Anda di halaman 1dari 2

Demeo

HYDRALIC DESIGN OF SLAB CULVERT


Chainage:

0+500

Span:

1.000

Design Data :
1

Catchment Area (M)

xxx Hac.

CH

G.L.

H.F.L.

DEPTH
BELOW
H.F.L.

98.589
98.589
98.589
98.589
98.589

-0.001
0.469
1.039
0.120
0.004

0+499
0+500
0+500
0+501
0+502

98.590
98.120
97.550
98.469
98.585

xxx Sq.Km

MEAN
DEPTH

LENGTH

AREA

0.234
0.754
0.580
0.062

1.000
0.500
0.500
1.000

0.234
0.377
0.290
0.062

TOTAL=
2
3
4
5
6
7
8

Nalla Bed Level


Bed Slope (S)
H.F.L.
Wetted Area (A)
Wetted Perimeter (P)
Width of Stream at H.F.L.
Region

=
=
=
=
=
=
=

97.550
1 : 200
98.589
0.963
3.916
3.000
Flat Area

DIFT(n)OF
DEPTH
BELOW
H.F.L.
PERIMETER
8

-0.470
-0.570
0.919
0.116

0.963

1.105
0.758
1.046
1.007

3.916

M
=
M
Sq.M
M
M

0.005

Determination of Flood Velocity (V) :


V
Where :

1/n x ( R)2/3 x (S)1/2


n
=
Mannings Constant taken as
R
=
Hydralic Mean Radious (A/P)

0.926 M/Sec

Q
Q

=
=

Ax V
0.891 Cumec

=
=

0.03
0.246 M

So;

Determination of Descharge (Q) :

Determination of Linear Water Way (L1) :


L1
Where :

=
C

L1

C x Q1/2
=

4.8 for Regime Channel (as per IRC-5)

So;
4.532 M

Determination of Afflux :

Afflux =

V2

L2

Where :

L
L1
c
Afflux

Width of steam at HFL

=
=
=

Linear waterway under the bridge


Coefficient of discharge through the bridge taken as 0.7 for sharp entry
-0.005 M

Taken Value of Afflux

Determination of Culvert Openings :


Area of opening Required
=
Height of Waterway (HFL - NBL + Afflux)
Width of opening Required
Provide Width of opening
Take vertical Clearance
Slab Depth i/c wearing

For,

-1

c2L12

2g

(0.24+0.075)

The afflux should be kept minimum and limited as far as


possible to 150 mm

0.150 M

Q/V

=
=
=
=

0.963
1.189
0.810
1.000

=
=

0.150 M
0.315 M

A.Sarkar

SqM
M
M
M

For,

Demeo
FRL (NBL+Height of Waterway + Clearance +
Slab Depth+Wearing Coat)

For,

A.Sarkar

99.204

For,

Anda mungkin juga menyukai