Mounting Details For Aircraft Cable Interface Edge EX

Aircraft Cable to Grid Ceiling (AC_G_)


Utilize with on-grid mounting with acoustical grid ceiling
Tie off to structure Conduit and fittings (by others) 4-Octagonal Junction box IDS clip

5 Power canopy Coupler Aircraft cable Strain relief

2 Non-power canopy

Coupler Aircraft cable

Power side Aircraft Cable to Junction Box (AC_JB)

SJT cord

Non-power side
1/4-20 stud screw (by others)

Utilize with sheet rock and off grid acoustical grid ceiling

Conduit and fittings (by others)

4-Octagonal Junction box

5 Power canopy Coupler Aircraft cable Strain relief SJT cord

2 Non-power canopy

Coupler Aircraft cable

Power side Aircraft Cable to Structure (AC_ST)


Utilize for inaccessible hard ceiling
Conduit and fittings (by others)

Non-power side
1/4-20 stud screw (by others)

4 -Octagonal junction box (by others) 5 Power canopy Coupler Aircraft cable Strain relief Coupler Aircraft cable

Power side

SJT cord

Non-power side

Warnings: 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product and the hazards involved. 2. Minimum 90C supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixture alterations. 6. Contact Pinnacle with any installation questions or field issues.

PINNACLE ARCHITECTURAL LIGHTING 12655 E. 42nd Ave. Suite 50 Denver CO 80239 Phone: 303.322.5570 Fax: 303.322.5568 July 2009

Mounting Details For Pendant Pipe Interface Edge EX


Pendant Pipe to Junction Box (PP_JB)
Conduit and fittings (by others)

Utilize with sheet rock and off grid acoustical grid ceiling
4-Octagonal junction box (by others) 5 Power canopy 5 J-box canopy

Set screw Pendant pipe

Set screw Pendant pipe

Power side Pendant Pipe to Structure (PP_ST)


Utilize for inaccessible hard ceiling
Conduit and fittings (by others) 4-Octagonal junction box (by others) 5 Power canopy Set screw Pendant pipe

Non-power side

Set screw 5 J-box canopy Pendant pipe

Power side

Non-power side

Warnings: 1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product and the hazards involved. 2. Minimum 90C supply conductors. 3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes. 4. Contact Pinnacle prior to making any fixture alterations. 6. Contact Pinnacle with any installation questions or field issues.