20

70

6.5

Large Dog (>25kg)

Large Dog (>25kg)


70

22

Extremities lateral and CC/DP views


Thickness
(cm)

Adjusted
mAs

Cat/Small Dog (<15kg)

Cat/Small Dog (<15kg)

22

Adjusted
kV

Suggested
kV

Suggested
mAs

Cat/Small Dog (<15kg)

Adjusted
kV

Adjusted
mAs

70

7.5

Skull lateral and DV/VD views


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Cat/Small Dog (<15kg)

50

1.5

50

1.5

50

1.5

10

60

2.5

50

1.5

12

75

50

60

2.5

Medium Dog (15-25kg)


6

60

60

3.5

Medium Dog (15-25kg)


14

75

16

80

Large Dog (>25kg)


18

80

Large Dog (>25kg)g


10

60

3.5

12

65

14

65

Your ultrasound and X-ray people


+44 (0)1506 460 023 | training@bcftechnology.com | facebook.com/bcftechnology | www.bcftechnology.com

BCF Technology small animal exposure chart for Direct Digital


Radiography systems (DR) Spine
Suggested exposures are for a Focal Spot/Film Distance (FFD) of 100cm
without a grid

Thoracic Spine VD view

Thoracic Spine lateral view


Thickness
(cm)

Suggested
kV

Suggested
mAs

Adjusted
kV

Adjusted
mAs

Thickness
(cm)

Suggested
kV

Suggested
mAs

55

3.5

55

60

60

4.5

12

65

12

65

5.5

15

75

15

75

6.5

Medium Dog (15-25kg)

Medium Dog (15-25kg)


18

80

7.5

18

80

21

80

7.5

21

80

23

80

8.5

23

80

Large Dog (>25kg)

Large Dog (>25kg)


80

25

9-10

Cervical Spine lateral and VD views


Thickness
(cm)

Suggested
kV

Suggested
mAs

Cat/Small Dog (<15kg)

Adjusted
kV

Adjusted
mAs

80

9-10

Lumbar Spine lateral and VD views


Thickness
(cm)

Suggested
kV

Suggested
mAs

50

2.5

50

55

3.5

50

3.5

12

60

10

55

3.5

15

70

12

60

4.5

14

65

5.5

16

70

Medium Dog (15-25kg)


18

75

21

80

23

80

7.5

Large Dog (>25kg)


80

Adjusted
kV

Adjusted
mAs

Cat/Small Dog (<15kg)

25

Adjusted
mAs

Cat/Small Dog (<15kg)

Cat/Small Dog (<15kg)

25

Adjusted
kV

8-10

Medium Dog (15-25kg)


18

75

7.5

20

80

7.5

22

80

8.5

Large Dog (>25kg)


24

80

9-10

Your ultrasound and X-ray people


+44 (0)1506 460 023 | training@bcftechnology.com | facebook.com/bcftechnology | www.bcftechnology.com