NemioTM MX (SSA-590A) is a compact full-digital color diagnostic ultrasound system. This next-generation system has achieved high image quality and high sensitivity using advanced technologies. Superior imaging performance Nemio MX includes THI (Tissue Harmonic Imaging) in the standard configuration and generates high-quality B-mode images. Advanced DYNAMIC FLOWTM, which produces high-resolution blood flow images and is a feature of topof-the-line systems, and ApliPureTM, which is compounding technology for high contrast resolution, are supported. Thus, Nemio MX provides high-end imaging performance. Sophisticated ergonomics A 15-inch LCD monitor whose brightness has been adjusted appropriately for the display of ultrasound images is used in Nemio MX. The displayed images are easy-toview and their excellent visibility is relatively insensitive to the brightness of the room. A flexible multijoint arm supports the LCD monitor, allowing appropriate positioning for operations in the standing or sitting posture to be achieved easily. A lightweight body has been achieved through the use of the LCD monitor, making it much easier to move the system around in the hospital. Functions can be assigned freely to buttons on the operating panel to suit individual preferences. Also, operation protocols can be registered in advance, allowing examinations to be performed smoothly with simple operations (Sonoset). In addition, the B-mode image quality can be adjusted appropriately with a single operation using the IP dial or QuickScan. Efficient data management A large-capacity HDD is provided in the standard configuration, facilitating efficient management of acquired images. Filed images can be output via the USB port or stored on CD/DVD. DICOM is supported by the optional Advanced Data Management board. In addition, Stress Echo and the reporting function can be installed as options.

SyStEM MAtrix for SSA-590A


no. 1 Main unit unit model name SSA-590A remarks Including color Doppler, DVD drive, THI, PW, Sector, 15-inch LCD monitor, QuickScan, Sonoset PSP for 2D/CDI, QSP for CDI Enables CWD capabilities. Pencil transducer connector is included. Reference signal display unit + ECG cable PCG sensor Adds a 3rd transducer port. Foot SW + connector kit for Main unit. Data Management unit with filing, DICOM storage, and report functions Add QSP/PSP, 3rd transducer port, CW, Reference signal unit, Dynamic Flow and Directional Color Angio. ECG, CWD (without pencil transducer support). For digital printers Enables OB 4D scan using PVM-375MV. UIDM-590A, UIPS-590A, and UIQS-590A are required. For mounting a color printer or DVD recorder (with cables) For mounting a color printer and a DVD recorder (with cables) Enables directional display in Color Angio mode (Directional Color Angio). Enables trapezoid scan function. Enables High PRF PW Doppler.

<options> 2 B-PSP & CDI-PSP/QSP kit UIQS-590A 3 CW kit 4 Reference signal kit 5 6 7 8 9 Transducer selector M-TEE hanger kit Footswitch kit Gel warmer Data Management unit UICW-590A UJUR-590A UJUR-592A UIPS-590A UAEH-590A UZFS-590A UZGW-590A UIDM-590A UIUG-590A UICV-590A UZCA-590A UIMV-590A UZRI-590A UZRI-591A USDA-590A USTS-590A USHP-590A USTD-590A USHI-590A USTI-590A USAC-590A USDF-590A UDDS-590A UDSE-590A UDPA-590A

10 Premium kit 11 CV kit 12 Cable for printer 13 Mecha 4D kit Mounting kit for peripheral unit (for a single unit) Mounting kit for peripheral 15 unit (for 2 units) <optional software> 16 DCA kit 17 Trapezoid scan kit 18 HPRF kit 19 TDI kit 20 CHI/FEI kit 14 21 TIC kit 22 ACM kit 23 Dynamic Flow kit <options for uidm-590a> 24 DICOM system kit 25 Stress Echo kit 26 Panoramic View kit

Enables Time-Intensity Curve generation. USHI-590A is required. Automated Cardiac Flow Measurement

MPDUS0017EA

trANSDUcEr oPtioNS
model name PSM-20CT PSM-50AT PSM-70AT PSM-30BT PSM-37CT PEF-510MA PEF-704LA PVM-375AT PVM-672AT PVM-662AT PVM-651VT PVM-740RT PVM-787LA PVM-620ST PVF-620ST PVM-381AT PVF-381MT PVF-738H PVF-738F PVF-745V PVL-715RT PLM-503AT PLM-703AT PLM-805AT PLM-1202S PLM-1204AT PLF-308P PVM-375MV PC-19M PC-50V
*1: *2: *3 *4

scan type Sector 90 Sector 90 Sector 90 Sector 90 Sector 90 Sector 90 Linear 34 mm Convex 70 Convex 62 Convex 62 Convex 143 Convex 144 Convex 85 Convex 144 Convex 144 Convex 75 Convex 75 Convex 32 Convex 32 Convex 38 Linear 53 mm Convex R53 143 Linear 32 mm Linear 32 mm Linear 56 mm Linear 25 mm Linear 32 mm Linear 85 mm Convex Pencil Pencil

Freq. (mHz) 2.0 5.0 7.0 3.0 3.75 5.0 7.0 3.75 6.0 6.0 6.0 7.0 7.0 6.0 6.0 3.75 3.75 7.0 7.0 7.0 7.0 7.0 5.0 7.5 8.0 12.0 12.0 3.75 3.75 1.9 5.0 3.0 6.0 10.0 3.7 5.0 6.0 10.0 6.0 8.0 8.0 7.5 10.0 10.0 7.5 7.5 6.0 6.0 10.0 10.0 10.0 12.0 10.0 8.5 11.0 12.0 14.0 14.0 5.0 6.0

multi-freq. (mHz) B-mode tHi 2.5 4.5 7.5 3.0 4.2 5.0 7.5 4.2 7.0 7.0 6.0 7.5 7.5 6.0 6.0 3.7 3.7 7.5 7.5 7.5 9.0 7.5 7.2 9.0 9.0 12.0 12.0 4.0 4.2 2.0 3.7 5.0 2.0 3.2 3.7 5.0 3.0 5.7 5.7 5.0 5.0 5.0 4.0 4.0 3.0 3.0 5.0 5.0 5.0 6.0 5.0 6.0 6.0 6.0 8.0 8.0 3.0 3.0 3.8 6.0 4.0 4.8 6.0 5.0 8.0 10.0 4.8 4.8 9.0 11.0 12.0 5.0 3.6 5.6 3.6 4.6 5.6 4.6 6.5 8.0 4.6 4.6 7.0 9.0 10.0 4.6

application Transcranial Doppler (Pediatric) Heart Pediatric heart Adult heart Abdominal Multiplane TEE Laparoscopic Abdomen Neonatal head Neonatal head Endovaginal Endorectal Laparoscopic Endocavitary Endocavitary Adult heart, abdomen Adult heart, abdomen Intraoperative Abdominal, small parts Intraoperative Endorectal (Biplane) Vascular Carotid Small parts Small parts Intraoperative Small parts Abdominal biopsy OB fetus Heart Doppler Peripheral Vascular
*1 *1 *1

remarks

*4

*4 *1

*1

*4

*4

*2 *3 *3

UIQS-590A is required for THI. UIDM-590A, UIPS-590A, UIMV-590A, and UIQS-590A are required. Only for 3rd port. Premium kit and CV kit (UICV-590A) or UICW-590A is required. These transducers are no longer available for purchase. The transducers at the customer sites can still be used.

block chArt SyStEMS


Nemio MX Main unit SSA-590A B-PSP & CDI-PSP/QSP kit UIQS-590A CW kit UICW-590A Trapezoid scan kit USTS-590A Reference signal kit UJUR-590A Reference signal kit UJUR-592A Transducer selector UIPS-590A M-TEE hanger kit UAEH-590A Footswitch kit UZFS-590A Gel warmer UZGW-590A Data Management unit UIDM-590A DICOM system kit UDDS-590A Stress Echo kit UDSE-590A Panoramic View kit UDPA-590A Mecha 4D kit UIMV-590A* 4D transducer PVM-375MV

DCA kit USDA-590A HPRF kit USHP-590A TDI kit USTD-590A ACM kit USAC-590A CHI/FEI kit USHI-590A TIC kit USTI-590A Dynamic Flow kit USDF-590A Mounting kit for peripheral unit (for a single unit) UZRI-590A Mounting kit for peripheral unit (for 2 units) UZRI-591A

* UIQS-590A and UIPS-590A are required.

MPDUS0017EA

SPEcificAtioNS
System
Transducer: Focusing: M-series with Echo Booster (Chip-in-the-Tip) Autofocusing with Digital Continuous Beam Former of ROI-tracing type Available

Image processing:

Dynamic range: Edge enhancement: Automatic gain control: Postprocessing: Temporal smoothing: Spatial smoothing: Contrast enhancement: Frame rate: Compounding Scan (ApliPure): Auto STC/GAIN adjustment (QuickScan):

5 IP types are available. The following parameters can be controlled. 30 to 100 dB (can be set independently for 2D and M) OFF, 1, 2, 3 4 types 2D, 8 types OFF, 1 to 5 4 types OFF, ON (can be set independently for 2D and THI) Max. 391 frames/s Available with all convex and linear transducers

Protocol Registration (SonoSet):

2D- and M-modes


Scanning methods:

Electronic convex scan Electronic linear scan Electronic sector scan Electronic trapezoid scan*
* Available with PLM-703AT, PLM-805AT, PLM-1204AT, PLM-503AT, PLM-1202S, PLF-308P, PEF-704LA, PVL-715RT

Scan width:

WIDE (100%)/WIDE-MIDDLE (80%)/MEDIUM (70%)/ NARROW (50%)/FREE (Min. 20) 2 to 24 cm, 1-cm steps L, H 10 Max. 5 (including THI) Single 1, 2, 4, 8 s/screen Moving bar 8 steps max. Continuous 62 to 100 dB for B-mode 52 to 110 dB for M-mode 8-step sliding VRs. Corresponds to the viewing depth

Available

2D Depth: Line density: Independent steering angle: Multiple frequencies: M-mode Channel: Sweep speed: Display method: Focusing Transmission: Reception: Gain adjustment Palm controller: STC (DGC):

4D (UIDM-590A, UIPS-590A, UIMV-590A, UIQS-590A, and PVT-375MV are required)


Acquisition modes: Display modes:

3D display modes: Review modes:

Measurements: Image storage: Control method:

4D Live, Single Sweep Single display of a 2D image, Single diplay of a 4D image, Single display of a planar image of a 4D image, Dual display of a 4D image and a planar image, 4-frame display of a 4D image and three planar images, Multiframe display of planar images of a 4D image Real-time, Freeze 4D volume cine playback, movie play back, frame-by-frame playback Distance, angle, area 4D volume, movie (dynamic image), still image Operation from the main panel (switches, paddle switches, rotary encoders)

Spectrum Doppler (SD)


Mode:

Pulsed-Wave Doppler (PWD), Continuous-Wave Doppler with Pencil Transducer, Full Steerable Continuous-Wave Doppler (SCWD) 1.3 to 15.2 kHz, PWD 5.8 to 15.2 kHz, HPRF (USHP-580A is required) 4.0 to 47.6 kHz, CWD 31 dB (1-dB steps) PWD, 7 steps CWD, 7 steps 13 steps (1 to 15 mm) Reverse (toward/away flow) display, Base shift, B-refresh (Manual, Time, ECG-Sync), D-expand, 2D/D-expand, Angle mark 20 max. (2 steps) 2D+SD (vertical layout, horizontal layout) SD Base shift, Velocity Range Available

Pulse repetition frequency (PRF):

Gain: Doppler filter: Sampling width: Display control:

Independent steering angle: Audio stereo output Display format:

Velocity range (scale) The following parameters can be changed with one dial. Alternative step: 16 PRF: 1.3 to 12.5 kHz Color filter: 4 types Motion eliminator: 4 types Gain: 1 to 16 dB 0.5-dB steps Display format: CDI, CDI/CDI CDI+MCDI MCDI Image processing: Programmable image quality adjustment function; for Time Smooth (3 types), Spatial Smooth (5 types) Display control: Base shift, Color contrast, B/W and color balance, CDI ROI, Reverse Independent steering angle: 20 max (2 steps) Color density: L/M/H/SH Frame rate: Max. 371 frames/s (UIQS-590A is required)

Auto adjustment: Real time Auto trace: Maximum measurable velocity PW: 6.75 m/s (3.37 m/s) HPRF: 6.75 m/s (3.37 m/s) CW: 19.2 m/s (9.65 m/s) Auto Velocity Range and Zero Shift Control (iDoppler): Available

Advanced Dynamic Flow (USDF-590A is required)

Applicable transducers: PVM-375AT, PLM-1204AT PLM-703AT, PSM-20CT, PSM-37CT, PSM-30BT PLM-805AT

CHI/FEI kit (USHI-590A is required)


Injection Timer: Mode:

Color Doppler (CDI)


Display mode:

Color-reversed: Color contrast:

Velocity-Variance (3 types) Power (4 types) Directional Power (4 types) (USDA-590A is required) Power variance (1 type) Variance (1 type) Velocity HUE (4 types) Velocity SATURATION (3 types) TDI HUE (2 types, option) QUANT (1 type) Available 4 steps

Available 2D, Power, Dynamic Flow kit (USDF-590A is required) Flash Trigger: Manual, Internal, ECG Multiple Flash: 115 Monitor Mode: Available Applicable Transducers: PSM-20CT, PSM-37CT, PSM-30BT, PVM-375AT

Data Management unit (UIDM-590A is required)


Acquiring and saving ultrasound images: Acquires dynamic and still images output from diagnostic ultrasound systems used for routine examinations and/or detailed examinations in hospitals or examination rooms and saves such images.

MPDUS0017EA
Acquisition methods: Acquisition of images into the ultrasound workstation is performed using either of two techniques: one is Pre-Trigger/PostTrigger acquisition, for standard real-time images; and the other is IM-Transfer acquisition, in which the images stored in image memory of the diagnostic ultrasound system are acquired one at a time in order to acquire images with a higher frame rate. Output to the Printer Output to the printer provided with the diagnostic ultrasound system Output to the network printer in DICOM format Output to local or network printers that are Windows XP compatible Report WMS (Wall Motion Scoring): Conforms to ASE. Import and display of various measurement results Display of data measured by the diagnostic ultrasound system Paste of image Entry of comment

Displaying and editing images: Displays on the monitor the images acquired as described above and permits the user to display these images for fourframe display, playback in synchronization with the R wave of the ECG, etc. Support of DICOM functions (UDDS-590A is required): Supports the following DICOM functions. Storage SCU/SCP* Query/Retrieve SCU Print SCU* MWM SCU (Modality Worklist Management)* Storage Commitment SCU Modality Performed Procedure Step SCU Structured Reporting SCU Scheduled Workflow Patient Information Reconciliation Veterans Affairs Evidence Document Measurement TAG
* UDDS-590A is not required.

Acoustic output power adjustment

B/M, Doppler and Color Doppler output: 10% to 100%, 5% steps (varies according to transducer) Auto gain control: Automatic gain compensation for lower acoustic output power setting

Display

Gray scale level: Format B/M scan: Doppler (D-mode): Color Doppler:

256 2D (dual 2D), 2D/M, M 2D, 2D/M/D, 2D/D, M/D, D CDI (dual CDI), CDI/MCDI CDI/MCDI/D, MCDI, MCDI/D, 2D/CDI 15-inch LCD color monitor DVI-D single link

Stress echo (UDSE-590A is required): Provides the acquisition/display/ scoring functions which support stress echo examinations in the hospital or laboratory. Integrated operability: Can be operated from the main panel of the diagnostic ultrasound system and supports transmission/reception of data including patient IDs. Panoramic View (UDPA-590A is required): This function enables a continuous image for a wide area to be displayed by moving the transducer along the body surface.

Observation monitor: Interface: PAN/ZOOM (EXPAND) ZOOM (EXPAND) method: Real-time/ROI specified (selected using the preset only) Images for ZOOM (EXPAND): Real-time images and FREEZE images Magnification factor: Up to a viewing field of 2 cm PAN method: Real-time images, FREEZE images and IM images Images for PAN: Real-time images, FREEZE images, and IM images Other types of control: The transmission focus is optimized. EXPAND for real-time images optimizes the number of rasters. Language: English, German, French, American English, Italian, Spanish, Portuguese, Norwegian, Finnish, Swedish Others: Display reversal: Left-Right, Top-Bottom, 90-step rotation.

Reference signal kit

This function provides reference signal display and ECG trigger mode in single mode. This mode requires the reference signal kit UJUR-590A. Signal: ECG (Lead II) AUX PCG ECG Trigger: 1 channel PCG Filter: 3 steps available ECG syncronization setting: 0 to 1.94 s

Image memory

No. of images that can be recorded 2D mode: Up to 512 images CDI mode: Up to 512 images M mode MCDI mode PWD/CWD mode: Up to 120 s

Doppler: VTI measurement (Conti. Equation) Flow volume measurement (F Vol VTI) Velocity ratio measurement (RATIO) Velocity ratio measurement (RI) Velocity measurement (F Vol Vel Trace) Mitral valve measurement Mitral valve regurgitation measurement (MR) Aortic valve function measurement Aortic valve regurgitation measurement (AR) Tricuspid valve measurement Tricuspid valve regurgitation measurement (TR) Pulmonary valve measurement Pulmonary vein measurement Obstetric calculations: Up to 16 items can be measured, including fetal growth, gestational age, estimated delivery date, etc. Trend graph function Report items: Patient ID, application measurement data, comment

Measurement
B mode:

M mode: Doppler:

CDI

Distance (8 ch), angle (8 ch), area (8 ch), circumference (8 ch), volume (1 ch), cross distance (8 ch), parallel distance (8 ch), hip joint (8 ch), meanIMT (8 ch), and curve distance (8 ch) Distance (8 ch), time (8 ch), slope (8 ch), heart rate (1 ch) Velocity (8 ch), time (8 ch), acceleration (8 ch), heart rate (1 ch), velocity trace (8 ch) Velocity histogram (2 ch), velocity (8 ch), profile (2 ch)

Security functions

Log on Maximum number of characters for user name: 64 alphanumeric characters Maximum number of characters for password: 64 alphanumeric characters Maximum number of users that can be registered: 64 users Entry of user names and passwords is case-sensitive. Log off Emergency Log-on

Image Export via USB

Application software (calculation, measurement, etc.)


mode 2D mode M mode

Memory Device (Operation with all memory devices is not guaranteed.)

Calculation of left ventricular (LV) function method Single-plane, Biplane, Bullet, Simpson, Modified Simpson, Cube Cube, Teichholz, Gibson M mode M mode 2D mode, M mode 2D mode

Measurement of mitral valve (MV) function: Measurement of aortic valve (AV) function: % Stenosis: Prostate:

MPDUS0017EA Input/Output B/W Printer

Transducer connectors: Max. 3 for standard electronic transducers 1 for pencil transducer Composite output signals Color: 1 B/W: 1 S-VIDEO input/output Input: 2 Output: 2 RGB input/output Output: 1 DVI Output: 1 Printer control signal Output: 2 Audio input/output Input: R+L Output: R+L RS-232C: 1 port VCR/DVD recorder control Ethernet: 100Base-T 1 (UIDM-590A is required) USB: 1 (front) 4 (rear) Footswitch: 2 (front) Reference signal ECG: 1 AUX: 1 PCG: 1

Recommended B/W printer models Sony: UP-897, UP-D897* Mitsubishi: P93W, P93DW*, P95DW*
* UZCA-590A is required

Color Printer

Recommended color printer models Sony: UP-25MD, UP-D23MD* UP-D25MD* Mitsubishi: CP30W, CP30DW*
* UZCA-590A is required

DVD Recorder

Recommended DVD recorder model Victor BD-X201ME (PAL) BD-X201M (NTSC/PAL)

Recording

CD/DVD drive (supports DVD-R, DVD-RW, DVD+R, DVD+RW, CD-R, CD-RW, and DVD-RAM) HDD image filing (80 GB) Color video printer B/W video printer DVD recorder

oPErAtiNg coNDitioNS
Power supply requirements Line voltage: 100 VAC to 127 VAC (50 Hz) 220 VAC to 240 VAC Line frequency: 50 Hz to 60 Hz Power capacity: 1030 VA (max.) Environmental conditions Operating conditions Ambient temperature: 10C to 35C Relative humidity: 35% to 85% (no condensation) Atmospheric pressure: 700 hPa to 1060 hPa Storage and transportation conditions Ambient temperature: -10C to 55C Relative humidity: 30% to 85% (no condensation) Atmospheric pressure: 700 hPa to 1060 hPa Safety classification According to the type of protection against electric shock: CLASS I EQUIPMENT According to the degree of protection against electric shock: EQUIPMENT WITH TYPE-BF APPLIED PARTS According to the degree of protection against harmful ingress of water: Ordinary EQUIPMENT (enclosed EQUIPMENT without protection against ingress or water) According to the degree of safety of application in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE: EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE According to the mode of operation: CONTINUOUS OPERATION

coNforMANcE StANDArDS
EU and other regions requiring compliance with European Directive 93/42/EEC and subsequent amendments General: EN60601-1 (2006) Particular: EN60601-2-37 (2008) Acoustic power: Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers (2008) (FDA guidance) EMC: EN60601-1-2 (2007) Other regions General: Particular: Acoustic power: IEC60601-1 (1988), Amd. 1 (1991), Amd. 2 (1995) IEC60601-2-37 (2001), Amd. 1 (2004), Amd. 2 (2005) Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers (2008) (FDA guidance) IEC60601-1-2 (2001), Amd. 1 (2004)

EMC:

DiMENSioNS AND MASS


External dimensions: Color systems (including cardiovascular color systems): 451 mm (W) 785 mm (D) 1,276 to 1,488 mm (H) Approximately 83 kg (peripheral units and TEE stand not included)

Mass:

10

MPDUS0017EA

MASS
model name
System main unit SSA-590A BD-X201M BD-X201ME CP30W CP30DW P93W P93DW P95DW UAEH-590A UDDS-590A UDPA-590A UDSE-590A UICV-590A UICW-590A UIDM-590A UIMV-590A UIPS-590A UIQS-590A UIUG-590A UJUR-590A UJUR-592A UP-25MD UP-D23MD UP-D25MD UP-897 USAC-590A USDA-590A USDF-590A USHI-590A USHP-590A USTD-590A USTI-590A USTS-590A UZCA-590A UZFS-590A UZGW-590A UZRI-590A UZRI-591A Main unit DVD DVD Color printer Color printer B/W printer B/W printer B/W printer M-TEE hanger kit DICOM system kit Panoramic View kit Stress Echo kit CV kit CW kit Data management unit Mecha 4D kit Transducer selector B-PSP & CDI-PSP/QSP kit Premium kit Reference signal kit Reference signal kit Color printer Color printer Color printer B/W printer ACM kit DCA kit Dynamic Flow kit CHI/FEI kit HPRF kit TDI kit TIC kit Trapezoid scan kit Cable for printer Footswitch kit Gel warmer Mounting kit for peripheral unit (for a single unit) Mounting kit for peripheral unit (for 2 units) 83 (183.0) 4.8 (10.6) 4.8 (10.6) 7.3 (16.1) 7.3 (16.1) 2.8 (6.2) 2.8 (6.2) 2.6 (5.7) 1.6 (3.5) 0.5 (1.1) 0.5 (1.1) 0.5 (1.1) 1.4 (3.1) 0.5 (1.1) 1.4 (3.1) 0.7 (1.5) 0.3 (0.7) 0.1 (0.2) 2.0 (4.4) 0.9 (2.0) 0.9 (2.0) 5.7 (12.6) 6.5 (14.3) 5.5 (12.1) 2.6 (5.7) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.1 (0.2) 0.5 (1.1) 1.4 (3.1) 1 (2.2) 1.2 (2.6) 2.1 (4.6) Options/Accessories for main unit

name of component

mass [kg] (lb)

model name
Transducers PC-19M PC-50V PEF-510MA PEF-704LA PLF-308P PLM-503AT PLM-703AT PLM-805AT PLM-1202S PLM-1204AT PSM-20CT PSM-30BT PSM-37CT PSM-50AT PSM-70AT PVF-381MT PVF-620ST PVF-738F PVF-738H PVF-745V PVL-715RT PVM-375AT PVM-375MV PVM-381AT PVM-620ST PVM-651VT PVM-662AT PVM-672AT PVM-740RT PVM-787LA

name of component
Pencil transducer Pencil transducer Transesophageal transducer Laparoscopic transducer Biopsy transducer Linear transducer Linear transducer Linear transducer Linear transducer Linear transducer Sector transducer Sector transducer Sector transducer Sector transducer Sector transducer Convex transducer Endocavitary transducer Micro transducer Micro transducer Micro transducer Endocavitary transducer Convex transducer Convex transducer Convex transducer Endocavitary transducer Endocavitary transducer Convex transducer Convex transducer Endocavitary transducer Laparoscopic transducer

mass [kg] (lb)


0.11 (0.2) 0.08 (0.2) 1.5 (3.3) 0.94 (2.1) 0.74 (1.6) 0.7 (1.5) 0.7 (1.5) 0.7 (1.5) 0.56 (1.2) 0.7 (1.5) 0.6 (1.3) 0.5 (1.1) 0.6 (1.3) 0.6 (1.3) 0.6 (1.3) 0.55 (1.2) 0.73 (1.6) 0.45 (1.0) 0.45 (1.0) 0.45 (1.0) 1.4 (3.1) 0.8 (1.8) 0.9 (2.0) 0.55 (1.2) 0.75 (1.7) 0.9 (2.0) 0.7 (1.5) 0.55 (1.2) 1.4 (3.1) 1 (2.2)

11