Humidity Sensor

Type HCZ-D5
Description This product specification is applied to the Humidity Sensor Type HCZ-D5. The terminal electrode material uses lead free solder (Sn / Ag / Cu). This product is conformity with RoHS directive which means that lead, cadmium, mercury, hexavelent chromium and specific bromine-based flame retardants have not been used. Applications The applications of the component are used in relative humidity measurement, control and display. There are many end products can be used. Fox example air conditioner, humidifier, dehumidifier, hygrometer, recorder, transmitter etc.

Model Number HCZ D5 A

Product Type

Dip Type Humidity Sensor, D : 5% RH

With (A) / Without (B) Housing Package Each Pieces

Configuration and Main Parts


Configuration (Units : mm) Symbol A B C D E F G H I J Dimensions (mm) 8.3 0.2 13.5 0.2 4 0.5 15 2 2.54 0.2 0.5 0.1 0.2 0.1 2 0.5 5.08 0.3 10 0.3

www.element14.com www.farnell.com www.newark.com

Page <1>

04/06/11 V1.1

Humidity Sensor
Type HCZ-D5
Main Parts
No. 1 2 3 4 5 Parts Sensor case Substrate Sensing material Electrode Lead frame Reference PBT Alumina Polymer Ag / Carbon Phosphor bronze

Electrical Characteristics
General Characteristics Units Rated voltage Rated power Operating frequency range Operating temperature range Operating humidity range Impedance range at 60% RH and 25C** Humidity accuracy Hysteresis (40% RH to 80% RH) Temperature dependence (Reference) Vrms mW KHz C % RH K % RH % RH / C Min. 0.5 0 19.8 -5 Typ. 1 0.3 Max. 1 0.2 2 60 90 50.2 +5 2 -

**Measurement by LCR meter at 1 KHz, 1 Vrms (sine wave)


Relative Humidity - Impedance - 25C, 1 KHz, 1 Vrms (Sine wave) % RH Normal Value (K) 20 6,300 30 1,400 40 310 50 87 60 31 70 11.8 80 4.8 90 2

Relative humidity - Impedance curve is shown in page 3

Mechanical Characteristics
No. 6.1 6.2 6.3 6.4 Item Shock resistance Vibration resistance Resistance to soldering heat Strength of terminations Description Drop down 3 times at 80 cm. 2 hours each in the directions of X-Y-Z at the frequency of No abnormal appearance and 10-55 Hz and amplitude of 1.5 mm. electrical properties. The lead terminal shall be immersed by 3 mm from the substrate for 3 seconds in solder bath of 330 5C. 500 g at 10 s in the axial direction of lead terminal. Secured Criteria*

www.element14.com www.farnell.com www.newark.com

Page <2>

04/06/11 V1.1

Humidity Sensor
Type HCZ-D5
Reliability
No. 7.1 7.2 7.3 Item Heat resistance Cool resistance Humidity resistance Description 1,000 hrs at 70C 1,000 hrs at -30C 1,000 hrs at 60C, 90% RH Repeat 1,000 cycles One cycle: 30 mins at 25C, < 20% RH 30 mins at 25C, > 90% RH Repeat 100 cycles Each cycle: 30 mins at -30C 30 mins at 85C 3,000 hrs at 1 KHz, 1 Vrms Criteria*

7.4

Humidity cycle

< 5% RH

7.5

Temperature cycle

7.6

Voltage resistance

* The criteria test that the sensors finish the description process after 2 hours under normal temperature and humidity, The test condition is fixed at 25C, 60% RH by LCR meter at 1 KHz, 1 Vrms (sine wave).

References Relative Humidity - Impedance Curve - Measured at 1 KHz, 1 Vrms (sine wave)

www.element14.com www.farnell.com www.newark.com

Page <3>

04/06/11 V1.1

Humidity Sensor
Type HCZ-D5
Impedance - % RH vs. Temperature
RH% 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 5C 10,000 4,800 2,100 980 480 250 130 73 41 23 13 7.2 4 2.2 10C 15,000 7,400 3,400 1,500 700 350 190 100 57 32 19 11 6.4 3.7 2.2 15C 11,000 5,300 2,400 1,100 520 260 140 80 46 27 16 9.5 5.8 3.5 2.1 20C 8,200 3,900 1,800 820 400 200 110 64 37 22 14 8.4 5.2 3.3 2 25C 6,300 3,000 1,400 630 310 160 87 49 31 19 11.8 7.5 4.8 3 2 30C 4,900 2,300 1,100 490 240 120 74 43 26 16 10.2 6.7 4.4 2.9 1.9 35C 4,000 1,800 870 390 190 100 61 36 22 14 9.1 6.1 4.1 2.8 1.8 40C 3,300 1,500 710 320 160 86 51 30 19 12 8.2 5.6 3.8 2.6 1.8 45C 2,800 1,300 600 270 130 73 44 26 17 11 7.5 5.2 3.6 2.5 1.7 50C 2,500 1,100 510 230 110 63 38 23 15 10 6.9 4.9 3.4 2.4 1.7 55C 2,200 1,000 450 200 100 55 34 21 14 9.2 6.5 4.6 3.3 2.4 1.7
Unit: K

60C 2,100 920 410 180 91 50 30 19 13 8.6 6.1 4.4 3.2 2.3 1.6

Part Number Table


Description Humidity Sensor Part Number HCZ-D5-B HCZ-D5-A

Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. Premier Farnell plc 2011.

www.element14.com www.farnell.com www.newark.com

Page <4>

04/06/11 V1.1