The document outlines regular optimization work flows for addressing issues with BSC KPI trends, including checking for alarms and problems at the BSC, MSC, TRAU and transmission levels, investigating the worst performing cells through drive testing, checking cell parameters and surrounding cell performances, and escalating any unresolved problems to the NOC/FM team for on-site troubleshooting.
The document outlines regular optimization work flows for addressing issues with BSC KPI trends, including checking for alarms and problems at the BSC, MSC, TRAU and transmission levels, investigating the worst performing cells through drive testing, checking cell parameters and surrounding cell performances, and escalating any unresolved problems to the NOC/FM team for on-site troubleshooting.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PPT, PDF, TXT atau baca online dari Scribd
The document outlines regular optimization work flows for addressing issues with BSC KPI trends, including checking for alarms and problems at the BSC, MSC, TRAU and transmission levels, investigating the worst performing cells through drive testing, checking cell parameters and surrounding cell performances, and escalating any unresolved problems to the NOC/FM team for on-site troubleshooting.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PPT, PDF, TXT atau baca online dari Scribd
CCS RNO Engineer, NTS-Huawei EJV Project Escalate the problem Clear the Alarm or Escalate the Check BSC KPI Trend Problem to NOC/FM to concerned department Identify Worst Performing Change the incorrect parameters Cells per KPI Check for Analyze CTRX Results and BSC/MSC/TRAU/ associate them with KPI trends. Transmission Level Check Cell Level Trend of activities or problems the Identified Worst Cells Conduct Drivetest if CTRX/performance Data is Check for insufficient to identify the problem. Yes BTS/TRX alarms: Is the problem global? BTS module on site Lock and unlock TRXwith bad quality Consistency No Check of Cell Level Escalate the problem to NOC/FM Parameters team for on-site troubleshooting: TRX Swap/replace, VSWR check, Check CTRX scan Feeder, Antenna and Connectors check. Investigate on possible causes or reason of Check surrounding degradation Revert the activity or Verify the results cell performances troubleshoot. through Statistics
Check for any activity
on the site such as Yes Problem Solved? END Upgrades, Antenna Replacements, etc. No