FORWEL
SPECIFICATIONS
AK-20V Welding Power Source Control Power Source Frequency Memory Retention Indication External Input (Dry contact or open collector) External Contact Output (250V 0.5A) AK-20H 220VAC and 440VAC +10%, -25% 110VAC 15% or 220VAC 15% [not changeover] 50/60Hz 10 years and over after power failure 7-segment LED, 6.5mm(W) x 10.0mm(H) Mode Switch1(MS1), Mode Switch2(MS2) Start1(FS1), Start2(FS2) Weld Trans or Thyristor Thermo Switch Valve1(SOL1), Valve2(SOL2), 110VAC or 220VAC
Relay Contact Output(1a1b), One Short(0.3sec)
Control Method : Phase control by thyristor Weld Current Weld Counter Control Angle : 20~160 Maximum Analyze : 0.1% (0.0~99.9%) 0~3999 Counts Weld Schedule Squeeze Time Up Slope Time Weld Time Cool Time Off Time Weld Current : : : : : : : 0~9 schedules 0~99 cycles 0~9 cycles 0~99 cycles 0~99 cycles 0~99 cycles 0.0~99.9%
Program Parameters
Ambient Temperature Storage Temperature Ambient Humidity Insulation Resistance Dielectric Strength Noise Strength Dimensions Power Consumption Weight
-10 to 55 C (at non-freezing status) -25 to 65 C (at non-freezing status) 35% to 85% RH Min. 100M(at 500VDC) 2000VAC 50/60Hz for 1minute 2kV the square wave noise(pulse width: 1s by the noise simulator) 76mm(W)x194mm(H)x190mm(D) 3.0"(W)x7.6"(H)x7.5"(D) 194mm(W)x76mm(H)x190mm(D) 7.6"(W)x3.0"(H)x7.5"(D) 2.0Kg (4.4lb)
OPERATION MODE
Operation Mode Spot/Projection Mode 2Head Spot/Portable Mode Seam/Roll-Spot Mode Butt Mode External Mode Switch MS1 OFF ON OFF ON MS2 OFF OFF ON ON Schedule 0~9 1 2 0~9 0~9 Start Switch1(FS1) Start Switch2(FS2) Remarks
FRONT VIEW
1 2 3 4 12 14 16 13 15
FORWEL
S UEE Q EZ
WL ED
CO OL
OF F
AT UO WL ED AT F N WL UO U ED MN C L TS A .CR ET
SOE LP
C RE T URN
IE TM
WL C UT ED ON IE TM E TR NE O /O F N F
WO E .P WR
TM EP
RAY ED
10
11
19
22
21
20
17 18
1 2 3 4 5 6 7 8
SQUEEZE : 0~99 cycles WELD : 0~99 cycles COOL : 0~99 cycles OFF : 0~99 cycles SLOPE(Weld Current Up Slope) : 0~9 cycles ** WELD CURRENT : 0.0~99.9% ITEM(Weld Schedule) : 0~9 schedules COUNT(Weld Count) : 0~3999 counts 9 9 9. = 1999 9 9.9. = 2999 9.9.9. = 3999
9 WELD POWER Lamp 10 TEMP(Thyristor Temperature Switch) Lamp 11 READY Lamp WELD POWER ON + TEMP ON + WELD ON = READY Lamp ON 12 AUTO/MAN(Auto/Manual) Lmap 13 WELD/TEST Lamp 14 AUTO/MAN(Auto/Manual) Button 15 WELD/TEST Button 16 FUN/C.CLR(Function/Weld Count Clear) Button 17 ENTER(Operation/Program) Button
** Slope(Up Slope)
Weld Time 0~99 cycles
18 19
20 + Button : Data increase 21 - Button : Data decrease Operation : Control Power OFF/ON Button 22 ITEM(Weld Schedule) Increment Button