Anotec® Product Information

Odour Management

Anotec® 0307
Odour Control – Vapour Phase
Features
• Removal Efficiency for Odour mitigation chemical for industrial, fugitive and related
Odour >90% odorous emissions.
• Safe Non-toxic and
immediate reduction
Applications:
• To significantly reduce and / or eliminate malodours associated with
landfill, site remediation and waste management facilities using
engineered atomising devices.

Typical Properties:
*Specification Writers: Please contact your local Anotec sales office before
writing specifications for this product

Composition Test Unit Result

• Proprietary blend, safe, Appearance Clear / White liquid


synergised surfactants, Vapour Pressure (mm of Hg@25 C) 0
Similar to water
nature identical odour 0
control agents Flash Point, closed cup C >150
Solubility in water % 100

DESCRIPTION

The chemical constituents of Anotec® 0307 are to exert a significant effect on the rate of
highly active organic compounds that include but degradation. Run-off can be disposed of via normal
are not limited to sugar derivatives and peptides. wastewater channels.
Anotec’s unique blend of compounds forms
complexes that effectively absorb and treat The proprietary additives for binding, enhancing
offending odour molecules. Further, the Anotec® biodegradation and odour profiling – each of which
0307 blend, when applied, reduces the surface is >2% - are all food grade quality.
tension in the liquid phase and assists in the The active ingredients in this product have boiling
blocking or inhibition of volatisation of malodours. points in >1500C. Anotec® 0307 is fully miscible in
water and the product does not have a measurable
The effectiveness of Anotec® 0307 Odour Control flash point.
formulations stems from the unique chemistry of Application via a misting or fogging system ensures
synergised surfactants ad odour profiling direct contact between the Anotec odour control
technology, enabling efficient and immediate formulation and the malodorous emission. Upon
reduction in chemical odour concentrations when direct contact, odour analysis shows a significant
compared to conventional odour abatement reduction in chemical odour concentrations for each
technologies. component identified in any malodorous mix. 1

The non-ionic surfactants in the product are readily


biodegradable in standard BOD tests and CO2
evolution procedures. Neither slight branching nor
increments in the length of the carbon chain appear
1
GC/MS & Olfactometry – Laboratory & Field
Anotec® Product Information
Odour Management

PERFORMANCE CHARACTERISTICS

Performance Characteristics of Anotec® 0307 odour control formula compared with Conventional Odour
Abatement Methods (Masking Agent)

Anotec® 0307 Masking Agent


(1:300 dilution) (1:300 dilution)
Odour Profiling Technology Perfume
Removal Efficiency Removal Efficiency
VOCs and Other Odours (Putrescibles Waste) (%) (%)

Chemical Components (ppm)


1,1,1 trichloroethane 5.62………………………….. 95 0.5
2-methyl pentane 3.5……………………………….. 98.25 8.7
2-methyl butane 0.9………………………………… 95.71 0.2

Chemical Components (ppm)


Acetone 12.0………………………………………… 99.3 Increase
Benzene 10.8………………………………………... 99.95 Increase
C7-C11 alkanes 79.36……………………………… 89.90 9.6

Chemical Components (ppm)


C3-alkylbenzenes 9.6………………………………. 99.64 Increase
Carbon disulfide 2.3………………………………… 98.13 0.9
Carbonyl sulphide 8.2………………………………. 99.96 0.7

Chemical Components (ppm)


(Olfactometry reported = 300 ODU) ODU = 4 ODU = 515
Dimethyl sulphide 15.3……………………………... 99.14 0.31
Hydrogen sulphide 58.9……………………………. 99.98 3.20
Methyl mercaptan 21.32……………………………. 99.92 2.93
Methyl amine 16.8…………………………………... 98.81 0.20

Simulated Wind Tunnel Tests H2O Only


(Permeation device)
Raw / Untreated Odour: ODU = 18, 227 ODU =4092 ODU = 1063 ODU = 26, 309

HOW TO USE

Industrial: (Liquid Phase) Formulations. prior to use. This product is supplied as a


Hyperconcentrate formulation.
Anotec® 0307 odour profiling formulations may be
used as an additive ingredient for highly odorous Available in 200-L, 25-L
products such as pesticides, slurries, lagoons, paint 5-L & 1-L containers
etc. The product is identified as Anotec PRO5L and Other volumes available
is stable upon application that does not affect the upon request.
chemistry of the product to be treated. If added to
wet scrubber liquor, an anti-foaming agent may be
required and is available via Anotec’s network of
distributors.

Anotec PRO5L, when used as an odour control


additive to finished products must not be diluted
Anotec® Product Information
Odour Management

LIMITATIONS
Industrial & Waste Management
(Vapour Phase) Formulations Anotec products are neither tested nor represented
as suitable for medical or pharmacological use.
Anotec® 0307 odour control formulations are
diluted with clean water prior to use. Once the PRODUCT EVALUATION & ASSESSMENT
chemistry of the emission has been determined, the INFORMATION
appropriate Anotec® 0307 formulation will be
supplied. As a guideline, Dilution rates vary Evaluation of Anotec odour control formulations
between 1:40 – 1:1000. Example, small sewage have been carried out by numerous government
installations with low-medium odour levels will dilute and private laboratories and organisations. These
Anotec® 0307 1:40 prior to use. include but are not limited to ANSTO,
Environmental Science Program (AUS), Odor
Anotec® 0307 products can be applied via high Science Engineering (USA), Korea Heavy Industry
pressure or air atomisation devices, via portable Group (ROK), Stephenson & Associates (AUS),
(hand-held and larger) misting systems or custom CH2MHill (AUS), Dow Corning (NZ for PRO5L),
built application equipment depending on the University of New South Wales (AUS).
industry type and area to be treated. Removal Efficiency (RE%) using Anotec
formulations to challenge malodours have
APPLICATION consistently been reported to be >80%.

Achieving the correct droplet size is fundamental in LIMITED WARRANTY INFORMATION – PLEASE
ensuring the efficacy of Anotec odour control READ CAREFULLY
formulations. Anotec product consumption rates
heavily depend on application device and duration The information contained herein is offered in good
of atomisation. faith and is believed to be accurate. However, due
to varying conditions and methodologies engaged
USABLE LIFE & STORAGE by clients when using our products that are beyond
our control, we strongly advise against using this
When stored between 200C ad 400C Anotec® 0307 information in conjunction with any other product
odour control products have a shelf life of two years and forbid the use of any analytical or sensory
from the date of manufacture. Once opened, the assessments to be used as support for
product will need to be consumed within 6 months implementation at any given site unless a
to retain efficacy. comparative study is conducted onsite.

PACKAGING Anotec’s sole warranty is that the product will meet


the Anotec sales specification in effect at the time of
All Anotec odour control formulations are available despatch from their warehouse or delivery dock.
from 500-ml bottles to 1000-L tanks. Your exclusive remedy for breach of such warranty
is limited to refund of purchase price or replacement
of any product proven to be other than as
warranted.
Anotec® Product Information
Odour Management

APPLICATION EXAMPLES: PHOTOGRAPHS


Indicative only – models and systems may vary

High Pressure systems with Hydraulic nozzle


configurations (fixed systems)

Drum mounted units (FogMaster USA)

Air atomisation nozzle application (fixed system)

Portable odour control units used during QEII visit


60-L, 200-L and 100-L (not shown) self contained to Sydney. 400, 000 Litres of raw sewage was
portable units for use outdoors (waste pumped out whilst Anotec was sprayed to eliminate
management, landfill and site remediation). malodours from affecting the surrounding
community.
Anotec® Product Information
Odour Management

Photograph – Anotec Pty Ltd 2006 Photograph – Anotec Pty Ltd 2006
Cluster nozzles (high pressure system) Anotec® 0307 product onsite storage

Photograph – Anotec Pty Ltd 2006 Photograph – Kaplan Ticaret 2006


1000-L Control system to service fans or fixed Nozzle spraying into pond
nozzle systems

Photograph – Anotec Pty Ltd 2006 Photograph – Kaplan Ticaret 2006


Perimeter spraying (Fixed & timed system) Truck mounted system
Anotec® Product Information
Odour Management

CONSUMPTION RATES (Guideline only)

Calculations herein are based on worst case


scenario and will vary in accordance to selected
application device(s) and / or application rates
(timers)

Worst case scenario = 24 hr continual application

Guideline for 1% solution = 1Litre /1Metre /1Hour

2
Calculation for area approximating 300m (there
may be a need to simply apply product to pre-
Photograph – Kaplan Ticaret 2006 determined areas hence the omission to calculate
Truck mounted system front view encompassing the nominated and specified
measurement of 900 x 70 x 35

1. High pressure system (fixed, perimeter


spraying) networked system =

1000-L Anotec per week

2. Air Atomisation System (fixed, perimeter


spraying) = 500-L Anotec per week

500-L Anotec per week

3. Rotary Atomisers (approximately 10 units


through area) =

250-L Anotec per week


Photograph – Kaplan Ticaret 2006
Side wall system – adjustable The calculation herein should be re-worked to fit in
with your specific requirements.

The landfill operation mentioned may require that


you dilute the Anotec product up to 1:800.