Anda di halaman 1dari 1

Resetting to factory defaults

Factory defaulting ruggedized products

To reset a ruggedized product to factory defaults, follow this procedure:

1. Disconnect any cable from the AP.

2. Disconnect power from the PoE injector.

3. Configure your computer LAN port with a static IP address of 192.168.1.2 and a subnet
mask of 255.255.255.0.

4. Use a Cat 5 Ethernet crossover cable to connect your computer LAN port directly to the
PoE injector Data In port.

5. Connect a Cat 5 Ethernet cable from the PoE injector Data and Power Out port directly
to the AP.

6. Open a command line session on the computer.

7. In the folder containing the script, specify the script name including its language
identifier and the factory parameter like this:
MSMRemote-en factory
Press Enter to execute the script.

8. Power on the PoE injector. The script performs the reset and confirms success with a
message like this:
Your "R" product has been successfully factory reset!

9. Once the factory reset completes, perform the procedure found in the Initial software
configuration section of the AP Quickstart.

D-5