PO Box 60276 / Midland, Texas USA 79711 PHONE 432-561-5393 / FAX 432-561-5395 Email: contact@newtechsystems.com www.newtechsystems.

com

EQUIPMENT PRICE QUOTATION


Date: To: Email: June 14, 2011 Nelly V. Export-Houston-TX nellyvexport@att.net Quote No.: Attention: Phone: 061411JA1 Nelly Geddes 281.987.2160

TubePRO 554P STATIIONARY 4--FUNCTIION EMII IINSPECTIION SYSTEM TubePRO 554P STAT ONARY 4 FUNCT ON EM NSPECT ON SYSTEM
(Inspection Capacity: 1.315 to 5 O.D. Tubulars w/coupling)
The Computerized EMI TubePRO-554-P is designed to perform a quality inspection of new & used oilfield tubulars up to 5 O.D. to the most stringent industry standards & specifications. The TubePRO is quickly serviced and maintained with minimum downtime. A typical set of stationary components consists of the electronics cabinet, computer, main inspection desk, center-section, inspection heads, hydraulic power unit, & conveyors. Here are some key features & details included in a standard system: SKID-MOUNTED INSPECTION CENTERSECTION is constructed of a heavy-duty aluminum mainframe with remote-controlled hydraulic actuator jacks to raise & lower to pipe size being inspected. Mounted on the mainframe is a transverse inspection coil, longitudinal rotating head with drive-train & protective guard, slip rings, 3 pinch roller modules, electronic photo-eyes & on-board hydraulic system. Rollers are actuated by electronic photo eyes. ELECTRONICS PACKAGE is PC Based and controlled by computer with mouse. Computer saves inspection data to disk and generates customized inspection reports as specified by operator. Windows-Based software provides easy data transfer, storage and recall. Inspection results can be recalled from hard drive or from floppy and can be viewed on any Windows-compatible computer. All settings for transverse, longitudinal and magnetic wall system are adjusted on the computer by clicking a mouse. A high speed desktop PC with 17 flat panel screen is included. TRANSVERSE SYSTEM Transverse inspection magnetizing coil is designed for high gauss output & heat dissipation, resulting in maximum detection of transverse-oriented flaws. Inspection heads are the air-actuated type for excellent shoe ride & longevity, with quick disconnects for detector hook-up. Air-Actuated heads sizes 1.660 to 5 are actuated open and shut with standard photo-eyes or Optional PLC. The inspection results are displayed real-time on computer color monitor (High speed computer and flat panel monitor included). Choice of 5 Shoe Heads included, other sizes optional. LONGITUDINAL SYSTEM Inspection of longitudinally-oriented flaws is accomplished with a high-speed rotating head with multiplexed signal processing system. Signal is transmitted from the rotating head through a high-tech slip ring to the computerized electronics system. Head is rotationally powered by a variable-speed DC electric motor, controlled by operator at control desk. Rotating detector shoes are quick-disconnect type with military-spec plugs, mounted to centrifugal-motion arms, allowing pipe to move forward or back. The inspection results are displayed in real-time on computer monitor. Radius shoes included for sizes, 2-3/8, 2-7/8, 3-1/2, four (4) flat shoes included for larger sizes. MAGNETIC WALL THICKNESS MONITORING SYSTEM (TRUE WALL) New Techs exclusive TRUE WALL solid state hall effects wall monitoring system eliminates the need for radioactive gamma systems as with older units. Stationary sensor configuration is situated around the tube to give excellent coverage and accuracy and has the ability to detect gradual wall loss and the ability to statically park on a wall loss to reduce prove-up time. Results are displayed in real-time on computer monitor. DIGITAL MAGNETIZING COIL POWER SUPPLIES for the transverse & longitudinal coils are high-tech constant current modules which electronically selfadjust when current varies. This feature contributes towards more consistent & repeatable inspection results.

TubePRO 554-P Stationary 4-Function EMI Inspection System

Page 1

TubePRO 554--P Sttattiionarry 4--Functtiion EMII IInspecttiion Systtem TubePRO 554 P S a ona y 4 Func on EM nspec on Sys em
Quote No: 061411JA1 To: Nelly V. Export-Houston-TX Attention: Nelly Geddes

New Tech Systtems USA New Tech Sys ems USA

PIPE CONVEYOR SYSTEM is to accommodate pipe sizes 1.315 to 5 , Range II & III lengths. Heavy-duty steel channel frames with welded supports & cross-members support and convey pipe on large urethane v-rollers & industrial pillow block bearings. Rollers are hydraulically-driven, variable speed. Conveyor channel frames are primed & painted to resist rust & corrosion and should be mounted to customers furnished vertical pedestals. All hydraulic lines are stainless steel and are mounted inside of channel webbing to resist damage. Hydraulic solenoid valves and manifolds are mounted to conveyor channels on each side closest to center-section & hydraulic power unit. Dimensions: 80 ft. total length/with 3 ft. walkways between sections (4 sections x 18.5 ft. long). They include base plates for easy mounting to floor. LOADER/UNLOADER ARMS are mounted into the conveyor frame work. Pipe loads from one direction and unloads one direction off the outgoing conveyors. (Bi-Directional pipe un-loaders are available, see Options below) HYDRAULIC POWER UNIT is skid-mounted with dual pumps, 10 hp electric motor with pump, tank, filters and pressure/return hoses. Motor magnetic starter included for 440/380/220 volt, 50 or 60hz electric power. (Customer to furnish power) OPERATIONS PANEL Located on the operators desk, this panel includes switches for pinch rollers, air actuated shoe heads, loader and un-loader arm, auto manual control, emergency on/off kill switch and rotating head speed with tachometer. This panel is prewired to the center-section for easy installation and can be mounted to any operator desktop. OPERATIONAL TRAINING 3 DAYS training included for up to 5 operators at New Tech Facility/Midland, TX USA Please inquire for quote for on-site training.

TOTAL PRICE for above Standard Basic System: (FOB Midland, Texas USA): (Not Including Option Items Listed Below):
OPTIONAL ITEMS Item 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Part No. Description Standard, 1.315 TV/LONG/WALL 14 Long with Certification (No I.D. Notch) Standard, 1.660 TV/LONG/WALL 14 Long with Certification (No I.D. Notch) Standard, 1.900 TV/LONG/WALL 14 Long with Certification (No I.D. Notch) Standard, 2.062 TV/LONG/WALL 14 Long with Certification (No I.D. Notch) Standard, 2-3/8 TV/LONG/WALL 14 Long with Certification Standard, 2-7/8 TV/LONG/WALL 14 Long with Certification Standard, 3 TV/LONG/WALL 14 Long with Certification Standard, 4 TV/LONG/WALL 14 Long with Certification Standard, 4 TV/LONG/WALL 14 Long with Certification Standard, 5 TV/LONG/WALL 14 Long with Certification Standard, 5-1/2 TV/LONG/WALL 14 Long with Certification Head, AA 1.315 TV/WALL Head, AA 1.660 TV/WALL Head, AA 1.900 TV/WALL Head, AA 2.062 TV/WALL Head, AA 2.375 TV/WALL Head, AA 2.875 TV/WALL Head, AA 3.50 TV/WALL Head, AA 4 TV/WALL Head, AA 4.50 TV/WALL Head, AA 5 TV/WALL Head, AA 5.50 TV/WALL

US $ 185,000.00

52304 52305 52306 52307 52308 52309 52310 52329 52330 52331 52332 51170 51171 51172 51173 51174 51175 51176

Price (each) US$ SPECIAL ORDER SPECIAL ORDER SPECIAL ORDER SPECIAL ORDER $1,250.00 $1,250.00 $1,250.00 $1,450.00 $1,450.00 $1,450.00 $1,700.00 $2,375.00 $2,375.00 $2,375.00 $2,375.00 $2,875.00 $2,875.00 $2,875.00 $2,875.00 $2,875.00 $2,875.00 $2,875.00

TubePRO 554-P Stationary 4-Function EMI Inspection System

Page 2

TubePRO 554--P Sttattiionarry 4--Functtiion EMII IInspecttiion Systtem TubePRO 554 P S a ona y 4 Func on EM nspec on Sys em
Quote No: 061411JA1 To: Nelly V. Export-Houston-TX Attention: Nelly Geddes

New Tech Systtems USA New Tech Sys ems USA

ADDITIONAL OPTIONAL ITEMS Item 23 24 25 26 27 28 29 30 31 32 33 Description Grade Comparator System with 8 Coil Bi-Directional Load and Unload Arms Additional Conveyors, per linear foot Price (each) $US $6,500.00 $7,800.00 ea. pair $575.00 per ft. $14,500.00 CALL FOR QUOTE CALL FOR QUOTE $54,000.00 $18,000.00 per set $4,500.00 CALL FOR QUOTE $5,050.00 per set

Paint Defect Marking System, includes wiring, encoder & software upgrades with ONE paint marking head: (additional paint marking heads @ $5,800.00 Each)
Portable Unit on Trailer Ultrasonic Wall Measure System Inspection Building (Operator Compartment) *see below Auto-Load Racks (2 per load rack set / uses existing hydraulic power unit) Demag System Transformer 380-220-110/Hz for electronics and center-section 1 Set consisting of 6-Clamp on Rollers for inspection of small pipe

*INSPECTION BUILDING (OPTIONAL) is skid-mounted. It is constructed of industrial-grade materials with heavy steel frame and skid base. Steel walk-in door is located on the operator side, while a heavy duty roll-up overhead door is located on the center-section side. A divider wall with large operator viewing window is located between the operators compartment and center-section area. Building is heavily insulated for cold and hot weather, rated for extreme outdoor application. Floors are covered with aluminum diamond safety plate, operators compartment is air conditioned. Both compartments are equipped with safety fluorescent lamps, 110V outlets installed inside and outside of building for operation or power tools, optional equipment, etc. A 110/220V electrical breaker box is installed inside building for easy access to all electric controls. Building Dimensions: 12ft. W x 16ft.L x 10ft.H (can be made more compact if requested by customer, but this size leaves ample room to perform maintenance on equipment and for a properly-sized operators compartment, if interested please request a layout drawing) Price Validity: Installation/Training: Ship Date: Warranty: Standard Terms of Sale: 30 days, subject to change thereafter without notice Please Inquire 60-90 days, subject to current manufacturing backlog 90 Days against defects in materials and workmanship 25% nonrefundable deposit to initiate order, balance due upon completion and prior to shipment or irrevocable letter of credit for full amount, payable by a major U.S. Bank

We appreciate the opportunity to furnish the above information and please dont hesitate to contact us if we can be of further assistance.
Sincerely,

John Ames Sales / Customer Service


Cc: PH; WA; MH

TubePRO 554-P Stationary 4-Function EMI Inspection System

Page 3