APPENDIX 2D
APPENDIX 2D
Capacity
100%
Description
Advanced technology combustion (gas) turbine generator, suitable for firing natural gas, nominally rated at 170 MW at 62 F and 84 percent relative humidity (RH) ambient conditions. Dry-low NOx combustion control. Inlet air filter houses. TEWAC or hydrogen cooled generator. Compressor water wash system (on/off-line). Acoustical enclosure. CO2 or FM-200 fire protection system.
2 2 2 2 2
Capacity
100%
Description
HRSG, three-pressure, fired, reheated with horizontal gas flow and vertical fin tubes. Selective catalytic reduction (SCR) system,. 12,000 gallon aqueous ammonia storage tanks. Aqueous ammonia truck unloading skid. Aqueous ammonia forwarding skid. Aqueous ammonia vaporizer and injection skid.
2 2 1 1 2
2D-1
Quantity
2 2
Capacity
100% 100%
Description
CO catalyst system. HRSG inlet/outlet ducts and exhaust stack.
Capacity
100%
Description
Condensing type reheat steam turbine generator nominally rated at 310 MW. The STG has the following accessories: Lube oil system. Hydraulic oil system. Steam seal and exhauster system. Turbine control system. Turning gear. TEWAC or hydrogen cooling system. Seal oil system. Steam stop/control valves.
Capacity
50% 100% 100%
Description
Condensate pump. Condensate storage tank - 100,000 gallons. High pressure boiler (HRSG) feed pumps with interstage bleed.
Capacity
100% 100% 100%
Description
Air-cooled steam condenser with vacuum deaeration. Condenser mechanical vacuum pumps. Steam jet air ejectors.
2D-2
Capacity
100% 100% 100%
Description
Air compressors, air-cooled. Air receiver tank. Air dryer skids, each with two desiccant dryer towers.
Capacity
100% 100%
Description
Demineralized water tank - 150,000 gallons. Demineralization/water treatment plant including chemical storage vessels and chemical injection packages. Demineralized water pumps. Oil/water separator. Waste water storage tank -300,000 gallons.
2 1 1
Capacity
100% 50%
Description
Metering station. Fuel gas compressor.
Capacity
100%
Description
Natural Gas Fired.
2D-3
Capacity
Lot 100% 100%
Description
High voltage switchyard breakers. CT Generator 101 step-up (GSU) transformers. OA/FA/FA, 138 kV - 18 kV. CT Generator 201 step-up (GSU) transformers. OA/FA/FA, 69 kV - 18 kV.
100%
Quantity
1
Capacity
100%
Description
ST Generator step-up (GSU) transformers. OA/FA/FA, 230 kV - 18 kV. CT GSU transformer circuit breakers, 18 kV. ST GSU transformer circuit breaker, 230 kV. Unit auxiliary transformers (UAT). OA/FA/FA, 18 kV 4.16 kV. Electrical equipment including 4.16 kV switchgear, 480 V load centers and MCCs.
2 1 2.
Lot 100%
Description
Combustion turbine generator with starter package (CT) CT inlet air filter house Steam turbine generator Air-cooled condenser Heat recovery steam generator (HRSG) HRSG stack SCR system
Length
100
Width
45
Height
20
2 1 1 2 2 2
70 19 94 94 145 83
2D-4
1 1 1 2 1
Cooling water heat exchanger Demineralized water storage tank Condensate storage tank Raw water/fire water storage tank Waste water storage tank
125 -----
20 30 21 28 28
2D.13 Buildings
Dimension (ft) Quantity
1 1 1 1 1 1 1
Description
Administration/control room building Steam turbine generation building CT generation building Fuel gas compressor building Maintenance/warehouse building Electrical Equipment Building
Length
75 155 285 95 130 60
Width
65 95 114 60 75 15 15
Height
20 82 40 32 32 14 14