Pay Special Attention to Following Alarms


BD_STATUS DOWN_E1_AIS ETH_LOS HARD_BAD IF_INPWR_ABN MW_LOF RADIO_FADING_MARGIN_INSUFF T_ALOS RADIO_RSL_LOW

BD_STATUS
Alarm Severity Major Alarm Type Equipment Alarm Board ODU Possible Causes Cause 1: Other alarms are generated. (IF_CABLE_OPEN, VOLT_LOS) Cause 2: The ODU is faulty.

Page 3

IF_CABLE_OPEN
Alarm Severity Major Alarm Type Equipment Alarm Board IF Port Possible Causes Cause 1: The IF Cable is Loose or Faulty Cause 2: The IF Port of the IDU is Damaged Cause 3: The Power Module of ODU is Faulty

VOLT_LOS
Alarm Severity Major Alarm Type Equipment Alarm Board Power Module, IF Board Possible Causes Cause 1: The Output Power is Abnormal Cause 2: The Input Power is Abnormal Cause 3: Lightning Occurs

DOWN_E1_AIS
Alarm Severity Major Alarm Type Communication Alarm Board E1 Tributary Card Possible Causes Cause 1: The Opposite Side Transmits UP_E1_AIS Alarm Cause 2: The IDU is faulty.

Page 6

UP_E1_AIS
Alarm Severity Minor Alarm Type Communication Alarm Board Possible Causes E1 Tributary Board Cause 1: The opposite equipment transmits the AIS signal. Cause 2: The receive unit of the tributary unit at the local site is faulty.

T_ALOS
Alarm Severity Alarm Type Board Possible Causes

Major

Communication Alarm

E1 Tributary Board Cause 1: The interface does not access 2 Mbit/s services. Cause 2: The opposite equipment is faulty. Cause 3: The trunk cable is faulty. Cause 4: The board that reports the alarm is faulty.

Page 8

ETH_LOS
Alarm Severity Critical Alarm Type Communication Alarm Board Ethernet Board Possible Causes Cause 1: The negotiation fails because the transmit port and receive port work in different modes. Cause 2: The link of electrical cable or optical fiber is faulty. Cause 3: The equipment is faulty.

Page 9

IF_INPWR_ABN
Alarm Severity Major Alarm Type Equipment Alarm Board IF Board Possible Causes Cause 1: The IDU is Faulty Cause 2: The ODU is Faulty Cause 3: The IF Cable is Faulty

Page 10

MW_LOF
Alarm Severity Critical Alarm Type Communication Alarm Board IF Board Possible Causes Cause 1: The other alarms are generated. Cause 2: In the case of TDM radio services, the IF working modes at the local site and the opposite site are different. In the case of Hybrid radio services, the channel bandwidth and modulation modes at the local site and the opposite site are different. Cause 3: The working frequency of the ODU at the local site is inconsistent with the working frequency of the ODU at the opposite site. Cause 4: The transmit unit of the opposite site is faulty. Cause 5: The receive unit of the local site is faulty. Cause 6: The receive power of the ODU is abnormal. Cause 7: An interference event occurs.

Page 11

RADIO_FADING_MARGIN_INSUFF
Alarm Severity Minor Alarm Type Equipment Alarm Board ODU Possible Causes Cause 1: The ODU fault at the transmit end causes abnormal transmit power. Cause 2: The direction of the antenna is deflected. Cause 3: Transmission environment changes. Cause 4: The fading margin in the case of rain and fog in the network planning is insufficient.

Page 12

RADIO_RSL_LOW
Alarm Severity Critical Alarm Type Service Alarm Board ODU Possible Causes Cause 1: Certain other alarms occur at the opposite site. Cause 2: The transmit power of the opposite site is low. Cause 3: The local ODU is faulty. Cause 4: Signal attenuation on the radio link is heavy.