Anda di halaman 1dari 5

UPRIGHT A B C D E F G H J K L M N P Q R S T

RAISING SHIM 46mm 75mm 75mm 75mm 75mm 75mm 95mm 95mm 75mm 75mm 46mm NONE NONE NONE NONE NONE 46mm 75mm

UPRIGHT HEIGHT 5813mm 5843mm 5843mm 5843mm 5843mm 5843mm 5843mm 5843mm 5843mm 5843mm 5813mm 5768mm 5768mm 5768mm 5768mm 5768mm 5813mm 5843mm

NOTE RACK WILL BE SUPPLIED WITH A NUMBER OF 3MM & 10MM SHIMS TO PACK FRONT MID AND REAR OF EVERY UPRIGHT IF REQUIRED

DETAIL C 540mm LONG RSA HORIZONTAL USED TO BRACE END FRAME TO UPRIGHT DETAIL B 1300mm LONG RSA HORIZONTAL USED TO BRACE END FRAME UPSTANDS

OBSERVE DIFFERING DRILLING POSITION FOR END PURLIN CLEATS ON THE SLOPED RSA BRACING AND POSITION CORRECTLY TO ALIGN WITH PURLIN RUN
**NOTE RACKIN

G RUN

UTILIS

ES THR

EE DIF

FEREN

T HEIG

HT UP

RIGHT

S FOR

EFFEC

TIVE L

EVELL

ING SE

E TABL

NOTE LEFT AND RIGHT HANDING OF END FRAME UPSTANDS

E FOR

LOCAT

IONS**

SEE DETAIL B

SEE DETAIL C

SCALE

1:10

14 NO. UPRIGHTS WILL REQUIRE RAISING SHIMS TO LEVEL RACK PLEASE REFER TO TABLE TO IDENTIFY SHIM HEIGHT AND LOCATION FOR RELEVANT UPRIGHT

DETAIL D NOTE EACH UPRIGHT TO BASE CONNECTION UTILISES 2 NUMBER CSK M12 SOCKET SCREWS

L SEE DETAIL D

R S T

1395mm LONG RSA HORIZONTAL USED TO BRACE UPRIGHTS


DRAWN

ER

Wickens Engineering Ltd


1 Wainwright Road Shire Business Park Worcester WR4 9FA Tel: 01905 456780 Fax: 01905 456073 e-mail: enquiries@wickens.co.uk
Drawing remains the property of Wickens Engineering Ltd. Not to be reproduced without written authority Copyright - Wickens Engineering 2003

TITLE

CHECK APPROV. ISSUE


DO NOT MODIFY THIS DRAWING BY HAND

RACK UPRIGHT & SCOOBY SHIM ARRANGEMENT

PROJECT A2
SCALE -

SSI Schaefer Ltd JOB NO. 31473


SHEET 1 of 5

ISSUE

SEE DETAIL K SEE DETAIL E

SEE DETAIL J

DETAIL J FLANGE PURLIN CLEAT TO SUIT MID CONNECTION OF PURLINS DETAIL F NOTE USE OF ZED BRACKET TO FIX REAR ROOF/GUTTER SUPPORT TO REAR END FRAME UPSTAND SEE DETAIL F

DETAIL I END FRAME PURLIN CLEAT TO SUIT END CONNECTION OF PURLINS

DETAIL E REAR ROOF SUPPORT IS PRE DRILLED ON 300mm NOM. CRS TO ACCEPT FIXING OF GUTTER BRACKET BEFORE BEING BOLTED TO REAR OF UPRIGHT

DETAIL K FLANGE PURLIN CLEAT TO SUIT END CONNECTION OF PURLIN

SEE DETAIL I

FIXING NOTE: RACK TO PURLIN CLEAT = M12 x 40 LONG SET PURLIN CLEAT TO PURLIN = M12 x 30 LONG SET

DRAWN

ER

Wickens Engineering Ltd


1 Wainwright Road Shire Business Park Worcester WR4 9FA Tel: 01905 456780 Fax: 01905 456073 e-mail: enquiries@wickens.co.uk
Drawing remains the property of Wickens Engineering Ltd. Not to be reproduced without written authority Copyright - Wickens Engineering 2003

TITLE

CHECK APPROV. ISSUE


DO NOT MODIFY THIS DRAWING BY HAND

PURLIN CLEAT & BRACKET DETAIL

PROJECT A2
SCALE -

SSI Schaefer Ltd JOB NO. 31473


SHEET 2 of 5

ISSUE

*END FRAME PURLIN LENGTH BOTH ENDS*

*BELOW DIMENSIONS ARE A BREAKDOWN OF THE FRONT ROOF SUPPORT PROFILE LENGTHS*
2138 1398 2798 2798 2798 2798 2798 2798 2798 2138

2100

1394

2794

2794

2794

2794

2794

2794

2794

2100

2100

1394

2794

2794

2794

2794

2794

2794

2794

2100

*ABOVE DIMENSIONS ARE A BREAKDOWN OF THE ROOF ZED PURLIN PROFILE LENGTHS*

*ABOVE DIMENSIONS ARE A BREAKDOWN OF THE REAR ROOF/GUTTER SUPPORT PROFILE LENGTHS*

*BELOW DIMENSIONS ARE A BREAKDOWN OF THE CURTAIN TRACK RAIL SECTION LENGTHS*
4729 2644 2800 2800 5594 2800 2800

*BELOW DIMENSIONS ARE A BREAKDOWN OF THE TRACK SUPPORT ANGLE LENGTHS*


5594 2800 4194 2800 2800 4661 2644

DRAWN

ER

Wickens Engineering Ltd


1 Wainwright Road Shire Business Park Worcester WR4 9FA Tel: 01905 456780 Fax: 01905 456073 e-mail: enquiries@wickens.co.uk
Drawing remains the property of Wickens Engineering Ltd. Not to be reproduced without written authority Copyright - Wickens Engineering 2003

TITLE
PROFILE

CHECK APPROV. ISSUE


DO NOT MODIFY THIS DRAWING BY HAND

PURLIN, ROOF SUPPORT & TRACK ARRANGEMENT

PROJECT A2
SCALE -

SSI Schaefer Ltd JOB NO. 31473


SHEET 3 of 5

ISSUE

FRONT VIEW OF RACK

PLAN VIEW OF RACK

2940

2940

SEE DETAIL L

3085 DEEP ROOF SHEETS TO BE BUTTED AGAINST TOP FRONT ROOF SUPPORT 26 SHEETS REQUIRED ALONG THE LENGTH

CLADDING NOTES: FRONT SIDE FLASHING MUST BE TEK SCREWED INTO FRONT FRAME PFC UPSTAND TOP ROOF FLASHING MAY NEED TRIMMING TO CLEAR GUTTER END FITTING ALL FLASHING TO BE TEK SCREWED DOWN ON RIDGES OF WALL PROFILE AT SUITABLE POINTS

FRONT ROOF PROFILE TO BE SET IN POSITION BY ROOF SHEET AND THEN TEK SCREWED INTO FRONT FACE OF TRACK SUPPORT ANGLE GUTTER END CAPS FITTED TO EITHER END OF GUTTERING RUN

SEE DETAIL M

2 No. TOP 200 x 200 ROOF FLASHING @3M TRIMMED DOWN IN LENGTH TO SUIT 4 NO. GUTTER JOINERS & 2 NO. DOWNPIPE CONNECTORS SUPPLIED TO CONNECT GUTTER PROFILES TOGETHER 7 NO. LENGTHS OF 4M GUTTERING WILL BE SUPPLIED TO CUT TO SUIT 3 No. FRONT 250 x 250 SIDE FLASHING @3M TRIMMED DOWN IN LENGTH TO SUIT PRE DRILLING IN REAR SUPPORT PROFILE ALLOWS THE GUTTER SUPPORT BRACKETS TO BE LOCATED ON NOMINALLY 1M CRS THIS FLASHING WILL NEED TO BE LAID UNDER TOP FLASHING AND BEHIND THE FRONT ROOF SUPPORT PROFILE THIS FLASHING WILL NEED TO BE LAID OVER SIDE FLASHING

GUTTERING NOTES: GUTTERING WILL BE SUPPLIED WITH TWO NO. Y-CONNECTIONS TO TAP INTO EXISTING BUILDING DOWNPIPES SUITABLE DOWNPIPES 135 JOINERS + STRAIGHT COUPLERS WILL BE SUPPLIED TO CREATE CONNECTION

2 No. REAR 200 x 200 SIDE FLASHING @3M TRIMMED DOWN IN LENGTH TO SUIT THIS FLASHING WILL NEED TO BE LAID UNDER TOP FLASHING

3 No. SIDE WALL SHEETS PER SIDE @6,200mm TALL TO BE TRIMMED TO SUIT 10 TOP SLOPE

DRAWN

ER

Wickens Engineering Ltd


1 Wainwright Road Shire Business Park Worcester WR4 9FA Tel: 01905 456780 Fax: 01905 456073 e-mail: enquiries@wickens.co.uk
Drawing remains the property of Wickens Engineering Ltd. Not to be reproduced without written authority Copyright - Wickens Engineering 2003

TITLE

CHECK APPROV. ISSUE


DO NOT MODIFY THIS DRAWING BY HAND

CLADDING, FLASHING & GUTTER DETAIL

PROJECT A2
SCALE -

SSI Schaefer Ltd JOB NO. 31473


SHEET 4 of 5

ISSUE

TRACK SUPPORT BRACKET CONNECTS TO THE UNDERSIDE OF THE SUPPORT ANGLE AND CAN BE SHIMMED IF REQUIRED USING SPECIAL SLOTTED SPACERS

TRACK SUPPORT ANGLE SUPPORTS CURTAIN TRACK BRACKET ON UNDERSIDE FRONT ROOF SUPPORT PROFILE TEK SCREWS INTO THE FRONT FACE AT SUITABLE POSITIONS

TRACK SUPPORT ANGLE FIXED TO ROOF ARM WITH M12 CSK SOCKET SCREWS

SEE DETAIL N SEE DETAIL O SEE DETAIL P

TRACK SUPPORT BRACKET UTILISES TWO LOCKING SCREWS THAT ALLOW THE ENDS OF TWO TRACKS TO BE CLAMPED TOGETHER AND ALIGNED

CURTAIN ROLLER

ARM MESH SHELVES UTILISE M8 x 75mm HEX HEAD SETS TO BOLT THROUGH ARM SECTION FRONT FRAME UPSTAND HAS BAR STRAP TAGS TO ALLOW CURTAIN TO STRAP TO UPSTAND AT THREE CERTAIN POSITIONS THIS FIXING LINK WILL BE SUPPLIED FITTED TO THE CURTAIN. SIMPLY BOLT TO ROLLER ON SITE WHILE FITTED TO CURTAIN BASE MESH SHELVES UTILISE SOCKET BUTTON FIXINGS TO BOLT DOWN ONTO BASE FLANGE

DRAWN

ER

Wickens Engineering Ltd


1 Wainwright Road Shire Business Park Worcester WR4 9FA Tel: 01905 456780 Fax: 01905 456073 e-mail: enquiries@wickens.co.uk
Drawing remains the property of Wickens Engineering Ltd. Not to be reproduced without written authority Copyright - Wickens Engineering 2003

TITLE

CHECK APPROV. ISSUE


DO NOT MODIFY THIS DRAWING BY HAND

CURTAIN TRACK DETAIL & SHELF DETAIL

PROJECT A2
SCALE -

SSI Schaefer Ltd JOB NO.


SHEET 5 of 5

ISSUE