Flow line to be 4" to 6" [100 to 150] below normal ditch, returning to normal

NOTES A
" [6] 2-3" [695] 2" [ 50] " [6] 6" [150] 5" [ 25] 1

B
" [6] 2-3" [695] " [6]

10 to 15 [3 to 5 m] each side of basin.

Grate

Construction joint
[ 25] 1 "

If necessary, bicycle safe grates shall be specifed in the plans. Bicycle safe grates shall be Neenah No. R-4859-C or East Jordan No. 5110 Type M3 or approved equals. As of January 1, 2003, the following text shall be cast into the top of the grate: 8" [ 200] "DUMP NO WASTE" and "DRAINS TO WATERWAY" Reinforcing Steel Text shall be printed in bold, capital letters with a minimum height of ". "WATERWAY" may be substituted with "STREAM","RIVER","LAKE", etc. Actual placement and logo may vary per manufac-

32" [ 800] mi . n

6"

2-0" [600]

[ 50] 1

C
Optional 2" [50] precast joint 2" [50]

Side inlet Flow line

2-0" [600]

C A
Permissible Const. Joint

48" [1200] min.

turer.
REVISIONS

WALLS: Shall be 8" [200] thick when reinforced, 2-3" [695] 2" [50] 2" [50] "[ 695] as shown. Brick walls, when used in place of Brick walls, when used in place of reinforced concrete, shall have a nominal thickness of 12" [300]. Precast walls shall have a minimum thickness of 6" [150] and be reinforced sufficiently to permit shipping and handling without damage and shall be at least equivalent to reinforced cast-in-place construction. Precast tops shall meet cast-in-place tops for dimensions and reinforcement.

7-20-01 7-19-02 7-15-05

#6 [#19M] bars Mul pl of Step Spaci g ti e n

#6 [#19M] bars

e t a r G

CB No 2-5 = 5-0" [1500] CB No. 2-6 = 6-0" [1800]

8" [200]

8" [200]

CB No 2-5 = 5-0" [1500] CB No. 2-6 = 6-0" [1800]

8" [200]

ALL METRI DI C MENSI ONS

I MI N LLI METERS UNLESS

( I BRACKETS [ ) ARE N ]

8" [ 200]

8" [200] Depth var abl i e

1 6" [ 400] max.

1 2" [ 300] mi . n

8" [200]

8" [200]

CONCRETE CONCRETE: Cast-in-place concrete is to be Class C. All precast concrete shall meet the requirements of CMS 706.13 and be marked with the catch basin number. REINFORCEMENT: Reinforcing in the top is to be #6 [#19M] bars spaced 6" [150] center to center and #6 [#19M] tie bars spaced as shown. Main bars to clear bottom of slab by 1" [32]. Side wall to be reinforced with #6 [#19M] bars horizontal in each side, 6 [1800] long for CB No. 2-5 and 7 [2100] long for CB 2-6, spaced at 1 [300] center to center and #6 [#19M] bars in each corner length equals depth plus 1 [300]. If PRECAST BASE: a precast base is used, it shall be set deep enough so that the top can be placed on the base to provide the grate elevation specified in the plans. Layers of brick shall not be used to adjust the top elevation. LOCATION AND ELEVATION: When given on the plans the location and the elevation are at the top center of the grate. When side openings are provided, the elevation shall be at the flow line

f cheek

PLAN
All grate edges to be rounded " [6] radii

STRUC TURA L CA TCH BA SI S N N o s 2-5 & 2-6

Step (Typ.)
03- OCT- 2008 9: 45AM

joint

I \ pr Const ucton Dr : \ r i awi ngs\ SCD\ Hy aul dr i cs\ CB\ cb1 3_ 07- 1 5- 05_ V8. dgn

1 [ " 25] ( Typ. )

CB No. 2-5=5-0" [1500] 1" [25] (Typ.) Ver cal steel or ti bar ti e s acr oss thi j n s oi t CB No. 2- 5 0" [ 500] 5= 1 CB No. 2- 6 0" [ 800] 6= 1 CB No. 2-6=6-0" [1800]

8" [ 200]

When possible, top to be higher than top of outlet pipe

Optional precast

of the side inlet. MINIMUM DEPTH: The minimum depth of CB No. 2-5 and CB No. 2-6 shall be the outside diameter (O.D.) of the outlet pipe plus 7" [175]. Any pipe openings greater than 4" [100] OPENINGS: from the outside of the pipe to the structure require the Engineers approval. Fill all voids per CMS 604. SIDE INLETS: Inlets shall be provided on both sides of the No. 2-5 and 2-6 catch basin in sags and on upstream side only where the ditch has a continuous down grade past the catch basin. Catch basins with side inlets shall not be used within the Clear Zone. All materials and labor, including excaPAYMENT: vation and backfilling, shall be paid for under Item 604 - Catch Basin, No. 2-5 or Item 604 Catch Basin, No. 2-6.

A
Bottom slab may be precast separately, and the outlet pipe placed on top of it with the bottom shaped to drain

F.L.

8" [ 200] mi . n

3" [ 75]

SCD NUMBER

SECTION A-A

SECTION B-B

SECTION C-C
CATCH BASIN 2-5 OUTLET PIPE SIZE 48" to 54" [1200 to 1350] 60" to 72" [1500 to 1800]

CATCH BASINS No. 2-5 & No. 2-6

2-6

C B -1. 3 1

Permissible const. joint

Permissible const. joint

8" [200]

8" [200]

8" [ 200]

Step

STANDARD HYDRAULI CONSTRUCTI C ON DRAWI NG

EN G I EERI G N N

O FFI E C

OF

OTHERWI SE NOTED.

STEPS: Steps shall be provided where the depth exceeds 6 [1.8 m] and shall meet the requirements of SCD MH-1.1.

J Stai s . n

ROADWAY HYDRAULI C ENGI NEER

2 3 -

STATE HYDRAULI ENGI C NEER

SCD CB-1.1. SCD CB-1.1. See details on Minimum weight GRATE: [mass] of grate: 120 lbs. [54 kg], or meets the requirements of CMS 711.14. Grate openings and dimensions shall not differ from those shown unless otherwise shown in the plans.

STATE OF OHI DEPARTMENT OF TRANSPORTATI O ON