Anda di halaman 1dari 1

MIDAS/Gen

RC Column Design Result Output

Company
Arnel Aguel

Author

Project Title

12-STOREY CONDOMINIUM

File Name

C:\...\RC Seismic Design.mgb


z

Design Code

: ACI318-02

Unit System

: kN, m
0.762

1. Design Condition

Member Number: 63 (PM), 996 (Shear)

Column Height : 4.8768 m


Section Property: Interior Column (No : 2)
Rebar Pattern

: fc = 27579, fy = 413686, fys = 275790 KPa


0.0762

Material Data

0.762

: 16 - 5 - #7
Total Rebar Area Ast = 0.00619354 m (Rhost = 0.011)

2. Applied Loads
Load Combination :

AT (I) Point

Pu

= 5429.91 kN

Mcy

= 206.879,

Mcz

= -1.2533 kN-m

Mc

= SQRT(Mcy+ Mcz)

= 206.883 kN-m

3. Axial Forces and Moments Capacity Check


Concentric Max. Axial Load PhiPn-max

= 8334.85 kN

Axial Load Ratio

Pu/PhiPn

= 5429.91 / 8334.85

= 0.651 < 1.000 ....... O.K

Moment Ratio

Mc/PhiMn

= 206.883 / 363.415

= 0.569 < 1.000 ....... O.K

Mcy/PhiMny = 206.879 / 363.408

= 0.569 < 1.000 ....... O.K

Mcz/PhiMnz = -1.2533 / 2.28768

= 0.548 < 1.000 ....... O.K

4. P-M Interaction Diagram

PhiPn(kN)

P(kN)
16681

10418.56
Theta=0.36Deg.
N.A=0.20Deg.

PhiMn(kN-m)
0.00

8769.74

528.43

7548.85

812.97

6415.11

994.76

10676

5397.43

1102.65

8674

4553.68

1161.38

4061.77

1186.25

3910.18

1234.96

3567.59

1320.42

3088.95

1426.76

14679
12677

8335

(8335,363)

6672
(5430,207)

4671
2669
667

1726.70

M(kN-m)

-1334

-60.67

0.00

2260

2034

1808

1582

1356

904

678

452

226

1130

-2305.96

-3336

1195.36
730.82

5. Shear Force Capacity Check


Applied Shear Strength
Design Shear Strength
Shear Ratio

Vu
= 1025.21 kN (Load Combination : 16)
PhiVc+PhiVs = 348.363 + 1367.27 = 1715.63 kN (As-H_req = 0.00477 m/m, 2-#3 @10 )
= 0.598 < 1.000 ....... O.K
Vu/PhiVn

Modeling, Integrated Design & Analysis Software

Print Date/Time : 06/10/2011 00:01

Anda mungkin juga menyukai