3.3. Hydraulic motor 2012 3.3. Hydraulic motors 3.3.1.

Introduction A fluid power motor is a device that converts fluid power energy to rotary motion and force. The function of a motor is opposite that of a pump. However, the design and operation of fluid power motors are very similar to pumps. Motors have many uses in fluid power systems. In hydraulic power drives, pumps and motors are combined with suitable lines and valves to form hydraulic transmissions. The pump, commonly referred to as the A-end, is driven by some outside source, such as an electric motor.

The pump delivers fluid to the motor. The motor, referred to as the B-end, is actuated by this flow, and through mechanical linkage conveys rotary motion and force to the work. This type of power drive is used to operate (train and elevate) many of the Navys guns and rocket launchers. Hydraulic motors are commonly used to operate the wing flaps, radomes, and radar equipment in aircraft. Air motors are used to drive pneumatic tools. Air motors are also used in missiles to convert the kinetic energy of compressed gas into electrical power, or to drive the pump of a hydraulic system.

Fluid motors may be either fixed or variable displacement. Fixed-displacement motors provide constant torque and variable speed. The speed is varied by controlling the amount of input flow. Variable-displacement motors are constructed so that the working relationship of the internal parts can be varied to change displacement. The majority of the motors used in fluid power systems are the fixed-displacement type. Although most fluid power motors are capable of providing rotary motion in either direction, some applications require rotation in only one direction. In these applications, one port of the motor is connected to the system pressure line and the other port to the return line or exhausted to the atmosphere. The flow of fluid to the motor is controlled by a flow control valve, a two-way directional control valve, or by starting and stopping the power supply. The speed of the motor may be controlled by varying the rate of fluid flow to it.

In most fluid power systems, the motor is required to provide actuation power in either direction. In these applications the ports are referred to as working ports, alternating as inlet and outlet
Hydraulic and pneumatic control lecture notes by Siraj K. Page 1

3.3. Hydraulic motor 2012 ports. The flow to the motor is usually Fluid motors are usually classified according to the type of internal element, which is directly actuated by the flow.

Figure 3.3.1. Actuators classifications

3.3.2. Limited rotation hydraulic motors Limited rotation actuators, called torque motors, have a wide variety of applications where a limited specified degree of rotation at the output shaft is required. Rotation is usually limited to 720. They are used extensively in industry for actuating clamping devices, material handling, rotating cams for braking mechanisms, tumbling and dumping, positioning and turning, and many other situations where an economical application of fluid power for limited rotation is desirable. (Fig. 3.3.2) Vane-type limited actuators apply fluid force to the cross section area of single or multiple vanes. Rack and pinion type actuators apply fluid force to the cylindrical chambers which move the rack to drive the pinion gear.

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 2

3.3. Hydraulic motor 2012

Figure 3.3.2 (a) Rack and pinion limited rotation actuator (courtesy of Flo-Tork, Inc. ); (b) Vane type limited rotation actuator (courtesy of Bird-Johnson ); (c) Typical applications of limited rotation actuators (courtesy of Bird-Johnson).

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 3

3.3. Hydraulic motor 2012 Analysis of torque capacity The following nomenclature and analysis are applicable to a limited rotation hydraulic motor containing a single rotating vane:

RR = Outer radius of rotor (in, mm)


RV = Outer radius of vane (in, mm)
L = Width of vane (in, mm) p = Hydraulic pressure (psi, Pa) F = Hydraulic force acting on vane (lb, N) A = Surface area of vane in contact with oil (in2, m2) T = Torque capacity (in. lb, N.m)

The force on the vane equals the pressure times the vane surface area: F = pA = p(RV R R )L The torque equals the vane force times the mean radius of the vane:

T = p(RV RR )L

(RV

+ RR ) 2

On arrangement we have
T= pL 2 2 RV R R 2

3.3.1

A second equation for torque can be developed by noting the following relationship for volumetric displacement VD:
2 2 T = RV R R L

3.3.2

Combining equations (3.3.1) and (3.3.2) yields

T=

pVD 2

3.3.3

3.3.2. Types of hydraulic motors Continuous rotation actuators, called hydraulic motors, provide sustained rotation in either direction. Some hydraulic motors are also convertible to serve as hydraulic pumps if a mechanical drive is applied to the output shaft, but this is not usually recommended without special provision because of port timing and other internal part arrangements. Vane motors, for
Hydraulic and pneumatic control lecture notes by Siraj K. Page 4

3.3. Hydraulic motor 2012 example, have spring loaded vanes, whereas vane pumps usually do not. This is not the case with axial piston motors, however , which are widely advertised as combination pump-motors.

Hydraulic motors differ from pumps in other respects. Because the case is pressurized from an outside source, case drains are provided to protect shaft seals (Fig .3.3.3). These may be piped directly to the low pressure reservoir, or through a crossover check valve arrangement to the exhaust port of the motor. External drain lines or crossover check valve arrangements are needed only for series circuits or meter out circuits. This is necessary during reversing, braking, and other operating conditions which would otherwise subject the case drain to system pressure. Maximum pressure at the case drain is usually 100-250 psi. Port timing is an additional factor that may be different between pumps and motors.

Figure 3.3.3. Hydraulic case drain arrangements

Hydraulic motors are available as fixed or variable displacement unit s so that speed variation with rotation in either direction is possible.

Gear motors External gear positive displacement motors operate in the reverse manner of their pump counterparts (Fig. 3.3.4). They are available in sizes to 20 in3 per revolution. Fluid supplied to the inlet port circulates around the out side of the gear teeth driving both gears, although only one gear is connected to the motor output shaft. The gear teeth seal where they mesh and between their ends and the motor housing. Fluid is trapped in cavities formed by the gear teeth and the motor housing and transported around the out side diameter of the gears to the low pressure port side of the motor.
Hydraulic and pneumatic control lecture notes by Siraj K. Page 5

3.3. Hydraulic motor 2012

Industrial gear motors are the least expensive to manufacture, have overall efficiencies to 90%, and operate in the speed range of 1000 to 2500 rpm. Recent developments in gear tooth materials and technology have extended the speed range of gear motors in excess of 20,000 rpm for motor size s in the 0.063-0.093 in3 per revolution displacement range. Their small size, high speed, and high power (4-5.5 hp) make these motors ideal for spindle drives in the machine tool industry.

Figure 3.3.4. External gear positive displacement motor

Vane motors Vane motors operate similarly to vane pumps with the exception that unlike their pump counterpart s, spring loading is used to insure positive contact between the vanes and the
Hydraulic and pneumatic control lecture notes by Siraj K. Page 6

3.3. Hydraulic motor 2012 eccentric cam ring (Fig 3.3.5). Seals, high speed bearings, and case drains also are given special attention.

Vane motor showing spring loaded vanes

Figure 3.3.5. Vane-type motor.

Fluid entering the motor under high pressure acts against the rectangular surfaces of the vanes while the chamber volume increases, and then is exhausted as it decreases (Fig. 3.3.6). Balanced
Hydraulic and pneumatic control lecture notes by Siraj K. Page 7

3.3. Hydraulic motor 2012 vane motors admit fluid from two ports located 180 apart to reduce side thrusts on the supporting shaft and bearings, and discharge the fluid 90 later through two similarly located discharge ports. One piece motor body and cartridge element construction permit interchange to adapt the unit to a wide variety of flow capacities and ease repair with minimum disassembly and number of spare parts. Fluid viscosities between 55 and 275 SSU are recommended at normal operating temperatures of 120F with a maximum of 180F. Most vane motors are not recommended for use with water-based emulsion fire-resistant fluids .

Figure 3.3.6. Balanced vane motor operation (Courtesy of Sperry Vickers)

Piston type motors Piston motors are the most like their pump counterparts and incorporate only minor changes to effect the conversion. They are available in both axial and radial designs. In-line-type motors are similar to pumps and make use of both the fixed displacement swash plate and variable displacement adjustable yoke. Bent axis motors are available with fixed displacement angles as well as variable displacement angles. Radial piston motors are used widely in low speed, high torque applications. Piston motors also operate at the highest efficiencies, speeds, and pressures available.

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 8

3.3. Hydraulic motor 2012 Fixed displacement in-line swash plate motors commonly use nine pistons with the swash plate at 15 (Fig. 3.3.7). They are available in single or double shaft versions. Reversal of the motor is accomplished only by reversing the direction of fluid flowing through the motor.

Figure 3.3.7. Fixed displacement in-line piston motor (courtesy of Sperry Vickers).

When used as a motor, hydraulic pressure on the piston create s tangential force s on the angled swash plate (Fig. 3.3.8). This gives the required turning moment to the shaft. As fluid is directed to the rotor through the inlet and kidney-shaped port in the valve plate, it imparts a force (F) on the pistons in line with their axis.

Figure 3.3.8. Vector forces in in-line piston motor (courtesy of Sperry Vickers).
Hydraulic and pneumatic control lecture notes by Siraj K. Page 9

3.3. Hydraulic motor 2012 The axial force is resolved into its component angle force s (FI) and (Fz). While the force (F1) is directed perpendicular to the surface of the stationary swash plate and is not available to accomplish work, the force (Fz) is in a direction parallel to the surface of the swash plate and so is free to move down the angled surface imparting motion to the piston group, cylinder block, and output shaft. Fluid under pres sure is directed to the piston s through the kidney-shaped inlet port while the piston s are descending the swash plate angle , and directed from the pistons to the exhaust port as they ascend the swash plate angle.

Variable displacement in-line piston motors differ from fixed swash plate motors in that the angle of the swash plate is changeable (Fig. 3.3.9). Angles of + 15 and -15 from the center position are common. Reversal of the motor is accomplished by tilting the yoke over center by the action of a servo yoke actuating piston or manual control. The torque from variable displacement motors varies with the change in volume displacement caused by tilting of the yoke. If the motor receives fluid at constant flow rate from the pump, a decrease in torque is accompanied by an increase in speed. The fluid horsepower of the motor is constant since the product of pressure (p) and flow rate (Q) input are constant. Neglecting losses, the horsepower output is also constant.

Bhp =

TN 5,252

Figure 3.3.9. Variable displacement in-line piston motor (courtesy of Sperry Vickers).
Hydraulic and pneumatic control lecture notes by Siraj K. Page 10

3.3. Hydraulic motor 2012 Increases or decreases in torque resulting from increases or decreases in motor displacement will be accompanied by inverse decreases or increases in motor output speed. As the angle of the actuating yoke is reduced to approach 0, the speed of the variable displacement motor increases. Further decrease in the angle of the yoke will cause the motor to stall and cause excessive pressure in the system which must be released to redirect the constant flow provided by the pump.

3.3.3. Hydraulic motor theoretical torque, power and flow rate Motors convert fluid energy back into mechanical energy and thus are the mirror image of pumps. It is not surprising that the same mechanisms are used for both. The typical motor designs are gear, vane, and piston. Motor performance is a function of pressure. As pressure increases, leakage increases, speed decreases, and thus the quantity of mechanical energy delivered to the load decreases. Due to this a hydraulic motor delivers less torque than it should theoretically. The theoretical torque (which is the torque that a frictionless hydraulic motor would deliver) can be determined by the following equation developed for limited rotation hydraulic actuators:
TT (in lb ) = VD in 3 / rev p( psi ) 2

3.3.4

Using metric units we have

VD m 3 / rev p(Pa ) TT ( N m ) = 2 Thus, the theoretical torque is proportional not only to the pressure but also to the volumetric displacement.

The theoretical horsepower (which is the horsepower a frictionless hydraulic motor would develop) can also be mathematically expressed:
TT (in lb ) N (rpm ) VD in 3 / rev p( psi ) N (rpm ) = HPT = 63,000 2

3.3.5

In metric units, theoretical power (W)


Hydraulic and pneumatic control lecture notes by Siraj K. Page 11

3.3. Hydraulic motor 2012

Theoretical power (W ) = TT ( N m ) N (rad / s ) =

VD m 3 / rev p(Pa ) N (rad / s ) 2

Also due to the leakage, a hydraulic motor consumes more flow-rate than it should theoretically. The theoretical flow-rate is the flow-rate a hydraulic motor consume if there where no leakage. As is the case for pumps, the following equation gives the relationship among speed, volumetric displacement and theoretical flow-rate.

QT ( gpm ) =
Or

VD in 3 / rev N (rpm ) 231

3.3.6

QT m 3 / s = VD m 3 / rev N (rev / s )

3.3.7

3.3.4. Hydraulic motor performance The performance of any hydraulic motor depends on the precision of its manufactures as well as the maintenance of close tolerances under design operating conditions. As in the case for pumps, internal leakage (slippage) between the inlet and outlet reduces the volumetric efficiency of a hydraulic motor. Similarly, friction between mating parts and due to fluid tolerance reduces the mechanical efficiency of the hydraulic motor.

Gear motors typically have an overall efficiency of 70 to 75% as compared to 75 to 85% for vane motors and 85 to 95% for piston motor. Some systems require that a hydraulic motor start under load. Such system should include a stall torque factor when making design calculations. For example only about 80% of the maximum torque can be expected if the motor is required to start either under load or operate at the speed below 500 rpm.

Motor efficiencies Hydraulic motor performance is evaluated on the same three efficiencies (volumetric, mechanical and overall efficiencies) used for hydraulic pumps. They are defined for motor as follows:

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 12

3.3. Hydraulic motor 2012 1. Volumetric efficiency (v) The volumetric efficiency of a hydraulic motor is the inverse of that for a pump. This is because a pump does not produce as much flow as it should theoretically, whereas a motor uses more flow than it should theoretically due to leakage. Thus, we have

v =

theoretical flow rate motor should consume actual flow rate consumed by motor

QT QA

3.3.8

Determination of volumetric efficiency requires the calculation of the theoretical flow-rate, which is defined for a motor. Substituting the values of calculated theoretical flow-rate and actual flow-rate (which is measured) in to equation above yields the volumetric efficiency for the given motor.

2. Mechanical efficiency (m) The mechanical efficiency of a hydraulic motor is the inverse of that for a pump. This is because due to friction, the pump requires a greater torque than it should theoretical where as a motor produces less torque than it should theoretically. Thus, we have

m =

actual torque delivered by motor torque motor should theoretically deliver

TA TT

3.3.9

The following equations (3.3. ) and (3.3. ) allow for the calculation of TT and TA, respectively:

V (in TT (in lb ) = D

/ rev p( psi ) 2

3.3.10

Using metric units we have TT ( N m ) =


T A (in lb ) =

VD m 3 / rev p(Pa ) 2
actual HP delivered by motor 63,000 N (rpm )

3.3.11

Using metric units we have


TA (N m ) = actual wattage delivered by motor 63,000 N (rad / s )

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 13

3.3. Hydraulic motor 2012 3. Overall efficiency (o) As in the case for pumps, the overall efficiency of a hydraulic motor equals the product of the volumetric and mechanical efficiencies.

o = v m =

actual power delivered by motor actual power delivered to motor

3.3.12

In English units, we have


T A (in lb ) N (rpm ) 63,000 o = p( psi ) Q A ( gpm ) 1714

3.3.13

In metric units, we have

o =

T A ( N .m ) N (rad / s ) p(Pa ) Q A m 3 / s

3.3.14

Note that the actual power delivered to a motor by the fluid is called hydraulic power and the actual power delivered to the load by a motor via a rotating shaft called brake power.

3.3.5. Hydrostatic transmissions Hydrostatic drive Introduction The hydrostatic drive is a fluid drive which uses fluid under pressure to transmit engine power to the drive wheels of the machine. Mechanical power from the engine is converted to hydraulic power by a pump-motor team. This power is then converted back to mechanical power for the drive wheels. The hydrostatic drive can function as both a clutch and transmission. The final gear train can then be simplified, with the hydrostatic unit supplying infinite speed and torque ranges as well as reverse speeds. There two basic types of hydraulic transmissions: Hydrodynamic Hydrostatic

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 14

3.3. Hydraulic motor 2012

Figure 3.3. 10 Hydrostatic drives

Figure 3.3.11 Basic type of hydraulic transmissions

Figure 3.3.12 shows one piston for the pump and one for the motor. To provide a pumping action for the pistons, a plate called a swashplate is located in both in the pump and motor. The piston
Hydraulic and pneumatic control lecture notes by Siraj K. Page 15

3.3. Hydraulic motor 2012 against the swashplates. The angle of the swashplates (figure 3.3.12) can be varied so that the volume and pressure of oil pumped by the pistons can be changed or the direction of oil flow reversed.

Figure 3.3.12 Two connected cylinders with swashplates A pump or motor with a movable swashplate is called a variable-displacement unit. A pump or motor with a fixed swashplate is called a fixed displacement unit. Figure 3.3.13 shows a variable displacement pump driving a fixed displacement motor. As the pump pistons rotate, they move across the sloping face of the swashplate, sliding in and out of their cylinder bores to pump oil out. The more the pump swashplate is tilted, the more oil it pumps with each piston stroke and faster it drives the motor.

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 16

3.3. Hydraulic motor 2012

Figure 3.3.13 Variable displacement pump driving fixed displacement motor

Pressure results whenever the flow of a fluid is resisted. The resistance may come from acceleration of the machine or normal load. The motor swashplate is at a fixed angle so that the strokes of its pistons are always the same. Thus its speed of rotation can not be changed except as it is driven faster or slower by the pump oil. The point to remember now is that a given volume of oil forced out of the pump will cause the motor to turn at a given speed. More oil will speed up the motor; less oil will slow it down. The pump is driven by the machines engine and so is linked to the speed set by the operator. It pumps a constant stream of high-pressure oil to the motor.

Since the motor is linked to the drive wheels of the machine, it gives the machine its travel speed. Only three factors control the operation of a hydrostatic drive: Rate of oil flow-gives the speed Direction of oil flow-gives the direction Pressure of oil-gives the power

Control of these three factors is infinite, giving endless selections of speed and torque in a hydrostatic drive. The pump-motor team is the heart of the hydrostatic drive, although the complete hydraulic system (figure 3.3.14) also includes a reservoir to supply the oil, a filter to remove dirt, and a cooler to remove excess heat from the oil.

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 17

3.3. Hydraulic motor 2012

Figure 3.3.14 Complete system for a hydrostatic drive (closed hydraulic loop)

Basically however, the pump and motor are joined in a closed hydraulic loop; the return line from the motor is joined directly to the intake of the pump, rather than to the reservoir. The charge pump simply supplies the oil, drawing it from the resorvoir.

Types of hydrostatic drives Displacement is the quantity of fluid which a pump can move (or motor can use) during each revolution. It is directly related to the horsepower output of the drive. (Horsepower is a combination of torque x speed.) As you have already learned, pumps and motors can have a fixed dispacement or variable displacement. Four pump-motor combinations are possible: 1. Fixed displacement pump driving a fixed displacement motor. 2. Variable displacement pump driving a fixed displacement motor. 3. Fixed displacement pump driving a variable displacement motor. 4. Variable displacement pump driving a variable displacement motor.

The point tor remember is that for each combination the output power must equal the input power minus negligible power losses. Lets look at each combination (figure 3.3.15).

No. 1 circuit is like a gear drive; it transmits power without altering the speed or horsepower between the engine and the load. A constant input speed and torque gives a constant output
Hydraulic and pneumatic control lecture notes by Siraj K. Page 18

3.3. Hydraulic motor 2012 horsepower. If either the speed or torque is increased holding the other constant the output horsepower will increase.

Since the pump flow is variable in No. 2 circuit, the output speed is variable and torque output is constant for any given pressure. This circuit gives variable speed and constant torque.

Output speed in No. 3 circuit is varied by changing the motor displacement. For constant power input if the motor displacement decreases, output speed increases but output torque drops.

No. 4 circuit is the most flexible and expensive of the circuits but also the most difficult to control. It is capable of operating like any of the above combinations.

Figure 3.3.15 Pump-motor combinations for hydrostatic drives

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 19

3.3. Hydraulic motor 2012

Hydraulic and pneumatic control lecture notes by Siraj K.

Page 20

Anda mungkin juga menyukai