SCUBA
In environments where dust, dirt and moisture abound, SCUBA provides highly functional lighting.
The individual and the machine The luminaire is the vital link to safety and efficiency
In his bakery, a skilled master baker makes fancy plaited loaves by hand. This demands excellent hygiene and a high
level of concentration. The luminaire makes its own contribution: even fine flour dust poses no problem whatsoever
S C U B A AT W O R K
High-tech in absolutely every respect: a packaging plant for pet food that is operated and controlled by individuals imposes exacting demands in terms of visual tasks. It is a challenge, for instance, to
make adjustments on displays and keep track of rapid movements of plant machinery. SCUBAs outstanding lighting technology and high light output ratios effortlessly master these difficult conditions.
A luminaire that can put up with a lot and still deliver extra performance
Perfect visual conditions in any weather Articulated heavy goods lorries, heavily loaded trailers, fragile loads the canopy roof may provide protection against direct rain, but many hidden dangers nevertheless lurk even in this covered outdoor area. Thanks to its excellent lighting technolo gy and ruggedness, SCUBA protects both itself and em ployees.
Coping with a tough day-to-day work routine but still looking good A luminaire in a carwash is con stantly exposed to a challenging combination of moisture and detergents at busy times. With its rugged, highly protective housing, SCUBA can even meet this challenge.
S C U B A A P P L I C AT I O N A R E A S
Long service life, even under harsh conditions Things can often get quite hot in utility and supply rooms, both literally and figuratively. Correct action must be taken quickly when malfunctions occur. This task is made easier by good lighting that works properly.
Optimum protection for any contingency SCUBA even has the answer to chemical vapours combined with high air humidity: a special Chemo diffuser that combines the chemical resistance of visually attractive PMMA with the elasticity and strength of polycarbonate.
DESIGN
SCUBA
The challenge was to cope simultaneously with both functional requirements and aesthetic aspects. The modern essence of the style of these luminaires has completely realigned the traditional relationship between form and function, between lighting quality and
design. These are lighting modules for impersonal environments where light redefines a space and makes it more pleasant without neglecting the necessary technical priorities.
www.zumtobel.com/scuba
SCUBA DESIGN
Its clever mix of features makes SCUBA the new innovation leader in moistureproof luminaires. Not only are installation, maintenance and cleaning childs play SCUBA always provides perfect lighting conditions, even under the most demanding environ-
mental conditions, and also boasts reliable protection against external influences and chemicals.
Versatility, handling and quality: SCUBA has something new to offer in every area
In situations where conventional luminaires are ready to give up, this new moistureproof lumi naire really comes into its own. Whether confronted with dirt, dust, moisture or chemical atmospheres (IP65: dusttight, jetproof) SCUBA ensures durable functionality and respectable lighting quality in any environment. The name itself says it all. SCUBA stands for:
S C U B A Shockproof Chemically resistant UV-stable Benefit-orientated Application-orientated
The best diffuser for every application A choice of diffusers made of unbreakable polycarbonate or chemically and UV resistant PMMA is available. This visually attractive product line is rounded out by an extra tough CHEMO diffuser. A special expansion joint compensates for the differ ent coefficients of expansion of various combinations of materi als, thereby ensuring IP65 pro tection for all models.
Safely locked up This luminaire simply clicks shut. A builtin control mecha nism gives audible and visible indication of quick closure that ensures IP65 protection.
Place screwdriver in clip and open by exerting gentle inward pressure.
In addition, closefitting, smooth catches make cleaning easier and provide protection against vandals. A screwdriver is all that is needed to open the luminaire. A chemically resistant plastic catch is available for special applications.
S C U B A I N N O V AT I O N
15 slope angle to shed dust and water All exposed visible surfaces of the luminaire have an angle of 15 or more. Together with its smooth exterior, this prevents accumula tion of dust and moisture and also makes cleaning easier. SCUBA therefore meets the recommenda tions of the German Association for Electrical, Electronic & Infor mation Technologies (VDE), and International Food Standards (IFS) and British Retail Consortium (BRC) specifications.
15
Optimum visual comfort Prism structures especially opti mised for T16 light sources ensure excellent technical light ing features with high light out put ratios for a moistureproof luminaire. Reduced light at shallow angles results in a minimal Unified Glare Rating (UGR) value and therefore improved glare reduc tion. The luminaires wideangle batwing pattern ensures uniform illuminance distribution.
One luminaire, four installation options Simplicity provides the basis for flexibility
Directly installed on the ceiling or wall An individual SCUBA luminaire can be quickly installed on the ceiling or wall using a ceiling bracket and Zumtobels tried andtested CLIX mechanism. The spacings and ceiling brack ets are identical to those of the FZ luminaire, thus making changeover from FZ luminaires to the innovative SCUBA lumi naire economical.
Suspended from the ceiling A chain and a special triangle are used to suspend individual luminaires from the ceiling. Both these items can be ordered as accessories.
S C U B A I N S TA L L AT I O N O P T I O N S
11
Installed on the ceiling using trunking Proven ZX trunking is recom mended for installation as a con tinuous row system (please order additional sealing grommets as accessories). ZX trunking has one major advantage through wiring can be concealed inside the section of the trunking unit.
Suspended using trunking If there is a requirement to combine throughwiring (in the trunking) and suspension, ZX trunking is the ideal link (please order additional sealing grommets as accessories). The trunking unit is suspended using a chain, and luminaires are installed on the trunking by means of ceiling brackets (CLIX mechanism).
The ultimate moisture-proof luminaire The big difference is the many small details
1
Safety 1
Rugged basic housing Glass fibrereinforced polyester 15 slope angle All exposed visible surfaces have an angle of 15 or more.
Compatibility 5 Spacings
The slightly longer SCUBA luminaire has the same fixing spacings as an FZ luminaire; the installation clearance of the 58 W and 36 W versions is the same. This saves time and simplifies installation on the ceiling, wall or ZX trunking (CLIX mechanism).
Innovative sealing rim with water drip Dripping water cannot penetrate inside the luminaire.
Three diffuser options as standard Polycarbonate: unbreakable, impact resistant PMMA: impact resistant, chemically resistant, UV resistant CHEMO: extra chemically resistant, UV resistant, unbreakable
Quick to install, close-fitting safety catches No risk of losing catches, reduced risk of injury, audible and visible indication of sealing guarantees IP65 protection, vandalproof.
Economic efficiency
The optimised prism structures support lighting technology that provides high light output ratios. Excellent maintenance values extend the maintenance intervals. Available on request: heavy-duty electronic ballast for increased service life at higher ambient temperatures which can withstand moisture and vibration.
Bracket (FZ-compatible)
Exceptionally neat and tidy When it comes to wiring and installation, less is more
Less effort and fewer parts mean greater convenience and better safety during assembly and installation. The SCUBA continuous row system can
be throughwired conveniently. If trunking is installed, through wiring is led inside the trunking unit. A double insulated cable can be used for this purpose. In
case of installation without trunking, throughwiring is led in the basic housing: in lumi naires with lowloss ballasts and luminaires with electronic
ballasts and PMMA diffusers, using an extra heatresistant, halogenfree kit for throughwir ing (DV kit); in luminaires with electronic ballasts and polycar
Throughwiring for luminaires with lowloss ballasts and luminaires with electronic ballasts with PMMA diffusers:
Insert connecting cable through cable entry and secure using supplied grommet or customer-supplied cable gland.
Reflector holder is also the spring clip for the through-wiring kit.
Cable grips are used to fix the through-wiring kit to the basic housing.
Unpack luminaire, open and remove bag containing all installation accessories from ceiling brackets and catches through to sealing grommets.
First fit the safety catches to the luminaires basic housing. It is then impossible to lose them.
Then fit the brackets on the ceiling. The existing drilled holes and fixings can be used if you are replacing FZ luminaires.
Then snap basic housing into brackets using tried-and-tested CLIX mechanism.
S C U B A I N S TA L L AT I O N
1
bonate or CHEMO diffusers, using an NYM cable. Looping through is also permitted, the SCUBA luminaire can be wired in/out at one end.
Preparation for wiring For throughwiring, use a drill to drill out the second cable entry which is left closed when the unit leaves the factory. Cable entry openings are marked on the ends and the top of the basic housing.
Throughwiring for luminaires with electronic ballasts with polycarbonate and CHEMO diffusers
Cable grips (accessories) are used to fix the NYM through-wiring to the basic housing.
The reflector holder is also the spring clip for the NYM cable.
To prepare for electrical connection, hinge the reflector, insert cables through the sealing grommet and attach to the plug-in terminal blocks.
Then detach the reflector and click it into the reflector holder.
Finally, use the catches already fitted on the basic housing to fix the diffuser. There is an audible indication of luminaire closure (CLIX mechanism) that guarantees IP65 protection.
The specialist for harsh conditions Standard product range includes three diffusers
The effects of chemicals on materials No material can withstand the effects of every chemical. The effects of chemicals vary widely and take up entire volumes of chemical resistance charts. The accompanying tables on this page and overleaf therefore only provide a brief overview of fre quently encountered applica tions and chemical effects. The information given is valid under the following conditions: The chemical substance listed in the table is an element and not part of a chemical compound. The ambient temperature is 22 C.
What needs to be taken into account? A luminaire consists of several components that have various functions and are therefore made of different materials. The precise chemical compo sition of the substances to which a luminaire is exposed must be clarified with the rele vant operator. In addition, allowance must be made for the degree of saturation of the chemical substances. The ambient temperature also has an effect. Chemical reac tions take place at higher or lower temperatures, depend ing on the nature and compo sition of the substances.
Polymethylmetacrylate PMMA 100 % UV resistant good chemical resistance clear impact resistant CHEMO extremely UV resistant, comparable to PMMA substantial resistance to a large number of chemicals impact resistance similar to PC
highly recommended
suitable
unsuitable
60
80
100
120
S C U B A E F F E C T S O N M AT E R I A L S
1
resistant
not resistant
UV resistance Impact resistance Resistance to ageing Siliconefree Halogenfree *** Foodgrade certification (15 angle) Glowwire test Heat resistance of luminaire plastics Flammability acc. to UL94 (ISO 60695) UV transmittance * Limited UV stability of PC
SCUBA with PC diffuser + ** PC diffuser 10 Nm Good * Yes Luminaire yes Internal wiring no Yes Housing at 850 C Diffuser 850 C Housing at 160 C, Diffuser 125 C V2 89 %
SCUBA with PMMA diffuser ++ PMMA diffuser 0.2 Nm Excellent Yes Luminaire yes Internal wiring no Yes Housing at 850 C Diffuser 650 C Housing at 160 C Diffuser 95 C * HB 91 %
SCUBA with CHEMO diffuser ++ CHEMO diffuser 4 Nm Excellent Yes Luminaire yes Internal wiring no Yes Housing at 850 C Diffuser 650 C Housing at 160 C Diffuser 122 C HB 89 %
Basic polyester housing ++ 0.35 Nm Excellent Yes Yes Internal wiring no Yes Housing 850 C Housing 160 C HB
** UV stabilised
SCUBA and Humanergy Balance Lighting solutions for a balance between the environment, energy and the individual
SCUBA provides evidence: It is possible to balance lighting quality and energy efficiency, even under harsh conditions.
Zumtobel defines balanced lighting solutions as those which provide ultimate lighting quality and energy efficiency. Lighting solutions that meet peoples physical and psychological needs and at the same time help to cut energy consumption. The Ergonomic Lighting Indica tor (ELI) assesses the quality components of a lighting solu tion.
Ambient lighting is the first step. A lighting solution using SCUBA meets specifications in the standards, visual performance and comfort are ensured. Investing in higher quality com ponents boosts quality but also increases investment costs. Nevertheless, the initial extra investment in electronic ballasts and T16 light sources pays for itself, thanks to savings in ener gy consumption.
Installing these innovative lumi naires has a positive impact on LENI, the Lighting Energy Numeric Indicator. The typical SCUBA lighting solution actually calculated and documented on the following page cuts energy consumption per annum and per square metre by more than 33 % from 106.26 to 71.28 kWh/m2a.
0 71.28 106.26 - 34.98 kWh/m2a = kilowatt hours per square metre and per year
1
Lighting solution 1: The better the technical 42 off SCUBA 2/58 W, low-loss characteristics of the ballast, T26 light sources luminaire, the greater the increase in energy efficiency and lighting quality.
Room situation: Factory bay Flexibly arranged furnishings Floor space 16 x 12 m, i.e. 192 m2 Height of room 5 m Type of lighting: Direct lighting Lighting concept: Roomrelated lighting Basic parameters: Fiveday week Twoshift working, each shift 8 hours Luminaires installed at a height of 4 m Required illuminance 500 lx Daylightbased control in case of elec tronic ballast mode
Lighting solution 2: 42 off SCUBA 2/58 W, electronic ballast, T26 light sources
Lighting solution 3: 35 off SCUBA 2/49 W, electronic ballast, T16 light sources
The lighting solution with 6 x 7 SCUBA luminaires ensures a high standard of safety.
This solution, which also uses 6 x 7 SCUBA luminaires, benefits from the features of an electronic ballast: Reduced energy consumption Longer lamp service life Flickerfree starting No strobing
The lighting solution with 5 x 7 SCUBA luminaires adds the advantages of the T16 light sources to those of the elec tronic ballast: A higher light output ratio and improved luminous efficiency make it possible to reduce the number of luminaires, thereby cutting energy consumption
A Visual performance: SCUBA meets all requirements regarding safety and visual per formance in the workplace. Its balanced light distribution ensures pleasantly uniform illuminance. B Appearance: With its pareddown luminaire unit, SCUBA blends unobtru sively and harmoniously into the interior design. Its soft, rounded lines reveal its func
tional strengths: the luminaire is resistant to soiling and easy to clean. C Visual comfort: Its optimised prism structure facilitates the precise direction of light and efficient glare control. The special shape of the prisms has been de signed to ensure homogeneous room illumination (batwing effect).
D Emotion: Its design styling, which is new for moistureproof luminaires, adds a pleasant atmosphere, even in impersonal rooms. E Individuality: A SCUBA lighting solution can be selectively adapted to cater for its main use thanks to three different standard diffusers made of polycarbonate or PMMA and a CHEMO diffuser.
still further. Variable fitting options for lamps of the same length allow better adjustment to suit various visual tasks.
ELI quality: 11
A
ELI quality: 12
A
ELI quality: 12
A
The LENItoELI ratio was used to obtain an overall evaluation for test purposes: the smaller this ratio, the more balanced the lighting solution is.
180 0
180 0
180180 0 0
180
180 180
180
180
LENI/ELI = 9.66
LENI/ELI = 7.13
LENI/ELI = 5.94
For round-the-clock jobs under adverse conditions SCUBA with PC Industry electronic ballast
The PC Industry product range was specially designed for use in harsh industrial environments such as production lines or manufacturing plants that oper ate continuously. These elec tronic ballasts have proven their
absolute reliability in operating T26 fluorescent lamps (36 W and 58 W) and T16 lamps (49 W, 54 W and 80 W). In addition, all models ensure a long service life, even under tough environ mental conditions. Available on request: SCUBA moisture-proof luminaire fitted with PC Industry ballast.
S C U B A W I T H H E A V Y- D U T Y E L E C T R O N I C B A L L A S T
21
Outstanding PC Industry characteristics Service life of 100,000 hours at a maximum ambient tem perature of +60 C (on ballast) Service life of 50,000 hours at a maximum ambient tempera ture of +70 C (on ballast) Long lamp service life thanks to gentle warm start Automatic restart after lamp change Suitable for high mains voltage peaks up to 4 kV Constant light output inde pendent of fluctuations in mains voltage Suitable for use even at low temperatures (down to 30 C on ballast) Switchoff of defective lamps Radio interference suppres sion up to 1 GHz according to EN 55015 and RN 55022
Comparison of service life of a PC Industry ballast compared with a standard electronic ballast using example of SCUBA luminaire:
Reliability SCUBA + standard electronic ballast SCUBA with PC Industry: same service life at higher temperature SCUBA with PC Industry: double the service life at same temperature
90%
95%
10.000
20.000
30.000
40.000
50.000
60.000
70.000
80.000
90.000 100.000
Standard electr. ballast 1/58 W, at 38 C max. 2/58 W, at 32 C max. 1/36 W, at 47 C max. 2/36 W, at 35 C max.
Measured values refer to ambient temperature without throughwiring. Subtract 7 C in case of throughwiring.
Economically efficient in everyday use Reduced maintenance expenditure, high energy efficiency
Longer intervals between required maintenance work. Lower wattages are sufficient to achieve required illuminance levels. Number of luminaires can be reduced, taking into account uniform light distribution.
SS = very clean S = clean (cleanrooms, data centres, hospitals) N = normal (schools, assembly bays, warehouses, laboratories) V = dirty (chemical plants, woodworking, welding shops)
Concrete example of a luminaire: direct system, T16 light source, electronic ballast Room: normal dirty, medium sized, room index 2.5 Maintenance interval: 3 years, 2,500 hours of operation p.a. (single shift, 6day week)
Luminaire Lamp lumens maintenance factor: Lamp survival factor: Room maintenance factor: Luminaire maintenance factor: Maintenance factor
The higher maintenance factor for SCUBA results in an illuminance level that is up to 15% higher compared with the IP20 system. This allows a maintenance interval of 3 years, or extra scope when dimensioning the installation from new (e.g. choice of wattages). In accordance with CIE Publication 97, Maintenance of indoor electric lighting systems, 2005 edition
International Food Standards (IFS) and the British Retail Consortium (BRC) have laid down relevant standards for the food processing industry. These are needed primarily by international chains such as McDonalds in order to ensure minimum standards and high light room for possible improve ments at the time of annual inspections.
IFS and BRC requirements placed on lighting installations in the food processing industry: No use of glass Covered light source (enclosed luminaire) Shatterproofness (PC diffuser)
Optional enhancements: Shatterproof and chemically resistant if special cleaning agent is used (CHEMO diffuser) A light source with foil sheet ing reduces the risk of glass breakage when relamping
S C U B A S TA N D A R D S A N D N O R M S
2
Cool spot optimizer for more efficient operation of T16 light sources at constantly low temperatures
This protective metal sleeve was specially developed to increase the durability of T16 light sources in environments where temperatures are constantly low. The cool spot optimizer simply clips onto the lamp to ensure more light, lower energy consumption and optimised luminaire usage.
Calculate flux A program for calculating luminous flux output depending on lamp and ambient temperature
If the luminous flux documented in the figures is taken into account during planning or by the design tool, the number of luminaires and lamps can be deliberately optimised.
Example of calculation using Calculate flux: T16 lamp, 49 W/827840, single lamp, enclosed luminaire (SCUBA) Relative luminous flux of lamp [%]
110 100 90 80 70 60 50 40 30 20 10 0 -50 -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20
Curious? Then visit our homepage. Get full details of products and design programs at www.zumtobel.com
Standard
Measurements make the difference clear: whereas luminous flux drops sharply at low and high temperatures in the case of a conventional T16 fluorescent lamp, the new amalgam lamps offer a constantly high luminous flux. Based on a batten luminaire with open light distribution.
60 50 40 30 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Amalgam lamp
SCUBA reveals its true poten tial when combined with ONLITE emergency lighting and LUXMATE lighting manage ment. The result is an integral
lighting solution that saves energy whilst ensuring more convenient operation. Opting for LUXMATE lighting management gives you the
peace of mind of triedand tested Zumtobel control solu tions. Like almost all Zumtobel luminaires, SCUBA is also avail able as an ONLITE emergency
luminaire. Intelligent ONLITE emergency lighting systems take on full responsibility, in the background, for emergency lighting.
Luminaire group 2
SCUBA NT1/NT3
ECOSIGN NT1/NT3
Characteristics Daylight-based control of two groups of luminaires Presence detector can be fitted Open DALI Standard Option of manual dimming
DALI
230 V AC
Characteristics Luminaires with separate battery supply Almost every Zumtobel luminaire can be ordered as a ready-made emergency luminaire; no need to manually fit luminaires with emergency lighting modules Required functional and annual system tests are performed automatically
Benefits A DALI link to the central monitoring unit allows fully automatic monitoring and logging of test results Extremely straightforward installation (no battery compartment, no E30) No separate, architecturally inappropriate emergency luminaires Minimal operating costs Highest level of intrinsic safety
Example of design - laboratory: Two groups of luminaires (fewer than 100 luminaires) One window frontage Requirement specification: Straightforward installation and commissioning Reduced energy costs Compliance with statutory regulations
Ideal for small to mediumsized buildings: LUXMATE Basic lighting management and ONLITE local emergency lighting
EPS 360 EPS 360 EPS 360
+ +
+ +
+ +
S C U B A W I T H O N L I T E A N D L U X M AT E
2
DALI
SCUBA NSI
ECOSIGN NSI
LMDALI (S)
LUXMATE bus
EPS 360
EPS 360
EPS 360
DALI
LMDALI (S)
+ +
LRA 1500 Graphical User Interface LMWGO Benefits Straightforward installation Energy-saving Integrated into building management system Characteristics Group-battery installation Emergency lighting is fully integrated into general lighting Individual control and configuring of all luminaires Fully automatic monitoring and logging of test results
+ +
+ +
Characteristics Intelligent, daylight-based control of all groups of luminaires and blinds by using external daylight sensor and automation computer Time management and management of burning hours Display user interfaces and alarm management Central operation of hardware and software Integration into building management system via BMS
Benefits Reduced effort on cabling Improved safety thanks to splitting into several autonomous systems No separate, architecturally inappropriate emergency luminaires Minimal operating costs thanks to central monitoring
Example of design - Industrial bay: - Standard unified system for entire building - Several glazed frontages Requirement specification: - Convenient operation and monitoring - Reduced operating costs - Visual display of emergency lighting installation
Ideal for medium-sized and large buildings: LUXMATE Professional lighting management and ONLITE central emergency lighting
SCUBA
26
www.zumtobel.com/scuba
SCUBA
2
SCUBA T16 moisture-proof diffuser luminaire, 1-lamp Moisture-proof diffuser luminaire Housing made of halogen-free glassfibre reinforced polyester Single-piece injection-moulded diffusers: PC: polycarbonate with internal prism structure PMMA: UV-resistant PMMA with internal prism structure CHEMO: CHEMO material with internal prism structure CHEMO diffuser: resistant to chemicals and also high impact resistance With electronic ballast and PC or CHEMO cover: use standard single CHEMO PMMA PC cables (NYM) for through-wiring or 850 C 650 C 850 C T16 alternatively IN-OUT wiring at one end With low-loss or electronic ballast and PM cover: use only heat-resistant single cables (see accessories) for through-wiring or alternatively IN-OUT wiring at one end Reflector made of galvanised sheet steel, painted in white SCUBA is supplied with V2A catches (plastic catches resistant to chemicals are available on request) A function earth has to be provided for protection class II with dimmable electronic ballast Installed on ceiling, wall or trunking using standard V2A spring clips Trunking installation using ZX2 (see accessories)
msUc
Cat. no. 1/28 W T16 1/35 W T16 1/49 W T16 1/54 W T16 1/80 W T16 1/28 W T16 1/35 W T16 1/49 W T16 1/54 W T16 1/80 W T16 1/28 W T16 1/35 W T16 1/49 W T16 1/54 W T16 1/80 W T16 Please note: when using PC diffusers, do not use moderately to strongly alkaline or acidic substances, solvents or cleaning agents which have a corrosive effect on plastics (PC). High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models.
L/W/H 1294/110/113 1594/110/113 1594/110/113 1294/110/113 1594/110/113 1294/110/113 1594/110/113 1594/110/113 1294/110/113 1594/110/113 1294/110/113 1594/110/113 1594/110/113 1294/110/113 1594/110/113
kg 1.9 2.3 2.3 1.9 2.3 1.9 2.3 2.3 1.9 1.9 1.9 2.3 2.3 1.9 2.3
Order no. 42 174 375 42 174 384 42 174 385 42 174 386 42 174 387 42 174 374 42 174 377 42 174 378 42 174 379 42 174 380 42 174 376 42 174 391 42 174 392 42 174 393 42 174 394
D1
D E2
D2 32
32 110
113
SCUBA
28
SCUBA T16 moisture-proof diffuser luminaire, 2-lamp Housing made of halogen-free glassfibre reinforced polyester Single-piece injection-moulded diffusers: PC: polycarbonate with internal prism structure PMMA: UV-resistant PMMA with internal prism structure CHEMO: CHEMO material with internal prism structure CHEMO diffuser: resistant to chemicals and also high impact resistance With electronic ballast and PC or CHEMO cover: use standard single cables (NYM) for through-wiring or CHEMO PMMA PC alternatively IN-OUT wiring at one end 850 C 650 C 850 C T16 With low-loss or electronic ballast and PM cover: use only heat-resistant single cables (see accessories) for through-wiring or alternatively IN-OUT wiring at one end Reflector made of galvanised sheet steel, painted in white SCUBA is supplied with V2A catches (plastic catches resistant to chemicals are available on request) A function earth has to be provided for protection class II with dimmable electronic ballast Installed on ceiling, wall or trunking using standard V2A spring clips Trunking installation using ZX2 (see accessories)
msUc
Cat. no. 2/28 W T16 2/35 W T16 2/49 W T16 2/28 W T16 2/35 W T16 2/49 W T16 2/28 W T16 2/35 W T16 2/49 W T16 Please note: when using PC diffusers, do not use moderately to strongly alkaline or acidic substances, solvents or cleaning agents which have a corrosive effect on plastics (PC). High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models.
L/W/H 1294/165/125 1594/165/125 1594/165/125 1294/165/125 1594/165/125 1594/165/125 1294/165/125 1594/165/125 1594/165/125
Order no. 42 174 388 42 174 389 42 174 390 42 174 381 42 174 382 42 174 383 42 174 395 42 174 396 42 174 397
D1
D2
70 165
125
32
SCUBA
2
SCUBA T26 moisture-proof diffuser luminaire, 1-lamp Moisture-proof diffuser luminaire Housing made of halogen-free glassfibre reinforced polyester Single-piece injection-moulded diffusers: PC: polycarbonate with internal prism structure PMMA: UV-resistant PMMA with internal prism structure CHEMO: CHEMO material with internal prism structure CHEMO diffuser: resistant to chemicals and also high impact resistance With electronic ballast and PC or CHEMO cover: use standard single cables (NYM) for through-wiring or CHEMO PMMA PC 850 C 650 C 850 C T26 alternatively IN-OUT wiring at one end With low-loss or electronic ballast and PM cover: use only heat-resistant single cables (see accessories) for through-wiring or alternatively IN-OUT wiring at one end Reflector made of galvanised sheet steel, painted in white SCUBA is supplied with V2A catches (plastic catches resistant to chemicals are available on request) A function earth has to be provided for protection class II with dimmable electronic ballast Installed on ceiling, wall or trunking using standard V2A spring clips. Trunking installation using ZX2 (see accessories) High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models Dimmable BASIC luminaires are fitted with a DSI-controllable electronic ballast
Cat. no.
L/W/H
kg 1.2 1.2 2.2 2.2 2.2 2.9 2.9 2.9 1.2 1.2 1.9 1.9 1.9 2.5 2.5 2.5 1.2 1.2 2.2 2.2 2.2 2.9 2.9 2.9 0.9 1.9 2.6 2.5 3.2 0.9 1.9 2.6 2.5 3.2
Order no. 32 161 423 32 161 426 32 161 427 32 159 732 32 161 424 32 161 428 32 159 735 32 161 425 32 161 403 32 161 406 32 161 407 32 159 730 32 161 404 32 161 408 32 159 733 32 161 405 32 161 413 32 161 416 32 161 417 32 159 731 32 161 414 32 161 418 32 159 734 32 161 415 electronic 42 174 406 42 174 407 42 174 871 42 174 408 42 174 870 electronic 42 174 398 42 174 400 42 174 869 42 174 402 42 174 868
Order no.
Luminaires with CH diffuser with low-loss ballast 1/18 W T26 lpf cm 684/110/113 1/18 W T26 hpf cm 684/110/113 1/36 W T26 hpf cm 1294/110/113 1/36 W T26 cap. cm 1294/110/113 1/36 W T26 lpf cm 1294/110/113 1/58 W T26 hpf cm 1594/110/113 1/58 W T26 cap. cm 1594/110/113 1/58 W T26 lpf cm 1594/110/113 Luminaires with PC diffuser with low-loss ballast 1/18 W T26 lpf cm 684/110/113 1/18 W T26 hpf cm 684/110/113 1/36 W T26 hpf cm 1294/110/113 1/36 W T26 cap. cm 1294/110/113 1/36 W T26 lpf cm 1294/110/113 1/58 W T26 hpf cm 1594/110/113 1/58 W T26 cap. cm 1594/110/113 1/58 W T26 lpf cm 1594/110/113 Luminaires with PM diffuser with low-loss ballast 1/18 W T26 lpf cm 684/110/113 1/18 W T26 hpf cm 684/110/113 1/36 W T26 hpf cm 1294/110/113 1/36 W T26 cap. cm 1294/110/113 1/36 W T26 lpf cm 1294/110/113 1/58 W T26 hpf cm 1594/110/113 1/58 W T26 cap. cm 1594/110/113 1/58 W T26 lpf cm 1594/110/113 Luminaires with PM diffuser with electr. ballast 1/18 W T26 cUm 684/110/113 1/36 W T26 cUm 1294/110/113
1/36 W T26 NF1 Separate battery supply 1294/110/113 1/58 W T26 cUm 1594/110/113 1/58 W T26 NF1 Separate battery supply 1594/110/113
dimmable Basic 42 174 409 42 174 410 42 174 411 dimmable Basic 42 174 399 42 174 401 42 174 403
Luminaires with PC diffuser with electr. ballast 1/18 W T26 cUm 684/110/113 1/36 W T26 cUm 1294/110/113
1/36 W T26 NF1 Separate battery supply 1294/110/113 1/58 W T26 cUm 1594/110/113 1/58 W T26 NF1 Separate battery supply 1594/110/113
Luminaires with PM diffuser with electr. ballast, protection class II electronic 1/36 W T26 cUm 1294/110/113 1.9 42 174 412 1/58 W T26 wcm 1594/110/113 2.5 42 174 413 Luminaires with PC diffuser with electr. ballast, protection class II electronic 1/36 W T26 wcm 1294/110/113 1.9 42 174 404 1/58 W T26 wcm 1594/110/113 2.5 42 174 405 Luminaires with CH diffuser with electronic ballast 1/18 W T26 cUm 684/110/113 1/36 W T26 cUm 1294/110/113 1/58 W T26 cUm 1594/110/113
0.9 1.9 2.5 electronic 42 174 414 42 174 415 42 174 416 dimmable Basic 42 174 417 42 174 418 42 174 419
Luminaires with CH diffuser with electr. ballast, protection class II electronic 1/36 W T26 cUm 1294/110/113 1.9 42 174 420 1/58 W T26 wcm 1594/110/113 2.5 42 174 421
Please note: when using PC diffusers, do not use moderately to strongly alkaline or acidic substances, solvents or cleaning agents which have a corrosive effect on plastics (PC). High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models.
D1 D E2 D2 32 58 W L = 1594 D = 900 D1 = 347 D2 = 696 E1 = 184 E2 = 216
32 110
113
SCUBA
0
SCUBA T26 moisture-proof diffuser luminaire, 2-lamp Moisture-proof diffuser luminaire Housing made of halogen-free glassfibre reinforced polyester Single-piece injection-moulded diffusers: PC: polycarbonate with internal prism structure PMMA: UV-resistant PMMA with internal prism structure CHEMO: CHEMO material with internal prism structure CHEMO diffuser: resistant to chemicals and also high impact resistance With electronic ballast and PC or CHEMO cover: use standard single CHEMO PMMA PC cables (NYM) for through-wiring or 850 C 650 C 850 C T26 alternatively IN-OUT wiring at one end With low-loss or electronic ballast and PM cover: use only heat-resistant single cables (see accessories) for through-wiring or alternatively IN-OUT wiring at one end Reflector made of galvanised sheet steel, painted in white SCUBA is supplied with V2A catches (plastic catches resistant to chemicals are available on request) A function earth has to be provided for protection class II with dimmable electronic ballast Installed on ceiling, wall or trunking using standard V2A spring clips. Trunking installation using ZX2 (see accessories) High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models Dimmable BASIC luminaires are fitted with a DSI-controllable electronic ballast
msc
Cat. no.
L/W/H
Order no. dimmable Basic 42 174 433 42 174 434 42 174 435
Luminaires with PM diffuser with electronic ballast 2/18 W T26 U 684/165/125 2/36 W T26 U 1294/165/125 2/58 W T26 U 1594/165/125
Luminaires with PM diffuser with electr. ballast, protection class II electronic 2/36 W T26 w 1294/165/125 2.6 42 174 436 2/58 W T26 w 1594/165/125 3.2 42 174 437 Luminaires with PM diffuser with low-loss ballast
2/18 W T26 lpf 2/18 W T26 cap. 2/36 W T26 lpf 2/36 W T26 duo 2/58 W T26 lpf 2/58 W T26 duo 684/165/125 684/165/125 1294/165/125 1294/165/125 1594/165/125 1594/165/125 2.4 2.4 3.4 3.4 4.6 4.6 1.6 2.6 3.2 32 161 443 32 161 446 32 161 444 32 161 447 32 161 445 32 161 448 electronic 42 174 422 42 174 423 42 174 424 dimmable Basic 42 174 425 42 174 426 42 174 427
Luminaires with PC diffuser with electronic ballast 2/18 W T26 U 684/165/125 2/36 W T26 U 1294/165/125 2/58 W T26 U 1594/165/125
Luminaires with PC diffuser with electr. ballast, protection class II electronic 2/36 W T26 w 1294/165/125 2.6 42 174 428 2/58 W T26 w 1594/165/125 3.2 42 174 429 Luminaires with PC diffuser with low-loss ballast
2/18 W T26 lpf 2/18 W T26 cap. 2/36 W T26 lpf 2/36 W T26 duo 2/58 W T26 lpf 2/58 W T26 duo 684/165/125 684/165/125 1294/165/125 1294/165/125 1594/165/125 1594/165/125 2.4 2.4 3.4 3.4 4.6 4.6 1.6 2.6 3.2 32 161 433 32 161 436 32 161 434 32 161 437 32 161 435 32 161 438 electronic 42 174 438 42 174 439 42 174 440 dimmable Basic 42 174 441 42 174 442 42 174 443
Luminaires with CH diffuser with electronic ballast 2/18 W T26 U 684/165/125 2/36 W T26 U 1294/165/125 2/58 W T26 U 1594/165/125
Luminaires with CH diffuser with electr. ballast, protection class II electronic 2/36 W T26 w 1294/165/125 2.6 42 174 444 2/58 W T26 w 1594/165/125 3.2 42 174 445 Luminaires with CH diffuser with low-loss ballast
2/18 W T26 lpf 2/18 W T26 cap. 2/36 W T26 lpf 2/36 W T26 duo 2/58 W T26 lpf 2/58 W T26 duo Please note: when using PC diffusers, do not use moderately to strongly alkaline or acidic substances, solvents or cleaning agents which have a corrosive effect on plastics (PC). High and low ambient-temperature versions also available on request as dimmable or emergency-lighting models. 684/165/125 684/165/125 1294/165/125 1294/165/125 1594/165/125 1594/165/125 2.4 2.4 3.4 3.4 4.6 4.6 32 161 453 32 161 456 32 161 454 32 161 457 32 161 455 32 161 458
D1
D2
70 165
125
SCUBA
1
SCUBA T16 cool spot optimizer Aluminium sleeve which is clipped onto the light source (lamp label = CoolSpot) Increases luminous flux output by optimising lamp wall temperature around the cool spot For use in cold ambient temperatures
Cat. no.
SCUBA accessories
s
Cable grip for NYM through-wiring (3 cable grips required for each luminiare) Include an extra grommet per luminaire for wiring in the trunking
Cat. no.
Order no. 22 157 756 20 350 553 22 157 859 22 157 860 22 157 794 22 157 795 20 351 143 20 351 159 20 350 803 22 157 858 22 157 861 22 157 793 20 042 906 22 157 561 22 157 562 20 351 714 22 161 542 22 161 543 22 161 540 22 161 541 22 157 607 22 157 888 22 157 889 22 157 890 22 157 891 22 157 839 22 157 892
End caps
Strain relief
Accessory
Zumtobel is the internationally leading supplier of integral lighting solutions for a wide variety of applications in profes sional interior lighting:
Industry and engineering Offices and education Presentation and retail Hospitality and wellness Art and culture Health and care TRANSIT AREAS A N D C A R PA R K S OFFICES A N D E D U C AT I O N Sport and leisure Transit areas and car parks Orientation and safety
We provide unique customer benefit by integrating technology, design, emotion and energy efficiency. Under the Humanergy Balance concept, we combine the best possible ergonomic lighting quality for peoples wellbeing with the responsible use of energy resources. P R E S E N TAT I O N A N D R E TA I L H O S P I TA L I T Y AND WELLNESS
The companys own sales organisa tions in twenty countries as well as commercial agencies in fifty other countries form an international network of experts and design partners provi ding professional lighting consulting, design assistance and comprehensive services.
ART A N D C U LT U R E
H E A LT H AND CARE
Corporate goal: We want to use light to create worlds of experience, make work easier and improve com munications and safety while remaining fully aware of our responsibility to the environment.
United Kingdom Zumtobel Lighting Ltd. Unit 4 The Argent Centre, Pump Lane Hayes/Middlesex UB3 3BL T +44/(0)20 8589 1800 F +44/(0)20 8756 4800 M enquiries@zumtobel.com www.zumtobel.co.uk USA and Canada Zumtobel Lighting Inc. Location Highland 3300 Route 9W Highland, New York 12582630 T +1/(0)845/691 62 62 F +1/(0)845/691 62 89 www.zumtobel.us www.zumtobel.ca Australia and New Zealand Zumtobel Lighting Pty Ltd 333 Pacific Highway North Sydney, NSW 2060 T +61/(2)8913 5000 F +61/(2)8913 5001 M info@zumtobel.com.au www.zumtobel.com.au China Zumtobel Lighting China Beijing Office T52152 Tayuan Diplomatic Compound, No. 1 Xin Dong Road, Chaoyang District 100600 Beijing T +86/(10) 8532 3886 F +86/(10) 8532 3889 M admin@zumtobel.com.hk Hong Kong Zumtobel Lighting Hong Kong Unit 319, Level 43, Tower 1, Metroplaza, 223 Hing Fong Road, Kwai Chung, N.T. T +852/(0)2503 0466 F +852/(0)2503 0177 M admin@zumtobel.com.hk Singapore Zumtobel Lighting Singapore No. 5 Kaki Bukit Crescent #0403 416238 Singapore T +65/(0)6848 2560 F +65/(0)6234 4972 M info@zumtobel.com.sg
Norway Zumtobel Belysning Pilestredet 75C 0308 Oslo T +47/81 53 20 23 F +47/81 53 20 24 M firmapost@zumtobel.no Sweden Zumtobel Belysning Birger Jarlsgatan 57 113 56 Stockholm T +46/(0)8/26 26 50 F +46/(0)8/26 56 05 M info@zumtobel.se www.zumtobel.se Poland Zumtobel Lighting GmbH Przedstawicielstwo w Polsce ul. Zuga 14/2 01806 Warsawa T +48/22 635 6499 F +48/22 865 1530 www.zumtobel.pl Russia Zumtobel Staff Official Representative office Office 2111/Skakovaya17 125040 Moscow T +7/095 945 3633 F +7/095 945 1694 www.zumtobel.ru Head offices Zumtobel Lighting GmbH Schweizer Strasse 30 Postfach 72 6851 Dornbirn, AUSTRIA T +43/(0)5572/3900 F +43/(0)5572/22 826 Zumtobel Licht GmbH Grevenmarschstrasse 7478 32657 Lemgo, GERMANY T +49/(0)5261/2 120 F +49/(0)5261/2 127777 www.zumtobel.de www.zumtobel.com
Down/uplights
Recessed luminaires
Highbay luminaires
Lighting management
Emergency lighting
Art.No. 04 797 794UK 02/07 Zumtobel Lighting GmbH Technical data was correct at time of going to press. We reserve the right to make technical changes without notice. Please contact your local sales office for further information. Printed on environmentallyfriendly chlorinefree paper. Printed on Consort Royal.
SCUBA
In environments where dust, dirt and moisture abound, SCUBA provides highly functional lighting.
www.zumtobel.com/scuba