Anda di halaman 1dari 4

Special Order Products

RY-PA-10/A
10 Relay Adaptor For use with the LEF, LDF and NDR Systems - INSTRUCTIONS The RY-PA-10/A is a multiple output relay adaptor, featuring 10 individually controlled relays with both Normally Open and Normally Closed contacts. All relay contacts are rated at 240V AC, 300mA or 24V DC, 1A. The RY-PA-10/A is ideal for systems providing selective door release, CCTV camera call-up, or a combination of both.

RY-PA-10/A Terminal Definition:


RY-PA-10/A Front View (Output to devices)

NO1: Normally Open Contact, Relay #1 NC1: Normally Closed Contact, Relay #1 CM1: Common Contact, Relay #1 NO2: Normally Open Contact, Relay #2 NC2: Normally Closed Contact, Relay #2 CM2: Common Contact, Relay #2 NO3: Normally Open Contact, Relay #3 NC3: Normally Closed Contact, Relay #3 CM3: Common Contact, Relay #3

NO4: Normally Open Contact, Relay #4 NC4: Normally Closed Contact, Relay #4 CM4: Common Contact, Relay #4 NO5: Normally Open Contact, Relay #5 NC5: Normally Closed Contact, Relay #5 CM5: Common Contact, Relay #5 NO6: Normally Open Contact, Relay #6 NC6: Normally Closed Contact, Relay #6 CM6: Common Contact, Relay #6

NO7: Normally Open Contact, Relay #7 NC7: Normally Closed Contact, Relay #7 CM7: Common Contact, Relay #7 NO8: Normally Open Contact, Relay #8 NC8: Normally Closed Contact, Relay #8 CM8: Common Contact, Relay #8 NO9: Normally Open Contact, Relay #9 NC9: Normally Closed Contact, Relay #9 CM9: Common Contact, Relay #9 NO10: Normally Open Contact, Relay #10 NC10: Normally Closed Contact, Relay #10 CM10: Common Contact, Relay #10

RY-PA-10/A Back View (Input from intercom)

1+: Positive 12V DC Input, Relay #1 1-: Negative, Relay #1 2+: Positive 12V DC Input, Relay #2 2-: Negative, Relay #2 3+: Positive 12V DC Input, Relay #3 3-: Negative, Relay #3 4+: Positive 12V DC Input, Relay #4 4-: Negative, Relay #4 5+: Positive 12V DC Input, Relay #5 5-: Negative, Relay #5

6+: Positive 12V DC Input, Relay #6 6-: Negative, Relay #6 7+: Positive 12V DC Input, Relay #7 7-: Negative, Relay #7 8+: Positive 12V DC Input, Relay #8 8-: Negative, Relay #8 9+: Positive 12V DC Input, Relay #9 9-: Negative, Relay #9 10+: Positive 12V DC Input, Relay #10 10-: Negative, Relay #10

Pg. 1

WIRING DIAGRAM:
LEF-10 1 2 3 ~ 10 E R Y + -

RY-PA-10/A USED FOR SELECTIVE DOOR RELEASE


LS-NVP/B Red LE-D 1 LE-DA 1 E

Blk

PS-1225UL

+ -

Grn
RY-PA-10/A

CM1 NO1 CM2 NO2 CM3 NO3 K1 K2 K3 ~ K10 12345~ 101+ 2+ 3+ 4+ 5+ ~ 10+

To Door Release #1 To Door Release #2 To Door Release #3

Notes: 1. Tie all the #+'s together of the relays that will be used for door release activation. 2. The "L" terminal provides +12V DC when door release button is pressed. 3. Normally Open contacts will be closed as long as the door release button is pressed. 4. Only wiring concerning door release is shown here. For complete system information, refer to the system installation manual.

Pg. 2

WIRING DIAGRAM:

RY-PA-10/A USED FOR CCTV CAMERA CALL-UP

NDR-20A 1 2 3 ~ 20
PS-2420UL

NE-NVP Red NA-NE Red Blk


Leave green jumper intact

NE-DA 1

E + RY-PA-10/A

Grn Grn

Blk Grn

2 Blk Wht

+ -

CM1 NO1 CM2 NO2 CM3 NO3 1 2 3 ~ 20 L H 12345~ 101+ 2+ 3+ 4+ 5+ ~ 10+

Maintained Closure for Stn. #1 Maintained Closure for Stn. #2 Maintained Closure for Stn. #3

External Terminal Block

Notes: 1. Tie all the #+'s together of the relays that will be used for CCTV camera call-up. 2. The "H" terminal from the NDR master provides +12V DC when a sub station is selected. 3. Normally Open contacts will be closed as long as master has sub station selected. 4. Only wiring concerning door release is shown here. For complete system information refer to the system installation manual.

Pg. 3

WIRING DIAGRAM: RY-PA-10/A USED FOR BOTH SELECTIVE DOOR RELEASE AND CCTV CAMERA CALL-UP
NDR-20A 1 2 3 ~ 20
PS-2420UL

NE-NVP Red NA-NE Red Blk


Leave green jumper intact

NE-DA 1

E + RY-PA-10/A

Grn Grn

Blk Grn

2 Blk Wht

+ -

External Terminal Block

1 2 3 ~ 20 L

CM1 NO1 CM2 NO2 CM3 NO3 CM4 NO4 CM5 NO5 CM6 NO6 123456~ 101+ 3+ 5+ 2+ 4+ 6+ ~ 10+

Door Release for Stn. #1 Maintained Closure for Stn. #1 Door Release for Stn. #2 Maintained Closure for Stn. #2 Door Release for Stn. #3 Maintained Closure for Stn. #3

Notes: 1. Use diodes of a value between 1N4001 ~ 1N4007 or equivalent. 2. Tie all the #+'s together of the relays that will be used for CCTV camera call-up. 3.Tie all the #+'s together of the relays that will be used for door release activation. 4. Normally Open contacts tied to the "H" terminal will be closed as long as master has sub station selected. 5. Normally Open contacts tied to the "L" terminal on the separate terminal block will be closed as long as the door release button is pressed. 6. Only wiring concerning relay connection is shown here. For complete system information refer to the system installation manual.

Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071

TOLL FREE TECHNICAL SUPPORT: (800) 692-0200 TOLL FREE FAX LINE: (800) 832-3765 E-MAIL: tech-serv@aiphone.com

Pg. 4 RY-PA-10/A Instr. 1103bkjs