In order to avoid low temperature corrosion, the feed water temperature must not, even in the
lower load range, drop significantly below the acid or water dew point. On the other hand, this
temperature must be as low as possible in order to assure good utilization of the heat available, as
discussed in chapter 4. It is therefore recommended that the feed water temperature be held at a
constant level corresponding approximately to the acid dew point.
For the control loop shown on the diagram deaerator heating is done primarily with a steam turbine
extraction, but if the pressure in this extraction is not sufficient at any load point then pegging steam
from a live steam source (LP in figure 7-3) is used. In plants with a low pressure preheater loop in the
HRSG, the opposite problem could occur during part load operation of the gas turbines, where more
low pressure steam could be generated than required. This excess energy must be dissipated either
by increasing the pressure in the feedwater tank/deaerator, which reduces the amount of steam
generated, or by directing the excess low pressure steam to the condenser, which again slightly
increases the vacuum and therefore marginally lowers steam turbine output.
Untuk putaran ditampilkan pada diagram deaerator pemanasan dilakukan terutama
dengan ekstraksi turbin uap, tetapi jika tekanan pada ekstraksi ini tidak cukup pada setiap titik
beban kemudian mengelompokkan uap dari sumber aliran uap (LP dalam gambar 7-3)
adalah digunakan. Dalam pembangkit dengan putaran preheater tekanan rendah
di HRSG, masalah sebaliknya bisa terjadi selama pengoperasian bagian beban dari turbin gas, dimana tekanan
uap yang lebih rendah dapat dihasilkan dari yang dibutuhkan. Ini kelebihan energi harus sangat baik dengan
meningkatkan tekanan di dalam tangki air suplai/ deaerator, untuk mengurangi jumlah uap yang
dihasilkan, atau dengan mengarahkan uap bertekanan rendah ke kondensor, yang sangat
sedikit meningkatkan vakum dan karena itu sedikit menurunkan turbin uap output.