in Company: Specifier: Address: Phone I Fax: E-Mail: Specifier's comments: chennai structure sethumahadevan 89 b/2 11 th cross 9884499167 | sethu.chennai@gmail.com conn B Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.2.6


1 centop road 5/17/2012

1. Input data

Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report:: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile Base material: Reinforcement:

HSL-3-B, M16 h ef = 100 mm 8.8 ETA 02/0042 1/10/2008 | 1/10/2013 Engineering judgement SOFA - based on ETAG testing e b = 0 mm (no stand-off); t = 12 mm lx x l y x t = 600 x 350 x 12 mm (Recommended plate thickness: not calculated) IPB/HEB; (L x W x T x FT) = 300 mm x 140 mm x 7 mm x 7 mm cracked concrete , C20/25, f cc = 25.00 N/mm; h = 230 mm no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm) no longitudinal edge reinforcement Reinforcement to control splitting according to ETAG 001, Annex C, 5.2.2.6 present.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: chennai structure sethumahadevan 89 b/2 11 th cross 9884499167 | sethu.chennai@gmail.com Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.2.6


2 centop road 5/17/2012

2. Load case/Resulting anchor forces


Load case (Design loads): Anchor reactions [kN] Tension force: (+Tension, -Compression) Anchor 1 2 3 4 5 6 7 8 Tension force 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Shear force 5.625 5.625 5.625 5.625 5.625 5.625 5.625 5.625 Shear force x 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Shear force y -5.625 -5.625 -5.625 -5.625 -5.625 -5.625 -5.625 -5.625 4 5 1 6 y

2 7 x

3 8

max. concrete compressive strain []: 0.00 max. concrete compressive stress [N/mm]: 0.00 resulting tension force in (x/y)=(0/0) [kN]: 0.000 resulting compression force in (x/y)=(0/0) [kN]: 0.000

3. Tension load
Proof Steel Strength* Pullout Strength* Concrete Breakout Strength** Splitting failure** * anchor having the highest loading Load [kN] N/A N/A N/A N/A Capacity [kN] N/A N/A N/A N/A Utilization bN [%] N/A N/A N/A N/A Status N/A N/A N/A N/A

**anchor group (anchors in tension)

4. Shear load
Proof Steel Strength (without lever arm)* Steel failure (with lever arm)* Pryout Strength** Concrete edge failure in direction y-** * anchor having the highest loading Steel Strength (without lever arm) VRk,s [kN] 101.100 g M,s 1.250 V Rd,s [kN] 80.880 VSd [kN] 5.625 **anchor group (relevant anchors) Load [kN] 5.625 N/A 45.000 45.000 Capacity [kN] 80.880 N/A 170.667 47.686 Utilization bV [%] 7 N/A 26 94 Status OK N/A OK OK

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Pryout Strength Ac,N [mm ] 320000 e c1,V [mm] 0 NRk,c [kN] 36.000
0 2

PROFIS Anchor 2.2.6


chennai structure sethumahadevan 89 b/2 11 th cross 9884499167 | sethu.chennai@gmail.com Page: Project: Sub-Project I Pos. No.: Date: 3 centop road 5/17/2012

Ac,N [mm ] 90000 y ec1,N 1.000 g M,c,p 1.500

c cr,N [mm] 150 e c2,V [mm] 0 VRd,c1 [kN] 170.667

s cr,N [mm] 300 y ec2,N 1.000 VSd [kN] 45.000

k-factor 2.000 y s,N 1.000 y re,N 1.000

Concrete edge failure in direction ylf [mm] 100 c 1 [mm] 250 y s,V 1.000 VRk,c [kN] 54.801
0

d nom [mm] 24 Ac,V [mm ] 287500 y h,V 1.277 g M,c 1.500


2

k1 1.700 A c,V [mm ] 281250 y a,V 1.000 V Rd,c [kN] 47.686


0 2

a 0.063

b 0.063

e c,V [mm] 0 VSd [kN] 45.000

y ec,V 1.000

y re,V 1.000

5. Displacements
The displacement of the highest loaded anchor should be calculated according to the relevant approval. The displacement due to hole tolerances can be neglected, because this method assumes that no hole clearance between anchors and fixture is present. The characteristic loads of the highest loaded anchor are NSk VSk = = 0.000 [kN] 45.000 [kN]

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

6. Warnings
The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means. The compliance with current standards (e.g. EC3) is the responsibility of the user An SLS-check is not performed for SOFA and has to be provided by the user! Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software considers that the grout is installed under the anchor plate without creating air voids and before application of the loads. To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: chennai structure sethumahadevan 89 b/2 11 th cross 9884499167 | sethu.chennai@gmail.com Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.2.6


4 centop road 5/17/2012

7. Installation data
Anchor plate, steel: Anchor type and diameter: HSL-3-B, M16 Profile: IPB/HEB, 300 mm x 140 mm x 7 mm x 7 mm Installation torque: 0.081 kNm Hole diameter in the fixture: df = 26 mm Hole diameter in the base material: 24 mm Plate thickness (input): 12 mm Hole depth in the base material: 125 mm Recommended plate thickness: not calculated Minimum thickness of the base material: 200 mm Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Annular gap must be removed by e.g. filling the holes with mortar of sufficient compressive strength.

85.1 4 25.0 1 2 3 175.0

x 5 6 7 8 164.9 50.0 300.0 300.0 50.0 175.0 c +x -

Coordinates Anchor [mm] Anchor x y 1 -50 90 2 50 90 3 250 90 4 -250 90

c -x -

c +x -

c -y 350 350 350 350

c +y 250 250 250 250

Anchor 5 6 7 8

x -250 -50 50 250

y -10 -10 -10 -10

c -x -

c -y 250 250 250 250

c +y 350 350 350 350

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: chennai structure sethumahadevan 89 b/2 11 th cross 9884499167 | sethu.chennai@gmail.com Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.2.6


5 centop road 5/17/2012

8. Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan