Hazardous Area Connectors for Global Connection Solutions

International

Introduction

A Quality Company

FOR CUSTOMERS WHO DEMAND THE BEST


For those who demand quality, reliability and above all, safety, Hawke International is the obvious choice.

Smarter products
Hawke International has provided peace of mind to contractors, installers and end users for over 50 years. Our innovative range of cable connection and termination products, specifically designed with the customer in mind, have gained worldwide approval and credibility for the testing conditions of hazardous (classified) locations and hostile environments. The customers requirements for sustained safety and reliability under extreme conditions are therefore Hawke's primary objectives. Furthermore, our superior designs allow ease of installation, use long life materials and are manufactured to rigorous quality standards. All this provides the customer with unparalleled benefits of the lowest lifetime cost of purchase.

Worldwide
Located in Manchester, UK, Hawke International has subsidiary locations in Houston, USA and Singapore, along with direct representation in Brazil, the Middle East, Canada and China. Hawke International is supported worldwide by the Hubbell Group along with a global network of agents and distributors.

Product development
Hawke International recognises that the demands of the customer base never stand still and we are therefore committed to the ongoing development of our products and features to provide improved safety, versatility, reliability and ease of use.

First choice
Predominantly used on Offshore and Onshore oil and gas exploration, production and processing facilities. Hawke's products are the 'First Choice' for the world's major oil, gas and petrochemical companies.

A quality company
Hawke International's products are designed and manufactured under a quality system not only complying with ISO 9001 but also with the latest international standards. Rigorous and regular in-house testing ensures that every product manufactured meets the highest quality standards expected by the market.

Termination service
Hawke International has over 50 years of experience in hazardous area connection systems and have a wealth of experienced staff able to provide assistance in the planning and selection of Ex connectors and related products. Termination work can be arranged by Hawke International as part of their connection solution, both at our premises in Manchester or on-site as required. The company have dedicated installation engineers able to offer complete termination services including cable preparation, marking, gland and connector termination and complete unit testing. This simplifies even further the use of Hawke connectors as part of your connection requirements.

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Hazardous Area Connector Range

New connector range contents table

Contents

CONTENTS TABLE
Colour Code/Page 2 3 4-5 6 7-8-9 10 - 11 12 -13 - 14 -15 16 - 17 18 -19 - 20 - 21 22 23 24 25 Description Hazardous area connector range - Common features Hazardous area connector range - Selection overview

Instrum Instrum Instrum Control Control Power Power

Features How it works Inserts and Dual crimp - Order code - Dimensions (Technical) Features Inserts - Order code - Dimensions - Calculations (Technical) Features Inserts - Order code - Dimensions - Calculations (Technical)

Accessories - Short circuit testing, Crimp tool and adaptors/reducers Website technology - Connector selection application, electronic data on CD Rom

Hazardous Area Connectors for Global Connection Solutions

International

Hazardous area cable glands - 501/421, 501/453/Universal, 501/453/RAC, ICG 653/Universal New stainless steel enclosures - EZE box range

SAMPLE OF MAJOR PROJECT SUCCESSES


Project Name
Snohvit Simian/Sienna/Saphire BP Clair Kristin ACG Captain Conoco Immingham CHP Enfield RTM

Owner
Statoil Burullus BP Statoil AIOC Chevron Texaco Conoco Global Power Woodside Energy

Location
Norway Egypt UK Norway UK UK Australia

Application
Connectors used on WOCS Topside electrical surface jumpers Power and communication for BUICS and IWOCS controls containers Topside module hook-up Sub-sea workover station Supply electrical signal to a secondary module beside original platform Installed to actuators which control and monitor gas being induced into the turbines Used on Turret mooring system

Azerbaijan Used on platform drill head for mobility

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

Hazardous Area Connector Range

Common Features

ATEX

There are several innovative features common across the range of Hawke connectors. Despite their highly advanced design and technical features, the range is extremely simple to use and quick to terminate.

Impossible to cross mate

The unique mechanical keying system prevents contact damage and ensures safe use by eliminating the possibility of misconnection of circuits. Machined key and keyway also ensures connector alignment.

Ingress and deluge protected


All Hawke ATEX connectors meet the requirements of IP66 and IP67 to IEC60529. They are also deluge protected to DTS01 offering long term protection in onerous environments.

High reliability contacts

Each pin and socket is fitted with multilam technology to ensure reliable low resistance connection on each coupling.

Retro fit flange option

Each connector plug and receptacle can be fitted with an optional mounting flange, either at point of order or retro fitted as required, allowing easy mounting of the connectors without the need to disassemble the units.

Robust design

Designed and constructed for the most demanding environments, Hawke connectors are durable in almost any environment, requiring no routine maintenance to ensure continued performance.

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Hazardous Area Connector Range

ATEX

Selection Overview

Hawke International connectors are ideal for use in gas hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous benefits in explosive dust environments as well as harsh and hostile non-explosive applications where temporary but safe disconnection of power is critical. Hawke International's Ex range of connectors permit the safe and rapid service, repair and replacement of key plant, provide quick connection to temporary and permament equipment and greatly reduce hook-up time in capital-intensive processes. The Ex range of connectors cover three main application areas: Instrumentation, control and power. For a guide as to which Ex connector may be best suited to an individual application the table below outlines the main variables.

SELECTION OVERVIEW
Connector Type Minimum Number Maximum Number Minimum cross sectional Maximum Maximum Maximum of Pins of Pins area of Conductor mm Conductor mm Voltage Current (amps) 1 3 1 8 60 4 0.14 0.5 50 2.5 35 630 250V 660V 750V* 10 125 780 Live Demate

Instrum Control Power

* Other voltages available on special request.

Instrum

This revolutionary design allows the live mate and de-mating of signal and low power in hazardous areas safely and quickly. The Instrum connector is available with two insert options: the 4-way option will accept cores ranging between 0.5mm and 2.5mm and can operate up to a maximum current of 10A (AC1) at 250V AC & 2.5A (DC1) 60V DC. The 8-way option, designed predominantly for Ethernet applications, will accept cores ranging between 0.14mm and 0.37mm and can carry 1A (AC1) at 60V AC & 0.5A (DC1)60V DC. Instrum connectors include an integral Hawke cable gland for easy termination of both armoured and un-armoured cables.

Control
The 3rd generation of Control connectors include many features and refinements as a result of consumer feedback, which makes them particularly suitable for control and low/medium power applications. The robust stainless steel body can hold up to 60 contacts and will accept conductor sizes ranging between 0.5mm and 35mm, operating up to 125A and 660V. Information on recommended cable glands for use with the Control connectors can be found on page 24 of this catalogue.

Power
The Power range of connectors have been designed specifically for the extremely demanding requirements of higher power applications. Inserts are available with 1 to 4 contacts with a conductor acceptance range of between 50mm and 630mm operating up to 780A and 750V as standard. Other voltages available on special request. Information on recommended cable glands for use with the Power connectors can be found on page 24 of this catalogue.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

Instrum

Features

Instrum
Pre-terminated (Bulkhead) receptacle only

ATEX

Integral keying

Earth continuity clip

5 Position keyed inserts Bulkhead receptacle (BR)

Reversible armour clamp

Connector plug (CP)

Electrical insert

Quick connect thread

Anti-rotation

Versatile LSFZH rear seal

Note: Inline connector - connector plug (CP) and connector receptacle (CR) also available

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Instrum

ATEX
Electrical insert with key Keyed positions

Features

Easy to assemble electrical insert allows crimped or soldered connections.

Secondary keying on the actual insert bodies guarantees contact alignment, preventing pin damage.

Integral keying
Machined key and keyway ensures connector alignment. Unique 5 position insert keying system prevents cross-mating. Unique 4 start ACME thread offers a smooth and quick fully mating action in less than two turns. Earth continuity is achieved via a 360contact clip.

Quick connect

Anti-rotation

Reversible armour clamp


The Instrum incorporates Hawke's proven and patented armour termination method. Two clamping devices are supplied to accommodate different types of armour or braid.

Profiled Spigot and connector body prevent cable rotation, eliminating cable damage.

Versatile LSFZH rear seal

Pre-terminated

Accommodates a wide range of cable sizes and provides highly effective cable grip and ingress protection.

All BR connectors are supplied with pre-terminated tails to suit your requirements.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

Instrum

How it Works

The Instrum

ATEX

The Instrum connectors are designed to provide ease of installation and speed of use whilst providing a flexible, safe and reliable method for mating and disconnection of circuits which are energised.

Stage 1
The two mating halves are easily engaged and disengaged by two full turns of the ACME custom engaging thread, during which time the pins and socket are protected by the Exd flameproof protection concept. The outer shell of the connector combined with the integral Hawke cable gland seal ensure that the internal connections are protected to the Exe increased safety protection concept.
Exe clearances between contacts. These diameters are Exd Flamepaths. Exe clearances between contacts.

Stage 2
Should an ignition occur during de-mating, it is contained by the Exd Flamepath. Arc 'quenching' gap.

During connector engagement and disengagement any sparking of the contacts is contained within an arc quenching section which is housed within the Exd flamepath areas.
Threads still engaged at this point. Once passed the arc quenching gap, the primary protection method becomes Exe.

Stage 3
When the connector halves are disengaged, the socket section is protected to IP30 and must have the protective cap fitted immediately to restore the full Exe increased safety requirements and IP rating. The pins and socket inserts are interchangeable between all three connector components: i.e. Bulkhead receptacle, in-line receptacle and connector plug. In all installations, the "live" side of the connector must always contain the socket insert.
Once de-mated, the protection method is Exe on the socket insert IP30 (IP66 - IP67 with cap fitted).

Pin insert cannot remain energised. Pin and socket inserts are interchangeable between the CP and BR/CR.

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Instrum

ATEX
Front view of socket insert Back view of socket insert Front view of pin insert

Inserts

Back view of pin insert

4 x 0.5 - 1mm 4 x 1.5 - 2.5mm

4 x 0.5 - 1mm 4 x 1.5 - 2.5mm

4 x 0.5 - 1mm 4 x 1.5 - 2.5mm

4 x 0.5 - 1mm 4 x 1.5 - 2.5mm

Front view of socket insert

Back view of socket insert

Front view of pin insert

Back view of pin insert

8 x 0.14 - 0.37mm

8 x 0.14 - 0.37mm

8 x 0.14 - 0.37mm

8 x 0.14 - 0.37mm

Dual crimp
Two crimping locations on the 4 way contacts allow for only two contact sizes to cover a far greater range than conventional contacts. This allows termination of cores ranging between 0.5 and 2.5mm. Contacts must be crimped using the Hawke supplied crimping tool part No. HCT1.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

Instrum

Order Code

ATEX
/N BR1 M B P X 0 4 X A

Instrum

MATERIAL
Nickel Plated Brass Stainless Steel

CODE
N S

CODE
A G

CERTIFICATION
ATEX/IECEx GOST

CONNECTOR STYLE
Connector Plug Flanged Connector Plug Connector Receptacle Flanged Connector Receptacle Bulkhead Receptacle (Fixed Pos 1 Std.) Bulkhead Receptacle (Fixed Pos 2) Bulkhead Receptacle (Fixed Pos 3) Bulkhead Receptacle (Fixed Pos 4) Bulkhead Receptacle (Fixed Pos 5)

CODE
CP FP CR FR BR1 BR2 BR3 BR4 BR5

CODE
U X S

ARMOUR CLAMP SIZE


Unarmoured/Copper Braid (will add outer sheath clamp) N/A (Bulkhead Receptacle) Clamping Ring (2 Rings) 0 - 1.25mm

CODE
4 3 2 8 C

BULKHEAD RECEPTACLE PIN QUANTITIES #


4 (pins 1 - 4 terminated) Std. 4 way* 3 (pins 1, 2 and 3 terminated) 4 way* 2 (pins 1 and 3 terminated) 4 way* 8 (pins 1 - 8 terminated) Std. 8 way Customer specified N/A (for Connector Plug and Receptacle)

BULKHEAD ENTRY THREAD


Metric M20 (Standard) NPT " N/A (for CP or CR)

CODE
M N X

CODE
0

BULKHEAD RECEPTACLE CABLE LENGTH


0.5m (standard) 1m 2m 3m 4m Customer specified N/A (for Connector Plug and Receptacle)

CROSS SECTIONAL AREA


4 x 0.5 - 1mm * 4 x 1.5 - 2.5mm * 8 x 0.14 - 0.37mm

CODE
A B C

1 2 3 4 C X

INSERT TYPE
** Note:- In all installations the "live" side of the connector must always contain the socket insert. Pin Insert ** Socket Insert **

CODE

CODE
P S S X

OUTER SHEATH DIAMETER


Cable Seal (2 Seals) 5.5 - 16mm N/A (Bulkhead Receptacle)

* 4 way Bulkhead Receptacle will always be pre-terminated with 1.5mm conductors, irrespective of cross sectional area. # Bulkheads also include an additional earth lead.

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Instrum

ATEX
102-110 11.5 10 112-128 8 28-36

Dimensions

30

29.5

29.5

27 A/F Optional mounting flange for CP & CR 27 A/F

Optional cable clamp for CP & CR

Connector plug

Connector receptacle
M20 = 15 " NPT = 20 " NPT = 20 20

4 Holes 6.5 Equispaced on a 43

10

75.5

Mounting flange

Bulkhead receptacle

Technical Data
Explosion Protection II 2 G Exde IIC ExtD T85C A21 ATEX Exde IIC ExtD T85C A21 IECEx Explosion Protection II 2 G Exde IIC ExtD T85C A21 ATEX Exde IIC ExtD T85C A21 IECEx

Ambient Temperature - 40C to + 60C Baseefa 06 ATEX 0061X Certification IECEx BAS06. 0018X Voltage AC 250V Current AC EN 60947-4-3 10A (AC21) Current AC EN 60947-4-1 10A (AC1) Current AC EN 60947-4-1 1A (AC3) Frequency 50/60 Hz Ratings 4 Way Power Factor 0.9 Voltage DC 60V Current DC EN 60947-4-3 2.5A (DC21) Current DC EN 60947-4-1 2.5A (DC1) Current DC EN 60947-4-1 0.5A (DC3) 10 amp without thermal protection Fuse Rating 4 Way 20A gL with thermal protection On load 150 Maximum No. of make &
break operations (EN61984)

Ambient Temperature - 40C to + 60C Baseefa 06 ATEX 0061X Certification IECEx BAS06. 0018X Voltage AC 60V Current AC EN 60947-4-3 1A (AC21) Current AC EN 60947-4-1 1A (AC1) Current AC EN 60947-4-1 0.1A (AC3) Frequency 50/60 Hz Ratings 8 Way Power Factor 0.9 Voltage DC 60V Current DC EN 60947-4-3 0.5A (DC21) Current DC EN 60947-4-1 0.5A (DC1) Current DC EN 60947-4-1 0.1A (DC3) 2 amp without thermal protection Fuse Rating 8 Way 5A gL with thermal protection On load 150 Maximum No. of make &
break operations (EN61984)

IP Rating Storage Temperature

Off load 500 IP66, IP67 and DTS01 deluge protected.


Note: Caps to be fitted to maintain IP ratings when the connector halves are separated.

IP Rating Storage Temperature

Off load 500 IP66, IP67 and DTS01 deluge protected.


Note: Caps to be fitted to maintain IP ratings when the connector halves are separated.

-50C to +70C

-50C to +70C

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

M20 " NPT " NPT

29.5

29.5

55

Control

Features

Control

ATEX
Threaded bulkhead entry

Insert keying position

Acme thread at mating interface

Key fixing position

Keyway tube

Bulkhead-BR

Internal earth

Fully inspectable flameproof barrier

Easy fieldwireable

Slotted spacer tube

Connector plug-CP

External earth point

Running coupler

Note: Inline connector - connector plug (CP) and connector receptacle (CR) also available

10

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Control

ATEX
Easy fieldwireable
Pin and socket inserts are numbered front and back to assist wiring and avoid termination errors. Crimp and solder inserts available.

Features

Keyway tube

Provides an extended installation keyway, which assists connector assembly by making pin/socket insertion quick and easy.

Spacer tube
Improves accessibility for soldering/crimping conductors, as the spacer tube is retrofitted once electrical termination is complete. The unique visual 5 position insert keying system (3 on Ex16) along with the integral machined keyways prevent contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

Keying position

Running coupler

Acme thread at mating interface

Allows the connector to be installed onto a pre-assembled cable gland.

Unique ACME thread offers a smooth and quick fully mating action.

Fully inspectable flameproof barrier

Threaded bulkhead

Provides direct inspection of the flameproof seal and offers users the peace of mind that the connector is safe for installation.

The threaded bulkhead connector utilises industry standard threads and also incorporates an integral 'o' ring seal.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

11

Control

Inserts

ATEX
Ex16-4 x 1.5 Ex25-4 x 1.5 Ex25-9 x 1.5 Ex25-12 x 1.5 Ex25-4 x 2.5 Ex25-7 x 2.5 Ex25-4 x 6

Ex16-3 x 1.5

TABLE
Ex32-12 x 1.5 Ex32-19 x 1.5 Ex32-10 x 2.5 Ex32-12 x 2.5 Ex32-4 x 6
Insert Size Internal Diameter of cup (mm) Nominal Soldered Crimped

1.5mm 2.5mm 6mm

2 3 3.5 7 7 8 8

2 3 3.2 4 5 6.5 8.3

Ex32-6 x 6

Ex32-3 x 10

Ex32-4 x 10

Ex32-3 x 16

Ex32-4 x 16

10mm 16mm 25mm 35mm

Ex40-24 x 1.5

Ex40-30 x 1.5

Ex40-19 x 2.5

Ex40-4 x 25

Ex40-4 x 35

Ex50-37 x 1.5

Ex50-27 x 2.5

Ex50-37 x 2.5

Ex63-49 x 1.5

Ex63-60 x 1.5

INSERT SELECTION TABLE


Configuration Shell Size 16 3 x 1.5mm + Earth 4 x 1.5mm + Earth Shell Size 25 4 x 1.5mm + Earth 9 x 1.5mm + Earth 12 x 1.5mm + Earth 4 x 2.5mm + Earth 7 x 2.5mm + Earth 4 x 6mm + Earth Shell Size 32 12 x 1.5mm + Earth 19 x 1.5mm + Earth 10 x 2.5mm + Earth 12 x 2.5mm + Earth 4 x 6mm + Earth 6 x 6mm + Earth 3 x 10mm + Earth 4 x 10mm + Earth 3 x 16mm + Earth 4 x 16mm + Earth Shell Size 40 24 x 1.5mm + Earth 30 x 1.5mm + Earth 19 x 2.5mm + Earth 4 x 25mm + Earth 4 x 35mm + Earth Shell Size 50 37 x 1.5mm + Earth 27 x 2.5mm + Earth 37 x 2.5mm + Earth Shell Size 63 49 x 1.5mm + Earth 60 x 1.5mm + Earth -

Note: Inserts for use in bulkhead receptacles are solder termination only for contact sizes of 6mm and above.

All Hawke Control Contr connectors have a maximum working voltage of 660V DC (660V AC) as standard. Other voltages avilable on special request.
To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application. All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

12

www.ehawke.com

Connection Solutions

International

HWK51 August '08

Control

ATEX
Control / Exd 32 S CP V 19
x

Order Code

1.5

FLFPC

PROTECTION
Flameproof

CODE
Exd

CODE
A G

CERTIFICATION
ATEX/IECEx GOST

SHELL SIZE
16 25 32 40 50 63

CODE
16 25 32 40 50 63

CODE
FL FPC FRC PPC PRC

ACCESSORIES
Mounting Flange Flameproof Plug Cap Flameproof Receptacle Cap Environmental Plug Cap Environmental Receptacle Cap

CODE
S C X

TERMINATION STYLE
Solder * Crimp * No Insert

MATERIAL
Brass Stainless Steel (as standard)

CODE
B S

CODE
P S X

CONTACT TYPE
Pin Socket No Insert

CONNECTOR STYLE
Connector Plug Connector Receptacle Bulkhead Receptacle

CODE
CP CR BR

CODE
1.5 2.5 4 6 10 16

CONTACT TYPE
1.5 mm 2.5 mm 4 mm 6 mm 10 mm 16 mm 25 mm 35 mm No Insert NUMBER OF CONTACTS See Insert Selection Chart

KEYING SYSTEM
Fixed Keying Variable Keying

CODE
F V

* Note: Inserts for use in bulkhead receptacles are solder termination only for contact sizes of 6mm and above.

25 35 X

Hawke International does not recommend the use of their ControlEx Connectors in applications where rigid PVC/SWA/PVC power cabling (typically to BS 6346 standards) is used in portable/semi-portable applications.

CODE
X

No Insert

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

13

Control

Dimensions
External earth X B 12 A mating face

ATEX
E 12 X External earth D W Gland entry thread V C F

Connector plug
Gland entry thread V

Optional mounting flange. Details on request.

Connector receptacle
M G H

Thread L

Bulkhead receptacle
ICG 653/Universal Cable Gland

S R mating face

The flameproof cap must be fitted to the connector before the power is restored to the disconnected circuit.

Flameproof receptacle cap

Flameproof plug cap

The receptacle cap and plug cap are available in acetal and provide an IP rating of IP66/67. They may only be used when the socket or plug is not re-energised following disconnection.

HAWKE Ex SERIES DIMENSIONS (MM)


Dimension
A B C D E F G H *Thread L (1.5mm Pitch) M N A/F P R S T U **Thread V(1.5mm Pitch) W

Ex16
115 92 33 37 119 32 15 11 M25 54 36 24 36 59 29 35 M16 55

Ex25
143 120 41 49 146 45 15 11 M32 54 46 38 36 59 41 35 M25 65

Ex32
145 122 46 57 149 51 15 11 M40 56 55 42 36 59 47 35 M32 72

Ex40
145 122 59 65 149 59 15 11 M50 56 65 52 36 59 55 35 M40 82

Ex50
143 120 66 76 146 70 15 11 M63 56 80 64 36 59 67 35 M50 92

N A/F

For connector plugs and connector receptacles cable glands are required to terminate incoming cables. These can be selected from our cable gland catalogue or our website. These glands include but are not restricted to 501/453/Universal and the ICG 653/Universal. See page 24. For portable application Hawke recommend the ICG 653/Universal cable gland.

Ex63 143
120 83 90 146 83 15 11 M75 56 95 76 36 59 79 35 M63 108 60

X 45 60 62 62 60 *Bulkhead entry thread L can be adapted to other sizes. This may affect the overall length of unit. Contact Hawke International for details. **Thread entry V can be adapted to suit smaller sizes on request. Contact Hawke International for details.
To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application. All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

14

www.ehawke.com

Connection Solutions

International

HWK51 August '08

Control

ATEX

Calculations

To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the arrangement. This ensures that the arrangement does not exceed the maximum permitted temperature classification with regard to the upper ambient temperature for the area of installation. (please refer to table 1 for the maximum allowable dissipated wattage per connector size).

TABLE 1
Connector Size Upper Ambient Upper Ambient Upper Ambient Temperature of +40C Temperature of +50C Temperature of +60C Temperature Class Temperature Class Temperature Class T6 T5 T6 T5 T6 T5 Contact Size

TABLE 2
Combined Cable and Contact Resistance (Ohms) Soldered Crimped Contact Current Rating

Ex16 Ex25 Ex32 Ex40 Ex50 Ex63

5W 8W 10.5W 12W 13W 17W

7W 11W 14.5W 17W 20W 29W

4W 6W 8W 9W 10W 13W

6W 10W 12W 14W 17W 24W

2.6W 4W 5.4W 5.9W 6.5W 8.5W

4.6W 7W 9W 10.5W 12.5W 17W

1.5mm 2.5mm 6mm 10mm 16mm 25mm 35mm

0.0166 0.0102 0.0047 0.0027 0.0018 0.0012 0.0009

0.0173 0.0109 0.0054 0.0033 0.0024 0.0018 0.0015

10 amps 17 amps 30 amps 78 amps 78 amps 125 amps 125 amps

Maximum allowable dissipated wattage

Dissipated wattage calculation


Equation definitions W = Dissipated wattage factor of the connector

Other ambient temperature options can be extrapolated from table 1 above, or contact Hawke International for more information.

N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket). I = The current requirement per contact. (Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2).

R = The combined cable and contact resistance (see table 2). Values pertinent to these definitions must then be input into the following equation to calculate the dissipated wattage (W) of your chosen arrangement:

W = N x I x R

(Note: The results must be lower than the maximum figure shown in table 1 for the appropriate temperature class and ambient temperature). e.g. T6 40C ambient application with 9 x 1.5mm conductors, running at 7 amps. N = 9 contacts I = 7 amps R = 0.0166 (1.5mm soldered combined cable and contact resistance)

Therefore W = 9 x 49 x 0.0166 = 7.32 watts.


Therefore an Ex25 Connector should be specified for this application as the shell size can accommodate the required 9 x 1.5mm pin/socket inserts (see page 12 - Inser t Selection Table) and the resultant dissipated wattage (7.32 watts) is below the maximum permitted 8 watts (see table 1). This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selected connector 1 and the maximum allowable current within the upper ambient temperature of your location 2 1
N= W R x I

I=

W NxR

(Note: The result of equation 2 must not exceed the maximum current rating of the contacts (see table 2).
Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40C.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

15

Power

Features

Power

ATEX
External Earth

Connector receptacle-CR

Acme thread at mating interface

Metal keyway

Running coupler Crimp/solder cable connection

Multilam contact technology

Variable keying position

Connector plug-CP

Internal earth

16

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Power

ATEX
Running coupler Easy fieldwireable

Features

Allows the connector to be installed onto a pre-assembled cable gland.

Insert assembled outside connector shell to assist wiring and allow greater flexibility.

Keying position

The unique visual 5 position insert keying system along with the integral machined keyway prevents contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

Acme thread at mating interface

Internal earth

Unique ACME thread offers a smooth and quick fully mating action.

Internal earth fitted as standard. Sized to suit cables earthing facility.

Multilam technology

Tried and tested multiple high contact force, low resistance multilams used in all moving contacts.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

17

Power

Inserts

ATEX

Ex32-1 x 50

Ex32-1 x 70

Ex32-1 x 95

Ex32-1 x 120

Ex32-1 x 150

Ex40-1 x 185

Ex40-1 x 240

Ex50-3 x 50

Ex50-3 x 70

Ex50-4 x 50

Ex50-4 x 70

Ex50-1 x 185

Ex50-1 x 240

Ex63-3 x 95

Ex63-3 x 120

Ex63-3 x 150

Ex63-4 x 95

Ex63-4 x 120

Ex63-4 x 150

Ex63-1 x 300

Ex63-1 x 400

Ex75-3 x 185

Ex75-3 x 240

Ex75-4 x 185

Ex75-4 x 240

Ex75-1 x 500

Ex75-1 x 630

INSERT SELECTION TABLE


Configuration Shell Size 32 1 x 50mm + Earth 1 x 70mm + Earth 1 x 95mm + Earth 1 x 120mm + Earth 1 x 150mm + Earth Shell Size 40 1 x 185mm + Earth 1 x 240mm + Earth Shell Size 50 3 x 50mm + Earth 3 x 70mm + Earth 4 x 50mm + Earth 4 x 70mm + Earth 1 x 185mm + Earth 1 x 240mm + Earth Shell Size 63 3 x 95mm + Earth 3 x 120mm + Earth 3 x 150mm + Earth 4 x 95mm + Earth 4 x 120mm + Earth 4 x 150mm + Earth 1 x 300mm + Earth 1 x 400mm + Earth Shell Size 75 3 x 185mm + Earth 3 x 240mm + Earth 4 x 185mm + Earth 4 x 240mm + Earth 1 x 500mm + Earth 1 x 630mm + Earth -

All Hawke Power

connectors have a maximum working voltage of (750V AC).

Other voltages and contact configurations also available.

18

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Power

ATEX
Power /Exd 32
CODE
Exd

Order Code

CP

50
CODE
A G

FLFPC A
CERTIFICATION
ATEX/IECEx GOST

PROTECTION
Flameproof

SHELL SIZE
32 40 50 63 75

CODE
32 40 50 63 75

CODE
FL FPC FRC PPC PRC

ACCESSORIES
Mounting Flange * Flameproof Plug Cap Flameproof Receptacle Cap Environmental Plug Cap Environmental Receptacle Cap

MATERIAL
Brass Note: (for single core cables, Brass must be used) Stainless Steel (as standard) Nickel Plated Brass

CODE
B S N

CODE
P S

CONTACT TYPE
Pin Socket
MAXIMUM CONDUCTOR ACCEPTANCE DIAMETER (mm)**

CONNECTOR STYLE
Connector Plug Connector Receptacle

CODE
CP CR

CODE
50 70 95 120 150 185 240 300 400 500 630 X

CONTACT TYPE

50mm 70mm 95mm 120mm 150mm 185mm 240mm 300mm 400mm 500mm 630mm No Insert

9.5 11.5 13.0 14.5 16.5 18.5 20.5 25.0 29.0 32.0 38.0

INTERNAL EARTH SIZE


50mm 70mm 95mm 120mm 150mm 185mm 240mm Note: (should be at least 50% of phase conductor size)
* Note: Only the connector receptacle (CR) can be flange mounted.

CODE
A B C D E F G

** Contact Hawke International if conductor is larger than that stated.

CODE

NUMBER OF CONTACTS See Insert Selection Chart

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

19

Power

Dimensions
External earth B A mating face

ATEX
E X 16 External earth F W Gland entry thread V C

Gland entry thread V

Connector plug

Optional mounting flange. Details on request

Connector receptacle

For connector plugs and connector receptacles cable glands are required to terminate incoming cables. These can be selected from our cable gland catalogue or our website. These glands include but are not restricted to 501/453/Universal and the ICG 653/Universal. See page 24. For portable application Hawke recommend the ICG 653/Universal cable gland. The flameproof cap must be fitted to the connector before the power is restored to the disconnected circuit.

ICG 653/Universal Cable Gland

S T F R mating face

The receptacle cap and plug cap are available in Acetal and provide an IP rating of IP66/67. They may only be used when the socket or plug is not re-energised following disconnection.

Flameproof receptacle cap

HAWKE Ex SERIES DIMENSIONS (MM)


Dimension
A B C D E F P R S T U Thread V (1.5mm Pitch) W X *Other entry threads also available.

Ex32P
228 168 60 73 251 67 48 60 75.5 61 68.5 M32* 100 184

Flameproof plug cap

Ex40P
228 168 66 79 251 73 55 60 75.5 68 68.5 M40* 106 184

Ex50P
228 168 76 89 251 82.5 65 60 75.5 77 68.5 M50* 116 184

Ex63P 228
168 89 102 251 95 78 60 75.5 90 68.5 M63* 129 184

Ex75P 238
178 101 114 261 108 90 60 76 102 68.5 M75* 141 194

20

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

Power

ATEX

Calculations

To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the arrangement.This ensures that the arrangement does not exceed the maximum permitted temperature classification with regard to the upper ambient temperature for the area of installation. (please refer to table 1 for the maximum allowable dissipated wattage per connector size).

TABLE 1
Connector Size Upper Ambient Temperature of +40C Temperature Class T6 T5 Upper Ambient Temperature of +50C Temperature Class T6 T5 Upper Ambient Temperature of +65C Temperature Class T6 T5 Contact Size

TABLE 2
Combined Cable and Contact Resistance (Ohms) Contact Current Rating

Ex32P Ex40P Ex50P Ex63P Ex75P

20.5W 22.5W 25.8W 30.2W 36.3W

27.5W 30.5W 35.3W 41.5W 49.5W

15.75W 17.5W 20W 23.5W 28.25W

26W 28W 32.25W 37.7W 45.25W

7.5W 8.7W 10W 11.7W 14W

15.75W 17.5W 20W 23.5W 28.25W

50mm 70mm 95mm 120mm 150mm 185mm 240mm 300mm 400mm 500mm 630mm

514 387 283 239 202 170 144 82 67 54 45

190amps 240amps 290amps 340amps 385amps 440amps 520amps 590amps 670amps 720amps 780amps

Maximum allowable dissipated wattage

Dissipated wattage calculation


Equation definitions W = Dissipated wattage factor of the connector

Other ambient temperature options can be extrapolated from table 1 above, or contact Hawke International for more information.

N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket). I = The current requirement per contact. (Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2).

R = The combined cable and contact resistance (see table 2). Values pertinent to these definitions must then be input into the following equation to calculate the dissipated wattage (W) of your chosen arrangement:

W = N x I x R

(Note: The results must be lower than the maximum figure shown in table 1 for the appropriate temperature class and ambient temperature). e.g. T6 40C ambient application with 4 x 95mm conductors, each running at 160 amps. N = 4 contacts

Therefore W = 4 x 25600 x 0.000283 = 28.9 watts.

I = 160 amps

R = 0.000283

(95mm combined cable and contact resistance)

Therefore an Ex63P Connector should be specified for this application as the shell size can accommodate the required 4 x 95mm pin/socket inserts (see page 18 - Insert Selection Table) and the resultant dissipated wattage (28.9 watts) is below the maximum permitted 30.2 watts (see table 1). This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selected connector 1 and the maximum allowable current within the upper ambient temperature of your location 2 1
N= W R x I

I=

W NxR

(Note: The result of equation 2 must not exceed the maximum current rating of the contacts (see table 2).
Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40C.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

21

Accessories

Short Circuit Testing

ATEX

All contact sizes in the Hawke connector range have been short circuit tested. For further information please contact Hawke Internationals Technical department.

Crimp Tool

Instrum

inserts and Control

inserts up to 2.5mm must be terminated using the Hawke HCT Crimping Tool.

Adaptors/Reducers
Adaptor Reducer
M16 M20 M25

ADAPTOR AND REDUCER SELECTION TABLE


Male Thread Metric
M16 M20 M25 M32 M40 M50 M63 M75 " " 1"

NPT
1" 1" 2" 2" 3"

Metric Female Thread NPT

M32 M40 M50 M63 M75 " " 1" 1" 1" 2" 2"

Adaptor

Reducer

3"

22

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

State of the Art - Website Technology

ATEX

www.ehawke.com

Our website has now been updated to include the NEW Members Area. This area is all about solving problems and getting quick access to relevant Hawke product information. This has been designed to provide on line assistance when selecting and installing our products, utilising our new state of the art selection software. Within our members area you will have access to: Frequently asked questions section (FAQ's). Cable gland selection application. Cable gland installation training videos. Connector selection application. Hawke catalogue downloads (PDF format).

Connector selection application


State of the art, rich internet application for rapid and easy selection of connectors. All wattage calculations etc. are worked out for you. All that is required is for the user to input the cable details. Projects can be saved and edited. Completed projects can be sent to Hawke International for quoting purposes.

Step 1

Step 2

Step 3

Step 4

Shell and insert size selection.

Accessories and keying system selection.

Cable gland plus adaptor and reducer selection.

This screen displays the connector, gland and any adaptors/reducers required.

Electronic data on CD Rom CD Rom


Hazardous Area Connectors for Global Connection Solutions catalogue in PDF format. The Instrum , Control and Power connector presentation.

Paper catalogue
Hazardous Area Connectors for Global Connection Solutions

International

Information on the NEW Instrum , Control and Power connectors. Connector accessories - adaptors, reducers, crimp tool and insert tool. Brief description of connector selection application. Cable glands. Eze stainless steel enclosures.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

23

Hazardous Area Cable Glands

Cable Glands
501/421
'H' Metric Entry 'G' Approx(Compressed Length)

ATEX
The 501/421 cable gland provides a seal on the outer cable sheath and is intended for use on non-armoured elastomer and plastic insulated cables. The cable gland is dual certified Exd and Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.

Entry Thread

'B'

501/453/Universal
The 501/453/Universal cable gland provides a flameproof seal on the inner cable sheath and an IP seal on the outer sheath. It utilises reversible armour clamp (RAC) technology and can therefore accommodate all types of armoured or braided cables (W, X and Z). The cable gland is particularly suitable for use on 'soft' inner cable sheaths that exhibit "Cold Flow" characteristics as the inner diaphragm seal will not damage the cable bedding. The cable gland is dual certified Exd and Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
'H' Metric Entry Deluge Boot 'G' Approx (Compressed Length) Diaphragm Seal Armour/Braid 'C'

Entry Thread

'A'

501/453/RAC
'H' Metric Entry 'G' Approx (Compressed Length) Armour/Braid 'C'

The 501/453/RAC cable gland provides a flameproof seal on the inner cable sheath and an IP seal on the outer sheath. It utilises reversible armour clamp (RAC) technology and can therefore accommodate all types of armoured or braided cables (W, X and Z). The cable gland is dual certified Exd and Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.

Entry Thread

'A'

'B'

ICG 653/Universal
The ICG 653/Universal cable gland provides a flameproof barrier seal on the individual insulated cable cores and prevents entry of the products of an explosion into the cable's surrounding environment. It also provides an IP seal on the cable outer sheath. The cable gland is suitable for cables that are not effectively filled and for cables with a 'soft' inner sheath that exhibit "Cold Flow" characteristics. The cable gland is dual certified Exd and Exe and is suitable for installations in Zone 1 (21) and Zone 2 (22) hazardous areas, where the enclosure is greater than 2 litres in volume and contains an ignition source and requires IIC apparatus.
'H' Metric Entry 'G' Approx (Compressed Length) Inspectable Deluge Armour/Braid Compound Boot 'C'

Entry Thread

'D'

'E'

24

www.ehawke.com

Connection Solutions

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

International

HWK51 August '08

'B'

'B'

New Stainless Steel Enclosures

ATEX
Hawke International is renowned for the development of easy to install and inspect, innovative hazardous area products. To add to it's existing product portfolio, Hawke has introduced the unique EZE range of stainless steel Exe ATEX certified terminal boxes. This product is available in three sizes, the EZE 22, EZE 42 and the EZE 62. Reliability and quality These products are manufactured to the highest quality levels from the most suitable materials to provide the same long term reliability normally associated with Hawke International products in safety critical harsh and hazardous, oil, gas and petrochemical environments.

EZE Box Range


Installation made easy

Commitment to customers
This new range is a result of consultations with customers to determine what they require from electrical equipment to reduce the installation and inspection times and to make the installation work easier to perform. This consultation proved to be of particular importance as our customers terminal box installation practices have changed over the years with revised emphasis on base entry cabling for terminal boxes. This detail has been considered carefully and implemented into the new EZE range of enclosures.

Three enclosure sizes. Exe II T5 or T6/ II 2 GD BASEEFA ATEX certified. -40C to +80C ambient temperature range. Electro-polished grade 316 stainless steel. High and low temperature silicone gaskets. IP66 and BASEEFA witnessed DTS01 deluge tested. Unique flip top lid. Lid prop holds lid up during installation. Lid can be used as a weather shield during installation or removed to assist wiring. Unequalled front and side access for wiring and inspection. 50% reduction in installation time. Designed specifically for base cable entries. Easily removable, raised terminal rails. One size modular gland plate fits all boxes. Quick release gland plate has two easily accessible fixing screws. Padlockable lid feature. Captive lid and gland plate fixing screws. Available as a component approved empty enclosure.

International

HWK51 August '08

To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

www.ehawke.com

Connection Solutions

25

International

Agent/Distributor

www.ehawke.com
All copyright reserved-Hubbell Ltd 2008. This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.

To the best of our knowledge the information contained in this brochure, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.

www.ehawke.com

Connection Solutions
Hawke International is a division of Hubbell Ltd. A member of the Hubbell Group of Companies. Registered No. 669157 in England. Registered Office: Mitre House, 160 Aldersgate Street, London EC1A 4DD.

UK Office Hawke International Oxford Street West, Ashton-Under-Lyne, Lancashire OL7 0NA. UK. Tel: +44 (0) 161 830 6695 Sales: +44 (0) 161 830 6698 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke.com www.ehawke.com

USA Office Hawke International 4140 World Houston Parkway Suite 130 Houston, TX 77032 Tel: +1 (281) 445 7400 Wats: (800) 354 9189 Fax: +1 (281) 445 7404 E-mail: america@ehawke.com www.ehawke.com

Singapore Office Hawke International 130 Joo Seng Road #03-02 Olivine Building Singapore 368357 Tel: +65 6282 2242 Fax: +65 6284 4244 E-mail: asia@ehawke.com www.ehawke.com

HWK51 August '08

Anda mungkin juga menyukai