Anda di halaman 1dari 5

Evaluation of OPA2846 Evaluation Board Ver2

Rise Time Calculation for OPA2846 :


Condition 1:

1. Laser pulse (Modulated pulse-50kHz,Power- 100uW) from the Light wave


measurement unit given to the board.
2. First amplifier stage has 10k feedback resistor and 0.5pF Capacitor.

Fig1.Op-amp A Out First Stage Fig2.Op-amp B Out First Stage

Condition 2:

1. Laser pulse (Modulated pulse-50kHz, Power- 100uW) from the Light wave
measurement unit given to the board.
2. First amplifier stage has 10k feedback resistor and 1pF Capacitor.

Fig3.Op-amp A Out First Stage Fig4.Op-amp B Out First Stage


Condition 3:

3. Laser pulse (Modulated pulse-50kHz,Power-0dBm 20db Attenuator


PIN In
Board) from the Light wave measurement unit given to the board.(Power-10uW)
4. First amplifier stage has 10k feedback resistor and 1pF Capacitor.

Fig5.Op-amp A Out First Stage

Fig6.Op-amp B Out First Stage


Fig7.Op-amp B Out Second Stage

Fig8.Op-amp B Out Second Stage


Rise Time Calculation for OPA657 :
Condition 1:

1. Laser pulse (Modulated pulse-50kHz,Power-0dBm 20db Attenuator


PIN In
Board) from the Light wave measurement unit given to the board (Power-10uW).
2. First amplifier stage has 10k feedback resistor and 0.5pF Capacitor.

Fig11.Op-amp A out First Stage Fig12.Op-amp B out First Stage

Observation1:

1. The rise time of OPA2846 after first stage is 26ns.


2. The rise time of OPA2846 after second stage is 26ns.
3. The rise time for OPA657 is 20ns.
4. After changing new 1pF(0.5pF+0.5pF) capacitor in the first stage feedback, the
same rise time is observed in the two stages.
Rise Time Calculation for OPA2846 :
Condition 4:

1. Laser pulse (Modulated pulse-50kHz,Power- 100uW) from the Light wave


measurement unit given to the board.
2. 1st stage has 10k feedback resistor and 0.5pF Capacitor.
3. 2nd stage has gain 33 and 4pF at the feedback.

Fig11.Op-amp A out First Stage Fig12.Op-amp B out First Stage

Fig21.Op-amp A out Second Stage Fig21.Op-amp B out Second Stage

Observation2:

1. The rise time of OPA2846 after first stage is 21ns.


2. The rise time of OPA2846 after second stage is 58ns.
3. If we compare it with the simulation results, the bandwidth is approximately equal
to practical obtained bandwidth in the board.

Anda mungkin juga menyukai