The following sections describe the mandatory regulations that govern the installation and operation of the LB-UA2324 and LB-UA2348 UniPhyers and of the LB-UPA111 PhyAdapter.
UniPhyer: This digital equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense. PhyAdapter: This digital equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
II
Compliance Information
try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Industry Canada Statements
UniPhyer: This digital equipment does not exceed Class A limits for radio noise emissions for digital apparatus, set out in Radio Interference Regulation of the Industry Canada. PhyAdapter: This digital equipment does not exceed Class B limits for radio noise emissions from digital apparatus, set out in Radio Interference Regulation of the Industry Canada. Operation in a residential area may cause unacceptable interference to radio and TV reception requiring the owner or operator to take whatever steps necessary to correct the interference.
Notice d'Industrie Canada
UniPhyer: Cet quipement ne dpasse pas les limites de Classe A d'mission de bruits radiolectriques pour les appareils numriques, telles que prescrites par le Rglement sur le brouillage radiolectrique tabli par l'Industrie Canada. PhyAdapter: Cet quipement nmet pas de bruits radiolectriques dpassant les limites applicables aux appareils numriques de la classe B prescrites dans le Rglement sur le brouillage radiolectrique tabli par lIndustrie Canada. L'exploitation faite en milieu rsidentiel peut entraner le brouillage des rceptions de radio et de tlvision, ce qui obligerait le propritaire ou l'oprateur prendre les dispositions ncessaires pour en liminer les causes.
EN55022 and CISPR22 statements
UniPhyer: Warning - This is a Class A product that may cause radio interference. In this case, the user may be required to take adequate measures. PhyAdapter: This is a Class B product
III
Mandatory Regulations
EU Declaration of Conformity
IV
Compliance Information
The WEEE (Waste Electrical and Electronic Equipment) legislation aims to raise the level of recycling of electrical and electronic equipment and to encourage designers to create products with recycling in mind. The UniPhyer and the PhyAdapter equipment that you bought have required the extraction and use of natural resources for their production. They may contain hazardous substances that could impact health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end-of-life equipment in a sound way.
The crossed-out wheeled bin symbol invites you not to dispose of WEEE as unsorted municipal waste and to collect such WEEE separately.
If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste administration. You can also contact us for more information on the environmental performances of our products.
Mandatory Regulations
VI
Compliance Information
Access to the interior of this unit shall be made only by a qualified technician Remove power plug from the power socket before performing any service on the unit To ensure adequate cooling of the equipment, a 2-inch unobstructed space must be provided around all sides of the unit. The Power Socket shall be installed near the equipment and shall be easily accessible To prevent the risk of shock or fire hazard, replace fuse with same type and rating
Der Zugang ins Innere des Gertes ist nur einem fachlich qualifizierten Techniker gestattet. Vorm ffnen des Gertes muss der Netzstecker yom Stromnetz getrennt werden! Um die Khlung des Gertes nicht zu beeintrchtigen, ist es notwendig, an allen Seiten des Gertes ca 5 cm Raum zu lassen Stellen Sie das Gert in der Nhe eines geerdeten Schutzkontaktsteckers so auf, dass der Stecker leicht erreichbar und zugnglich ist. Zr Vermeidung der Stromschlag-und Feuergefahr beim Auswechseln Sicherungen des gleichen Typs und der gleichen Nennleistung einsetzen
Seul un spcialiste doit avoir accs l'appareil Dbranchez l'appareil avant de l'ouvrir Afin de ne pas nuire au processus de refroidissement, il est ncessaire de laisser un espace d'environ 5 cm de chaque ct de l'appareil. Placez l'appareil prs dune prise de courant facilement accessible Afin dviter tout risque dincendie ou dlectrocution, remplacez les fusibles par des fusibles de mme type et de mme amprage.
El servicio de mantenimiento y reparacin de esta unitad slo puede ser realizado por tcnicos autorizados por el fabricante. Desconecte el cordn de alimentacin antes de cambiar los fusibles. No bloquee las ranuras de ventilacin del equipo, ya que los componentes podrian sobrecalentarse y sufrir daos Para evitar el riesgo de choque electrico o de incendio, reemplace el fusible com otro del mismo tipo y capacidad nominal. Para su propia proteccin, cercirese de que todas las conexiones elctricas de los servicios pblicos, incluyendo la puesta a tierra, las lneas telefnicas y el sistema de tuberas de agua metlicas internas, si las hubiera, estn conectadas entre s.
VII
Mandatory Regulations
VIII
Contents
Contents
1 COMPLIANCE INFORMATION ....................................................................................... II
1.1.1 1.1.2 1.1.3 1.1.4 1.1.5 1.1.6 Regulatory Compliance and Agency Approvals ....................................................................... II Compliance and Regulatory Statements..................................................................................... II Environmental Information ......................................................................................................... V Making changes or modifications ............................................................................................. VII Safety Warnings and Precautions Prevention of Access ...................................................... VII PhyAdapters - Locations .......................................................................................................... VII
PREFACE ........................................................................................................................ 1
SCOPE ............................................................................................................................................ 1 AUDIENCE ....................................................................................................................................... 1 RELATED DOCUMENTATION .............................................................................................................. 1 DOCUMENTATION CONVENTIONS ...................................................................................................... 1
3.2
3.2.1 3.2.2 3.2.2.1 3.2.2.2 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 3.2.10 3.2.11
3.3
3.3.1 3.3.2
IX
Contents
3.4
3.4.1 3.4.2
3.5 3.6
4.2
4.2.1
4.3
5.2.1
5.3 5.4
RESOLVING PROBLEMS INDICATED THROUGH ALARMS .......................................................... 45 PROCEDURES FOR TROUBLESHOOTING THE UNIPHYER AND PHYADAPTER ............................ 45
Procedure 1 - Troubleshoot UniPhyer Power-up Problems ...................................................... 46 Procedure 2 - Troubleshoot Fiber Optics Problems .................................................................. 46 Procedure 3 - Troubleshoot PhyAdapter Power Problems ....................................................... 47 Procedure 4 - Troubleshoot PhyAdapter Connection Problems ............................................... 48 Procedure 5 - Troubleshoot PhyAdapter Bridging Problems .................................................... 48
ABBREVIATIONS .......................................................................................................... 49
List of Figures
List of Figures
Figure 3-1 Mounting Bracket Orientation (Top View) ............................................................................... 5 Figure 3-2 Mounting Bracket Position for Standard Mount ....................................................................... 6 Figure 3-3 Pin Assignment of Line Interfaces .......................................................................................... 10 Figure 3-4 RJ21 Cable and Ferrite Configuration .................................................................................... 11 Figure 3-5 GBE RJ45 Pin assignment ...................................................................................................... 13 Figure 3-6 Connecting optical fiber to the trunk port ............................................................................... 13 Figure 3-7 MGMT Ethernet Port RJ-45 pin assignment ........................................................................... 14 Figure 3-8 Ethernet cross over cable pin assignment................................................................................ 14 Figure 3-9 PhyAdapter Enclosure ............................................................................................................ 15 Figure 3-10 PhyAdapter Enclosure Rear dimensions ............................................................................... 16 Figure 3-11 PhyAdapter Wall Mount Spacing ......................................................................................... 17 Figure 3-12 Data Base Configuration Concept ......................................................................................... 21
XI
List of Tables
List of Tables
Table 3-1 Table 3-2 Table 3-3 Table 3-4 Table 3-5 Table 4-1 Table 4-2 Table 4-3 Table 4-4 Table 4-5 Table 4-6 Table 4-7 Table 5-1 Table 5-2 Pre-Installation Required Tools and Materials ........................................................................... 3 Chassis Mounting actions........................................................................................................... 5 Line Length vs. power consumption measurement for Nortel i2004 IP phone ........................... 8 Sample Power budget calculation for LB-UA2348 .................................................................... 9 Line Length vs. Signaling rate ................................................................................................. 12 Maintenance Required Installation Tools and Materials .......................................................... 34 Procedures of Powering Up the UniPhyer ............................................................................... 36 Procedures of Powering Down the UniPhyer .......................................................................... 36 UniPhyer LED Indication......................................................................................................... 37 PhyAdapter LED Indication ..................................................................................................... 39 UniPhyer LED Start-up Sequence ............................................................................................ 40 PhyAdapter LED Start-up Sequence ........................................................................................ 41 Problems Indicated by LEDs.................................................................................................... 44 List of Troubleshooting Procedures ......................................................................................... 45
XII
2 Preface
Scope
This document provides an overview on the LB-UA2348 and LB-UA2324 UniPhyers and the LB-PA111 PhyAdapter. The LB-UA2324 is functionally the same as LB-UA2348 except it supports 24 ports and provides a different PoE budget than the LB-UA-2348 UniPhyer. This document contains: Procedures for installing the UniPhyer Line Bridge and PhyAdapter(s) Procedures for operating and maintaining the UniPhyer Line Bridge Procedures for troubleshooting the UniPhyer Line Bridge and PhyAdapter(s) Expansions of abbreviations used in the manual
Audience
This document is intended for system engineers or operating personnel.
Related Documentation
For information about system description, refer to the UniPhyer System Description. For information about how to manage the Line Bridge through Web GUI, refer to the UniPhyer Web Configuration Tool Guide.
Documentation Conventions
The following conventions are used in this manual to emphasize information that will be of interest to the reader.
Danger The described activity or situation might or will cause personal injury. Warning The described activity or situation might or will cause equipment damage. Caution The described activity or situation might or will cause service interruption. Note The information supplements the text or highlights important points.
2 Preface
3.1 Pre-Installation 3.2 UniPhyer System Hardware Installation 3.3 PhyAdapter Hardware Installation 3.4 Provisioning a Management IP port 3.5 Configuration Import/Export 3.6 Firmware Update
3.1 Pre-Installation
This section provides the information users have to be aware of before installing the UniPhyer. The information includes required installation tools, safety requirements, and electrostatic discharge protection.
Item Required Hand tools Wire cutter/stripper/Bix block punch tools RJ21 female to wire cables
Purpose Screw drivers for equipment removal and replacement. Prepare two wire infrastructure connections to UniPhyer and PhyAdapter connections. Female RJ21 cable termination is required, your wiring infrastructure may already have this termination or you can use a Male to Female gender bender. Screws, bolts, etc., for securing the equipment on the desired location. To Ground UniPhyer chassis if Earth Ground installation is required.
Users can access the UniPhyer via Ethernet, see Provisioning a Management IP port. o The default out-of-band MGMT IP address is 192.168.1.1. Default User is admin Default password is admin Users can then access UniPhyer via Web Configuration Tool or CLI via telnet on port 23.
Warning If you change the default username and password please ensure you record these new user and password details in a safe place. If you misplace this information and can no longer access the UniPhyer you will be required to contact customer support and incur support costs to restore the user name and password to factory default.
MOUNTING BRACKET
After the site requirements have been verified, the chassis may be installed at the specified location. When mounting the chassis, practice good safety habits. Use two or more people to secure the chassis. Relay rack mounting normally requires at least two people.
Table 3-2 Chassis Mounting actions
Step 1 2 3 4
Action Locate the chassis and obtain the appropriate chassis mounting hardware. Determine and obtain the tools required for the chassis mounting hardware. From the front of the relay rack, position the chassis in its relay rack mounting location. Using the appropriate rack mounting hardware, secure the chassis in its relay location on both left and right side of mounting bracket (see Figure 3-2).
3.2.2.3 Table Mounting the UniPhyer The UniPhyer can be placed on a table, no brackets are required. The table should be sturdy enough to hold the UniPhyers weight.
For 19 Rack
A daisy chained IP device is when the PhyAdapter is connected to an IP device, like an IP phone, which in turn is connected to one or more additional IP devices, like a PC that are powered independently from the UniPhyer. If using 6 or more PhyAdapters that are each using daisy chained IP devices, then it is required that the UniPhyer chassis be connected to EARTH ground with shielded #12 AWG conductor via chassis ground screw provided at rear of chassis near AC inlet (M4 screw).
Note If only using one IP device powered by and connected to one LB-PA111 PhyAdapter and all PhyAdapters connected to that UniPhyer are LB-PA111 model then UniPhyer does not require an additional Earth ground connection (unless specified)
3.2.5.1 Calculating your Installations Power over Ethernet Budget The power consumption of the PhyAdapter and the PhyAdapters related power consumption for the two wire loop line length, is allocated separately as part of the UniPhyer and PhyAdapter power budget, these values are detailed below as a reference. o o The LB-UA2324 UniPhyer with 24 PhyAdapters at maximum loop length will draw 136 W. The LB-UA2348 UniPhyer with 48 PhyAdapters at maximum loop length will draw 250 W.
A PoE enabled IP device has a specified maximum power consumption it does not include the power consumed on the line impendence. As the length of the two wire twisted pair increases the total impedance also increases, which means an increase to total power consumption for that port of the IP device and the line on the UniPhyer.
As an example, a Nortel i2004 IP phone had increasing power consumption at selected increasing line lengths. The Nortel i2004 has 3.2 W idle and 4.8 W maximum power dissipation rating.
Table 3-3 Line Length vs. power consumption measurement for Nortel i2004 IP phone
Idle multiplier for i2004 (in unique test deployment) 0.97 1.00 1.06 1.16 1.16
Power consumption of i2004 at max Ring 4.2 4.3 4.6 4.9 5.2
Ring multiplier for i2004 (in unique test deployment) 0.88 0.90 0.96 1.02 1.08
Note The power consumption for each IP device and wiring environment for each deployment
For your deployment, calculate each ports expected IP devices power consumption. This is done by first allocating a specified power consumption value which varies between PoE enabled IP Devices and the state those devices are in. The power consumption you use for your IP device is your choice and should be based on the IP devices specifications. The worst case is the maximum power consumption (typically maximum volume ringing state, but not always). You may want to consider budgeting some ports at maximum power consumption and others for idle state power consumption, as not all IP devices would be ringing at the same time in a your deployment. This is the decision of the UniPhyer and the parallel voice network administrator.
Warning If the power consumption of the deployed IP devices exceeds the power budget for your UniPhyer then some of the IP devices connected to that UniPhyers PhyAdapters may show abnormal behavior including power restarts and IP device reset. It is critical that proper power consideration be made when calculating the power budget
Warning Some Class 3 phones may have operational problems at longer line lengths, proper operational testing for your unique deployment is recommended.
Also be aware this is a maximum per port power budget of 10.6W which includes the line loss.
(A) (B)
a(A) = x B(B) = y
390 - x 390 - x - y
The Running total should not be below zero, otherwise unexpected operational results may occur during peak power consumption states. 3.2.5.2 Maximum System Power Consumption A simplified fully populated maximal power consumption for the UniPhyer, PhyAdapter, IP devices and line loss to use is 720 W for the LB-UA2348 and 430 W for the LB-UA2324.
Warning Ensure all legacy phones or network equipment are disconnected from the two wire
24 or 26 AWG infrastructure prior to connecting the UniPhyer Line Interfaces to prevent damage to the UniPhyer, the PhyAdapters and non UniPhyer or PhyAdapter equipment. To connect the UniPhyer through the internal office two wire 24 or 26 AWG lines, use cables with the RJ21 50-pin female connectors. When installing, just plug the end of a cable with connector into the corresponding Line interface male connector on the front panel. The following figure shows the Line port position of the system:
LINE Interface 1 port 1 24 LINE Interface 2 port 25 48
The pin assignment of Line Interface connector is illustrated below (the numbers in the connector figures below represent PIN numbers): The RJ21 can be terminated to a BIX block for easy connection of two wire infrastructure to the desired port on UniPhyer Line Interface.
18
19
20
21
22
23
24
25
Tip 1 26
Tip 2 27
Tip 3 28
Tip 4 29
Tip 5 30
Tip 6 31
Tip 7 32
Tip 8 33
~ ~ ~
Tip 18 43
Tip 19 44
Tip 20 45
Tip 21 46
Tip 22 47
Tip 23 48
Tip 24 49
X 50
18
19
20
21
22
23
24
25
Tip 25 26
Tip 26 27
Tip 27 28
Tip 28 29
Tip 29 30
Tip 30 31
Tip 31 32
Tip 32 33
~ ~ ~
Tip 42 43
Tip 43 44
Tip 44 45
Tip 45 46
Tip 46 47
Tip 47 48
Tip 48 49
X 50
3.2.6.1 Attaching the RJ21 Cable to UniPhyer To maintain EMC Class A Emissions compliance please install the RJ21 cable connector with the provided Broad Band EMI Ferrite Snap on Core as indicated in the picture below. Single loop the RJ21 cable through the Ferrite as shown in Figure 3-4.
10
3.2.6.2 Champ Lock Clip To ensure a secure connection between the RJ21 cable and the Line Interface the UniPhyer comes with a Champ Lock Clip to secure the RJ21 cable to the connector. Please ensure this is installed when cable is attached.
Warning The UniPhyer Line Interface will shut off power to any port with a short or excessive
current draw. If this occurs please resolve short problem in wiring to prevent damage to wiring infrastructure, PhyAdapter or UniPhyer.
3.2.8 Wiring Environment Warning The UniPhyer Line Interface and wiring is only for intra-office wiring, not for external to building wiring environments.
3.2.8.1 Wire Gauge and Maximum Line Length The UniPhyer System with the LB-PA111 PhyAdapter will support connections on 24 AWG and 26 AWG twisted pair wire up to 1200 feet. The 1200 feet length does not include the Ethernet cable length connected to the PhyAdapter. Ethernet cable length can be up to 300 feet from the PhyAdapter but this length as well is dependant on the distance of the PhyAdapter to the UniPhyer.
Note Wiring gauge, wiring conditions, cross connections, and loop length all have an impact on the maximum reach and connection performance as well as supported Class of IP phone at PhyAdapter
11
Typical Upstream Signalling rate (kbps) 1400 - 900 1000 600 700 400
Typical Downstream Signalling rate (kbps) 24000 - 20000 22000 - 18000 21000 - 16000
The signalling rate is different from the data throughput rate. The maximum data throughput is 80 to 85 % of the signalling bandwidth (this is due to signalling overhead of the ADSL protocol). The UniPhyer is configured for a minimum signalling connection rate when connecting to PhyAdapter to ensure enough bandwidth for voice traffic. The minimum signalling connection rates are 175 kbps for upstream and 2500 kbps for downstream.
Note Wiring gauge, wiring conditions, cross connections, and loop length all have an impact on the maximum reach and connection performance as well as supported Class of IP phone at PhyAdapter
12
T/Rx+,T/RxT/Rx+,T/RxT/Rx+,T/RxT/Rx+,T/Rx-
Mini-GBIC (SFP) Trunk Port Prepare a proper SFP module and install it into the optical trunk port. Then you can connect fiber optics cabling that uses LC connectors or SC connectors (with the use of an optional SC-to-LC adapter) to the fiber optics connector on the trunk port. Multi Mode Fiber (MMF) and Single Mode Fiber (SMF) applications are supported.
Fiber optics cable with LC duplex connector Connect the optical fiber to the SFP socket
Figure 3-6 Connecting optical fiber to the trunk port Note Please observe the proper connecting terminals for transmitting cable to TX LC-type
13
1 TX +
2 TX -
3 RX +
6 RX -
To connect the Ethernet interface to PC, the Ethernet crossover cable is required. The detailed pin assignment is shown below. If your PC Ethernet port supports Auto MDIX then no cross over cable is required.
8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8
Pin 1 2 3 6
Pin 3 6 1 2
14
Step 1 For each tip and ring twisted wire pair termination connected to the UniPhyer Line Interface there should be a corresponding RJ11 wall jack. The two wires pair termination should be on the inner pair of the RJ11 connector. Connect the telephone cable (two wire inner pair) to the jack on the PhyAdapter marked as To Phone Jack and connect the other end of the telephone cable to the RJ11 wall jack. PhyAdapters are hot swappable can be connected or removed at any time. Step 2 Connect the Ethernet cable from the PhyAdapter Jack marked To IP Phone and connect other end of the Ethernet cable to an IEEE 802.3af compliant IP Phone. Any Class 2 phone and some Class 3 phones can be used. What IEEE 802.3af compliant Class 3 phones are supported depends on the power consumption of the IP phone and two wire loop length and wire gauge; the maximum power budget for IP Phone and line power drop is 10.6W. Power is provided on the 4-5 and 7-8 pairs.
3.3.1 PhyAdapter RJ45 cable options for Class A or Class B Emission compliance
Some PhyAdapter installation environments may require Class B EMC Emission compliance. To meet EMC Class B Emissions with the PhyAdapter please use a shielded RJ45 cable between the PhyAdapter and the IP device plugged into the PhyAdapter.
15
For Class A EMC Emission compliance you can use a standard un-shielded RJ45 cable between the PhyAdapter and the IP device plugged into the PhyAdapter.
Warning When screwing into wall surfaces ensure the screw hole locations will not interfere with any electrical wiring or other hidden equipment below the wall mount surface.
The picture above is not to scale, the next picture is the actual distance between wall mount screw hole location and can be used as a template for drilling mounting holes.
16
2.518 in / 6.4 cm
Note The default GBE IP address for in-band management is 192.168.100.1. The default MGMT IP address for out-of-band management is 192.168.1.1.
Note For both CLI and Web Configuration Tool, the default login username is admin and the default password is admin
Warning If you change the default username and password please ensure you record these new user and password details in a safe place. If you misplace this information and can no longer access the UniPhyer you would require contact to customer support and incur support costs to restore the user name and password to factory default.
17
The Interface and Bridging configurations can be changed as required to customize Interface addresses or modify Bridging operation (an understanding of Ethernet and IP Bridging protocols is required). ADSL configuration can be changed but it is not recommended as the signaling connection between the UniPhyer and the PhyAdapter has been optimized for maximal System performance. (Detailed knowledge of ADSL configuration is required to change these configurations).
Note Even thought the GBE in-band IP address is 192.168.100.1, you can still bridge subnets different from this default IP address. You will not be able to access the UniPhyer Web GUI through the GBE interface unless you change the UniPhyer GBE IP address to a unique address on the subnet you are using for your parallel voice network.
18
yet been saved. Change your IP address to a new address on the same new subnet domain of the configured UniPhyer network port being used and continue procedure to ensure the IP addresses and remaining IP information changes are stored permanently in flash memory. e. On the menu tree, click on System ---> IP Routes. The IP Routes page is displayed. f. Type in new IP address of the system default gateway and then click Set button or add other routes. Suppose the administrator wants to set MGMT IP address as 172.16.10.81 and GBE IP address as 192.168.100.5:
19
Finally, remember to save new settings to flash memory: On the menu tree, click on Maintenance ---> Database. The Database Configuration page is displayed. Click on the DB Config Select drop-down list and select (D)Save Running Config to Flash.
Select write to Partition 1 (or Partition 2 if desired). Then click on Write_Running button. Wait for memory write success message.
20
21
Suppose that TFTP Server IP address is 172.16.100.241 and configuration file name is config1: Via Web GUI: On the menu tree, click on Maintenance --- > Database. The Database Configuration page is displayed. Select the database configuration action you want to perform.
(A) Import File (Write Download Config To Flash): Type in the TFTP Server IP address and the name of the file you want to download and select the partition to write too (active partition is displayed System---> System Info). Then click on Get File button.
22
23
(B) Import File (Load Remote Config to Running Config) Type in the TFTP Server IP address and the name of the file you want to download. Then click on Get File button.
Example when import failed because failed to retrieve remote configuration file:
24
(C) Export File (Put Running Config to Remote TFTP Server) Type in the TFTP Server IP address and the name of the file you want to export. Then click on Put File button.
25
(D) Save Running Config to Flash (System Config) Click on the drop-down list and select partition, and then click on Write_Running button to write running configuration to Flash.
26
(E) Reload Flash to Running Config Click on the drop-down list and select partition, and then click on LOAD_FLASH button to load configuration from Flash to Running Config.
27
(F) Restore Factory Default Except out-band IP address and user accounts, all other configuration will be restored to factory default. Click on Factory_Default button to restore factory default configuration.
After loading default configuration to Flash successfully, you must click on RESTART button to restart the system so that the configuration can take effect.
Note Restoring the Factory default does not change the MGMT IP address or the user name/passwords.
28
(G) Flash Boot Point Configuration Select Click on the Boot Config drop-down list and select the partition (Partition1 or Partition2) as the boot point. Click on Apply button and then restart the system. The system will restart and load the configuration in the partition you select into the running configuration. Multiple configurations could be used for different UniPhyer bridging or network configuration environments
29
Label Firmware Update Remote FTP Server IP Server User Name Server Password File Name Firmware Update Status Firmware Partition Select
Description Once you have typed in the parameter values, click on this button to start firmware update. Type in the IP address of the FTP server. Type in the ftp user name. Type in the ftp password. Type in the firmware filename. This field shows current status of firmware update process. Select firmware memory partition (Partition 1 or 2). If you change to the other partition (not current partition), the system will restart immediately.
30
Partition Information
This section displays the partition information including firmware version, updating date, and status (active or not). Note that active partition means the partition for next power-up, not current partition in use. You can refer to Current Version to know which partition is the current partition in use. When you update the firmware, new firmware will be written to the partition that is not currently in use.
FTP Get in progress: The following message is displayed during getting file from FTP server.
Firmware Write in progress: The Flash Write process may take a few minutes; you must not turn off or reset the system during the process. Your FTP server may show disconnection and reconnection events during this initial Flash erase and subsequent block download of sectors to the UniPhyer, this is due to the mechanism of the upgrade and the FTP server operation. The Upgrade process should not exceed 10 minutes.
Firmware Write successfully: When the Flash Write process has completed successfully, the Firmware Update Status shows Firmware has upgraded already. You can now restart the system.
31
32
4.1 Maintenance requirement 4.2 Powering the UniPhyer Up or Down 4.3 Controls and LED Indication
33
Purpose Protect the system from electrostatic discharge damage Screwdrivers for equipment removal and replacement Prepare wires for electrical connections in wire closet and demark areas with punch blocks.
Hand tools
VF transmission and signaling Testing faulty two wire infrastructure test sets
34
35
Step 1 2 3 4 5 6
Action If available, put on the antistatic wrist strap and connect it to a grounding point Ensure that the UniPhyer is securely installed. Ensure all legacy digital and analog phones and PBX equipment are disconnected from two wire infrastructure Ensure the PhyAdapters are plugged into the desired RJ11 wall jacks. Slide the power switch at rear of UniPhyer to 1 The UniPhyer will do a series of self tests at Power up (shown by LED changes) after three minutes the UniPhyer should be operational. If the LEDs show some problem, refer to section 5.2 for information on how to resolve problems indicated through LEDs. You may add or remove PhyAdapters at any time when UniPhyer is powered up. The PhyAdapters are hot swappable.
Table 4-3
Step
Action Caution: Powering down the UniPhyer will power down PhyAdapters and IP phones connected to PhyAdapters
1 2
If available, Put on the antistatic wrist strap and connect it to a grounding point. Slide the power switch on the rear of chassis to 0.
36
LED SYS
Indication / Condition At Power on phase Self-test fail Normal Operation At power on phase Major alarm set Major and Minor alarm set Minor alarm set Normal operation SFP interface activated RJ-45 interface activated
ALM
GBE1/GBE2
Green Off
Note: Yellow LED color may also appear Orange in some cases.
37
Port PhyAdapter Green Connection Status Green fast Flash (ADSL status) Green slow Flash
Port is activated, and linked Port is attempting to Link with PhyAdapter Port is activated but not linked (maybe no PhyAdapter on the line or connectivity issue) Disabled 100 / 1000 Mbps 10 Mbps Active Inactive Data Tx/Rx 100 Mbps 10 Mbps Active Inactive Data Tx/Rx Description
Off GBE1- Speed* GBE2- Speed* (LED B on RJ-45) GBE1-Link/Act* GBE2-Link/Act* (LED A on RJ-45) MGMT- Speed Green Off Green - Flash Orange Orange Off
(LED B on RJ-45) Off MGMT-Link/Act Green (LED A on RJ-45) Off Green - Flash Interface GBE1 SFP1 GBE2 SFP2 MGMT
Gigabit Ethernet electrical trunk port 1 Gigabit Ethernet optical trunk port 1 Gigabit Ethernet electrical trunk port 2 Gigabit Ethernet optical trunk port 2 Ethernet Port connected to LAN for providing system out-band EMS/Telnet control interface, such as system monitor, control or software upgrade. RJ21 Line interface to the PhyAdapters, two 24 port connectors
Line Interfaces
*Note that the LEDs on GBE RJ-45 jack are for indicating the uplink status whether the data is transmitted through optical interfaces or electrical interfaces.
38
Color
Indication / Condition No power present or PhyAdapter is not connected to UniPhyer (possible problem with Adapter signaling operation) Power up or DSL connecting state Normal Operation PhyAdapter is connected to UniPhyer (DSL link is active) Inactive - No Ethernet connectivity detected Active - Ethernet link detected Data TX/RX
Green - flashing Green - solid Network (right most LED on RJ45 connector) OFF Green solid Green flashing
39
Description
LED state
Duration
OFF Initial power up Power up self test #1 Power up self test #2 Main board initialization DSL board - Lower 24 port initialization Lower 24 ports individually activated.
No LEDs GBE2, GBE1, ALM ON, ALM - Yellow SYS/ALM alternate on - RED SYS - YELLOW ALM YELLOW SYS - GREEN ALM YELLOW SYS GREEN Port LEDS 1 thru 23 start turning active
35 sec
140 sec
40 sec
180 sec
ALM YELLOW SYS GREEN Port LEDS 1 thru 23 active Port LEDS 24 thru 48 start turning active
35 sec
215 sec
215 sec
40
Description
LED state
Duration
OFF
No LEDs
Plug in RJ11 cable Network LED is GREEN 2 sec Initial power up self tests Connection LED is OFF Adapter initialization 1 Network LED is OFF Connection LED is OFF 2 sec
4 sec
Adapter initialization 2 Network LED is GREEN 3 sec ENET PHY is (if network device operational rest of board plugged into RJ45) initializing Connection LED is OFF Adapter passed self test - Network LED is GREEN attempting to do DSL (if Network device connection plugged into RJ45) Connection LED is Flashing 58 sec
7 sec
65
Network LED is GREEN/Flashing (if network device is plugged into RJ45) Connection LED is SOLID
5 sec
70 sec
Network LED is Flashing (if network device is plugged into RJ45 and traffic) Connection LED is SOLID
70
Network traffic will not cross the link between the PhyAdapter and the UniPhyer until the Connection Link is solid.
41
Note
When the UniPhyer first powers up there is a 3 and 1/2 minutes start up time before the UniPhyer attempts to make a connection to the PhyAdapter. Once the UniPhyer is powered up it will always be looking to connect to a PhyAdapter when it is plugged in (as long as the port is enabled on the UniPhyer.) During this time if the PhyAdapter is plugged into the UniPhyer port only the Network LED will show activity.
42
5.1 Introduction to Troubleshooting 5.2 Resolving Problems Indicated Through LEDs 5.3 Resolving Problems Indicated Through Alarms 5.4 Procedures for Troubleshooting the UniPhyer and PhyAdapter
43
SYS
There is a power up problem Troubleshoot the UniPhyer for with the system. power up problems; see section 5.4. Self-test failed. There is a functional problem with the system. Major alarm set Replace the UniPhyer.
ALM
Red
See section 5.3. Note: Default Software Alarm mask configuration will have Red alarm. Consider reconfiguring Alarm masks to clear this event
Red-Flash Yellow GBE1/GBE2 (If SFP interface is activated) Not lit even though UniPhyer is powered up
See section 5.3. See section 5.3. Troubleshoot the UniPhyer for fiber optics problems; see section 5.4.
44
45
46
47
48
6 Abbreviations
ADSL ADSLx ANSI ATM CLI EMS EN EU DSL EMC EMI ETSI FCC IEC Mbps MDF LED PoE POTS PSTN PVC SNMP
asymmetrical digital subscriber line ADSL/ADSL2/ADSL2+ American National Standards Institute asynchronous transfer mode command line interface element management system European Norms European Union digital subscriber line electromagnetic compatibility electromagnetic immunity European Telecommunications Standards Institute Federal Communications Commission International Electrotechnical Commission megabit per second main distribution frame light emitting diode Power over Ethernet plain old telephone service public switched telephone network permanent virtual circuit simple network management protocol