Home | More Coal Industry News | The Evolution of Power Plant Water/Steam Chemistry
Power Engineering
Share
Condensate/Feedwater Treatment
When I began my utility career in 1981, widely-accepted condensate/feedwater chemical treatment consisted of ammonia or amine feed to establish an alkaline environment. This treatment was combined with feed of an oxygen scavenger/metal passivator to eliminate any oxygen not removed by a deaerator and/or a deaerating condenser. The combination of ammonia and oxygen scavenger feed came to be called all-volatile treatment reducing, [AVT(R)]. The thinking was that all oxygen must be eliminated from the feedwater system. "This changed in 1986. On December 9 of that year, and elbow in the condensate system ruptured at the Surry Nuclear Power Station [near Rushmere, Virginia, USA]. The failure caused four fatalities and tens of millions of dollars in repair costs and lost revenues." [1]. Researchers learned from this accident and others that the reducing environment produced by oxygen scavenger feed results in single-phase flow-accelerated corrosion (FAC). The corrosion is most prevalent at directional changes and flow disturbances, e.g., feedwater and economizer elbows, valve perturbations, feedwater heater drains, and other locations. The pipe wall gradually thins, and catastrophic failures occur when the corroded area can no longer withstand the internal pressure. The chart in Figure 1 shows that the phenomenon is primarily influenced by pH and temperature. The corrosion mechanism typically reaches a maximum at a temperature of 300o F, which in the case of HRSGs can initiate severe FAC in the LP evaporator circuit with its many short-radius elbows. IP and HP evaporator elbows can also suffer from FAC at times even though the temperature is greater than in the LP. In addition to the accident noted above at the Surry Nuclear Plant, during the last decade a FAC-induced attemperator line failure occurred at a sister plant to one at which I worked, in which the failure killed two plant personnel. I cannot overemphasize the importance of this issue. CMI Energy HRSG Data CMI Energy Aftermarket Data CMI Energy HRSG Brochure
Featured Whitepaper
1 of 6
2/16/2013 7:42 PM
http://www.power-eng.com/articles/print/volume-116/issue-10/features/t...
The feedwater treatment program now employed for most drum units is all-volatile treatment oxidizing [AVT(O)]. In this program, the (typically) small amount of air that leaks in through the condenser is allowed to remain, with ammonia injection to raise the pH to a range of 9.2 to 9.6. If the cation conductivity of the feedwater is maintained below 0.2 S/cm, the magnetite (Fe3O4) layer that naturally develops on carbon steel becomes interspersed and covered with a coating of ferric oxide hydrate (FeOOH), which is not susceptible to FAC. AVT(O) is an offshoot of oxygenated treatment (OT), which was developed in Europe almost 40 years ago as a condensate/treatment method for once-through steam generators. With OT, pure oxygen is deliberately injected into the condensate and feedwater to induce formation of the FeOOH protective coating. The condensate must be very pure (cation conductivity 0.15 S/cm) for this treatment to work properly. An important point to note is that if the feedwater system contains any pre-heaters with copper-alloy tubes, AVT(O) or OT cannot be employed, as the oxygen would quickly corrode the copper. AVT(R) is the only choice when copper alloys are present, but chemistry must be carefully monitored and controlled to achieve a balance between minimized copper corrosion and FAC. [2]
Forced Circulation Steam Generators for SAGD Applications 3 Case Studies: How to Build a Corporate Crane & Rigging Training Strategy New Long Life Lubricant for Engines Burning Sour
0 With regard to HRSGs, single-phase FAC can be addressed in the design phase by fabricating evaporator elbows from 2.5 percent chromium steel as opposed to straight carbon steel. Even a small amount of chromium imparts great Twitter resistance to FAC. Admittedly, however, this method will increase material costs for the LP steam generator. 0 Another phenomenon that may affect high-pressure steam generators is two-phase FAC. This corrosion occurs in locations where water and steam exist simultaneously, such that any protection offered by AVT(O) or OT is lost when the oxygen flashes LinkedIn the steam. A primary location is the deaerator in both conventional units and HRSGs. away with Two-phase FAC is not easy to control, so regular inspections of locations susceptible to the corrosion are important. I have personally inspected or observed situations of two-phase FAC corrosion of deaerators and feedwater heater drains in coal-fired units. The latter actually caused a failure, fortunately when no personnel were in the area at the time of the occurrence.
Other location(s) 1 two-phase FAC are the distribution headers and cooling circuits of air-cooled condensers. for Two-phase condensate from the LP turbine exhaust can be quite damaging in these locations.
Share
A different issue regarding oxygen corrosion must be noted. For low-pressure boilers such as industrial units or power plant auxiliary boilers, an oxygen scavenger/metal passivator is often quite beneficial, as the makeup may contain high levels of dissolved oxygen. For units at pressures below 600 psig, sodium sulfite (Na2SO ) is a practical choice. The 3 compound removes oxygen thusly, 2Na2SO + O2 2Na2SO4 3 For higher pressures, one of the substitutes for hydrazine (N2H4) is a better choice, as sodium sulfite will break down to produce sulfur dioxide (SO ) and perhaps some hydrogen sulfide (H2S). Both of these decomposition products can 2 cause considerable damage in boilers.
Power Engineering
Topic Index
View Power Engineering articles by topic, A-Z
BUYERS GUIDE
Categories Companies Products Applications Complete plant supply Boilers Valves Finance and investment Instruments, measuring Component supply and manufacture Air pollution control services Monitoring equipment MORE BUYERS GUIDE LISTINGS >>
Steam Purity
The steam turbine is, of course, a highly-tuned piece of equipment that has to operate under high stress conditions. Even in the absence of ingress of catastrophic impurities, or concentrations thereof, the recirculating nature of drum boilers will cause an increase in dissolved solids within the boiler water. If these are not controlled properly, the solids will carry over with steam to foul downstream components. Carryover occurs by two mechanisms, either mechanical, where impurities enter the steam path via water droplets entrained in steam, or vaporous, where contaminants volatilize. Mechanical carryover typically results from poor boiler operation, improper chemistry control, or poor design/maintenance of the drum and its water/steam separating devices. Even in the best systems, a minor fraction of water will carry over with steam. Boiler pressure plays an important part in mechanical carryover, as the density of water and steam approach unity as the pressure approaches the critical point of 3208 psia. With vaporous carryover, the impurities volatilize, and are not
2 of 6
2/16/2013 7:42 PM
http://www.power-eng.com/articles/print/volume-116/issue-10/features/t...
entrained in moisture droplets as they enter the steam. Boiler pressure also is very important with regard to vaporous carryover issues, as higher pressure typically equates to greater carryover of these products.
0
Twitter
0
LinkedIn
The list below outlines many of the major carryover products, and the difficulties they cause in the steam system. The list also includes common limits for reheat steam purity. These limits have been lowered over the decades, and may be lowered even more, as knowledge improves regarding the influence of impurities on turbine components.
1
Sodium phosphates. Phosphates carry over mechanically and settle out in the superheater and reheater, Share particularly the latter. Many plants have had to deal with overheating in reheater U-bends due to sodium phosphate deposition. Sodium limit, 2 parts-per-billion (ppb). Chlorides. The majority of chlorides will carry over mechanically although some vaporous carryover may occur as ammonium chloride (NH4Cl) or even some hydrogen chloride (HCl). Chloride's most notorious reputation in steam circuits is as a pitting and stress corrosion cracking agent in low-pressure turbines. Limit, 2 ppb. Sulfates. Sulfate is another anion that will carry over as sodium sulfate or in AVT units as ammonium sulfate [(NH4)2SO4]. Volatile carryover is lower than from chlorides. Sulfate causes similar problems as chloride, but is not quite as nasty. Limit, 2 ppb. Silica. Vaporous carryover is silica's primary transport mechanism. Silica will precipitate in the high-pressure end of the turbine as steam pressure decreases during its path through the turbine blades. Silica forms a tenacious and hard deposit that is difficult to remove. Limit, 10 ppb. Copper. Copper carries over vaporously, particularly in steam generators operating at 2400 psi and above. Like silica, copper precipitates on high-pressure turbine blades, where only a few pounds of deposition will alter the aerodynamics to the point that megawatts will be lost. Steam purity limits for copper are not standard, but a common limit for feedwater is 2 ppb. The allowable concentration of impurities varies from unit to unit and is dependent upon operating pressure, system configuration, and other factors. While general charts and graphs are available to calculate maximum impurity control limits, proper monitoring of each unit is necessary to determine the limits for that particular steam generator. This article only briefly touched upon many important issues related to high-pressure water steam chemistry. The reader should refer to the literature and consider attending events such as the Electric Utility Chemistry Workshop for additional information.
References
1. Guidelines for Controlling Flow-Accelerated Corrosion in Fossil and Combined-Cycle Plants, EPRI Report 1008082, Final Report, March 2005, the Electric Power Research Institute, Palo Alto, California. 2. Buecker, B., and S. Shulder, "The Basics of Power Plant Cycle Chemistry"; pre-conference seminar for the 27th Annual Electric Utility Chemistry Workshop, May 15-17, 2007, Champaign, Illinois, USA. Many of the lessons learned from the coal-fired power industry are directly applicable to high-pressure heat recovery steam generators.
Author
Brad Buecker is a contributing editor for Power Engineering and also serves as a process specialist with Kiewit Power Engineers, in Lenexa, Kan.
1
Like
0
Twitter
0
LinkedIn
1
Share
Sponsored by FLSmidth
Save
Font Sizes:
3 of 6
2/16/2013 7:42 PM
http://www.power-eng.com/articles/print/volume-116/issue-10/features/t...
0 Comments
0
Recommend this article
RSS | Subscribe
0
LinkedIn Headline News
Renewable Energy REITs or MLPs Would Unlock Billions for Project 1 Development
Share
Live webcast: Power generators are able to comply with emissions rules now UPDATE: Mitsubishi Heavy Industries purchases Pratt & Whitney Power Systems Live video webcast to be filmed from POWER-GEN exhibit floor And The Winners Are... Download Power Engineering to your iPhone or Android!
View This Issue View Archives
Webcasts
Emissions Control: Understanding Your Options Lubrication Challenges for Gas Engines in Sour Gas Application
More Webcasts >>
Latest News
Control Solutions CNG is key for Oklahoma's Energy Future Seizing the Opportunity EPRI discusses implications of 316(b) Obama pushes for Smart Grid
We Recommend
4 of 6
2/16/2013 7:42 PM
http://www.power-eng.com/articles/print/volume-116/issue-10/features/t...
Live webcast: Power generators are able to comply with emissions rules now News in Briefs POWER-GEN International Tech Tours Live video webcast to be filmed from POWER-GEN exhibit floor
The Challenge Ahead: POWER-GEN Twitter International kicks off with explosive 0 keynote session
During the Tuesday morning keynote session of LinkedIn POWER-GEN International 2012, four executives e... More Power Generation News >>
1
Share
Weekly Newscast Suppliers Showcase Classifieds Cogeneration & On-Site Power Production
TOPICS
Latin America Coal Copyright 2011 Privacy Policy | Terms & Conditions Gas Renewables Nuclear Distributed Generation O&M Emissions Business Environmental Services
ABOUT US
Contact Us Advertising Subscribe About Us PennWell Events PennWell Websites
RESOURCES
Current Issue Online Archives RSS Feeds Buyer's Guide
SUPPORT
Register Login Forgot Password Site Map
5 of 6
2/16/2013 7:42 PM
http://www.power-eng.com/articles/print/volume-116/issue-10/features/t...
0
Twitter
0
LinkedIn
1
Share
6 of 6
2/16/2013 7:42 PM