QUICK START:
Make sure system bypass is on, no water is flowing in the unit, and the customer has water to the house.
Step 1:
Make sure the inlet is on the left and outlet is on the right. The drain should run to an authorized location.
Step 2:
Set time—press the scroll button once. The screen reads “Set”. Using the up and down arrows set the correct time.
When done press scroll 4 times until the time is re-displayed.
Step 3:
To change the factory settings, hold down arrow until the screen reads “Systems Check”. When you see this display,
release down arrow and re-press the down arrow.
DOWN, DOWN, SCROLL DOWN. THE SCREEN SAYS “CAPACITY 1000 GL”
Step 4:
Press the scroll button until you see “Back Wash 10 min”. Change to “5 min”.
Press scroll 2 more times until the screen reads “FILL/RNS 5 min”. Change to “1 min”.
STEP 5:
Press scroll one time, the screen will read “Change Phone Number No”. (Press the down arrow, the screen will
read “Yes”).
Press the scroll button one time and the first 0 will flash. Using the up and down arrows select “0-9”, press the
scroll button to advance to the next number and repeat until the last digit. When you get to the last digit, press
the scroll button and the screen will read “Exit”. Press the down arrow. The time and volume will be displayed.
Should you have any questions or technical difficulties please call Sam or Pat
in Technical Support at 1-800-811-3498. If you cannot reach Technical Support,
please contact Eric Brockmire at 847-431-1324.
Part No. 37136 REV B
© 2010 ProSystems Division of AWTP, LLC