Anda di halaman 1dari 6

MINISTRY OF ENERGY

IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN 6159 M.W. GAS TURBINE POWER PLANT

STEAM TRACE PROCESS DESCRIPTION

KHERAD WATER TREATMET COMPANY

D C B A 0 REV.
ISSUED FOR APPROVAL DESIGNATION

FEB.2005
DATE

M.Z
DESIGN

FEB.2005
DATE

S.H
CHKD

FEB.2005
DATE

E.A.
APPROV

FEB.2005
DATE

MAPNA DOC. NO. MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007

REV. :0

Page 1 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION MF CODE: --REV.0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

MINISTRY OF ENERGY
IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN 6159 M.W. GAS TURBINE POWER PLANT


Page

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Revisions 0 A B

Page

E 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90

Revisions 0 A B

Remarks C D E

KHERAD WATER TREATMET COMPANY

D C B A 0 REV.
ISSUED FOR APPROVAL DESIGNATION

FEB.2005
DATE

M.Z
DESIGN

FEB.2005
DATE

S.H
CHKD

FEB.2005
DATE

E.A.
APPROV

FEB.2005
DATE

MAPNA DOC. NO. MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007

REV. :0

Page 2 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION MF CODE: --REV.0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

MINISTRY OF ENERGY
IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN GAS TURBINE POWER PLANT ( BOP2 Portion )

TABLE OF CONTENTS
1. 2. 3. 4. 5. 6. LIST OF REFERENCE DOCUMENTS SITE LOCATION AMBIENT & SITE CONDITIONS SCOPE STEAM PANEL CONDENSATE PANEL

KHERAD WATER 1. LIST OF REFERENCE DOCUMENTS TREATMET COMPANY

MAPNA DOC. NO. : MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007 MF CODE:

REV. : 0

Page 3 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION --REV. 0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

MINISTRY OF ENERGY
IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN GAS TURBINE POWER PLANT ( BOP2 Portion )

A) Steam trace P&ID unloading system 22IE-02-SB0-001 B) Steam trace P&ID forwarding system SVG-22IE-02-SB0-002

MP-SVGMP-

C) AUX.Steam Distribution & Condensate Return SYS. P&ID MP-SVG22IE-02-SB0-003 D) Steam trace Design Criteria SVG-22ME-28-SB0-001 2. SITE LOCATION SHIRVAN gas turbine power plant is located approximately at 9 km north of SHIRVAN.
3.

MP-

AMBIENT AND SITE CONDITIONS

The SHIRVAN gas turbine power plant consists of 6X159 MW (at ISO condition) gas turbines. Ambient and geotechnical condition of SHIRVAN power plant are mentioned in the following texts: Site elevation level Max. Ambient Temp. Min. Ambient Temp. Design Temp. Average humidity Design Wind Velocity Prevailing wind direction
Voltage Level
KHERAD WATER TREATMET COMPANY

: 1115 m Above sea : +42.3 C : -30 C : 15 C : 56% : 144 Km/hr : W to E

MAPNA DOC. NO. : MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007 MF CODE:

REV. : 0

Page 4 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION --REV. 0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

MINISTRY OF ENERGY
IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN GAS TURBINE POWER PLANT ( BOP2 Portion )

LV MV

: 400 VAC,3 phase ,50Hz : 230 VAC,1phase ,50Hz : 6.6 kV,3 phase,50 Hz

4.

SCOPE

The purpose of this document is to describe fuel steam tracing, which ensures prevention of gas oil line from freezing and maintains the gas oil temperature sufficiently 10 C above pour point, and makes it suitable for pumping and burning in turbines burners. 5. STEAM PANEL

All Gas Oil piping are traced by means of DN 15 steel pipes on the pipe length parallel to pipe axis to keep Gas Oil temperature 10 C above Gas Oil pour point. For pipe size of smaller than or equal to DN 100 one DN 15 tracing pipe has been foreseen and for pipe size of larger than DN 100 two DN 15 tracing pipes have been foreseen. Because of heat transfer between steam and Gas Oil, steam miss the initial quality and converts into condensate therefore a fresh steam should be provided each 30~50 m. To meet this purpose a steam feed panel is provided at intervals of 60~100 m. Each 2-6 tracing pipes are gathered at one steam panel .Necessary branches are drawn from this panel running in both directions. There is one pressure gauge in inlet of steam pipe of each steam panel to indicate the operating pressure of steam distribution system. Steam
KHERAD WATER TREATMET COMPANY

MAPNA DOC. NO. : MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007 MF CODE:

REV. : 0

Page 5 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION --REV. 0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

MINISTRY OF ENERGY
IRAN POWER DEVELOPMENT COMPANY

I.P.D.C. PROJECT : SHIRVAN GAS TURBINE POWER PLANT ( BOP2 Portion )

header of each panel is isolated from main steam line by one gate valve. 6. CONDENSE PANEL Condensate which have been produced due to the heat transfer between steam and gas oil to keep the fuel oil temperature 10 C above pour point, are directed to condensate headers after passing through the steam traps at trap panels. Since at different ambient temperature, all steam may or may not be fully condensed, from economical consideration, and also to prevent mixing steam with condensate and in order to avoid cavitations, at end of each tracing line, in condensate panel one thermodynamic steam trap with strainer is laid .Condensate will be collected from each tracer at the opposite side.Distance between condensate panels is 60-100 m . For maintenance purpose each trap has two isolating valves and a by pass valve. All the condensates collected from one panel, is directed via a main line to condensate return header. Each outlet condensate panel line is provided with one isolating gate valve and one drain valve.

KHERAD WATER TREATMET COMPANY

MAPNA DOC. NO. : MP-SVG-22IE-04-SB0-001 CONTRACT NO. : SV-0602/HA/TL SE CODE : MIR.DOC. NO. 9007 MF CODE:

REV. : 0

Page 6 of 6

FILE NAME : STEAM TRACE SYSTEM DESCRIPTION --REV. 0

ORIG. LOC.

ORIG. DEPT.

PROG. NAME

DISC.

DOC. TYPE

AREA TYPE

SYS. SEQ. FA.NO. NO.

SH. NO.

Anda mungkin juga menyukai