Configuring EAM in GRC 10 isnt a difficult task, but therere some details you have to take into account. The document AC 10.0 Pre-Implementation From Post-Installation to First Emergency Access is useful, but it doesnt not consider all the details. Here Ill try to give you a complete explanation about how to configure EAM successfully.
Configure Parameters: In GRC Box, execute transaction SPRO and navigate to here:
Parameter 4000Application type 4001Default Firefighter Validity Period (Days) 4002Send Email Immediately 4003Retrieve Change Log 4004Retrieve System log 4005Retrieve Audit log 4006Retrieve OS Command log 4007Send Log Report Execution Notification
Recommended value (for initial configuration) 1 30 YES YES YES YES YES YES
Immediately YES 4008Send FirefightId Login Notification 4009Log Report Execution Notification 4010Firefighter ID role name
YES
Z_SAP_GRC_SPM_FFID
For a complete description of the above parameters, please refer to the guide: https://service.sap.com/instguides - > SAP BusinessObjects Governance, Risk and Compliance (GRC) -> Acess Control -> Release 10.0 -> Maintaining Configuration Settings Guide - SAP AC 10.0
You might want to change some of them; the recommended values only serve as a guide for the initial configuration.
Changes in the parameters table will be included in a transport request, you should release the transport to your QA/PROD systems when you finish the EAM tests and adapt the parameters according to your requirements.
If youve been working with GRC 5.3, this parameter should sound weird to you.
The purpose is to identify to the application that the user who is logging on to the target system is a Firefighter ID. The target system makes a call to the GRC Box and reads this configuration to check if the user has this role assigned to them. That means that you have to create the role that youve set in parameter 4010 in all the target systems with the exact name provided there. Usually, you copy it from the standard SAP_GRC_SPM_FFID (it contains RFC authorizations). Only the users who have that role assigned in the target system will be available for selection in the GRC Box as Firefighters IDs. Kindly check note: 1668255 - Firefighter ID role name for Param ID 4010 For more information regarding default roles provided by SAP, please refer to Security Guide available here:
https://service.sap.com/instguides - > SAP BusinessObjects Governance, Risk and Compliance (GRC) -> Acess Control -> Release 10.0 -> Security Guide - SAP Access Control 10.0
At this point you have already created the connectors. Now you have to link the corresponding connectors to the SUPMG scenario:
SAP provides standard roles that must be copied to the customer namespace. For this sample configuration you should need at least to create a copy for the following roles and generate the corresponding profiles:
SAP_GRAC_NWBC
Emergency Access management owner Emergency Access management controller Emergency Access management firefighter Emergency Access management administrator Gives basic authorizations required for all AC users. You must assign this role to all AC users. Gives the authorizations to launch NWBC. You must assign this role to all AC users.
You can just name them as Z_<full standard role name> or use a naming convention according to your company requirements.
CAUTION: Please, follow he instructions provided in tha attachment of note: Note 1663949 - EAM Authorization Fixes for Central Owners and Reason Codes
There are some changes you have to made to the standard roles and also there's a complete explanation of the authorization objects.
For more information, kindly refer to the Security Guide (link provided above).
In order to show a sample for testing, Its necessary to create (or use existing ones) three users:
FF_OWNER: This user will serve as owner for the firefighter ID. It should be assigned to the role Z_SAP_GRAC_SUPER_USER_MGMT_OWNER
FF_CONTROL: This is the firefighter controller. You assign Z_SAP_GRAC_SUPER_USER_MGMT_CNTLR. CAUTION: This user MUST have a valid e-mail address maintained in SU01 if you want the controller to receive notifications via e-mail.
FIREFIGHTER: This is the firefighter user, who will be able to access in the target system with the Firefighter ID. You assign Z_SAP_GRAC_SUPER_USER_MGMT_USER in addition to the base roles. If you don't assign the base roles you won't see the user (FIREFIGHTER in this case) available for selection in the Firefighters IDs.
<your user>: The user who is going to perform the configurations, must have at least the role Z_SAP_GRAC_SUPER_USER_MGMT_ADMIN assigned.
In addition to all the mentioned roles above, all users must have the roles Z_SAP_GRAC_NWBC and Z_SAP_GRAC_BASE assigned.
For a theoretical explanation of the users and its responsibilities, refer to https://help.sap.com/saphelp_grcac10/helpdata/en/16/404938695540b398a5e76fe8cfb067/frameset.h tm
In the target system you have to make a copy of the role SAP_GRAC_SPM_FFID and generate the profile. CAUTION: The name of this role MUST be the same configured in the parameter 4010 in the GRC Box. In this example: Z_SAP_GRC_SPM_FFID.
You have to create a user (FIREFIGHTER_ID) in the target system with the corresponding roles required roles/profiles according to your requirements. In addition you must assign to the FIREFIGHTER_ID the role Z_SAP_GRC_SPM_FFID. This user should be of type: Service as per note 1702439
The following note describes an issue you'll face with this kind of users: Note 1586989 - Object Services icon not available in Firefighter ID session I'll update this document when a specific note for GRC 10 is released regarding this issue.
Access to the NWBC: http://<server>:<port>/nwbc/ or execute tx. NWBC in the GRC Box. Go to the Setup tab and:
Creating reason codes: You have to create at least one reason code to be able to use the firefighter ID later.
Synchronization Jobs: In accordance with note: 1585079 You have to execute the synchronization Jobs in order to make the FF IDs available in GRC Box for selection:
Please make sure that you have performed following configuration steps: 1. 1. Integration Scenarios are configured as explained in note 1562760 2. 2. Please make sure the Firefighter role is assigned to Firefighter IDs in the corresponding client system and that the same role has been given as parameter value for configuration parameter 4010. Configuration parameters can be configured in the transaction code SPRO => Governance, Risk & Compliance => Access Control => Maintain Configuration Settings 3. 3. Run User/Role/Profile/Auth synchronization jobs. The Link to run these jobs can be found Under transaction code SPRO => Governance, Risk & Compliance => Access Control => Synchronization Jobs.
Once you have executed the auth & repository sync job with the corresponding target connector, the FF ID will be available for selection in the GRC Box. See also Note 1668255
Once you are done with the above steps, re-run an Incremental/Full User Sync for the Firefighter IDs with the Firefighter Role to be SYNCed into the GRC box. Now re-launch the application via NWBC or Portal and then search for the Firefighter ID and this should be available in Firefighter ID list. Assign Owners:
Here you assign the Firefighter ID to the corresponding Firefighters users (one or more)
Execute tx. GRAC_SPM_LOG_SYNC and schedule the log collection periodically as per note: 1617529
Known problems with time zones: Note 1595462 - Logs not visible in the SPM Reports Note 1775432 - Transaction logs are not getting captured by GRC 10.0
E-mail configuration:
If you want the controller to receive e-mails (firefighter logon notification and firefighter session details) you have to check the following:
Make sure your Basis team has properly configured outgoing e-emails from GRC Box (Tx. SCOT) Controller notification method was set to: Email (see above) SPRO parameters: 4002 Send E-mail Immediately YES 4007 Send Log Report Execution Notification Immediately YES 4008 Send FirefightID Logon Notification YES 4009 Log Report Execution Notification YES
Controller user (FF_CONTROL) has "Comm.Method set to E-Mail in SU01 and has a valid e-mail address. WF-BATCH User must also have an e-mail address in SU01; otherwise youll get the following error in tx. SLG1:
You can change the parameter and use another user to send the e-mails.
After executing the GRAC_SPM_LOG_SYNC_UPDATE, please execute tx. SOST and check if the emails were generated (you have to access the firefighter to get the e-mails).
Despite the Firefighter ID password is changed by the application each time you start the firefighter (you can check it via change documents in the target system), Firefighter Ids need to be restricted from Logging in into SAP System directly via SAP GUI. For this purpose either we need to create and modify the SAP User Login Exit.
Please check: Note 1701047 - Is it mandatory to use trusted connection in the RFC destination for Firefighter Connector?
"Yes it is mandatory to make a trusted relationship so that communication can be established between the GRC system and the plug-in."
Note 1065048 - Firefighter Log Not sent in Email to Controller <<- for 5.3, but useful Note 1618040 - Performance fix for SPM transaction logs for large systems Note 1732938 - Firefighter incorrect language setting on ERP Production
Note 1730649 - Firefighter owner can assign ANY Firefighter ID to Firefighter User Note 1747283 - EAM: Entries in EAM logon pad not Visible for a firefighter
Well, thats all. Hope this document has helped you to successfully configure GRC EAM.