2. TELT IV 1985
3. BMSC IV 1986
4. BSC I 1986
6. SUSBAMENJUR XI 2000
7. SETUKPA VI 2004
PRIMER EXTERNAL POWER
28 V DC 300 A A P U 28 V DC
APU
UTILITY
- START ENGINE
- SERVICING
- MRBH ARUS DC KE AC
SEKUNDER 115 V AC 400 HZ
1
3
- STEP DOWN
2 115 26 V AC
24 V DC 40 AH
24 V DC 7 AH
- START ENGINE
- EMERGENCY/ STBY
G G BATT BATT BATT
APU 28 V DC 24 V DC
1 2 3 7 AH
BUS
28 V DC 24 V DC 0,3 V
TIED
40 AH
REVERS
SEC BUS BAR ESS BUS BAR CURRENT AUX BUS BAR
RELAY
( RCR )
EMERG NORM
AUX 115 V AC INV INV
UTILITY 400 HZ
INV 1 2
CONTROL BOK
1
TRANSFORMER
AC BUS
AC BUS 115 V AC
26 V AC 400 HZ
2
PRIMER 28 V DC 300 A
EXTERNAL POWER
A P U 28 V DC
- START ENGINE
SEKUNDER - SERVICING
24 V DC 40 AH
24 V DC 7 AH
- START ENGINE
- EMERGENCY/ STBY
RCR APU BUS UTILITY
AUX BUS BAR ESSENTIAL BUS BAR SECONDARY BUS BAR
TIED
PA 26
24 V
PA 27
OFF
BAT BAT
NO 1 2
1 48 V
OFF
ON
NO 2
MASTER
ON
SWITCH 200
OFF 100
300
STARTING BUS BAR
A 10%
0 60%
ON
AIR AIR
OFF OFF
START
ON ON
• INSTRUMEN YG DIPERHATIKAN SAAT ENGINE START DG NTS CHECK
1. MONITOR VOLTASE a. BATT DROP 18 VOLT
b. APU DROP 22 VOLT
2. NTS LIGHT OFF
3. 10 – 12 RPM , IGNITION ON
4. MONITOR RPM RAISE
EGT RAISE
FUEL FLOW RAISE
5. 20 % RPM , NTS LIGHT ON
P/L GROUND IDLE ( G I )
6. 30 % RPM , OIL PRESS RAISE
7. MONITOR RPM RAISE
EGT RAISE NOT OVER 770
FF RAISE
STARTER GENERATOR
MEMILIKI 2 FUNGSI:
–SEBAGAI STARTER PD
SAAT MELAKS START E/G
(MEMUTAR & AKSELERASI)
PA 61 PA 62
200 A 200 A
GCU
GCU
20
10
SHUNT 30 SHUNT
LEFT GEN RIGHT GEN V
0
RESET RESET AMM
AMM
VOLT SELEC
OFF OFF LEFT RIGHT
GEN GEN
200
200 100
100 ON ON ESS BUS
300
OVER OVER 300
0
A
0
A
LOAD LOAD
PA 14
GENERATOR PA 13 GENERATOR
GENERATOR IN OPERATIF
1. Generator swt - OFF
2. DC Ammeter – CHECKED
3. DC Volt meter – CHECKED
4. Generator Swt – RESET
if Generator Warning Light Remin ON
5. Generator Swt – OFF
if Both Generator Fail
6. Bus Tied Swt – EMERGENCY
7. Non Essential Item of Electrical Equip - OFF
1 2
- PARAREL + +
V TETAP, A TETAP, T LAMA
24 X 40 = 960 WATT
ESSENTIAL BUS BAR 24 V / 28 V
48 V
OFF
ON RELAY SERI
SW BAT 24 V
BAT BAT PARALEL
SERIE - PARALLEL
48 V
OFF
ON
ESS BUS BAR
TES SWITCH
ON
A
M
P WA 26 BATTERY
TEMP NO 3
WA 35
S BATTERY
TEMP NO 1
E BATTERY
N TEMP NO 2
S BATTERY
OVERTEMP
O
R
66˚C 54˚C
SENSOR
BATT 3 BATT 1 BATT 2
APU PICK UP POINT
INPUT
28VDC 600 -1200AMP
POWER
PA 26
UTILITY
- + +
OFF
PA 27 APU
ON ON OFF
OFF BAT 1 BAT 2
ON APU
MASTER SWITCH
• SUMBER DR 3 BUAH STATIC INVERTER YG
• 3 BUAH INVERTER TERDIRI DR :
- 2 BUAH NORMAL
- 1 BUAH AUXILIARY
• FUNGSI DR INVERTER SENDIRI BUKAN
MENGHASILKAN TTP MERUBAH TEG 24-28
VDC MJD 115 VAC
• INVERTER WARNING LIGHT MENYALA JK:
• TEG TURUN DI BAWAH 90 VAC ATAU
OUT PUT 20 WATT
• BILA TEG MELEBIHI 115 VOLT AC
• 1 BUAH TRANSFORMER
1 2
OFF ON ON
OFF
AC BUS AC BUS
115 V 115 V
ON
OFF
CONTROL 100
BOX 50
XA XA XA AC BUS
29 30 26 V
31 V 150
1 2 0
INV WARNING
INV 1 INV 2 1 2 3
INV 3
ON ON ON NO 2
IGNITION NTS LIGHT
0 0
9
0
1
10 9
0
1 10
2 8 2
8
3
20 7 3 20
7
4 6 4
6 5 5
100 30 100 30
PERCENT PERCENT
90 40 90 40
RPM RPM AIR
80 50 80 50
70 60 70 60 OFF
GND
7 7
6 8 6 8
5 C X 100 9 5 C X 100 9
4 EGT 10 4 EGT 10
3 11 3 11
2 2 20
4 7
2 3 68
05
9 4 0
2 3 76
8
95 10
30
V
0
0 600 0 LBS/HR
600
LBS/HR