TDA2822
DUAL LOW VOLTAGE POWER AMPLIFIER
DESCRIPTION
The UTC TDA2822 is a monolithic integrated audio amplifier in a 8-Pin plastic dual in line package. It is designed for portable cassette players and radios.
SOP-8
FEATURES
*Wide operating supply voltage: Vcc=1.8V- 12V. *Low crossover distortion. *Low quiescent circuit current. *Bridge/stereo configuration.
DIP-8
ORDERING INFORMATION Order Number Normal Lead Free Plating TDA2822-S08-R TDA2822L-S08-R TDA2822-S08-T TDA2822L-S08-T TDA2822-D08-T TDA2822L-D08-T Package SOP-8 SOP-8 DIP-8 Packing Tape Reel Tube Tube
1
QW-R107-006.E
TDA2822
PIN CONFIGURATIONS
OUTPUT 1
NF 1
Vcc
INPUT 1
OUTPUT 2
INPUT 2
GND
NF 2
BLOCK DIAGRAM
VCC 2
INPUT1 NP1
7 8
+ 1 OUTPUT1
INPUT2 NP2
6 5
+ 3 OUTPUT2
4 GND
2
QW-R107-006.E
TDA2822
ABSOLUTE MAXIMUM RATINGS (Ta=25C)
PARAMETER Supply Voltage Output Peak Current SYMBOL VCC IO(peak)
RATINGS UNIT 15 V 1 A DIP-8 1.0 Power Dissipation PD W SOP-8 0.5 Operating Temperature TOPR -20~+85 C Storage Temperature TSTG -40~+150 C Note:1. Absolute maximum ratings are stress ratings only and functional device operation is not implied. The device could be damaged beyond Absolute maximum ratings. 2. The device is guaranteed to meet performance specifications within 0~70 operating temperature range and assured by design from -20~ 85
Total Harmonic Distortion Ripple Rejection Output Noise Voltage Cross Talk Input Resistance
24
2.0
100
3
QW-R107-006.E
TDA2822
TEST CIRCUIT STEREO
VCC
C3 100 F
INPUT1
R1 10k C1 100 F
7
1
C4 470 F
C6 0.1 F R3 4.7
RL
INPUT2
R2 10k C2 100 F
6 3 5
C5 470 F
C7 0.1 F R4 4.7
RL
BRIDGE
VCC
C5 100 F
INPUT1
R1 10k
7 1
C2 0.1 F R2 4.7
8
C1 10 F
RL
3
C3 0.1 F R3 4.7
5 4
C4 0.01 F
4
QW-R107-006.E
TDA2822
SCHEMATIC DIAGRAM
2 Vcc
I source
8 NF 1
7 INPUT 1
6 INPUT 2
5 NF 2
4 GND
TYPICAL CHARACTERISTICS
0 10 20 30 40
C1=C2 =100 F C1=C2 =22 F
12
16
10
30
100
300
1000
3000
FREQUENCY (Hz)
UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.
5
QW-R107-006.E