ELECTRICAL MACHINE - II LAB SYLLABUS List of experiments: (To be performed minimum 10 experiments) Determination oI synchronous impedance oI alternator by open and short circuit test.
ELECTRICAL MACHINE - II LAB SYLLABUS List of experiments: (To be performed minimum 10 experiments) Determination oI synchronous impedance oI alternator by open and short circuit test.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai DOCX, PDF, TXT atau baca online dari Scribd
ELECTRICAL MACHINE - II LAB SYLLABUS List of experiments: (To be performed minimum 10 experiments) Determination oI synchronous impedance oI alternator by open and short circuit test.
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai DOCX, PDF, TXT atau baca online dari Scribd
List of experiments: (To be performed minimum 10 experiments)
1) Determination oI synchronous impedance oI alternator by open & short circuit test. 2) Determination oI Xd & Xq by slip circuit. 3) Determination oI Regulation oI a Three-Phase Alternator by Direct Loading. 4) Synchronizing oI Alternator by lamp method. 5) To determine regulation by MMF method. 6) Determine oI Potier Reactance Xp by Zero Power Factor Saturation curve. 7) Plotting oI V-curve oI synchronous Motor. 8) Determination oI mechanical losses oI 3-phase induction motor by no-load test. 9) Determination oI circuit parameter oI 3-phase induction motor by open & block rotor test. 10) Study oI Induction Motor Starters. 11) Measurement oI Speed oI Induction Motor by Measuring Rotor Frequency. 12) IdentiIication oI stator winding oI three-phase induction motor. 13) Study oI reversal 3-phase induction motor. 14) Study oI braking oI 3-phase induction motor. 15) EIIect oI variation oI rotor resistance on XS torque slip characteristics oI 3-phase induction motor. 16) To determine the negative sequence reactance oI a synchronous generator. 17) To determine the positive sequence reactance oI a synchronous generator. 18) Determination oI vector group oI a three-phase transIormer Ior zero degree phase displacement. 19) Determination oI vector group oI a three-phase transIormer Ior 180 phase displacement. 20) Determination oI vector group oI a three-phase transIormer Ior 30 and 30 phase displacement. Major equipment Required: 3-phase Alternators Resistive Load. 3-phase induction motor Single phase variac Three phase Variac Ammeter, Voltmeters, Wattmeters. Induction Motor. Starters ReIerence Book: Electrical machines, Nagrath and Kothari