3C + E
COPPER
APPLICATION
For mains, submains and subcircuits unenclosed, enclosed in
conduit, buried direct or in underground ducts for buildings and
industrial plants where not subject to mechanical damage.
STANDARD
VOLTAGE
CONDUCTOR
INSULATION
SHEATH
PVC, 5V-90
Orange
90 C
Item
Number
Conductor
kg/km
Minimum
Installed
Bending
Radius
mm
18206131
1.5
7/0.50
10.9
11.6
180
70
100m
200m
500m
18550131
2.5
7/0.67
12.1
12.9
240
75
18918131
7/0.85
13.8
14.6
330
90
19038131
7/1.04
15.0
15.8
375
95
19127131
10
7/1.35
17.1
17.9
540
105
19220131
16
7/1.70
19.3
20.3
770
120
19277131
25
7/2.14
22.9
24.0
1095
145
61820131
35*
7 strands
24.4
25.5
1425
155
62405131
50*
19 strands
27.8
29.0
1900
175
62710131
70*
19 strands
32.2
33.5
2675
200
62800131
95*
19 strands
36.4
37.8
3575
225
62830131
120*
19 strands
39.9
41.3
4435
250
62836131
150*
19 strands
44.3
45.8
5490
275
62837131
185*
37 strands
49.4
51.1
6935
305
62882131
240*
37 strands
56.3
58.1
9185
350
mm
(No./mm)
Minimum
mm
Maximum
mm
4.1.3.3.1.1.5
Overall Diameter
Approx.
Mass
Standard Packing
CONDUCTOR
Nominal Area
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
Buried
In Ducts
Maximum
DC
Resistance
@20C
ELECTRICAL CHARACTERISTICS
Maximum
Equivalent
3 Phase
AC
Star
Voltage Drop
Resistance
Reactance
@90C
@90C
A
15
A
13
A
19
/km
13.6
/km
17.3
/km
0.111
mV/Am (b)
30.0
22
29
37
51
68
91
110
135
170
215
245
280
325
385
18
24
31
42
56
79
92
110
140
165
195
225
260
305
26
34
43
57
74
96
115
140
175
210
240
270
310
370
7.41
4.61
3.08
1.83
1.15
0.73
0.52
0.39
0.27
0.20
0.15
0.12
0.10
0.08
9.45
5.88
3.93
2.33
1.47
0.927
0.669
0.494
0.343
0.248
0.197
0.160
0.129
0.100
0.102
0.102
0.097
0.091
0.086
0.085
0.083
0.080
0.077
0.077
0.074
0.074
0.074
0.074
16.4
10.2
6.80
4.05
2.55
1.61
1.17
0.87
0.61
0.45
0.37
0.31
0.26
0.22
(a) Based on 40C ambient air temperature and where applicable, burial depth of 0.5m, soil temperature of 25C and soil resistivity
of 1.2C.m/W.
(b) For single phase voltage drop, multiply by 1.155.
The above information is from the following sources:
For installation with thermal insulation refer to AS/NZS 3008 for de-rating factors.
Do not put in direct contact with polystyrene, polyurethane or similar thermal insulation materials.
ACTIVE / CONDUCTOR
Nominal
Nominal
Minimum
Area
Diameter
Insulation
Thickness
Nominal
Area
EARTH CONDUCTOR
Number &
Minimum
Diameter of
Insulation
Wires
Thickness
mm2
mm
mm
mm2
No/mm
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
1.5
2.0
2.5
3.1
3.9
4.9
6.4
7.0
8.1
9.8
11.4
12.9
14.3
16.0
18.4
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
1.5
2.5
2.5
2.5
4.0
6.0
6.0
10
16
25
25
35
50
70
95
7/0.50
7/0.67
7/0.67
7/0.67
7/0.85
7/1.04
7/1.04
7/1.35
7/1.70
7/2.14
7/2.14
7 strands
19 strands
19 strands
19 strands
0.6
0.7
0.7
0.7
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
4.1.3.3.1.1.5
Diagrams of cables are illustrative only and are not necessarily to scale.
General Cable New Zealand Limited and General Cable Australia Pty Ltd reserves the
right to change or vary the construction of any of their products without notice. Whilst
every care has been taken in the preparation of this publication, General Cable New
Zealand Limited and General Cable Australia Pty Ltd accept no liability of any kind and
are not responsible for the results of any actions taken on the basis of this information or
resulting from errors or omissions. This technical data sheet is intended as a guide only;
any person using it must make reference to the appropriate local standards or authorities.
All rights reserved. No part of this work covered by copyright may be reproduced or
copied in any form or by any means without the written permission of General Cable
New Zealand Limited. or General Cable Australia Pty Ltd.
2001.