TECHNICALSPECIFICATIONS

Running Capacity 24.0kW / 415V / 3Phase / Delta Connected


Installed Capacity 30 kW
Installed Spare Capacity 6 KW
No. Of Zones 1
Service Temperature 200 ºC
Design Temperature 250 ºC
Operating Pressure 20”W.C.
Design Pressure 10.0Kg/cm2

Fluid Air
Flow Rate 421 m3 / hr

Inlet Temperature 35 ºC
Outlet Temperature 180 ºC
Over all Bundle Length Approx.1850mm
Support Arrangement 25%cut baffles arrange on tie rods.
No. Of Baffles 4Nos.,arranged on tie rods
Baffle and tie rod material S.S.304Grade
Heating Elements
U shape mineral filled metal sheathed heating elements brazed to flange

Resistance Alloy Nichrome 80/20 Grade


S.S304 Grade ERW Tube
Heating element sheath material
11.0mmx0.7mmThk.
Diameter of heating element tubes

No. of heating elements 12Nos.+3spare


Rating of each element 2000W/415V
Immersed Length 1500 mm
Ineffective Length behind the 200 mm
flange
Effective Length 1300 mm
Watt Density 2.22W/cm2
Terminal Box M.S. fabricated, powder coated terminal cover. Please advise cable entry
diameters
Accessories Thermo well provided in centre of flange
Flange Detail
Blindflangewithraisedface,size200NB/150#asperANSIB16.5
Flange/Tube Sheet Material M.S.

Heater Vessel Summits scope