Anda di halaman 1dari 9

JC International Limited

RC. 413243

OFFSHORE CRANE INSPECTION REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Name & Address of the Owner of the Crane SEADRILL Name & Address of the Maker of the Crane NATIONAL OILWELL Type of Crane & Source of Power ELECTRICALLY / HYDRAULIC POWERED PEDESTAL CRANE Model No. Pedestal Height from Main Deck
OC3932KCE Date of last previous test of Crane: 15/12/2008

Requested By:

Date of Examination

4/03/2012
Date of manufacture of Crane 2008 Type of Derricking Interlock Place of Survey KNUKLE BOOM Maker Serial Number T6854 WEST CAPELLA Owners distinguished Mark or No.

10 MTRS
Relevant Standard API RP 2D, ISO 4309-1990

STBD FWD 1 Date of last previous thorough examination of Crane 17/08/2011 (i)
Length of jib (feet/mtrs)

Type of inspection:

(ii)
Boom Radius

(iii)
Boom Angle (Degrees)

(iv)
Test Load (Tonne)

(v)
S.W.L(Tonne)

Thorough Visual Examination and Functional testing

(feet/mtrs)

N/A

24mtrs

N/A

N/A

17 tons

In the case of a crane with a derrick jibs, the maximum angle at which the jib may be worked. N/A

Defects noted and alterations and repairs required before the Crane is put into service ( if none enter NONE)
N/A

Boom Cylinders

(Construction, Size)

N/A

(Parts of line) =

SWL

Aux. Hoist Wire Rope

N/A
(Construction, Size) X
34mm X 34 X 7 WSC

N/A

(Parts of line) =
1

N/A

SWL

Main Hoist Wire Rope

(Construction, Size) Load Measuring Device: N/A LOCATION OF CRANE:

(Parts of line) =

21.6 tons

SWL

KBC 1 STB FWD CRANE


STANLEY UNANAM FID, SNT LEVEL II MT, PT, UT, VT, FID, Lifting Equipment Insp.
SNL MODULE 3

INSPECTOR NAME/QUALIFICATTION:

Page 1 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

A)

WIREROPE AND HOOK

Inspect, measure wire rope with Venier caliper And record: Construction, Diameter, Type End, Orientation. BOOM LINE a) b) Nominal diameter of Boom Line: Measured Diameter of Boom Line: Boom Cylinders Use

Worst percentage of Wear Reduction at Different Section of Boom Line: Maximum Allowable: 10% = Defect which may impair continued use of this wire rope: Overall Assessment: c) d) Installed Date: Wire rope condition: N/A

LOAD LINE e) f) Nominal diameter of Load line: Measured diameter of Load line: 34mm 34mm

Worst percentage of Wear Reduction at different sections of Load line: Maximum Allowable 10% = Defect which may impair continued use of this wire rope: Overall Assessment: Installed Date: g) Wire rope condition:

None Ok 12/06/2011 Ok

AUX. LINE h) i) Nominal diameter of Aux. line: Measured diameter of Aux line: N/A

Worst percentage of Wear Reduction at different sections of Aux line:

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

Maximum Allowable 10% = Defect which may impair continued use of this ire rope: Overall Assessment: j) Installed Date: N/A
k)

Wire rope condition: l) Pendant Line (R): Installed Date: m) Pendant Line (L): n) Installed Date:

Boom Cylinders Use

B)

INSPECT HOOK FOR CRACKS AND DEFORMATION.

CONDITION

COMMENTS

a) Safety Latch: b) Wedge Sockets:

Good Good

Ok Ok

c) Proper loop and end termination of dead ends:

Yes

Ok

d) Swivel Condition: e) Pin Condition:

Good Good

Ok Ok

f)

Hook Throat Opening:

Good

Ok

g) Main Hoist Block Hook h) Manufacturer: i) Rating:

R21788 National Oilwell 17.5 Tons

i) Sheaves bearings and Bushing: j) Broken Wires

Ok None None None None

Good

a) Number of Broken wires in one strand: b) Number of Broken wires in one lay: c) Numbers of Broken wires at the end fitting:

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

Page 3 of 8

C 1.

WIRE ROPE WINCH DRUMS Main Line Hoist Drum Winch a) Rope Properly Reeved:

CONDITION

COMMENTS

Good

Properly Reeved

b) Main Hoist Rope Reeving: Number of parts:

c) Main Hoist Dead End Anchor Condition:

Good

Ok

d) Wedge Socket: 2. Aux line Hoist Drum: a) Rope properly reeved: b) Aux Hoist Rope Reeving: Number of parts: c) Aux Hoist Dead End Anchors Condition: d) Wedge Socket: 3. a) Boom Line Hoist Drum: Rope properly Reeved: b) Boom Hoist Rope Reeving: Number of parts:

Good

Properly socket

N/A

Boom Cylinders Use N/A

c) Boom Hoist Dead End Anchor Condition:

e) Wedge Socket:

D.

BOOM AND SHEAVES

CONDITION

COMMENTS

a)

Anti two Block Device:

Good

Ok

b) Boom Structural Components: c) Boom Length:

Good N/A

Ok

d) Condition of Pins/keeper/Bolts:

Good

Ok

e) Boom Stop:

Good

Ok
Page 4 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

f)

Number of Sections:

Ok

g) Hose/Cable Condition:

Good

Ok

h) Number of Sheaves:

(Boom Cylinder Use)

Ok

i)

Inspect Chords and Lacings :

N/A

j)

Boom Pendant connection pont condition:

N/A

k) Boom Hoist limit:

Good

Ok

l)

Boom Rest Welds/ Condition:

Good

Ok

n)

Sheave condition:

Good

Ok

E.

UPPER REVOLVING MACHINERY

CRANE ELECTRIC MOTOR HOUSING

CONDITION

COMMENTS

a) Housing condition:

Good

Ok

b) Door (Locks, Access, Operations & Latches). c) Walkways (Non-slip surface, Platforms & Railings).

Good Good

Ok Ok

d) Access ( Steps, handholds & ladders).

Good

Ok

e)

Roof ( Non-slip guards, Leaks). Housekeeping. CONDITION OF CONTROLS

N/A N/A

Ok Ok

f) F.

a) Main Hoist control identified and operating properly:

Yes

Ok

b)

Boom Cylinder control identified and operating properly:

Yes

Ok

Page 5 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

c)

Aux. Hoist control identified and operating properly:

N/A

d)

Slewing control type: Electric Motor:

Yes

Ok

e)

Slewing Brake operating properly:

Yes

Ok

f)

Boom upper limit switch:

Good

Ok.

g) G a) b) c)

Boom lower limit switch: BRAKES Main electric hoist brake system: Aux electric hoist brake system: Boom electric hoist brake system:

Good

Ok

Good N/A Good

Ok

Ok

d) e)

Swing electric hoist brake system Swing Ring: Slewing ring condition: Slew ring motor:

Good

Ok

Good Good

Ok Ok

OPERATORS CAB a) Operators manual:

CONDITION

COMMENTS

Yes

Ok

b) Rated Capacity Chart: . c)

Yes

Ok

Hand Signal Chart: d) Boom Angle Indicator:

Yes Yes

Ok Ok

e) Control identification:

Yes

Ok

f)

Engine emergency stop:

Yes

Ok

g) Audible Warning Device:

Yes

Ok

Page 6 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

h) i)

Fire Extinguisher: Load Indicator

Yes N/A

Ok Ok

PEDESTAL VISUAL INSPECTION

CONDITION

COMMENT

a)

Condition of Pedestal / Weld:

Yes

Ok

b)

Access ladders/step:

Yes

Ok

Page 7 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

JC International Limited
RC. 413243

GENERAL

Inspect the following: a) Electric Swivel:

CONDITIONS Good

b)

Safety System:

Good

c)

Electrical Devices:

Good

d)

Radius/ Angle Indicator:

Good

e)

Load Indicator:

Good

f)

Current log Record book:

Good

g)

Load Chart:

Good

h) i)

Control Identification: Fire Extinguishers:

Good Good

j) k)

Condition of welded joints: bin Condition:

Good Good

l)

Walkways, handrails, Ladders for structural integrity:

Good

m)

The entire crane for rust and corrosion:

Good

Page 8 of 8

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF THOROUGH VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Equipment Description: Client: Inspection Location: Crane Type: Crane Manufacture: Model Number: Serial Number: Customer Unit Number: SWL Certificate Number: Inspection Date:

OFFSHORE CRANE SEADRIL WEST CAPPELLA (KBC 1 STB FWD) KNUKLE BOOM NATIONAL OILWELL OC3932KCE T6854 N/A 17 TONS 2902 04/03/2012

Next Date of Examination:

03/09/2012

This is to certify that I did, Examination on the Offshore Crane in accordance with API RP 2D, ISO 4309 and all Statutory requirement as above. The records of examination are true without prejudice for the purpose it was designed for. FIT FOR USE
Inspectors Name/Qualification Signature/Date

STANLEY UNANAM
FID, NSL Module 3, FID, SNT LEVEL II MT, PT, VT, UT Lifting Equipment Insp. 04/03/2012

Serving the Lifting, Rigging and Load Securement Industries

JC International Ltd.