Anda di halaman 1dari 2

POWER CAPACITOR

Maximum voltage 20.70kV. Maximum output 750kVAr (Single Phase) All Polypropylene (APP) film dielectric. Ultra low losses. Indoor or Outdoor application up to 95kV BIL. Superior electrical performance. Improved tank rupture characteristics. POLE MOUNTED CAPACITOR BANK
It consists of Procap make Controller solid Dielectric Vacuum Switch, Current Sensor having high Dielectric Strength, Potential Transformer & Power Capacitor Units. Available at 15kV, 25kV & 35kV application Suitable for outdoor application Less space required Auto or Manual operated Power Factor Correction System. Application: Agriculture Load, Induction Furnance, Distribution Transformer and Heavy Industrial Load

OPEN RACK SUBSTATION BANK


Shunt Compensation Capacitors available in internal and external fuse protection Range: Maximum Power : 60MVAR or more System Voltage : 11kV-230kV Capacitor : APP Film Type

M.V. PAD MOUNTED CAPACITOR BANK


Shunt Compensation (Fixed and Automatic) Capacitors available in external fuse protection Range: Maximum Power : 9MVAR System Voltage : 6kV-11kV Capacitor : APP Film Type

Cast Resin Material ISO 9001:2008

Outdoor PT up to 72 KV Outdoor CT up to 72 KV

Indoor PT up to 36 KV Indoor CT up 36 kV

Type Test Report for Oil Type Transformer Type Test Report for Cast Resin Transformer Also manufactured Amorphous Type Transformer

ISO 9001 - 2008 ISO 14001

Vacuum Circuit Breakers


Rated breaking time of all types - 3 cycle Nuclear power certification ANSI C37.06 / EED1100 Developed the first domestic Embedded VCB Passed KERI, KEMA, CESI development test Standard Specification: IEC 62271-100 [M2, E2, C2 Class]

POLE MOUNTED CAPACITY : 10-333kVA VOLTAGE : up to 36kV PAD MOUNTED CAPACITY : 100-5,000kVA VOLTAGE : up to 36kV OIL IMMERSED CAPACITY : 25-1,000kVA VOLTAGE : up to 36kV POWER TRANSFORMER CAPACITY : 1MVA-30MVA VOLTAGE : up to 72kV CAST RESIN CAPACITY : 100-15,000kVA VOLTAGE : up to 36kV

Vacuum Transfer Switch


Medium Voltage load transfer with Vacuum Interrupter Easy maintenance with drawable structure Small and light weight for 2 stage installation Rating: 7.2kV 400/600A 12.5kA/sec Transfer Sequence: A off B

Vacuum Contact Switches


Rated breaking time 6.3kA(16.4kA peak) Minimize switch surge through optimal VI design Standard Specification: IEC 60470, IEC 60282-1 Realization of mechanical interlock between VCSs or with other devices

Current Limit Power Fuse


Standardized external size with IEC & DIN Std Excellent current limiting & cut off characteristics. Optimal strikers (ensure tripping performance with LBSI Rating: 7.2kV 50kA 24/25.8kV 40kA

Load Break Switch/Auto Section Switch


Maximum fuse combined capacity in the country-Max. 100A LA & PF external combination structure Easy to design single-body panel through optimal form design Standard Specification: IEC 62271-105, IEC 60265-1, KEMC1126 Compatible structure for LBS and ASS

Minimized installation space (63% compared with MCSGI) SF gas free, environment friendly