Anda di halaman 1dari 22

Actuator Types

Control Versions of Integral Starter Units


Auma e-pac

The electronic version of Auma India Integral Programmable Control Logic Module consists
Starter e-pac incorporates sophisticated of
electronic controls with field programming
feature. E-pac is modular in construction and Inching & Non-inching in local mode by dip
consists of Power Supply Module, Relay switches
Module & Programmable Control Module. Inching & Non-inching in remote mode by dip
switches
Power Supply Module consists of Limit switch seating or Torque seating by dip
switches
24 V DC, 150 mA source
Wide varieties of versions of e-pac & optional
Reversing contactors electrically and
mechanically interlocked features make the actuator controls adaptable to
any field situation. Versions & optionals
Selector switch LOCAL-OFF-REMOTE,
available are :
lockable & potential free contacts for local-
off & remote Emergency shut down (ESD)
Push buttons OPEN-STOP-CLOSE for 2 wire make-break
local controls Timer board to run the actuator in ON-OFF
Single phase supply for space heater 10W steps
Open-Close inhibit
Relay Module consists of Negative switching
Remote control & local stop
Monitor relay for collective fault Electronic positioner for regulating duty, with
signals (Thermo switch trip, torque switch or without isolator
trip in mid travel) with potential free contacts Single phase protection
Local status annunciation (Green) & fault Automatic phase correction
annunciation (Red) by LEDs Remote annunciation relays
Thermal overload relay
Positioner with PID features
Wall mountable e-pac
For detailed literature, refer separate catalogue.

Auma e-pac

23
Interface
Valve Attachment

Valve attachment is according to ISO 5210 or DIN 3210

Flange Sizes
Actuator size
3 6 12 15 25 30 50 60 100
SA/SAR
Max. Torque
30 60 120 150 250 300 500 600 1000
Nm
ISO 5210 F10 F10 F10 F10 F14 F14 F14 F14 F16

DIN 3210 G0 G0 G0 G0 G 12 G 12 G 12 G 12 G3

Output Drives

Various output drive types according to ISO Output Drive Type D


5210 / DIN 3210 are available in order to
adapt the actuators to different types of valves. Stub Shaft :
Special sizes can be supplied on request.
The shaft with key engages with bore and
Output Drive Type A keyway of mating part.

Stem nut : Output Drive Type E

The output drive has stem nut for rising or non Bore with Keyway :
rotating valve stem. The mounting flange
together with stem nut and thrust bearings form This type is mainly used for connecting to a gear
one assembly which is suitable for accepting box, example Auma Gear Box type GS
thrust loads. (worm / worm wheel) or GK (Bevel gear box).

Output Drive Type B Linear Thrust Unit (LTU)

Plug Sleeve : With the linear thrust unit, the rotary movement
of the actuator output shaft is converted into an
Plug sleeve has bore and keyway and is designed axial movement. Thus the multiturn actuator
for transmission of torque. becomes linear actuator. Different stroke lengths
can be provided.
Output Drive Type C

Dog Coupling : Technical Data


Linear Thrust Tr. Max. Stroke
This is similar to type B, however with dog thrust length
Unit Thread kN mm
coupling for torque transmission.
LTU 6 24 x 5 20 50 & 100
LTU 12 32 x 6 35 60 & 120
LTU 25 40 x 7 63 80 & 160
LTU 50 50 x 8 100 80 & 160

24
Interface
Electrical Connection
Terminals
Screw type terminals are used for electrical Version I :
connection as standard. Stud type terminals can
be provided for power connections. Terminals 32 x 2 = 64 pins for control
are DIN rail mountable and are available as 3 + 1 = 4 pins for power
single or double decker versions also.
Version II :
Plug socket connector
50 pin circular connector for control
The actuators can also be equipped with plug
socket connectors in two versions. 6 + 1 = 7 pins for power

Electrical Connection for Integral Starter Versions


Between actuator and compact or e-pac :
64 pin connector with 3+1 pins for power
connection or 50 pin circular connector with
6+1 pins for power connection. This simplifies
trouble shooting at site.
From compact or e-pac to customer connections:
Screw type terminals or 64 pin connector with
3+1 pins for power connection or 50 pin circular
connector with 6+1 pins for power connection.

Technical Data Screw type terminals


Power Earth Controls
Screw type terminals
Terminals max. 3 1 64
Voltage max. 750 V - 500 V
Current max. 34 A - 25 A
Type of Connection Scr or
Scr or stud Scr
stud
Cross section max. 4 sq mm 4 sq mm 2.5 sq mm
Plug socket connector 32 x 2 & 3 + 1
No. of contacts 3 1 64
Multi-pin Connector
Voltage max. 750 V - 500 V
Current max. 25 A - 16 A
Type of connections Screws Screws Screws
for customer use
Cross sec. max. 6 sq mm 6 sq mm 2.5 sq mm
Plug socket connector, circular
6
No. of contacts (3 used) 1 50
Voltage max. 750 V - 250 V
Current max. 25 A - 16 A
Circular Connector
Type of connections Screws Screws Screws
for customer use
Cross sec. max. 6 sq mm 6 sq mm 2.5 sq mm
25
Interface
Threads for Cable Glands

As standard, Auma actuators are supplied with 3 '' , 1'' can be


Additional cable glands of sizes 3/4''
4
2 cable glands with British Conduit threads provided. For additional protection under
111/
''
4 BSC. The cable glands are directly tightened extreme conditions for weather proof & water
on the threads provided in cable entry cover. At proof applications, double compression cable
the time of despatch, the cable entry opening in glands in various sizes can be supplied. NTP &
the cable gland is sealed with aluminium shim PG threads can also be provided.
& neoprene rubber sheet to prevent ingress of
dust & water.

Stem Protection Tube

To protect rising valve stem, a protection tube as a standard. If protection tube is not required,
can be fitted to the hand wheel hub. Internal the bore of the hand wheel hub is closed with lid.
threads are provided in the hand wheel hub

Actuator - Gear box Combinations


Combination with Worm Gear boxes

In combination with worm gear box of type


GS40.2 to GS500, a multiturn actuator is
converted into part turn actuator usually for 90o
movement. This is an ideal solution for large part
turn valves with high torque requirements. The
torque range goes upto 250000 Nm.

Combination with Bevel Gear boxes

By combining multiturn actuators with Bevel


gear boxes GK10.1 to GK35.1, the torque speed
ranges are considerably extended. Output
torques upto 8000 Nm and thrust load upto
820 KN are possible.

Combination with Lever Gear boxes

Louvers, dampers or valves which are operated GEAR OPERATORS

via lever arrangement require lever gear boxes.


For such application multiturn actuator is
combined with lever operated Gear box type
GF40 to GF315. The torque range goes
upto 63000 Nm.

26
Service Conditions
Enclosure Protection

Auma actuators conform to enclosure protection The lowest point of equipment is atleast 1 m
IP67 as per IS 13947 (Part I) : 1993, Appendix C. below the surface of water
Auma actuators are also available with improved Duration of test is 30 min.
enclosure protection IP68. The definition of
IP67 & IP68 as per standard is as follows : Under above conditions, ingress of water in
IP : Ingress Protection harmful quantity shall not be possible.
First numeral 6 : Dust tight, prevents ingress Second numeral 8 : Test conditions as above,
of dust. however no ingress of water is permitted.
Second numeral 7 : Protected against the effects
of immersion. Test is made by completely
immersing the equipment in water so that :
Surface of water is atleast 150 mm above
highest point of equipment.

Ambient Temperature Life Time

Temp. Auma multi-turn actuators meet the following


Type Actuator Type
Range requirements of operating cycles at 30 turns per
Standard stroke of close - open - close.
SA -20 to +80oC
Multi-turn actuator
SA3 to SA100 15000 Cycles
Multi-turn
o SAR6 to SAR100 15000 Cycles
SAR Actuator for -20 to +60 C
Regulating Duty
SAEx Explosion Proof
SAREx actuators, standard o
SACEx compact & -20 to +40 C
SARCEx regulating duty

Painting

Type of paint Epoxy Any other type & colour of paint can be provided
Standard colour DA grey IS 5 on request.
Primer thickness 40 microns min.
Paint thickness 75 microns min.

27
Service Conditions
Explosion Proof / Flame Proof Actuators

For installation of actuators in potentially Necessary approvals from statutory authorities


hazardous or explosive areas, special protective have been obtained.
measures are required. These are specified in
Indian Standard IS 2148-1981 ''Specifications Actuator Models
for Flame Proof Enclosures of Electrical
Actual Type Model
Apparatus''. Auma India actuators developed for
this purpose are suitable for group II gases and in Explosion Proof SAEx3/6/12/15
application other than coal mines. The Norm SAEx25/30/50/60
enclosures of explosion proof / flame proof Open-Close Duty SAEx100
actuators are designed in consideration of
clauses specified in IS 2148-1981 & the Explosion Proof SAREx6/12/15
actuators have been tested and certified by Norm SAREx25/30/50/60
CMRI, Dhanbad. Regulating Duty SAREx100

Explosion Proof SACEx3/6/12/15


Compact SACEx25/30/50/60
Open-Close Duty SACEx100

Explosion Proof SARCEx6/12/15


Compact SARCEx25/30/50/60
Regulating Duty SARCEx100

For details please refer separate catalogue.

SAEx3 - SAEx100
SAREx6 - SAREx100

SACEx3 - SACEx100
SARCEx6 - SARCEx100

EN ISO 9001
Certificate : 041005262

28
General
Mounting Position Functional Tests

Auma actuators also with integral controls can After assembly, all actuators are thoroughly
be operated without restriction in any mounting tested and torque switches are calibrated. Final
position. inspection record is provided to the customer.

Test Certificates

Auma actuators and critical components of


actuators have been tested & guaranteed for
performance. Some of the Type test certificates
available are listed.
Endurance Test as per GDCD Standard
Damp Heat Cycle Test as per IS 9000
Vibration Test as per IS 12075
Noise Test as per IS 12065
Enclosure Protection Test as per IS 13947
Tests on Micro Switches
Motor Performance Tests

29
Technical Data SA3-SA100
Open-Close duty
1)
Tripping Torque Auma India Valve Stem dia. Permissible Revolutions Hand Hand wheel Weight
Actuator Type Mounting Output drive Thrust for for wheel Ratio Auma India Norm
both directions
Flange Type-A Type-A Full stroke Dia.
Type Output Speed Standard Std. Std. With bevel Std. With bevel
DIN:3210 gear set gear set
2) (Special
Min.Nm Max.Nm 1/min ISO:5210) Max. mm Max. kN Min. / Max. Kgs. Kgs.
SA 3 ..... 11
SA 3 ..... 16
SA 3 ..... 22
SA 3 ..... 32 1-480
20 30 SA 3 ..... 45 G0 26 25 or 250 1:1 2:1 39 45
SA 3 ..... 63 (F10) 1-4800
SA 3 ..... 90
SA 3 ..... 1253)
SA 3 ..... 1803)
SA 6 ..... 4
SA 6 ..... 5.6
SA 6 ..... 8
SA 6 ..... 11
SA 6 ..... 16
1-480
20 60 SA 6 ..... 22 G0 26 40 or 250 1:1 2:1 39 45
SA 6 ..... 32 (F10) 1-4800
SA 6 ..... 45
SA 6 ..... 63
SA 6 ..... 90
SA 6 ..... 1253)
55 SA 6 ..... 1803)
SA 12 ..... 4
SA 12 ..... 5.6
SA 12 ..... 8
SA 12 ..... 11
SA 12 ..... 16
1-480
30 120 SA 12 ..... 22 G0 38 60 or 250 1:1 2:1 39 45
SA 12 ..... 32 (F10) 1-4800
SA 12 ..... 45
SA 12 ..... 63
SA 12 ..... 90
SA 12 ..... 1253)
110 SA 12 ..... 1803)
SA 15 ..... 4
SA 15 ..... 5.6
SA 15 ..... 8
SA 15 ..... 11 1-480
50 150 SA 15 ..... 16 G0 38 60 or 250 1:1 2:1 39 45
SA 15 ..... 22 (F10) 1-4800
SA 15 ..... 32
SA 15 ..... 45
SA 15 ..... 63
SA 25 ..... 4
SA 25 ..... 5.6
SA 25 ..... 8
SA 25 ..... 11
SA 25 ..... 16
SA 25 ..... 22 1-480
60 250 SA 25 ..... 32 G 12 52 120 or 360 1:1 3:1 72 88
SA 25 ..... 45 (F14) 1-4800
SA 25 ..... 63
SA 25 ..... 90
SA 25 ..... 1253)
220 SA 25 ..... 1803)
1) Infinitely adjustable 3) Non self locking
2) At 50 Hz

We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

30
Technical Data SA3-SA100
Open-Close duty
1)
Tripping Torque Auma India Valve Stem dia. Permissible Revolutions Hand Hand wheel Weight
Actuator Type Mounting Output drive Thrust for for wheel Ratio Auma India Norm
both directions Flange Type-A Type-A Full stroke Dia.
Type Output Speed Standard Std. Std. With bevel Std. With bevel
DIN:3210 gear set gear set
Min. Max. 2) (Special
Max.
Nm. Nm. 1/min ISO:5210) kN Min. / Max. Kgs. Kgs.
SA 30 ..... 4
SA 30 ..... 5.6
SA 30 ..... 8
SA 30 ..... 11
SA 30 ..... 16
.....
1-480
SA 30 22
100 300 ..... G 12 52 120 or 360 1:1 3:1 72 88
SA 30 32
SA 30 ..... 45 (F14) 1-4800
SA 30 ..... 63
SA 30 ..... 90
SA 30 ..... 125 3)
264 SA 30 ..... 180 3)
SA 50 ..... 4
SA 50 ..... 5.6
SA 50 ..... 8
SA 50 ..... 11
SA 50 ..... 16 1-480
SA 50 ..... 22 75
100 500 G 12 52 160 or 640 1:1 3:1 92
SA 50 ..... 32
(F14) 1-4800
SA 50 ..... 45
SA 50 ..... 63
SA 50 ..... 90
SA 50 ..... 1253)
450 SA 50 ..... 1803)
SA 60 ..... 4
SA 60 ..... 5.6
SA 60 ..... 8
SA 60 ..... 11
SA 60 ..... 16
..... 1-480
SA 60 22
100 600 ..... G 12 52 160 or 640 1:1 3:1 75 92
SA 60 32
SA 60 ..... 45 (F14) 1-4800
SA 60 ..... 63
SA 60 ..... 90
SA 60 ..... 1253)
540 SA 60 ..... 1803)
SA 100 ..... 4
SA 100 ..... 5.6
SA 100 ..... 8
SA 100 ..... 11
SA 100 ..... 16
..... 1-480
SA 100 22
200 1000 SA 100 ..... 32 G3 65 190 or 800 1:1 4:1 107 128
SA 100 ..... 45 (F16) 1-4800
SA 100 ..... 63
SA 100 ..... 90
SA 100 ..... 1253)
900 SA 100 ..... 1803)

Enclosure : IP67 - IS:13947


o
Actuators are rated for short time duty S2-15min, based on 40 C ambient temperature. The nominal current
is based on an average load of approximately 35% of max. torque. The max. torque can be utilised for a short
time (e.g. to seat or unseat a valve) and the current can rise to max. value. Refer corresponding column for
current at max. torque in Electrical Data.

1) Infinitely adjustable 2) At 50 Hz 3) Non self locking


We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

31
Electrical Data SA3-SA100
Open-Close duty
Auma India
Three phase Squirrel cage AC Motor 415V, 50 Hz
Actuator Type
Torque
Max. Type Output Speed Nominal Speed Size Nominal Current at Starting Power Full load
at 50 Hz Output 1/min Current Max. Torque Current Factor Efficiency
Nm 1/min KW A 1) A A Cos o (%)
SA 3 ..... 11 0.06 1400 71 0.3 0.30 1.2 0.6 46
SA 3 ..... 16 0.06 1400 71 0.3 0.38 1.2 0.6 46
SA 3 ..... 22 0.06 1400 71 0.3 0.50 1.2 0.6 46
SA 3 ..... 32 0.12 1400 71 0.5 0.62 2.3 0.6 55
SA 3 ..... 45 0.18 2800 71 0.6 0.84 3.3 0.7 60
30
SA 3 ..... 63 0.18 2800 71 0.6 1.16 3.3 0.7 60
SA 3 ..... 90 0.37 2800 71 1.0 1.62 5.5 0.76 68
SA 3 ..... 125 0.37 2800 71 1.0 1.40 5.5 0.76 68
SA 3 ..... 180 0.37 2800 71 1.0 2.05 5.5 0.76 68
SA 6 ..... 4 0.06 1400 71 0.3 0.25 1.2 0.6 46
SA 6 ..... 5.6 0.06 1400 71 0.3 0.30 1.2 0.6 46
SA 6 ..... 8 0.06 1400 71 0.3 0.38 1.2 0.6 46
SA 6 ..... 11 0.12 1400 71 0.5 0.45 2.3 0.6 55
SA 6 ..... 16 0.12 1400 71 0.5 0.62 2.3 0.6 55
60 SA 6 ..... 22 0.12 1400 71 0.5 0.90 2.3 0.6 55
SA 6 ..... 32 0.18 2800 71 0.6 1.18 3.3 0.7 60
SA 6 ..... 45 0.37 2800 71 1.0 1.62 5.5 0.76 68
SA 6 ..... 63 0.37 2800 71 1.0 2.34 5.5 0.76 68
SA 6 ..... 90 0.55 2800 71 1.8 3.08 9.0 0.62 70
SA 6 ..... 125 0.55 2800 71 1.8 2.45 9.0 0.62 70
55 ..... 1.8 3.52 9.0 0.62 70
SA 6 180 0.55 2800 71
SA 12 ..... 4 0.06 1400 71 0.3 0.38 1.2 0.6 46
SA 12 ..... 5.6 0.12 1400 71 0.5 0.46 2.3 0.6 55
SA 12 ..... 8 0.12 1400 71 0.5 0.62 2.3 0.6 55
SA 12 ..... 11 0.12 1400 71 0.5 0.90 2.3 0.6 55
SA 12 ..... 16 0.25 1400 71 1.4 1.45 4.6 0.5 50
120
SA 12 ..... 22 0.25 1400 71 1.4 1.80 4.6 0.5 50
SA 12 ..... 32 0.37 2800 71 1.0 2.42 5.5 0.76 68
SA 12 ..... 45 0.55 2800 71 1.8 3.08 9.0 0.62 70
SA 12 ..... 63 1.1 2800 71 2.9 4.58 16.0 0.72 72
SA 12 ..... 90 1.1 2800 71 2.9 6.50 16.0 0.72 72
SA 12 ..... 125 1.1 2800 71 2.9 5.10 16.0 0.72 72
110 ..... 2.9 7.50 16.0 0.72 72
SA 12 180 1.1 2800 71
SA 15 ..... 4 0.06 1400 71 0.3 0.45 1.2 0.6 46
SA 15 ..... 5.6 0.12 1400 71 0.5 0.55 2.3 0.6 55
SA 15 ..... 8 0.12 1400 71 0.5 0.83 2.3 0.6 55
SA 15 ..... 11 0.25 1400 71 1.4 1.36 4.6 0.5 50
150 SA 15 ..... 16 0.25 1400 71 1.4 1.66 4.6 0.5 50
SA 15 ..... 22 0.37 2800 71 1.0 2.00 5.5 0.76 68
SA 15 ..... 32 0.55 2800 71 1.8 2.75 9.0 0.62 70
SA 15 ..... 45 1.1 2800 71 2.9 4.26 16.0 0.72 72
SA 15 ..... 63 1.1 2800 71 2.9 5.67 16.0 0.72 72
SA 25 ..... 4 0.12 1400 71 0.5 0.65 2.3 0.6 55
SA 25 ..... 5.6 0.25 1400 71 1.4 1.29 4.6 0.5 50
SA 25 ..... 8 0.55 1400 71 2.8 1.64 12.0 0.51 60
250 SA 25 ..... 11 0.55 1400 71 2.8 1.92 12.0 0.51 60
SA 25 ..... 16 0.55 1400 71 2.8 2.60 12.0 0.51 60
SA 25 ..... 22 0.55 1400 71 2.8 3.58 12.0 0.51 60
SA 25 ..... 32 1.1 2800 71 2.9 4.75 16.0 0.72 72
SA 25 ..... 45 1.1 2800 71 2.9 6.58 16.0 0.72 72
SA 25 ..... 63 2.2 2800 90 4.6 8.44 40.0 0.83 80
SA 25 ..... 90 2.2 2800 90 4.6 12.5 40.0 0.83 80
SA 25 ..... 125 2.2 2800 90 4.6 8.95 40.0 0.83 80
220 SA 25 ..... 180 2.2 2800 90 4.6 13.6 40.0 0.83 80

1) Current at max. torque. We recommend to select switch gear and cables suitable for those values.

We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

32
Electrical Data SA3-SA100
Open-Close duty
Auma India
Three phase Squirrel cage AC Motor 415V, 50 Hz
Actuator Type
Torque
Type Output Speed Nominal Speed Size Nominal Current at Starting Power Full load
Max.
at 50 Hz Output 1/min Current Max. Torque Current Factor Efficiency
Nm 1/min KW A 1) A A Cos o (%)
SA 30 ..... 4 0.12 1400 71 0.5 0.82 2.3 0.6 55
SA 30 ..... 5.6 0.25 1400 71 1.4 1.39 4.6 0.5 50
SA 30 ..... 8 0.55 1400 71 2.8 1.77 12.0 0.51 60
SA 30 ..... 11 0.55 1400 71 2.8 2.20 12.0 0.51 60
SA 30 ..... 16 0.55 1400 71 2.8 3.08 12.0 0.51 60
300
SA 30 ..... 22 1.1 1400 90 3.7 3.95 25.0 0.58 72
SA 30 ..... 32 1.1 2800 71 2.9 5.72 16.0 0.72 72
SA 30 ..... 45 1.25 2800 90 2.7 8.65 22.0 0.81 79
SA 30 ..... 63 2.2 2800 90 4.6 10.0 40.0 0.83 80
SA 30 ..... 90 2.5 2800 90 5.3 15.5 40.0 0.83 79
SA 30 ..... 125 2.5 2800 90 5.3 11.5 40.0 0.83 79
264 ..... 10.2 16.5 65.0 0.7 78
SA 30 180 4.0 2800 90
SA 50 ..... 4 0.25 1400 71 1.4 1.48 4.6 0.5 50
SA 50 ..... 5.6 0.55 1400 71 2.8 1.95 12.0 0.51 60
SA 50 ..... 8 0.55 1400 71 2.8 2.60 12.0 0.51 60
SA 50 ..... 11 0.55 1400 71 2.8 3.58 12.0 0.51 60
SA 50 ..... 16 1.1 1400 90 3.7 4.80 25.0 0.58 72
500 ..... 3.7 6.65 25.0 0.58 72
SA 50 22 1.1 1400 90
SA 50 ..... 32 2.2 2800 90 4.6 8.52 40.0 0.83 80
SA 50 ..... 45 2.2 2800 90 4.6 12.5 40.0 0.83 80
SA 50 ..... 63 4.0 2800 90 10.2 17.1 65.0 0.7 78
SA 50 ..... 90 4.0 2800 90 10.2 26.0 65.0 0.7 78
SA 50 ..... 125 5.0 2800 112 9.9 18.2 80.0 0.86 88
450 SA 50 ..... 180 5.0 2800 112 9.9 28.5 80.0 0.86 50
SA 60 ..... 4 0.25 1400 71 1.4 1.67 4.6 0.55 50
SA 60 ..... 5.6 0.55 1400 71 2.8 2.2 12.0 0.51 60
SA 60 ..... 8 0.55 1400 71 2.8 3.08 12.0 0.51 60
SA 60 ..... 11 0.55 1400 71 2.8 5.15 12.0 0.51 60
SA 60 ..... 16 1.1 1400 90 3.7 5.75 25.0 0.58 72
600 ..... 6.9 7.92 40.0 0.63 72
SA 60 22 2.2 1400 90
SA 60 ..... 32 2.2 2800 90 4.6 10.04 40.0 0.83 80
SA 60 ..... 45 4.0 2800 90 10.2 15.05 65.0 0.7 78
SA 60 ..... 63 4.0 2800 90 10.2 21.08 65.0 0.7 78
SA 60 ..... 90 5.0 2800 112 9.9 31.08 80.0 0.86 88
SA 60 ..... 125 5.0 2800 112 9.9 22.5 80.0 0.86 88
540 SA 60 ..... 180 5.0 2800 112 9.9 35.5 80.0 0.86 88
SA 100 ..... 4 0.55 1400 71 2.8 2.55 12.0 0.51 60
SA 100 ..... 5.6 0.55 1400 71 2.8 3.85 12.0 0.51 60
SA 100 ..... 8 0.75 1400 90 2.0 4.65 12.0 0.72 75
SA 100 ..... 11 1.1 1400 90 3.7 6.65 25.0 0.58 72
SA 100 ..... 16 2.2 1400 90 6.9 9.06 40.0 0.63 72
1000 ..... 6.9 12.5 40.0 0.63 72
SA 100 22 2.2 1400 90
SA 100 ..... 32 4.0 2800 90 10.2 17.5 65.0 0.7 78
SA 100 ..... 45 4.0 2800 90 10.2 26.0 65.0 0.7 78
SA 100 ..... 63 7.5 2800 112 15.6 40.0 116.0 0.78 86
SA 100 ..... 90 7.5 2800 112 15.6 60.0 116.0 0.78 86
SA 100 ..... 125 7.5 2800 112 15.6 44.6 116.0 0.78 86
900 SA 100 ..... 180 7.5 2800 112 15.6 68.0 116.0 0.78 86

Permissible voltage variation : + 10%, Permissible frequency variation : + 5%, Permissible combined variation : 10%
if voltage drops below there will be reduction of nominal output.
Auma motors are provided with 3 thermoswitches one in each winding connected in series to protect windings. Our
warranty is void if those thermoswitches are not connected in control circuit.
Motor data are approximate. Due to usual manufacturing tolerances there may be deviations from the values given.

1) Current at max. torque. We recommend to select switch gear and cables suitable for those values.
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

33
Technical Data SAR6-SAR100
Regulating duty
1)
Tripping Regu- Auma India No. of Valve Stem dia. Permissible Hand Hand wheel Weight
Torque lating Actuator Type starts Mounting Output drive Thrust for wheel Ratio Auma India Norm
in both Torque Flange Type-A Type-A Dia.
Type Output Speed Standard Std. Std. With bevel Std. With bevel
directions DIN:3210
2) Max. gear set gear set
Min. Max. Max. (Special
Nm Nm Nm 1/min c/h ISO:5210) Max. mm Max. kN Kgs. Kgs.
SAR 6 ..... 4
SAR 6 ..... 5.6
SAR 6 ..... 8
SAR 6 ..... 11 G0
30 60 30 SAR 6 ..... 16 1200 26 40 250 1:1 2:1 39 45
SAR 6 ..... 22
(F10)
SAR 6 ..... 32
SAR 6 ..... 45
SAR 12 ..... 4
SAR 12 ..... 5.6
SAR 12 ..... 8
SAR 12 ..... 11 G0
60 120 60 ..... 1200
38 60 250 1:1 2:1 39 45
SAR 12 16 (F10)
SAR 12 ..... 22
SAR 12 ..... 32
SAR 12 ..... 45 900
SAR 15 ..... 4
SAR 15 ..... 5.6
SAR 15 ..... 8
.....
G0
60 150 75 SAR 15 11 1200 38 60 250 1:1 2:1 39 45
SAR 15 ..... 16 (F10)
SAR 15 ..... 22
SAR 15 ..... 32
SAR 25 ..... 4
SAR 25 ..... 5.6
SAR 25 ..... 8
SAR 25 ..... 11 1200 G 12
120 250 120 SAR 25 ..... 16 52 120 360 1:1 3:1 72 88
25 ..... 22
(F14)
SAR 900
SAR 25 ..... 32
SAR 25 ..... 45 600
SAR 30 ..... 4
SAR 30 ..... 5.6
SAR 30 ..... 8 1200
SAR 30 ..... 11 G 12
150 300 150 SAR 30 ..... 16 52 120 360 1:1 3:1 72 88
SAR 30 ..... 22 (F14)
SAR 30 ..... 32 600
SAR 30 ..... 45
SAR 50 ..... 4
SAR 50 ..... 5.6 1200
SAR 50 ..... 8
..... 900
SAR 50
.....
11 G 12
250 500 250 SAR 50 16 52 160 640 1:1 3:1 75 92
SAR 50 ..... 22 (F14)
SAR 50 ..... 32 600
SAR 50 ..... 45
SAR 60 ..... 4
SAR 60 ..... 5.6 1200
SAR 60 ..... 8 G 12
300 600 300 SAR 60 ..... 16 52 160 640 1:1 3:1 75 92
.....
(F14)
SAR 60 22 600
SAR 60 ..... 32
SAR 100 ..... 4 1200
SAR 100 ..... 5.6 900
SAR 100 ..... 8 G3
500 1000 500 SAR 100 ..... 11 65 190 800 1:1 4:1 107 128
..... (F16)
SAR 100 16 600
SAR 100 ..... 22

Enclosure : IP67 - IS:13947


Actuators are rated for Intermittent duty S - 25% ED, based on 40o C ambient temperature. The nominal current is based
on an average load of approximately 35% of max. torque. The max. torque can be utilised for a short time (e.g. to seat
or unseat a valve) and the current can rise to max. value. Refer corresponding column for current at max. torque in
Electrical Data.

1) Infinitely adjustable 2) At 50 Hz
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

34
Electrical Data SAR6-SAR100
Regulating duty
Auma India
Regulating Torque Three phase Squirrel cage AC Motor 415V, 50 Hz
Actuator Type
Type Output Speed Nominal Speed Size Nominal Current at Starting Power Full load
Max. at 50 Hz Output 1/min Current Max. Torque Current Factor Efficiency
Nm 1/min KW A 1) A A Cos o (%)
SAR 6 ..... 4 0.06 1400 71 0.3 0.25 1.2 0.6 46
SAR 6 ..... 5.6 0.06 1400 71 0.3 0.30 1.2 0.6 46
SAR 6 ..... 8 0.06 1400 71 0.3 0.38 1.2 0.6 46
SAR 6 ..... 11 0.12 1400 71 0.5 0.45 2.3 0.6 55
SAR 6 ..... 16 0.12 1400 71 0.5 0.62 2.3 0.6 55
30 SAR 6 ..... 22 0.12 1400 71 0.5 0.90 2.3 0.6 55
SAR 6 ..... 32 0.25 1400 71 1.4 1.45 4.6 0.5 50
SAR 6 ..... 45 0.25 1400 71 1.4 1.86 4.6 0.5 50
SAR 12 ..... 4 0.06 1400 71 0.3 0.38 1.2 0.6 46
SAR 12 ..... 5.6 0.12 1400 71 0.5 0.46 2.3 0.6 55
SAR 12 ..... 8 0.12 1400 71 0.5 0.62 2.3 0.6 55
SAR 12 ..... 11 0.12 1400 71 0.5 0.90 2.3 0.6 55
60 .....
SAR 12 16 0.25 1400 71 1.4 1.45 4.6 0.5 50
SAR 12 ..... 22 0.25 1400 71 1.4 1.80 4.6 0.5 50
SAR 12 ..... 32 0.55 1400 71 2.8 2.52 12.0 0.51 60
SAR 12 ..... 45 0.55 1400 71 2.8 3.52 12.0 0.51 60
SAR 15 ..... 4 0.06 1400 71 0.3 0.45 1.2 0.6 46
SAR 15 ..... 5.6 0.12 1400 71 0.5 0.55 2.3 0.6 55
SAR 15 ..... 8 0.12 1400 71 0.5 0.83 2.3 0.6 55
75 SAR 15 ..... 11 0.25 1400 71 1.4 1.36 4.6 0.5 50
SAR 15 ..... 16 0.25 1400 71 1.4 1.66 4.6 0.5 50
SAR 15 ..... 22 0.55 1400 71 2.8 2.20 12.0 0.51 60
SAR 15 ..... 32 0.55 1400 71 2.8 3.08 12.0 0.51 60
SAR 25 ..... 4 0.12 1400 71 0.5 0.65 2.3 0.6 55
SAR 25 ..... 5.6 0.25 1400 71 1.4 1.29 4.6 0.5 50
SAR 25 ..... 8 0.25 1400 71 1.4 1.64 4.6 0.5 50
SAR 25 ..... 11 0.55 1400 71 2.8 1.92 12.0 0.51 60
125 SAR 25 ..... 16 0.55 1400 71 2.8 2.60 12.0 0.51 60
SAR 25 ..... 22 0.55 1400 71 2.8 3.58 12.0 0.51 60
SAR 25 ..... 32 1.1 1400 90 3.7 4.80 25.0 0.58 72
SAR 25 ..... 45 1.1 1400 90 3.7 6.67 25.0 0.58 72
SAR 30 ..... 4 0.12 1400 71 0.5 0.82 2.3 0.6 55
SAR 30 ..... 5.6 0.25 1400 71 1.4 1.39 4.6 0.5 50
SAR 30 ..... 8 0.25 1400 71 1.4 1.77 4.6 0.5 50
SAR 30 ..... 11 0.55 1400 71 2.8 2.20 12.0 0.51 60
150 .....
SAR 30 16 0.55 1400 71 2.8 3.08 12.0 0.51 60
SAR 30 ..... 22 1.1 1400 90 3.7 3.95 25.0 0.58 72
SAR 30 ..... 32 1.1 1400 90 3.7 5.75 25.0 0.58 72
SAR 30 ..... 45 2.2 1400 90 6.9 8.0 40.0 0.63 72
SAR 50 ..... 4 0.25 1400 71 1.4 1.48 4.6 0.5 50
SAR 50 ..... 5.6 0.55 1400 71 2.8 1.95 12.0 0.51 60
SAR 50 ..... 8 0.55 1400 71 2.8 2.60 12.0 0.51 60
SAR 50 ..... 11 0.55 1400 71 2.8 3.58 12.0 0.51 60
250 .....
SAR 50 16 1.1 1400 90 3.7 4.80 25.0 0.58 72
SAR 50 ..... 22 1.1 1400 90 3.7 6.65 25.0 0.58 72
SAR 50 ..... 32 2.2 1400 90 6.9 9.06 40.0 0.63 72
SAR 50 ..... 45 2.2 1400 90 6.9 13.4 40.0 0.63 72
SAR 60 ..... 4 0.25 1400 71 1.4 1.67 4.6 0.5 50
SAR 60 ..... 5.6 0.55 1400 71 2.8 2.2 12.0 0.51 60
SAR 60 ..... 8 0.55 1400 71 2.8 3.08 12.0 0.51 60
300 SAR 60 ..... 16 1.1 1400 90 3.7 5.75 25.0 0.58 72
SAR 60 ..... 22 2.2 1400 90 6.9 7.92 40.0 0.63 72
SAR 60 ..... 32 2.2 1400 90 6.9 11.1 40.0 0.63 72
SAR 100 ..... 4 0.55 1400 71 2.8 2.55 12.0 0.51 60
SAR 100 ..... 5.6 0.55 1400 71 2.8 3.85 12.0 0.51 60
SAR 100 ..... 8 0.75 1400 90 2.0 4.65 12.0 0.72 75
500 SAR 100 ..... 11 1.1 1400 90 3.7 6.65 25.0 0.58 72
SAR 100 ..... 16 2.2 1400 90 6.9 9.06 40.0 0.63 72
SAR 100 ..... 22 2.2 1400 90 6.9 12.5 40.0 0.63 72
Permissible voltage variation : + 10%, Permissible frequency variation : + 5%, Permissible combined variation : 10%
if voltage drops below there will be reduction of nominal output.
Auma motors are provided with 3 thermoswitches one in each winding connected in series to protect windings. Our
warranty is void if those thermoswitches are not connected in control circuit.
Motor data are approximate. Due to usual manufacturing tolerances there may be deviations from the values given.
1) Current at Max. torque. We recommend to select switch gear and cables suitable for those values.
We reserve the right to alter data according to improvements made. Previous data sheets become invalid with the issue of this data sheet.

35
SA3-SA100
Norm actuator SAR6-SAR100

SA3 & SA6 SA12 & SA15 SA25 & SA30 SA50 & SA60 SA100
Dimensions SAR6 SAR12 & SAR15 SAR25 & SAR30 SAR50 & SAR60 SAR100
A 215 215 245 245 275
B 257 257 282 282 307
C 210 235 275 275 380
D 250 250 360 640 800
D1 110 - 125 110 - 125 110 - 160 125 - 160 125 - 200
D2 42 x 3.3 60 x 3.7 76 x 3.7 76 x 3.7 89 x 4.1
E 195 195 255 255 255
J 185 185 210 210 230
L max. 175-230 175-230 175-280 210-280 210-305
LL min. 35 35 45 45 60
M min. 80 80 80 80 80
N 110 110 170 170 210
O 96 96 96 96 96
P 142 142 167 167 192
Q min 65 65 65 65 65
R (Conduit th) 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC
S 255 255 255 255 255
Y 182 185 250 250 306
d 125 125 175 175 210
g (TYPE - A) 35 37 51 51 69
g1 (TYPE - B & C) 50 50 65 65 80
g2 ( TYPE - D & E) 15 15 22 22 30
DIN 3210 Designation G0 G0 G1 2 G1 2 G3

We reserve the right to alter data, dimensions and weights according to improvement made. (all dimensions are in mm)
Figures and diagrams are not binding.

36
SA3-SA100
Integral starter compact actuator SAR6-SAR100

SA3 & SA6 SA12 & SA15 SA25 & SA30 SA50 & SA60 SA100
Dimensions SAR6 SAR12 & SAR15 SAR25 & SAR30 SAR50 & SAR60 SAR100
A 215 215 245 245 275
B 430 430 451 451 467
C 210 235 275 275 380
D 250 250 360 640 800
D1 110 - 125 110 - 125 110 - 160 125 - 160 125 - 200
D2 42 x 3.3 60 x 3.7 76 x 3.7 76 x 3.7 89 x 4.1
E 195 195 255 255 255
J 185 185 210 210 230
K 342 342 342 342 342
L max. 340 340 450 450 515
LL min. 35 35 45 45 60
M min. 80 80 80 80 80
N 227 227 227 227 227
O 96 96 96 96 96
P 315 315 340 340 365
Q min 65 65 65 65 65
R (Conduit th) 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC
S 255 255 255 255 255
V 160 160 160 160 160
W 185 185 185 185 185
d 125 125 175 175 210
g (TYPE - A) 35 37 51 51 69
g1 (TYPE - B & C) 50 50 65 65 80
g2 ( TYPE - D & E) 15 15 22 22 30
DIN 3210 Designation G0 G0 G 12 G 12 G3

We reserve the right to alter data, dimensions and weights according to improvement made. (all dimensions are in mm)
Figures and diagrams are not binding.

37
SA3-SA100
Integral starter epac actuator SAR6-SAR100

e-pac

e-pac

e-pac

SA3 & SA6 SA12 & SA15 SA25 & SA30 SA50 & SA60 SA100
Dimensions SAR6 SAR12 & SAR15 SAR25 & SAR30 SAR50 & SAR60 SAR100
A 215 215 245 245 275
B 278.5 278.5 303.5 303.5 329.5
C 210 235 275 325 380
D 250 250 360 640 800
D1 110 - 125 110 - 125 110 - 160 125 - 160 125 - 200
D2 42 x 3.3 60 x 3.7 76 x 3.7 76 x 3.7 89 x 4.1
E 195 195 255 255 255
J 185 185 210 210 230
K 256 256 256 256 256
L max 340 340 450 450 515
LL min. 35 35 45 45 60
M min. 80 80 80 80 80
N 240.5 240.5 240.5 240.5 240.5
O 96 96 96 96 96
P 400.5 400.5 425.5 425.5 451.5
Q min 65 65 65 65 65
R (Conduit th) 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC 2x114 '' BSC
S 255 255 255 255 255
V 185 185 185 185 185
W 175 175 175 175 175
Z (For ON-OFF Duty) 121 121 121 121 121
Z1 (For Regulating Duty) 202 202 202 202 202
d 125 125 175 175 210
g (TYPE - A) 35 37 51 51 69
g1 (TYPE - B & C) 50 50 65 65 80
g2 ( TYPE - D & E) 15 15 22 22 30
DIN 3210 Designation G0 G0 G 12 G 12 G3
We reserve the right to alter data, dimensions and weights according to improvement made. (all dimensions are in mm)
Figures and diagrams are not binding.

38
SA3-SA100
Output drives according to DIN 3210 SAR6-SAR100
SA3/ SA12/ SAR12/ SA25/ SAR25/ SA50/ SAR50/ SA100/
SAR 6
SA6 SA15 SAR15 SA30 SAR30 SA60 SAR60 SAR100

39
SA6-SA100
Linear Thrust Unit for control valves with
LTU6-LTU100

For all other dimensions of actuator, please refer separate data sheet (all dimensions are in mm)

Dimensions LTU6 LTU12 LTU25 LTU50 LTU100


SA / SAR6 SA / SAR12 SA / SAR25 SA / SAR50 SA / SAR100
Stroke (L) mm 50 100 60 120 80 160 80 160
Thrust max. kN 20 35 63 100
Thrust max. kN
10 18 31.5 50
for Regulating
Stem thread, LH Tr. 24x5 Tr. 32x6 Tr. 40x7 Tr. 50x8
A 150 200 155 215 219 299 219 299
B 60 70 101 101
C 25 30 55 55
D 70 70 100 100
E 125 125 175 175
F 15 15 16 16
G M10 M10 M16 M16
H 3 3 4 4
J 102 102 140 140
K M16x1.5 M20x1.5 M36x3 M36x3

40
Terminal plan - Norm actuator

DSR Torque switch, closing, clockwise rotation


DOL Torque switch, opening, anti-clockwise rotation
WSR Limit switch, closing, clockwise rotation
WOL Limit switch, opening, anti-clockwise rotation
DSR1
DOL1 } Torque switch in tandem operation
with DSR/DOL
WSR1
WOL1 } Limit switch in tandem operation
with WSR/WOL
Th Thermo switch
b1 Push button for stop
b2 Push button for close
b3 Push button for open
C1 Contactor-close
C2 Contactor-open
e4 Thermal overload relay
e5 Control fuse
h1 Indicator lamp-close
h2 Indicator lamp-open
h3 Indicator lamp-trouble
M Motor (3Phase AC) 415V, 3 , 50Hz
a1 Main switch
SH Space heater
b4 Selector switch
N Neutral
E Earth
R,S,T(L1,L2,L3) Phases
e1-e3 Main fuse
A Auto
m Manual

41
Wiring diagram - Integral starter, epac

42
Info-A

Legend - Integral starter, epac


Collective fault indication for Display board legend:-
- Thermoswitch trip Symbol Type Description Symbol Type Description
- Torque switch trip
Status Actuator in open direction Fault Torque switch open
Info-B
Potential free contact Local-Off-Remote
Status Actuator in Close direction Fault Torque switch close

Status Limit switch open Fault Thermoswitch trip

Status Limit switch close Fault Thermal overload relay trip


K1 - Open Contactor
K2 - Close Contactor Status Actuator in local mode Fault Fault indication
Th - Thermoswitch
Status Actuator in remote mode Fault Single phasing
RL1 - 24V DC Relay for OPEN Contactor
RL2 - 24V DC Relay for CLOSE Contactor
Status 11V Internal power supply
RL3 - 24V DC Relay for FAULT Annunciation
C8M-C8F - 64 Pin Male-Female connector
Status 23V Internal power supply
C15M-C15F - 24 Pin Rack & panel Male-Female connector
M - Motor 3Ph, 415V, 50Hz.
Status 24V DC For Customer's use
DSR - Close torque switch
DOL - Open torque switch
Dip switch particulars:-
WSR - Close limit switch
WOL - Open limit switch Switch Switch position Switch position
Remarks
No OFF ON
DSR1/DOL1 - Torque switch in tandem operation with DSR/DOL
1 Inching operation in Local mode Non-inching operation in Local mode Applicable
WSR1/WOL1 - Limit switch in tandem operation with WSR/WOL (non self retaining) (self retaining)
F,G - Plug in type terminals between basic actuator(Norm) 2 Emergency shut down to Open Not-Applicable
and Integral starter(epac) 3 Emergency shut down to Close Not-Applicable
R,Y,B - Main supply 415V, 3o, 50Hz, AC Supply 4 Timer board operation enabled Timer board operation disenabled Not-Applicable
A,B,C - Motor terminals 5 Inhibit Open direction Not-Applicable
L 1-27 - Terminals for customer's connections 6 Inhibit Close direction Not-Applicable
SH - Space heater Inching operation in Remote Non-Inching operation in Remote mode
7 mode (non self retaining) Applicable
(self retaining)
43

8 Limit switch close bypass


(Closing by torque switch Close) Limit Seating Applicable
(Torque Seating)
automates valves

auma india norm auma india e-pac


SA3 - SA100 SA3 - SA100
SAR6 - SAR100 SAR6 - SAR100
Output torque from 30 to 1000 Nm Output torque from 30 to 1000 Nm

Worm Gear Boxes Bevel Gear Boxes Worm Gear Boxes


GS 40.2-GS 125.2 GK 10.2-GK 35.1 GF 40.2-GF 250
Output torque from 300 to 5600 Nm Output torque from 120 to 8000 Nm Output torque from 300 to 45000 Nm

Worm Gear Boxes Spur Gear Boxes


GS 160-GS 500 GST 12-GST 1600
Output torque from 8000 to 360000 Nm Output torque from 120 to 16000 Nm

Head Office and Works Branch Office Branch Office


AUMA (INDIA) LIMITED AUMA (INDIA) LIMITED AUMA (INDIA) LIMITED
Plot No. 39-B, II Phase 8-C, Block B-H,Munirka "Kalpadrum", 12, Pandurang Colony
Peenya Industrial Area NEW DELHI - 110 067. Behind New Karnataka High School
Bangalore - 560 058. Erandwana, Pune - 411 038.
Ph : 080-8394365 Ph : 011-26187063 Ph : 020-25410465
080-8394366
080-8392808
Fax : 080-8392809 Fax : 011-26109637 Fax : 020-25443186
E-mail : info@auma.co.in E-mail : aumandl@vsnl.net E-mail : aumapn@pn3.vsnl.net.in
DD / CT 001 issue 10/02