Anda di halaman 1dari 16

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

Copyright 2010 All rights reserved Integrated Publishing services

Research article

ISSN 0976 4399

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups
Bindhu K.R1, Sreekumar K.J2 1-Assistant Professor, Department of Civil Engineering, College of Engineering, Thiruvananthapuram, Kerala, India 2-P. G. Student, Dept. of Civil Engineering, College of Engineering, Thiruvananthapuram, Kerala, India kj_sreekumar@yahoo.co.in doi:10.6088/ijcser.00202010100 ABSTRACT The performance of beam-column joints have long been recognized as a significant factor that affects the overall behaviour of reinforced concrete (RC) framed structures subjected to large lateral loads. The reversal of forces in beam-column joints during earthquakes may cause distress and often failure, when not designed and detailed properly. In the present study, four one third scaled exterior beam-column joint specimens were prepared with only one of them conforming to the guide lines of IS 13920: 1993 for seismic resistant design. Second one was detailed with additional diagonal collar stirrups at joints and beam reinforcements and the third one is cast without collar stirrups but having additional beam reinforcements. The fourth specimen was having same longitudinal reinforcements of the first specimen but with increased spacing of ties in the joint region. All the specimens were subjected to similar reverse cyclic loading to simulate earthquake loading in structures. The loading was applied by displacement control mode. Based on the experimental findings and subsequent analysis, it is found that, second specimen having additional beam reinforcements and diagonal collar stirrups at joints exhibits a better performance than the others. Keywords: Beam-column joint, ductility, energy dissipation, reinforcement details, ultimate load 1. Introduction The performance of beam-column joints have long been recognized as a significant factor that affects the overall behaviour of reinforced concrete (RC) framed structures subjected to large lateral loads. The beam-column joints that are not detailed and built in accordance with seismic codes present a serious hazard that can affect the overall ductility of a structure subjected to severe earthquake shocks. The failure of reinforced concrete structures in recent earthquakes in several countries has caused concern about the performance of beam-column joints (Durrani and Wight 1985). Since past three decades extensive research has been carried out on studying the behaviour of joints under seismic conditions through experimental and analytical studies. Various international codes have been going periodic revisions (Tsonos 2007). Among the Indian codes IS 13920:1993 deals with ductile detailing of reinforced concrete structures subjected to seismic forces. However, despite the significance of the joints in sustaining large deformations and forces during earthquakes, specific guidelines are not explicitly included in

Received on July, 2011 Published on September 2011

160

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

Indian codes of practice (IS 456: 2000, IS 1893 : 2002, IS 13920: 1993, SP 34:1987). One of the basic assumption of the frame analysis is that the joints are strong enough to sustain the forces (moments, axial and shear forces) generated by the loading, and to transfer the forces from one structural element to another (beams to column, in most of the cases). Confinement of joint can be done to satisfy the above condition (Asha and Sundarrajan 2006, Bindhu et al. 2008, Bindhu et al. 2009a). 2. Present Study The main objectives of the present study was to confine the R.C beam column joint by providing diagonal collar stirrups at joint region and to investigate the strength, ductility and energy dissipation capacity of beam-column joint specimens having various reinforcement arrangements and thereby to compare the behaviour of the specimens made of nonconventional confining reinforcement pattern with conventional reinforcement pattern as per IS 13920: 1993. An eight storey building was modelled and analyzed using STAAD Pro. A typical exterior beam-column joint of the building was designed and detailed as per IS 13920:1993 and scaled to the laboratory conditions (Tsonos et al. 1992, Tsonos 2000, Murty et al. 2001, Murty et al. 2003, Jain and Murty 2005 a, Jain and Murty 2005 b, Ingle and Jain 2005, Bindhu et al. 2009b). 2.1 Details of Beam-Column Joint The experimental program included four 1/3 scaled specimens (C1, C2, C3 & C4). The specimen C1 was conforming to IS 13920, C2 with additional beam reinforcements and diagonal collar stirrups over C1, C3 with additional beam reinforcements over C1 and C4 similar to C1 but with increased spacing of ties at joint. The size of the beam was 800 mm x 100 mm x 150 mm and column 1000 mm x 100 mm x 150 mm. The dimensions and reinforcement details of test assemblages are shown in Fig.1 and Fig.2. 3. Casting of Specimens The cement used was Ordinary Portland Cement 43 grade conforming to IS 8112:1989. River sand passing through 4.75 mm IS sieve and having a fineness modulus of 3.16 was used as fine aggregate. Crushed granite stone of maximum size not exceeding 12.5 mm was used as coarse aggregate. The mix was designed in proportion of 1:1.33:2.47 by weight respectively and the watercement ratio was kept as 0.45. The 28 day average compressive strength from 150 mm cube test was 34.55 N/mm2. The reinforcement cages used for different specimens are shown in Fig.3. The specimens were cast in horizontal position inside wooden moulds and were demoulded after 24 hours and then cured in water tank.

161
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

6 Nos. 8mm TOR.

3mm TOR TIES.

3mm TOR TIES @ 50 mm C/C.

3mm TOR TIES @ 25 mm C/C.

3mm TOR STIRRUPS @ 35 mm C/C.

3mm TOR STIRRUPS @ 50 mm C/C.

2 Nos. 8mm TOR.(TOP.)

2 Nos. 8mm TOR.(BOTTOM.)

3mm TOR TIES @ 25 mm C/C. 3mm TOR TIES @ 50 mm C/C.

REINFORCEMENT DETAILS FOR SPECIMEN C1.

6 Nos. 8mm TOR.

3mm TOR TIES.

3mm TOR TIES @ 50 mm C/C.

3mm TOR TIES @ 25 mm C/C.

3mm TOR STIRRUPS @ 35 mm C/C.

3mm TOR STIRRUPS @ 100 mm C/C.

3mm TOR STIRRUPS @ 50 mm C/C.

3mm STIRRUPS. ( 100mm c/c/.) 2 Nos. 6mm TOR.(TOP.) 2 Nos. 8mm TOR.(TOP.) 3mm STIRRUPS. ( 50mm c/c.) 2 Nos. 8mm TOR.(BOTTOM.) 2 Nos. 8mm TOR.(BOTTOM.)

3mm TOR TIES (2 Nos.)

3mm TOR TIES @ 25 mm C/C. 3mm TOR TIES @ 50 mm C/C.

REINFORCEMENT DETAILS FOR SPECIMEN C2.

Figure 1: Reinforcement details for Specimens C1 and C2 162


International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

6 Nos. 8mm TOR.

3mm TOR TIES.

3mm TOR TIES @ 50 mm C/C.

3mm TOR TIES @ 25 mm C/C.

3mm TOR STIRRUPS @ 35 mm C/C.

3mm TOR STIRRUPS @ 100 mm C/C.

3mm TOR STIRRUPS @ 50 mm C/C.

3mm STIRRUPS. ( 100 mm c/c.) 2 Nos. 6mm TOR.(TOP.) 2 Nos. 8mm TOR.(TOP.) 3mm STIRRUPS. ( 50mm c/c/.) 2 Nos. 8mm TOR.(BOTTOM.) 2 Nos. 8mm TOR.(BOTTOM.)

3mm TOR TIES @ 25 mm C/C. 3mm TOR TIES @ 50 mm C/C.

REINFORCEMENT DETAILS FOR SPECIMEN C3.

6 Nos. 8mm TOR.

3mm TOR TIES.

3mm TOR TIES @ 50 mm C/C.

3mm TOR STIRRUPS @ 50 mm C/C.

2 Nos. 8mm TOR.(TOP.)

2 Nos. 8mm TOR.(BOTTOM.)

3mm TOR TIES @ 50 mm C/C.

REINFORCEMENT DETAILS FOR SPECIMEN C4.

Figure 2: Reinforcement Details for Specimens C3 and C4 163


International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

Figure 3: Reinforcement Cages Prepared for Different Specimens

164
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

3.1 Experimental Setup The test set up in the laboratory is shown in Fig. 4. The specimens were tested in an up right position and static reverse cyclic loading was applied. Both ends of the column were hinged properly within the self straining test frame. A deflection control test was conducted in which the specimen was subjected to an increasing deflection with increments not exceeding 2.5 mm up to the failure. The specimens were instrumented with hydraulic jacks, LVDTs, dial gauges and strain gauges to monitor the behavior during testing. Lateral loading, at deflection increments of 2.5 mm was applied in a cyclic manner by means of hydraulic jacks having a capacity of 100 kN and 200 kN for downward and upward loading respectively. It was applied at a distance of 100 mm from the free end of the beam until failure of the specimens. One dial gauge was placed at the loading point of beam to control deflection at the point of application of load. Electrical resistance strain gauges were pasted on the reinforcement in order to measure strains. The specimens were evaluated in terms of ultimate load carrying capacity, load displacement relationship, and energy dissipation characteristics.

Figure 4: Test Setup in the Laboratory 3.2 Crack Pattern and Failure Mode The crack patterns in different specimens are shown in Fig. 5. For specimen C1 and C2, the initial diagonal and column beam interface hairline cracks occurred in the third cycle of loading in positive direction and fifth cycle of loading in negative direction. For specimen C2, further cracks were developed at the column beam interface only after sixth cycle in both positive and negative direction. However, in specimen C3, the cracks in the joint at diagonal direction started after third cycle of loading in positive direction and fifth cycle of loading in negative direction. The specimen C2 failed due to the advancement of crack width at the interface between column and beam. Among the specimens, C2 specimen which was additionally detailed with collar stirrups and beam reinforcements exhibited the best performance. For this specimen, no major cracks were noticed at the joint and the joint 165
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

remained intact through out the test. Hence the failure was dominated by tensile failure than the joint failure. The improvement of performance by developing further cracks away from the joint face to the beam region can be noticed for the specimen with collar stirrups. The crack width is also less for this specimen compared to other specimens. The specimen C3 and C4 without collar stirrups have diagonal cracks at the beam-column joint region. This may be due to the higher flexural capacity of beam compared to the column.

Figure 5: Crack Patterns of Different Specimens 3.3 Ultimate Load Carrying Capacity of Specimens The ultimate load carrying capacities of all the specimens were observed and Fig.6 shows the comparison of the same. For the specimen C1 detailed as per IS 13920: 1993, the ultimate load is 38 kN. But for the specimen C2 detailed as per IS 13920: 1993 with collar stirrups and additional beam reinforcements, the ultimate load is 72 kN. Incase of the specimen C3 166
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

detailed without collar stirrups at joint but with additional beam reinforcements, the ultimate load reached is 65 kN.

80

70

60

50
Load in KN

40

30

20

10

0 C1 C2 C3 C4

Specimens

Figure 6: Comparison of Ultimate Load Carrying Capacity of Different Specimens Similarly for the specimen C4 which is similar to C1 but with increased spacing of ties in joints, ultimate load reached is 35 kN. These results show the effectiveness of the diagonal collar stirrups with additional beam reinforcement in the enhancement of ultimate load carrying capacity. 3.4 Hysteretic Loops The hysteretic loops of the load displacement relationship for the four specimens tested in the laboratory are shown in Fig. 7 through Fig.10. It is observed that the specimen C2 with 167
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J
100.00

80.00

Load in kN
-25 -20 -15 -10 -5

60.00

40.00

20.00

0.00 0 5 10 15 20 25

-20.00

Deflection in mm

Figure 7: Load-Displacement Hysterisis Loop for Specimen C1


100.00

80.00

60.00

Load in kN
-25 -20 -15 -10 -5

40.00

20.00

0.00 0 5 10 15 20 25

-20.00

Deflection in mm

Figure 8: Load-Displacement Hysterisis Loop for Specimen C2

168
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J
100.00

80.00

60.00

Load in kN
-25 -20 -15 -10 -5

40.00

20.00

0.00 0 5 10 15 20 25

-20.00

Deflection in mm

Figure 9: Load-Displacement Hysterisis Loop for Specimen C3


100.00

80.00

Load in kN
-25 -20 -15 -10 -5

60.00

40.00

20.00

0.00 0 5 10 15 20 25

-20.00

Deflection in mm

Figure 10: Load-Displacement Hysterisis Loop for Specimen C4 additional beam reinforcement and diagonal collar stirrups developed better hysteretic loops with higher curve area compared with other specimens. The performance of the specimen C2 over the specimen C3 shows the enhanced strength and behaviour of joints with diagonal collar stirrups. 3.5 Ductility The displacement ductility factor is the ratio of the maximum deformation that an element can undergo without significant loss of initial yield resistance to the initial yield deformation (Park and Paulay 1975). Fig. 11 through Fig.14 shows the lateral load displacement envelope 169
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

curves of all the specimens. Table 1 gives the experimental results of ductility factor. It can be seen that the specimen C2 detailed with diagonal collar stirrups at joint and additional beam reinforcements had more ductility than that detailed without collar stirrups.
80.00

70.00

60.00

50.00

Load in kN
-25.00 -20.00 -15.00 -10.00 -5.00

40.00

30.00

20.00

10.00

0.00 0.00 -10.00

5.00

10.00

15.00

20.00

25.00

-20.00

Defflection in mm

Figure 11: Load Displacement Envelope for C1

80.00

70.00

60.00

50.00

Load in kN
-25.00 -20.00 -15.00 -10.00 -5.00

40.00

30.00

20.00

10.00

0.00 0.00 -10.00

5.00

10.00

15.00

20.00

25.00

-20.00

Deflection in mm

Figure 12: Load-Displacement Envelope for C2

170
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

80.00

70.00

60.00

50.00

Load in kN
-25.00 -20.00 -15.00 -10.00 -5.00

40.00

30.00

20.00

10.00

0.00 0.00 -10.00

5.00

10.00

15.00

20.00

25.00

-20.00

Deflection in mm

Figure 13: Load-Displacement Envelope for C3

80.00

70.00

60.00

50.00

load in kN
-25.000 -20.000 -15.000 -10.000 -5.000

40.00

30.00

20.00

10.00

0.00 0.000 -10.00

5.000

10.000

15.000

20.000

25.000

-20.00

Deflection in mm

171
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

Figure 14: Load-Displacement Envelope for C4 Table 1: Displacement Ductility of Test Specimens Displacement in mm Specime n Yield + Ultimate + directio n C1 C2 C3 C4 7.50 5.00 7.50 5.00 5.00 5.00 7.50 5.00 17.50 22.5 22.50 15.00 directio n 17.50 22.50 17.50 17.50 Displacement ductility + directio n 2.33 4.50 3.00 3.00 directio n 3.50 4.50 3.50 3.50 2.92 4.50 3.25 3.25 Average displace ment ductility

direction direction

4. Energy Dissipation Capacity Structures with high energy dissipation characteristics are able to withstand stronger shaking and better seismic response. The amount of energy dissipated during a particular loading cycle is calculated as the area enclosed by the corresponding load versus displacement hysteretic loop (Paulay et al. 1978). The cumulative energy dissipated is given in Table 2. Table 2: Cumulative Energy Dissipation for Various Specimens

Sl No. 1 2 3 4

Specimen designation C1 C2 C3 C4

Energy dissipation (kN-mm) 922.16 1187.73 974.43 864.25

Fig. 15 shows the energy dissipation capacity versus number of cycles. It can be seen that, in the first four cycles, the specimens do not have greater energy dissipation. However, in the final cycles, the specimens have greater dissipated energy. The reason is that higher lateral load produces greater area (dissipated energy) bounded by the load displacement curve. It is clearly observed that the specimen detailed with diagonal collar stirrups and additional beam reinforcements had more energy dissipation capacity than the others. 172
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

250

Energy dissipation capacity in kN-mm

200 C1 C2 C3 C4

150

100

50

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

No.of cycles

Figure 15: Comparison of Energy Dissipation in Each Cycle of All Specimens 5. Conclusions Seismic performance of reinforced concrete moment resisting framed structures mainly depends upon the inelastic behaviour of joints. Based on the experimental investigation conducted on exterior beam-column joint under static reverse cyclic loading, the following conclusions are drawn. The load carrying capacity of the specimen additionally reinforced with beam and diagonal collar stirrups (C2) is nearly 98 % higher than the specimen detailed as per IS 13920(C1) and 10 % more than the specimen with additional beam reinforcements (C3). Also the specimen detailed with increased spacing of ties at joints gave unfavorable results; i.e., a reduction of 10 % with regard to load carrying capacity (C4). Ductility of the specimen additionally detailed with diagonal collar stirrups and beam reinforcements is compared and found that it is 54 % higher than that of the specimen detailed as per IS 13920: 1993 without collar stirrups, and 5 % higher than specimen detailed as per IS 13920, but having additional beam reinforcement. Energy dissipation capacity of the specimen detailed additionally with diagonal collar stirrups and beam reinforcements is observed to be 22.36 % higher than that of the specimen detailed as per IS: 13920: 1993.

Acknowledgements The research presented in this paper has been supported through a project entitled A study of strengthening of joints in multistory RC structures subjected to seismic loading awarded to 173
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

College of Engineering, Trivandrum by All India Council for Technical Education through research promotion scheme. The authors gratefully acknowledge the AICTE for the same. 6. References 1. Asha, P and Sundararajan, R., (2006), Evaluation of seismic resistance of exterior beam-column joints with detailing as per IS 13920: 1993, Indian Concrete Journal, 33(1), pp. 29-34. 2. Bindhu, K.R., Jaya, K.P. and Manicka Selvam, V.K., (2008), Seismic resistance of Exterior beam-column joints with non-conventional confinement reinforcement detailing, Journal of Structural Engineering and Mechanics, An International Journal, 30(6), pp.733-761. 3. Bindhu, K.R., Jaya, K.P. and Manicka Selvam, V.K., (2009a), Behaviour and strength of exterior joint sub assemblage subjected to reversal loadings, Indian Concrete Journal, 83 (11), pp.9-20. 4. Bindhu, K.R., Sukumar, P.M and Jaya, K.P., (2009b), Performance of Exterior Beam-Column Joints under Seismic Type Loading, ISET Journal of Earthquake Technology, 46(2), pp.47-64. 5. Durrani, A.J. and Wight, J.K., (1985), Behavior of Interior Beam-to-Column Connections Under Earthquake-Type Loading, ACI Structural Journal, 82(3), pp.343-349. 6. Ingle, R.K. and Jain, S.K., (2005), Explanatory examples for ductile detailing of R.C buildings, Report IITK GSDMA-EQ22-V3.0, IIT Kanpur, Kanpur. 7. IS 13920:1993, Indian Standard Ductile Detailing of Reinforced Concrete Structures subjected to Seismic forces, Bureau of Indian Standards, New Delhi, India. 8. IS 1893 (Part 1):2002, Indian Standard Criteria for earthquake Resistant Design of Structures, Bureau of Indian Standards, New Delhi, India. 9. IS 456:2000, Indian Standard Plain and Reinforced Concrete Code of Practice, Bureau of Indian Standards, New Delhi, India. 10. Jain, S.K. and Murty, C.V.R. (2005a), Proposed Draft Provisions and Commentary on Indian Seismic code IS 1893(Part 1), Report IITK-GSDMA-EQ 05-V4.0/ IITKGSDMA-EQ 15-V3.0, IIT Kanpur, Kanpur. 11. Jain, S.K. and Murty, C.V.R. (2005b), Proposed Draft Provisions and Commentary on Ductile Detailing of RC Structures Subjected to Seismic forces, Report IITKGSDMA-EQ 11-V4.0/IITK-GSDMA EQ16-V3.0, IIT, Kanpur, Kanpur. 12. Murty, C.V.R., Durgesh, C.R., Bajpai, K.K. and Sudhir, K.J., (2001), Anchorage details and joint design in seismic R.C frames, The Indian Concrete Journal, 75(4), pp.274-280. 13. Murty, C.V.R., Durgesh, C.R., Bajpai, K.K. and Sudhir, K.J., (2003), Effectiveness of Reinforcement Details in Exterior Rreinforced Concrete Beam- Column Joints for Earthquake Resistance, ACI structural journal, 100 (2), pp.149-155. 14. Park, R. and Paulay, T., (1975), Reinforced Concrete Structures, John Wiley and Sons, New York. 174
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Seismic Resistance of Exterior Beam Column Joint with Diagonal Collar Stirrups Bindhu K.R, Sreekumar K.J

15. Paulay, T., Park, R. and Priestley, M.J.N., (1978), Reinforced Concrete BeamColumn Joints under Seismic Actions, ACI structural journal, 75(11), pp.585-593. 16. SP 34:1987, Indian Standard Handbook on Concrete Reinforcement and Detailing, Bureau of Indian Standards, New Delhi, India. 17. Tsonos, A.G., Tegos, I.G and Penelis, G.Gr., (1992), Seismic Resistance of Type 2 Exterior Beam-Column Joints Reinforced with Inclined Bars, ACI Structural Journal, 89(1), pp.3-12. 18. Tsonos, A.G., (2000), Effect of vertical hoops on the behavior of reinforced concrete beam-column connections, European Earthquake Engineering, 2, pp.13-26. 19. Tsonos, A.G., (2007), Cyclic Load Behavior of Reinforced Concrete Beam-Column Subassemblages of Modern structures, ACI Structural Journal, 104 (4), pp.468-478.

175
International Journal of Civil and Structural Engineering Volume 2 Issue 1 2011

Anda mungkin juga menyukai