CLIENTS : PGN, PERTAMINA, PUSLITBANG HANKAM, LABINKAP, PETROKIMIA GRESIK, PUSRI, PUPUK KALTIM, PLN, SEMEN GRESIK, JASA MARGA, BADAK NGL, TOTAL INDONESIE, PDAM, PT SI, JATILUHUR, PERINDUTRIAN, CNOOC, KODECO, KANMETA ENG. JAPAN, PREMIER OIL, PT GARUDA IND, NURTANIO, BKI, GEOTHERMAL, MANY OTHER PRIVATE COMPANIES..CHEVRON. ORGANISATION ICC, APMACA. PAPERS : ASEAN, ASEAN-JAPAN, ASEAN-EEC, INDOCOR, NACE, : National and International

1. PESERETA KURSUS MEMAHAMI LINGKUP APLIKASI PK YANG SANGAT LUAS. 2. MEMAHAMI TUJUAN PENERAPAN PK. 3. MEMAHAMI UNTUNG RUGI DARI MASING2 SISTEM PK. 4. MEMAHAMI DASAR2 PEMILIHAN SISTEM. 5. MENGETAHUI ADA INTERFERENSI. 6. MEMAHAMI FASILITAS2 PK.

TUJUAN PENERAPAN PK
TEKNIK PROTEKSI DAPAT DITERAPKAN UNTUK MELINDUNGI LOGAM KONSTRUKSI YANG BERADA DALAM LINGKUNGAN ELEKTROLIT (TANAH, AIR, BETON). 1. BILA KRITERIA DIPENUHI, DAN PK DITERAPKAN SEJAK AWAL, STRUKTUR SECARA TEKNIS DIANGGAP IMUN DARI SERANGAN KOROSI.

PK DAN COATING
1. Coating umumnya merupakan pengendali korosi utama, tetapi coating selalu mengandung cacat (holiday). 2. Penerapan PK umumnya merupakan pelengkap coating, tetapi fungsinya vital. 3. Dalam beberapa kasus PK merupakan pengendali korosi tunggal.

PIPA : 1. Crude 2. Bbm termasuk untuk pesawat udara 3. Gas alam 4. Bahan kimia 5. Air 6. Onshore dan offshore 7. Dll.

LAS TERMIT

ANODA Mg

Proteksi katodik pipa dengan wire plastic conductive anode

TANKI 1. Air (dasar luar dan dalam) 2. Bagian dalam Tanki di atas gedung. 3. Tanki crude oil (dasar luar dan dalam) 4. Bahan Bakar Minyak 5. Tanki bahan kimia 6. Tanki ballast tank, dll

to AJB

to CJB

to CJB to AJB

3500 mm

5000mm

Ref. Cell Zn Anode

AJB : Anode Junction Box. CJB : Cathode Junction Box.

Schematic Diagram Arrangement of CP Installation for tank bottom

+TR -

Tiang Pancang dan sheet pile

1. Tiang pancang anjungan 2. Jembatan 3. Dermaga 4. Sheet pile di pinggir laut atau kanal 5. Buoy 6. Dll.

JB

TR

LAS TERMIT

ANODA

Sketsa PK tiang pancang dermaga

ANJUNGAN 1. Anjungan lepas pantai 2. Anjungan darat 3. Riser 4. Dll.

STRUKTUR BANGUNAN 1. Tiang Jembatan 2. Tulangan beton 3. Tiang pancang 4. Pelataran beton 5. Dll.

Tulangan beton tanpa proteksi katodik

PK SISTEM ANODA KORBAN

I
Anoda korban Mg, Al, Zn

Struktur yang diproteksi

PK SISTEM ARUS TANDING TR

Anoda : Struktur yang diproteksi boros, sedang, awet

UNTUNG

1 . TAK PERLU LISTRIK 2. PEMASANGAN MUDAH 3. TAK ADA INTERAKSI 4. OVERPROTEKSI RINGAN 5. COCOK UNTUK ARUS KECIL (murah) 6. UNTUK DAERAH PADAT STRUKTUR 7. DISTRIBUSI ARUS MERATA 8. TAK PERLU PEMELIHARAAN 9. CUKUP INSPEKSI RUTIN 10. TAK PERLU BIAYA OPERASI

RUGI

1 . KELUARAN ARUS TERBATAS 2. TAK EFEKTIF BILA RESISTIVITAS ELEKTROLIT TINGGI 3. TAK COCOK UNTUK STRUKTUR BESAR YANG PERLU ARUS PROTEKSI BESAR.

UNTUNG

1 . COCOK UNTUK STRUKTUR BESAR 2. DISAIN SESUAI DENGAN KEPERLUAN 3. DAPAT UNTUK SEMUA NILAI RESISTIVITAS LINGKUNGAN 4. ARUS PROTEKSI MUDAH DIATUR 5. UNTUK UMUR LEBIH DARI 20 TAHUN 6. BIAYA AWAL RENDAH

RUGI

1 . KEMUNGKINAN TERJADI INTERAKSI 2. TERGANTUNG SUMBER LISTRIK 3. PERLU PEMELIHARAAN 4. INSPEKSI RUTIN LEBIH SERING 5. PERLU BIAYA OPERASI 6. PERLU RECTIFIER