NOTE: SEE OTHER SECTIONS FOR TYP. WALL REINF
CUT_CMU_AT BRC.
f—— AS_ REQUIRED FOR———>
/ T/BEAM EL
/ BEAM-SEE PLAN ——
/__¢, T/BEAM-SEE PLAN
FILL BLOCK CORES AT BEAM
M—BRG. WITH 2500 psiCOARSE GROUT—>4
AND 1-*6 CONT. AT EACH CORE, 2
MIN: (TYP. FULL HT.)
SECTION ELEVATION
LC BRG. PLATE-34"%x7"'x1'-0"
= (WITH aa D HOLES)___ Vv
WITH 2-56" dio.x8" LONG \. /
ANCHOR BOLTS
= <—— BEAM-SEE PLAN —~ PARALLEL,
~ TO_WALL
r
PLAN LVoxWox He —T_
x
PERPENDICULAR =
TO WALL AT BEAMS LONGER
THAN 25°-0" USE THIS
CONNECTION ONE
END ONLY
@® TYPICAL BEAM BEARING @ MASONRY WALLSEXTEND BEAN TQ ————__—-|
BACKSIDE OF BEARING
PLATE
NEW MASONRY WALL
FILL POCKET SOLD WITH MASONRY
AFTER BEAM IS WELDED TO PLATE.
BEARING PLATE~SEE
‘SCHEDULE,
ANCHORS~SEE ——
SCHEDULE
FILL CORES SOLID WITH GROUT —t
UNDER BEARING PLATE 3
COURSES DEEP BY 3 COURSES
WIDE TYPICAL.
BEAM SEE PLAN
L. 1/2" cour Leveuine BED
S| SET BACK PLATE 1/2"
Note:
1, MASONRY REINFO
ING NOT SHOWN FOR
SHORT DIMENSION OF BEARING PLATE
UNLESS OTHERWISE NOTED ON PLAN
CLARITY.
WARK | BEARING PLATE SIZE| ANCHORS (FLOOR) | ANCHORS (ROOF)
. yogr | 2n3/# xB” LONG | 2-#4x15" LONG
Beat | 172" x 8" x 0-8 | Feadeo stuos | REINF. BAR STUDS
BP-2
BEAM BEARING ON.
MASONRY DETAIL
$2.32 COURSES OF CMU BLOCKS
GROUTED GROUTED SOLID W/
_ -—2x FURRING, SEE ARCH
l PLANS FOR WALL TYPES.
m7
(2) CONT. #5 BOT. BARS IN byt
FULLY GROUTED CELLS @ Lh |
FlooR LEVELS ——____ Ff |
——GYPCRETE OVER APA RATED
FLOOR SHEATHING,
CONT. (2) 2x10 LEDGER
ATTACHED TO BOND BEAM W/
(2) ROWS OF }"8 EXP. BOLTS
W/ 4" MIN, ENBEDVENT @
48°0.C, STAGGER 24”
INSTALL BOLTS JUST PRIOR
4 TO PLACEMENT OF DRYWALL.
FLOOR TRUSS DESIGNED &
SPACED BY MANUF,
MU
TRUSSES PARALLEL
LEDGER ATTACHMENT AT C
SCALE: 3/4" =(2) ROWS 2x BLOCKING
BETWEEN FLOOR TRUSSES
= (2) 2x10 LEDGER GLUE &
NAIL TOGETHER W/ (3) ROWS
12d @ B" 0.0. ATTACH TO
MASONRY WALL W/ (2)
ROWS 1/2" 8x10" EXPANSION
BOLIS @ 24" 0.C,
8° CMU TOWER, SEE PLAN
NOTES FOR REINFORCING. —
GROUT SOUD BEHIND LEDGER
FOR PROPER ANCHOR BOLT
PLACEMENT,
8° CMU LINTEL WY (2) #5
CONT. BOT. BARS —————__
REFER TO_ARCH. PLANS. a
FOR LOCATIONS AND CLEAR
OPENING HEIGHT
TOP CHORD BEARING FLOOR
‘TRUSSES SEE PLAN,
— 2x FURRING, SEE ARCH
PLANS FOR WALL TYPES,
7 LEDGER ATTACHMENT AT CMU.
5. SCALE: 3/4" = 1'-0" TOP CHORD BEARING TRUSS