ANCHOR BOLT DESIGN FOR SHEAR AND TENSION Anchor bolt specs ASTM 307 Yield stress, Fy ASTM

325 Yield stress, Fy Number of thread per inch, n m (min of 10mm, max of 50mm) Allowable stresses Fb 136.52 Mpa Ft 136.52 Mpa Fv 68.26 Mpa Shear: V fc' D ls Tension T u lt l Check for bolt stresses Ag At Allowable tension stress, Ft fv ft Bending moment due to shear M fb Distance, s from rebar Length of bend

33 ksi 7 10 mm

227.527 Mpa

5.00 20.68 12.70 152.35 5.00 3.58 35.00 187.35

kN MPa mm mm kN Mpa mm mm

126.60 mm2 94.95 mm2 39.50 Mpa 52.66 Mpa ok ok

50.00 kN-mm 248.851 Mpa 62.45 mm 100.00 mm

reduce grout thickness

NOMENCLATURE Fy Yield stress of anchor bolt, Mpa Fv Allowable shear stress, Mpa Ft Allowable tensile stress, Mpa Fb Allowable bending stress, Mpa Ac Area of concrete in compression, mm2 D Diameter of anchor bolt, mm V Shear force per anchor bolt, kN T Tensile force per bolt, kN Ag Gross section area of anchor bolt, mm2 At Tensile stress area of anchor bolt, mm2 Fp Allowable bearing stress on concrete, Mpa fc' Compressive strength of concrete at 28 days, Mpa ls Length of anchor bolt required to resist shear force, mm lt Length of anchor bolt required to resist tension force, mm l Total length of embedment required, mm u Allowable bond stress of concrete, Mpa fv Actual shear stress in anchor bolt, Mpa ft Actual tensile stress in anchor bolt, Mpa n Number of threads per inch for anchor bolt m thickness of grout, mm M Shear moment, kN-mm