In planning the building oI reinIorced concrete structural masonry wall is not taken into account,
because the main component in the structure oI the beams, plates, columns and Ioundations. In
Iact that happened on the Iield, when an earthquake which resulted in a greater lateral Iorce
against buildings. The masonry wall gives considerable inIluence on the stiIIness and strength oI
the structure, so the inIluence oI diIIerent portal opens its downIall. Analysis oI the power oI
reinIorced concrete building structures is done by using the ETABS program. With wall
openings without Iillers, Iull wall without openings, joist and the opening in the wall, past the
wall and window openings are also doors. As a result oI the earthquake Iorce magniIication oI
the beam shear Iorce at a meeting with a column oI 0.52 up to 37.85 percent. This is caused by
shortening the column shear Iorce resulting concentration at a meeting oI the beam with a
column that can lead to shear Iailure in columns.