DESCRIPTION: Full port, metal seated ball valve for pig receiver by pass.

APPLICATION: Natural Gas SIZE: 8 Diameter TEMPERATURE Min/Max: 30 Deg F/200 Deg F NACE: MRO103 DESCRIPTION: Ball, Trunnion Mounted. OPERATOR: Manual. Gear operated. RATING: ANSI 600# BODY DESIGN: End Entry or welded body BOLTING MATERIAL (Body studs/nuts): ASTM A320/A320M Gr L7, ASTM A194 Gr 7 BODY MATERIAL: ASTM A350 Gr LF2 SEATS: Metal to Metal Seats SEAT RING DESIGN: Double Piston\Double Acting SEAT RING MATERIAL: 410 SS, Tungsten Carbide Coated BALL MATERIAL: 410 SS, Tungsten Carbide Coating BALL: One piece, solid ball. BORE: Full Port ENDS: ANSI 600 Flanged both ends, ASME B16.5 DIMENSIONAL STANDARD: API 6D DESIGN STANDARD: API 6D, ASME B16.34 SEATS SEALANT INJECTION: Two (2) per end connection with safety cap STEM SEALANT FITTING: Required, with safety cap STEM SEALS: Explosive decompression resistant

TESTING STANDARDS: API 6D,API 598 DOUBLE BLOCK AND BLEED: Open and closed position OR Closed position only CAVITY DRAIN PORT: 1 DBB port CAVITY DRAIN PORT MATERIAL: 1 Nipple to be 17/4 PH, Manifold valve to be 316 St/St CAVITY BLEED PORT: 1 safety plug BLEED PORT PLUG MATERIAL: 17/4 PH FIRE TESTING STANDARD: API 6FA LIFTING LUGS: Required ANTI-STATIC DEVICE: Required

OTHER REQUIREMENTS:

1. Threaded body plugs shall be 316 stainless steel 2. All seal areas to be overlaid with Inconel 625 3. Seal design: Lip seals 4. Coating system suitable for offshore environment. Final coat shall be white. Minimum Dry Film Thickness (DFT) 11 mils. Purchaser approvals required. Preparation by sandblasting to SSPS-SP 10 (near white) 5. External relief valves, if incorporated in the design, shall be constructed with austenitic stainless steel body or material of superior corrosion resistance. The set pressure of cavity relief valve must be clearly marked on the nameplate. All valves with external cavity relief shall also be fitted with a tag stating Fitted with external pressure relief valve. 6. Vendor shall submit two (2) written procedures (1. Actuator 2. Valve) outlining all tests that are to be done as part of the Factory Acceptance Testing. These procedures must be approved by Company. 7. Vendor shall submit 1. Material test records. 2. Welding inspection reports 3. Hydrostatic and pneumatic testing reports 4. Non-destructive inspection reports 5. Certificates of Calibration for

a. Chart Recorder b. Anti-Static c. Torque Testing Equipment 6. Technical manuals and performance testing documents for the actuator. 8. After testing, the valve shall be thoroughly drained. Lube fittings shall be installed and a light lubricant injected through all ports in the presence of the inspector.

Factory Acceptance Testing: The following shall be witnessed by a company representative at the manufacturers facility prior to shipping the valve: 1. Hydrostatic Shell test (API 6D) 2. Hydrostatic seat tests (API 598) 3. Low pressure gas test (API 598) 4. High pressure gas test (API 598) 5. Torque tests (In accordance to API 6D requirements) 6. Anti Static testing (API 6D)