CHAPTER 1

INTRODUCTION
1.1 General introduction
Analytical chemistry may be defined as the science and art of determining the
composition of materials in terms of the elements or compounds contained in them.
Infact,analytical chemistry is the science of chemical identification and
determination of the composition (atomic,molecular,phase) of substances and materials
and and their chemical structure.
The main object of analytical chemistry is to develop scientifically
substantiated methods that allow the qualitative and quantitative evaluation of materials
with certain accuracy. Analytical chemistry derives it’s principles from various branches
of Science like chemistry,physics microbiology,nuclear science, electronics. This
method provides information about the relative amount of one more of these
components.

1.2 Selection of the most appropriate analytical method


should taken in to account the following factors.

 The purpose of the analysis, the required time scale and any cost
constraints.
 The level of analyte (s) expected and the detection limit required.

 The nature of the sample, the amount available and the necessary sample
preparation procedure
 The accuracy required for a quantitative method.
 The availability of reference materials , standards chemicals and solvents
instrumentation and special facilities.
 Possible interferences with the detection or quantitative measurement
of the analyte and the possible need for sample clean up to avoid
matrix interference.

2
1.3 Different methods of analysis
By using this process the components of interest is separated and analysed by using
the following techniques .

(a) Spectral methods :-


The spectral techniques are used to measure electromagnetic radiation
which is either absorbed or emitted by the sample
e.g.- U.V. visible spectroscopy ,I R spectroscopy, N M R,
ESR spectroscopy, flame photometery , fluorimetery.

(b) Electro analytical method:-


Electro analytical methods involved the measurement of current voltage or resistance
as a property of concentration of the component in solution mixture.
eg.:- Potentiometry , conductometry, amprometry.

(c) Chromatographic methods :-


Chromatography is a technique in which chemicals in solutions travel down columns or
over surface by means of liquids or gases and are separated from each other due to
there molecular characteristics.
eg:- Paper chromatography
Thin layer chromatography
High performance thin layer chromatography
High performance liquid chromatography
Gas chromatography

3
1.4 ULTRAVIOLET SPECTROPHOTOMETRY
The technique of ultraviolet-visible spectroscopy is one of the most frequently employed
techniques in pharmaceutical analysis.
Molecular absorption in ultraviolet & visible region of spectrum is depend on the
electronic structure of molecules. Absorption of energy as quantized, resulting in the
elevation of electrons from orbital in the ground state to higher orbital in the exited state.
The wavelength range of u.v. radiation starts at the blue end of the visible light
and ends at 2000 Ǻ.
The ultraviolet region is subdivided in to two spectral regions.
(1) The region between 2000Ǻ-4000 Ǻ is known as near as U.V. region.
(2) The region below 2000 Ǻ is called far or vaccume U.V. region.

1.4.1 Principle
Any molecule has either and n or combination of these electrons. These bonding and
nonbonding (n) electrons absorb the characteristics radiation and undergo transition
from ground state to exited state. By the characteristic absorption peaks the nature of
electrons present and hence the molecular structure can be elucidated
Ultraviolet absorption spectra arise from transition of electron or electrons with in a
molecule or an ion from a lower to higher electronic energy level and the ultraviolet
emission spectra arise from the reverse type of transition.
When a molecule absorbs ultraviolet radiation of frequency v sec -1, the electron in that
molecule undergoes transition from a lower to a higher energy level or molecular orbital,
energy difference is given by-
E=h v erg
The actual amount of energy required depends on the difference in energy between the
ground state E0 and excited state E1 of the electrons.
E1 -E0 =hv
We known that total energy of a molecule is equal to the sum of electronic vibrational
and rotational energy. The magnitude of these energies decrease in following order :- E
etec , E vib and E rot.

4
The most important characteristic of spectrophotometry are there wide applicability, high
sensitivity, moderate to high sensitivity, good accuracy and convenience. The assay of
an absorbing substance may be quickly carried out by preparing a solvent in a
transparent solvents and measuring its absorbance at a suitable wavelength.
This is governed by Beer-Lambert’s law which states-
A =abc

Where,
 A is the absorbance.
 a is the absorbitivity.
 b is the path length.
 c is the concentration.

1.4.2 Instrumentation
(a) Source of light: - The best source of light is the one which is more stable, more
intense and which gives range of spectrum from 180-360 nm (up to 400 nm). The
different sources available are: -
1. Tungston lamp..
2. Hydrogen discharge lamp
3. Deuterium lamp.
4. Xenon discharge lamp.
5. Mercury arc.

The details are as follow:-

(i) Tungston lamp:- The various radiation sources are as follows:


The two most common radiation sources are tungsten lamps and
hydrogen discharge lamps. The tungsten lamp is similar in' its functioning to an electric
light bulb. It is tungsten. Filament heated electrically to white heat. It has two
shortcomings. The intensity of radiation at short wavelengths (<350 nm) is small.

5
Furthermore, to maintain a constant intensity, the electrical current to the lamp must be
carefully controlled. However, the lamps are generally stabled, robust, and easy to use.
Typically, the emission intensity varies with wavelength.
(ii) Hydrogen discharge lamps:-
In these lamps, hydrogen gas is stored under relatively high pressure. When an
electric discharge is passed through the lamp, excited hydrogen molecules will be
produced which emit UV radiations. The high pressure in the hydrogen lamps causes
the hydrogen to emit a continuum rather than a simple hydrogen spectrum.
Hydrogen lamps cover the range 3500-1200 A. These lamps are stable, robust and
widely used.
The hydrogen discharge lamp consists of hydrogen gas under relatively
high pressure through which there is an electrical discharge. The hydrogen molecules
are excited electrically and emit UV radiation. The high pressure brings about many
collisions between the hydrogen molecules, resulting in pressure broadening. This
causes the hydrogen to emit a continuum (broad band) rather than a simple hydrogen
line spectrum. The lamps are , stable, robust, and widely used. If deuterium (D2) is used
instead of hydrogen, the emission intensity is increased by as much as a factor of 3 at
the short-wavelength end of the UV range. Deuterium lamps are more expensive than
hydrogen lamps but are used when higher intensity is required.
(iii) Deuterium lamps:-
If deuterium is used in place of hydrogen, the intensity of radiation emitted is 3 to
5 times the intensity of a hydrogen lamp of comparable design and wattage.
Deuterium lamp is more expensive than hydrogen lamp. But, it is used when high
intensity is required.
(iv) Xenon discharge lamps:-
In these lamps, xenon gas is stored under pressure in the range of 10-30
atmospheres. The xenon lamp possesses two tungsten electrodes separated by about
8 mm. When applying a low voltage forms an intense arc, the ultraviolet light is
produced.
The intensity of ultraviolet radiation produced by xenon discharge lamp is
much greater than that of hydrogen lamp.

6
(v) Mercury arc:-
In this, the mercury vapour is under high pressure, and the excitation of mercury
atoms is done by electric discharge. The mercury are, a standard source for much
ultraviolet work, is generally not suitable for continuous spectral studies because of the
presence of sharp lines or bands.

(b) Monochromators:-
Filters and prism monochromators are not used because of low resolution. On the other
hand grating provides a band pass of 0.4 to 2nm. Hence they are more widely used,
especially in expensive spectrophotometers .the mirrors, gratings etc are made up of
quartz, since glass absorbs UV radiations from 200-300 nm. mirrors are front surfaced
to prevent absorption of radiation .
e.g.: - Prism.Gratings

(c) Sample cells:-


The design of sample cell used are similar to that used in colorimetry except that it is
made up of quartz. Quartz cells only must be used UV spectroscopy since glass cells
will absorb UV radiation. The path length of the cell are 10nm or 1cm.

(d) Solvents:-
Solvent plays an important role in UV spectra. Hence the solvent for a sample is
selected in such a way that the solvent neither absorbs in the region of measurement
not affects the absorption of the sample.

(e) Detectors:-
Although any one of the detectors used in calorimetric can be used, photomultipliter
tubes are mainly used, since the cost of such UV spectrophotometers are high and
more accurate measurements are to be made.
E.g.: - (1) Barrier layer cell or photo voltaic cell.
(2) Photo tubes (or) photo emissive cell.

7
(3) Photo multiplier tubes (PMT).

DOUBLE - ULTRAVIOLET
BEAM SPECROPHOTOMETER

Attenuators
1.4.3 APPLICATION Sample
(1) Qualitative Analysis:-
(a)Prism
Detection of impurities: To limit the presence of impurities, we can use
UV spectrophotometer measurements additional peaks can be due to Photomultiplier
Photomultip
M1 impurities in the sample and can be compared with that of standard raw
material. Also by absorbance measurement as specificReference
wavelength the
impurities can be detected.
(b) Structure elucidation Rotating
of organic compound
Sector
(c) Structure
Lamp analysis of organic compound
Monochro- Beam
(Source
2) Quantitative -
Analysis:- Sample Detector
mator splitter chamber

(a) Using values can we find out the quantity of drug molecule?
(b)Single standard or direct comparison method.
(c)Calibration curve method .

(3) Determination of molecular weight


(4) Determination of dissociation constant of acids and bases
(5) Chemical kinetics
(6) Identification of unknown compound.
(7) Detection of poly nuclear hydrocarbons.
(8)Determination of conjugation of geometrical isomerism.
(9) Identification of the compound in different isomerism.

8
(10) Detection of functional groups.
(11) Dissociation in conjugate and non-conjugate

DRUG PROFILE

Drug name:- DICLOFENAC SODIUM

International-Brand-Name :- FENAC PLUS,


DICLOWIN PLUS

Structure :-

Systematic-(IUPAC) name:--2-(2-(2,6-dichlorophenylamino)phenyl)acetic acid

Molecular MASS :- 296.148 g/mol

Empirical formula: - C14H11Cl2NO

9
Dose:- Oral: Adults: 50 mg twice daily

Therapeutic category:- NSAID’S

Reported use:- PAIN KILLER

DRUG PROFILE

Drug name:- PARACETAMOL

International-Brand-Name :- DOLO,
DOLOPAR,
CALPOL,
METOPAR

Structure :-

Systematic-(IUPAC)name:--- N-(4-hydroxyphenyl)acetamide

10
Molecular MASS :- 151.169 g/mol

Empirical formula: - C8H9NO2

Dose:- Oral: Adults: 500 mg twice daily

Therapeutic category:- NSAID’S

Reported use:- ANTIPYRETIC


Description of drug:-
These are the drug used in the treatment of fever pain respectievely.these have
novel mode of action that differentiates it from non-steroidal anti-inflamm Clinical trials
have shown tha Pracetamol & diclofenac sodium is highly effective in relieving the
symptoms of fever and pain. antiflammatory drugs (NSAIDs) and other conventional
forms of drug therapy.

Solubility :-

Paracetmol:- It is soluble in hydrochloric acid .

Diclofenac sodium:- It is soluble in sodium hydroxide

Storage:-
Store in tightly closed container, and reach out from the children,store
the tablet away from light , at room temperature or in the refrigerator.

Presentation:- FENAC PLUS - Blister of 10 Tablet.

11
CHAPTER 2

12
OBJECTIVE
AND PLAN OF WORK

OBJECTIVE

 SPECTROPHOTOMETRIC ANALYSIS OF PARACETAMOL &


DICLOFENAC SODIUM FORMULATION.

1) Plan of work

1. Determination of the partition coefficient.


2. λ max determination of Paracetamol.
3. λ max determination of Diclofenac sodium.
4. Preparation of calibration curve of Paracetamol.
5. Preparation of calibration curve of Diclofenac sodium.
6. Preparation of sample of paracetamol.
7. Preparation of sample of Diclofenac sodium.

2) Material & Method


1. Hydrochloric sodium 0.1 N .
2. Sodium hydroxide 0.1 N .

13
3. Distilled water (H2O )
4. Paracetamol drug ( Pure form )
5. Diclofenac sodium.

CHAPTER 3

14
EXPERIMENTA
L
3.1 λ max determination:-

15
The uv spectrum of paracetamol and diclofenac sodium in solvent like methanol,0.1N HCL ,
0.1N NAOH . were recorded for a different concentration 10µ g /ml. The spectrum of
paracetamol and diclofenac sodium was found to have good spectrum pattern and
maximum absorbance was obtained . Hence 0.1 N NAOH was selected as the solvent .
the maximum absorbance was found to 257 nm for the paracetamol and 252 for
the diclofenac sodium .

Fig.3.1.1 Spectrum of Diclofenac in NaOH

16
Fig.3.1.2 Spectrum of Paracetamol in hydrochloric acid

3.2 Preparation of caibration curve of

1) Paracetamol:-
The pure compound of paracetamol 100mg dissolve in 100 ml 0.1N HCL .form the 10ml
take in 100ml volume metric falsk from this 10 ml take in 100 ml volume metric falsk to
make 10 mg/ ml .solution form this we have made different concentration solution line 2 mg
/ml,4 mg /ml,6 mg /ml,8 mg /ml,10 mg /ml.
The paracetamol was found to have maximum absorbance 257nm and hence it was
selected for further studies.

17
2) Diclofenac sodium :-

Stock solution of diclofenac sodium of 1000mg/ml was prepared by taking 100mg of durg
dissolved and diluted to 100 ml with 0.1N NaOH.the above stock solution was suitably
diluted with NaOH to get concentration ,ranging from 2-10µ g/ml and absorbance were
noted at 252nm and the overlain spectra were show in fig.3.2.2.

Table3.1 :- Data represent the absorbance of the different


concentration of paracetamol at 257.0 nm.

S no. Cocentration absorbance


Цg /ml
1 1 1.008

2 5 1.625

3 10 1.756
4 15 1.757
5 20 1.758

18
Table3..2 :- Data represent the absorbance of the different
concentration of diclofenac sodium in 252.0 nm.

S no. Cocentration absorbance


Цg /ml
1 2 0.789

2 4 1.365

3 6 1.677
4 8 1.712
5 10 1.731

19
Fig.3.2.1 Dilution of paracetomol

20
Fig.3.2.2 Dilution of diclofenac sodium

21
parcetomal standard graph

0.9

0.8

0.7

0.6
Abs

0.5 Series1

0.4

0.3

0.2

0.1

0
1µg/ml 5µg//ml 10µg/ml 15µg/ml 20µg/ml
conc

Fig.3.2.3 Calibration graph of paracetamol in 257nm

22
Dichlofinac sodium standard graph abs

1.2

0.8
Abs

0.6

0.4

0.2

0
2µg/ml 4µg/ml 6µg/ml 8µg/ml 10µg/ml
conc

Fig.3.2.4 Calibration graph of diclofenac sodium in 252nm.

23
3.3 prepartion estimation in sample solution of fenac plus :-

20 tablet of 250mg of paracetamol and diclofenac sodium and average weight. Was
calculated

1) sample solution of paracetamol:-

Weigh accurately powder sample equivalent to about 100mg of paracetamol carry out
the dry portion with three 25 ml portion of 0.1N HCL filtering through by sinterdred glass
funnel. Dilute the combined filterate to 100ml with acid dilute further appropriately with acid
got final concentration 100mg /ml .

paracetamol sample graph

1.8

1.6

1.4
1.2
abs

1 Series1

0.8

0.6

0.4

0.2

0
2 µg/ml 4µg/ml 6µg/ml 8µg/ml 10µg/ml
conc

24
2) sample:-
The entire residue left after the extraction of paracetamol as described above is used for
estimation of diclofenac sodium. Transfer the residue left in the conical flask and the top
of sintered fannel.qualitatively to 100ml volumetric flask with the help of 0.1 N NAOH
make up the volume and carry out the further dilution appropriately with NAOH toget final
concentration of 100 µ g/ml.

diclofenac sodium sample

2
1.8
1.6
1.4
1.2
abs

1 Series1
0.8
0.6
0.4
0.2
0
2 µg/m l 4µg/m l 6µg/m l 8µg/m l 10µg/m l
conc

25
RESULT AND DISCUSSION:-

On the basis of experimental data.The paracetamol showed maximum absorbance at


252nm in HCl and diclofenac sodium showed maximum absorbance at 257nm in
NaOH.The data of precision given on method is more accurate and an equal but little time
different from the standard value or calibration curve.

CHAPTER 4
26
BIBLIOGRAPHY
4.1 Bibliography

• Douglas-A.-Skoog,-Donald M.West, and JamesF. Holler: Fundamentals of analytical


chemistry :Page No564-567 5th edition.

27
• Gurdeep=R.chatwal,-Sham-K.ANAND:Instrumentalmethods_of_chemical
analysis:Page No. 2.149-2.151, 2.160-2.161,2.176-2.178: 5th edition.
• J.denny-R.C,-Barnesj.d,Thomas M:Textbook of quantitative chemical analysis:Page
No. 278-279:6th edition.
• Scientific & research Publication from , Indian Drug manufactures association :Indian
Drugs :Vol.44 : No 1 :January 2007 :Page No 13 .
• Scientific & research Publication from , Indian Drug manufactures association :Indian
Drugs :Vol.44 : No 2 : February 2007 :Page No 145 .
• Scientific & research Publication from , Indian Drug manufactures association :Indian
Drugs :Vol.44 : No 3 : March 2007 :Page No 209-210 .
• Sharma B. K. Instrumental Methods of chemical analysis :Page No.S-46,S-52 :1 st
edition.